Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “control room”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Modularized instrument system for turbojet engine test facilities

A modular instrument system is being developed to handle the many data channels encountered in turbojet engine testing. Each module contains a group of transducers and all the signal conditioning multiplexing, and digitizing electronics necessary for direct interface with a digital computer. The digital interface within each module is the same for all modules; in addition, each module provides a controlled environment for its contents. A minicomputer in the control room gathers the data, performs on-line calculation and display, and interfaces with a shared recording and computing system. The advantages of this system are: (1) reduced manpower for system installation, setup, and checkout; (2) standardized equipment interfaces; (3) increased reliability through automatic system testing and minimization of manual adjustments; and (4) reduced cost through minimization of wiring and simplification of control room display.

Nieberding, W. C.↗

Modularized instrument system for turbojet engine test facilities

A new modular instrument system is being developed to handle the many channels of data commonly encountered in turbojet engine testing. Each module contains a group of transducers and all the signal conditioning, multiplexing, and digitizing electronics necessary for direct interface with a digital computer. The digital interface within each module is the same for all modules. Each module provides a controlled environment for its contents. A minicomputer in the control room gathers the data, performs some on-line calculation and display, and interfaces with a shared recording and computing system. The advantages of this system are (1) reduced manpower for system installation, setup, and checkout; (2) standardized equipment interfaces; (3) increased reliability through automatic system testing and through minimization of manual adjustments; and (4) reduced cost through minimization of wiring and simplification of control room display.

Nieberding, W. C.↗

INITIATORS AND TRIGGERING CONDITIONS FOR ADAPTIVE AUTOMATION IN ADVANCED SMALL MODULAR REACTORS

It is anticipated that Advanced Small Modular Reactors (AdvSMRs) will employ high degrees of automation. High levels of automation can enhance system performance, but often at the cost of reduced human performance. Automation can lead to human out-of the loop issues, unbalanced workload, complacency, and other problems if it is not designed properly. Researchers have proposed adaptive automation (defined as dynamic or flexible allocation of functions) as a way to get the benefits of higher levels of automation without the human performance costs. Adaptive automation has the potential to balance operator workload and enhance operator situation awareness by allocating functions to the operators in a way that is sensitive to overall workload and capabilities at the time of operation. However, there still a number of questions regarding how to effectively design adaptive automation to achieve that potential. One of those questions is related to how to initiate (or trigger) a shift in automation in order to provide maximal sensitivity to operator needs without introducing undesirable consequences (such as unpredictable mode changes). Several triggering mechanisms for shifts in adaptive automation have been proposed including: operator initiated, critical events, performance-based, physiological measurement, model-based, and hybrid methods. As part of a larger project to develop design guidance for human-automation collaboration in AdvSMRs, researchers at Idaho National Laboratory have investigated the effectiveness and applicability of each of these triggering mechanisms in the context of AdvSMR. Researchers reviewed the empirical literature on adaptive automation and assessed each triggering mechanism based on the human-system performance consequences of employing that mechanism. Researchers also assessed the practicality and feasibility of using the mechanism in the context of an AdvSMR control room. Results indicate that there are tradeoffs associated with each mechanism, but that some are more applicable to the AdvSMR domain. The two mechanisms that consistently improve performance in laboratory studies are operator initiated adaptive automation based on hierarchical task delegation and the Electroencephalogram(EEG) –based measure of engagement. Current EEG methods are intrusive and require intensive analysis; therefore it is not recommended for an AdvSMR control rooms at this time. Researchers also discuss limitations in the existing empirical literature and make recommendations for further research.

99 GENERAL AND MISCELLANEOUS↗

Multi-Device Knob Utility for LCLS

At the SLAC National Accelerator Laboratory (SLAC) the Controls Department (CD) has developed a new Multi-Device Knob Utility (MKB) based on the Experimental Physics and Industrial Control System (EPICS) toolkit for controlling one or more Process Variables (PVs) in unison, or simultaneously, from a physical knob located in the control room, or from various software tools such as the EPICS Extensible Display Manager (EDM) or a Swing slider in Java. A group of devices are hooked up to a knob, and then the value written to the devices is a simple function of the value of the knob. This is used, most commonly, to create a bump in the electron beam for the Linac Coherent Light Source (LCLS). Control system variables typically controlled are magnetic fields, phases, and timing offsets. This paper describes the technologies used to implement this utility.

43 PARTICLE ACCELERATORS↗

Orbit Display's Use of the Physics Application Framework

At the SLAC National Accelerator Laboratory (SLAC) the Controls Department (CD) is developing a physics application framework based on the Java(tm) programming language developed by Sun Microsystems. This paper will discuss the first application developed using this approach: a new Orbit Display. The software is being developed by several individuals in reusable Java packages. It relies on the Experimental Physics and Industrial Control System (EPICS) toolkit for data collection and XAL - A Java based Hierarchy for Application Programming for model parameters. The Orbit Display tracks and displays electron paths through the Linac Coherent Light Source (LCLS) in both a graphical, beam line plot, and tabular format. It contains many features that may be unique to SLAC and is meant to be used both in the control room and by individuals in their offices or at home. Unique features include BSA Beam Synchronous Acquisition (BSA), Orbit Fitting, and Buffered Acquisition.

43 PARTICLE ACCELERATORS↗

Development of a diversity and defense-in-depth strategy for the CNNC Fuqing, Fangjiashan and Hainan nuclear plants - 379

The purpose of this paper is to provide an overview of the development of the Diversity and Defense-in- Depth (D3) strategy for the China National Nuclear Corporation Fuqing, Fangjiashan, and Hainan Nuclear Plants. The Nuclear Power Plant (NPP) Digital Control System (DCS) and advanced control room was completed by Invensys and China Nuclear Power Engineering (CNPE)/Nuclear Power Institute of China (NPIC) for these eight new Chinese built Pressurized Water Reactor plants. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

HIGH-LEVEL CONTROL SYSTEM IN C#

We have started upgrading the control room programs for the injector at the Advanced Light Source (ALS). We chose to program in C* exclusively on the .NET Framework to create EPICS client programs on Windows Vista PCs. This paper reports the status of this upgrade project.

43 PARTICLE ACCELERATORS↗

Automated System-wide Event Detection and Classification Using Machine Learning on Synchrophasor Data

As the number of phasor measurement units (PMUs) deployed in a power system increases, and their data volume streamed to the control canter intensifies, operators are facing challenges related to the analysis of such data, which need to be observed and responded to as the measurements are displayed in the Control Room. Humans are generally unable to process such large amount of data efficiently and rapidly. There is an apparent need for automated ways to analyze the data, extract actionable information about occurrence of specific events, and characterize the events quickly and cost effectively. This paper discusses the use of machine learning (ML) to facilitate such tasks by providing automated, highly computationally efficient, and cost-effective ways of extracting actionable information from synchrophasor big data in real-time. We developed Big Data Smart (BDSmart) ML-based prototype tool for the Control Room use that automatically analyses data properties from synchrophasor system measurements taken across the three grid Interconnections in the USA (Western, Eastern and ERCOT). The data collected from several hundreds of PMUs located across the Interconnections over a period of two years have been made available for our extensive study. As a result, we were able to identify a number of big data properties that influence how ML methodology is applied to select, develop, train and test the data models that can eventually be used for the tool implementation. The resulting set of candidate algorithms spans unsupervised, supervised, semi-supervised and transfer-learning approaches. Many ML techniques, such as decision trees, multinomial logistic regression, feed-forward neural networks, K-nearest neighbor, multiclass support vector machine, and single and multi-channel convolutional neural networks, are implemented, and their performance is examined. We offer the results from testing the data models. The novelty of our study is in the approaches for bad data detection and mitigation, selection of a simplified feature for event detection, and data label improvements. As a result, we came up with a list of recommendations for the utilities on how to improve the PMU recording practices to cater to the future ML applications aimed at automating the analysis of synchrophasor data.

Synchrophasors, Machine Learning, System-wide Even↗

Light Water Reactor Sustainability Program: Digital Architecture Requirements

The Digital Architecture effort is a part of the Department of Energy (DOE) sponsored Light-Water Reactor Sustainability (LWRS) Program conducted at Idaho National Laboratory (INL). The LWRS program is performed in close collaboration with industry research and development (R&D) programs that provides the technical foundations for licensing and managing the long-term, safe, and economical operation of current nuclear power plants (NPPs). One of the primary missions of the LWRS program is to help the U.S. nuclear industry adopt new technologies and engineering solutions that facilitate the continued safe operation of the plants and extension of the current operating licenses. Therefore, a major objective of the LWRS program is the development of a seamless digital environment for plant operations and support by integrating information from plant systems with plant processes for nuclear workers through an array of interconnected technologies. In order to get the most benefits of the advanced technology suggested by the different research activities in the LWRS program, the nuclear utilities need a digital architecture in place to support the technology. A digital architecture can be defined as a collection of information technology (IT) capabilities needed to support and integrate a wide-spectrum of real-time digital capabilities for nuclear power plant performance improvements. It is not hard to imagine that many processes within the plant can be largely improved from both a system and human performance perspective by utilizing a plant wide (or near plant wide) wireless network. For example, a plant wide wireless network allows for real time plant status information to easily be accessed in the control room, field workers’ computer-based procedures can be updated based on the real time plant status, and status on ongoing procedures can be incorporated into smart schedules in the outage command center to allow for more accurate planning of critical tasks. The goal of the digital architecture project is to provide a long-term strategy to integrate plant systems, plant processes, and plant workers. This include technologies to improve nuclear worker efficiency and human performance; to offset a range of plant surveillance and testing activities with new on-line monitoring technologies; improve command, control, and collaboration in settings such as outage control centers and work execution centers; and finally to improve operator performance with new operator aid technologies for the control room. The requirements identified through the activities in the Digital Architecture project will be used to estimate the amount of traffic on the network and hence estimating the minimal bandwidth needed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Remote operation of the DIII-D National Fusion Facility

Abstract Full remote scientific operation of the DIII-D National Fusion Facility is now possible through significant advances in the computer science hardware and software infrastructure made over the last decade. Capabilities around information visualization, data movement, and communication have all been enhanced. The level of capability deployed to remotely operate DIII-D required an infrastructure advancement over what had previously been achieved in the fusion community. The large quantity of real-time data that is automatically displayed on DIII-D’s control room screens can now be visualized by remote participants via web-based applications. New audio/video solutions using the VoIP and instant messaging application Discord have been implemented to mimic the dynamic and ad-hoc scientific conversations that are critical in successfully operating an experimental campaign. Discord’s ability for a user to rapidly move between audio channels, text with images, and share screens is a significant enhancement over traditional videoconferencing tools. In addition, multiple combinations of broadcast audio are made available via a web-based application to allow remote participants to simultaneously listen to general announcements/sounds while conducting their own specific conversations. Secure methodologies have been put into place to allow remote control of hardware including DIII-D’s plasma control system application. Secure methods also included the ability of the on-site team to closely coordinate their work with remote team members which has been enhanced through extensions to the wireless network and the use of tablet computers for audio/video/screen sharing. However, no amount of software can fully replace the need for ‘hands on hardware.’ This infrastructure was severely stress tested during the COVID-19 pandemic where occupancy of the DIII-D control room was restricted. Operational efficiency during the pandemic, measured in discharges per hour, remained high (3.8 ± 0.8) compared to values obtained pre-pandemic (3.7 ± 0.8).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhancing Power Plant Safety through Coupling Plant Simulators to Cyber Digital Architecture

There are differences in how cyber-attack, sabotage, or discrete component failure mechanisms manifest within power plants and what these events would look like within the control room from an operator's perspective. This research focuses on understanding how a cyber event would affect the operation of the plant, how an operator would perceive the event, and if the operator's actions based on those perceptions will allow him/her to maintain plant safety. This research is funded as part of Sandia's Laboratory Directed Research and Development (LDRD) program to develop scenarios with cyber induced failure of plant systems coupled with a generic pressurized water reactor plant training simulator. The cyber scenario s w ere developed separately and injected into the simulator operational state to simulate an attack. These scenarios will determine if Nuclear Power Plant (NPP) operators can 1) recognize that the control room indicators were presenting incorrect or erroneous information and 2) take appropriate actions to keep the plant safe. This will also provide the opportunity to assess the operator cognitive workload during such events and identify where improvements might be made. This paper will review results of a pilot study run with NPP operators to investigate performance under various cyber scenarios. The discussion will provide an overview of the approach, scenario selection, metrics captured, resulting insights into operator actions and plant response to multiple scenarios of the NPP system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

TAXI Direct-to-Disk Interface Demultiplexes Proprietarily Formatted Data

The TAXI Direct-to-Disk interface is a special-purpose interface circuit for demultiplexing of data from a Racal Storeplex (or equivalent) multichannel recorder onto one or more hard disks that reside in, and/or are controlled by, a personal computer (PC). (The name TAXI as used here is derived from the acronym TAXI, which signifies transparent asynchronous transceiver interface.) The TAXI Direct-to-Disk interface was developed for original use in capturing data from instrumentation on a test stand in a NASA rocket-testing facility. The control, data-recording, and data-postprocessing equipment of the facility are located in a control room at a safe distance from the test stand. Heretofore, the transfer of data from the instrumentation to the postprocessing equipment has entailed post-test downloading via software, requiring many hours to days of post-test reduction before the data could be viewed in a channelized format. The installation of the TAXI Direct-to-Disk interface, in conjunction with other modifications, causes the transfer of data to take place in real time, so that the data are immediately available for review during or after the test. The instrumentation is connected to the input terminals of the signal-processing unit of multichannel recorder by standard coaxial cables. The coaxial output of the signal processing unit is converted to fiber-optic output by means of a commercial coaxial-cable/fiber-optic converter (that is, a fiber-optic transceiver) designed specifically for this application. The fiber-optic link carries the data signals to an identical fiber-optic transceiver in the control room. On the way to the TAXI Direct-to-Disk interface that is the focus of this article, the data signals are processed through a companion special purpose circuit denoted by the similar name parallel TAXI interface.

Newnan, Bruce G.↗

Real-Time Early Warning Techniques

Contemporary approaches to aerospace vehicle system monitoring rely heavily on thresholds that represent a compromise between providing warning early enough to avert a mishap while simultaneously minimizing false alarms. While this reliance on thresholds has been in place for decades and has permeated both cockpits and control rooms, we often find it insufficient when retrospectively analyzing data from an accident. To modernize and enhance flight test safety, we introduce new methods of monitoring for anomalous patterns of interaction rather than for thresholds exceedance. For systems with a well characterized baseline we show how the Inductive Monitoring System (IMS), utilized by NASA in the aftermath of the Columbia accident, might be implemented in real-time to provide earlier warning than currently employed techniques. For systems without such a baseline, we introduce new developments in statistical methods relating to critical slowing down, first applied in medicine and physics, which show promise for adaptation to flight test. Finally, the familiar resource constrained environment leads to a reliance on increased instrumentation that is challenging the limits of the current one-sensor, one-indicator threshold paradigm. Existing methods thus fail to accurately reflect the true complexity of a vehicle rich with interdependent interacting systems. We highlight these concepts in a brief summary of the 2001 Air Transat Flight 236 deadstick landing in the Azores. We then suggest control room and cockpit modifications to better display the information gleaned using these novel monitoring methods.

Javorsek, Dan↗

Enhancing Flight Test Safety with Real-Time Early Warning Techniques

Contemporary approaches to aerospace vehicle system monitoring rely heavily on thresholds that represent a compromise between providing warning early enough to avert a mishap while simultaneously minimizing false alarms. While this reliance on thresholds has been in place for decades and has permeated both cockpits and control rooms, we often find it insufficient when retrospectively analyzing data from an accident. To modernize and enhance flight test safety, we introduce new methods of monitoring for anomalous patterns of interaction rather than for thresholds exceedance. For systems with a well characterized baseline we show how the Inductive Monitoring System (IMS), utilized by NASA in the aftermath of the Columbia accident, might be implemented in real-time to provide earlier warning than currently employed techniques. For systems without such a baseline, we introduce new developments in statistical methods relating to critical slowing down, first applied in medicine and physics, which show promise for adaptation to flight test. Finally, the familiar resource constrained environment leads to a reliance on increased instrumentation that is challenging the limits of the current "one-sensor, one-indicator" threshold paradigm. Existing methods thus fail to accurately reflect the true complexity of a vehicle rich with interdependent interacting systems. We highlight these concepts in a brief summary of the 2001 Air Transat Flight 236 deadstick landing in the Azores. We then suggest control room and cockpit modifications to better display the information gleaned using these novel monitoring methods.

Javorsek, Daniel, II↗

National Ignition Facility Control and Information System Operational Tools

The National Ignition Facility (NIF) in Livermore, California, is the world's highest-energy laser fusion system and one of the premier large scale scientific projects in the United States. The system is designed to setup and fire a laser shot to a fusion ignition or high energy density target at rates up to a shot every 4 hours. NIF has 192 laser beams delivering up to 1.8 MJ of energy to a {approx}2 mm target that is planned to produce >100 billion atm of pressure and temperatures of >100 million degrees centigrade. NIF is housed in a ten-story building footprint the size of three football fields as shown in Fig. 1. Commissioning was recently completed and NIF will be formally dedicated at Lawrence Livermore National Laboratory on May 29, 2009. The control system has 60,000 hardware controls points and employs 2 million lines of control system code. The control room has highly automated equipment setup prior to firing laser system shots. This automation has a data driven implementation that is conducive to dynamic modification and optimization depending on the shot goals defined by the end user experimenters. NIF has extensive facility machine history and infrastructure maintenance workflow tools both under development and deployed. An extensive operational tools suite has been developed to support facility operations including experimental shot setup, machine readiness, machine health and safety, and machine history. The following paragraphs discuss the current state and future upgrades to these four categories of operational tools.

42 ENGINEERING↗

3D Modeling of Safety-Related Upgrade Pilot Project

Constellation Energy and the United States Department of Energy (DOE) have established a public/private partnership to implement a pilot digital upgrade to replace legacy analog, safety-related reactor protection and emergency safety feature actuation systems (RPS/ESFAS) with modern digital systems. This effort is occurring at Constellation’s Limerick Generating Station. This project is being performed in accordance with industry processes that have been adapted to better support digital upgrades. These processes include IP-ENG-001, Standard Design Process, NISP-EN-04, Standard Digital Engineering Process and Electric Power Research Institute Report 3002011816, Digital Engineering Guide. The Light Water Reactor Sustainability (LWRS) Program at the Idaho National Laboratory (INL) has been supporting this effort. Latest INL HFE efforts in support of this project have focused on definition and implementation of the Human Factors Engineering (HFE) Program in support of Constellation design and related licensing efforts. This paper will present the development of the HFE 3D modeling execution of the Main Control Room safety upgrades. New equipment and modifications are planned for upgrading the new safety systems. 3D modeling allows for visualization of the new equipment and modifications to be shared with engineering and design teams for evaluation and review. Anthropometric considerations such as sight lines and functional reach can be evaluated directly using the 3D model. This effort has helped to provide visualizations for additional review with operations personnel and project stakeholders.

3D Modeling↗