Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “conservative loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Analysis of aerothermal loads on spherical dome protuberances

Hypersonic flow over spherical dome protuberances was investigated to determine increased pressure and heating loads to the surface. The configuration was mathematically modeled in a time-dependant three-dimensional analysis of the conservation of mass, momentum (Navier-Stokes), and energy equations. A boundary mapping techique was used to obtain a rectangular parallelepiped computational domain, and a MacCormack explicit time-split predictor-corrector finite difference algorithm was used to obtain solutions. Results show local pressures and heating rates for domes one-half, one, and two boundary layer thicknesses high were increased by factors on the order of 1.4, 2, and 6, respectively. However, because lee-side pressure and thermal loads were reduced the two lower height domes did not experience any net increase in total loads. The total loads on the higher dome were increased by twenty-five percent. Flow over the lower dome was everywhere attached while flow over the intermediate dome had small windward and leeside separations. The higher dome had an unsteady windward separation region and a large leeside separation region. Trailing vortices form on all domes with intensity increasing with dome height. Discussions of applying the results to a thermally bowed thermal protection system are presented.

Olsen, G. C.↗

Heat Pumps and the Electrification of Heating

70 to 80% of building energy load in Alaska is heating. About 81% of residential heating is supplied via on-site combustion of fossil fuels. How can heat pumps provide heat energy from renewable sources?

Alaska↗

Airport Ground Support Equipment Analysis

Ground support equipment (GSE) plays a critical role in providing services to aircraft at arrival and departure gates, ensuring smooth and efficient airport operations. As the airline industry seeks to reduce costs and expand energy options, electric GSE (eGSE) is emerging as a promising solution. This project examines the integration of eGSE into airport operations, addressing key considerations such as vehicle deployment, charging infrastructure, and grid impacts. We developed a flexible, bottom-up modeling framework to evaluate energy demands and infrastructure requirements across more than 300 U.S. airports, providing actionable insights to support electrification planning and implementation. The study focuses on eight major types of GSE with commercially available electric counterparts: aircraft tractors, ground power units, baggage tractors, belt loaders, cargo loaders, catering trucks, lavatory trucks, and water trucks. Project results include annual charging load profiles, total energy consumption, and the charger and fleet requirements for each airport.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GSE Yearly Load Profiles for Each Airport Under Six Charging Scenarios

This dataset contains GSE yearly load profiles for each airport under six charging scenarios: (1) charging when the battery state of charge is insufficient for the next service using 40-kW chargers (S1); (2) charging when the battery state of charge is insufficient for the next service using 20-kW chargers (S2); (3) charging starts immediately after each GSE completes a service task using 40-kW chargers (S3); (4) charging starts immediately after each GSE completes a service task using 20-kW chargers (S4); (5) charging during off-peak hours using 40-kW chargers (S5); and (6) charging during off-peak hours using 20-kW chargers (S6). ![image](gse_load_profile_sample_day.png) GSE load profile of a sample day across different airport categories under charging scenario 1.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An iterative bidirectional gradient boosting approach for CVR baseline estimation

Here this paper presents a novel Iterative Bidirectional Gradient Boosting Model (IBi-GBM) for estimating the baseline of Conservation Voltage Reduction (CVR) programs. In contrast to many existing methods, we treat CVR baseline estimation as a missing data retrieval problem. The approach involves dividing the load and its corresponding temperature profiles into three periods: pre-CVR, CVR, and post-CVR. To restore the missing load profile during the CVR period, the method employs a three-step process. First, a forward-pass GBM is executed using data from the pre-CVR period as inputs. Subsequently, a backward-pass GBM is applied using data from the post-CVR period. The two restored load profiles are reconciled, considering pre-calculated weights derived from forecasting accuracy, and only the leftmost and rightmost points are retained. The newly restored points are then included as inputs for the subsequent iteration. This iterative procedure continues until the original load data in the CVR period is fully restored. We develop IBi-GBM using actual smart meter and Supervisory Control and Data Acquisition (SCADA) data. Our results demonstrate that IBi-GBM exhibits robust performance across various data resolutions and in different seasons and outperforms existing methods by achieving a 1-2% reduction in normalized Root Mean Square Error (nRMSE).

42 ENGINEERING↗

Supersonic flutter of panels loaded with inplane shear

A modal flutter analysis for biaxially loaded, orthotropic panels, using linear piston-theory aerodynamics, was extended in order to include the effects of inplane shear loading. Flutter boundaries for shear loads up to buckling are calculated for simply supported, isotropic panels of various length-width ratios and for a square, isotropic panel with elastic boundary conditions along the leading and trailing edges. These flutter boundaries are used to define conservative design curves. Sample calculations made using these design curves indicate that practical panels, which have otherwise been adequately designed, could become flutter critical if the inplane shear loads approach the buckling value.

Sawyer, J. W.↗

PANDEMIC: Occupancy driven predictive ventilation control to minimize energy consumption and infection risk

During the SARS-CoV-2 (COVID-19) pandemic, governments around the world have formulated policies requiring ventilation systems to operate at a higher outdoor fresh air flow rate for a sufficient time, which has led to a sharp increase in building energy consumption. Therefore, it is necessary to identify an energy-efficient ventilation strategy to reduce the risk of infection. In this study, we developed an occupant-number-based model predictive control (OBMPC) algorithm for building ventilation systems. First, we collected the occupancy and Heating, ventilation, and air conditioning system (HVAC) data from March to July 2021. Then, four different models (Auto regression moving average-based multilayer perceptron (ARMA_MLP), Recurrent neural networks (RNN), Long short-term memory networks (LSTM), and Nonhomogeneous Markov with change points detection (NH_Markov)) were used to predict the number of room occupants from 15 min to 24 h ahead with an interval output. We found that each model could predict the number of occupants with 85% accuracy using a one-person offset. Furthermore, the accuracy of 15 min of the ahead prediction could reach 95% with a one-person offset, but none of them could track abrupt changes. The occupancy prediction results were used to calculate the ventilation demand using the Wells-Riley equation, and the upper bound can maintain an infection risk lower than 2% for 93% of the day. This OBMPC model could reduce the coil load by 52.44% and shift the peak load by 3 h up to 5 kW compared with 24 × 7 h full outdoor air (OA) system when people wear masks in the space. The occupancy prediction uncertainty could cause a 9% to 26% difference in demand ventilation, a 0.3°C to 2.4°C difference in zone temperature, a 28.5% to 44.5% difference in outdoor airflow rate, and a 10.7% to 28.2% difference in coil load.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flight Arrival Data for Each Airport

This dataset contains flight arrival data for each airport, which serves as the input for generating load profiles and estimating energy needs and fleet and charger requirements. ![image](distribution-flight-arrivals.png) Distribution of annual flight arrivals across different airport categories.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of Load Models for Estimating Electrical Efficiency in DC Microgrids: Preprint

This paper compares several electrical load models for estimating the efficiency of DC vs. AC distribution in microgrids. Candidate models include energy balance, harmonic power flow, and time-domain modeling. Model results are compared with numerical studies and validated with experimental measurements. Based on quantitative and qualitative considerations, the most appropriate load modeling approach for larger-scale DC distribution efficiency studies is proposed.

DC distribution↗

A new database of building-space-specific internal loads and load schedules for performance based code compliance modeling of commercial buildings

Building-level loads and load profiles prescribed by current modeling rules save modelers time and avoid gaming during whole building performance modeling. However, recent studies show that they sometimes insufficiently capture the entire building performance due to the varied loads and load profiles for different space types. As a solution to this issue, this paper develops a database of building-space-specific loads and load profiles used in code compliance modeling. The existing sets of loads and load profiles are reviewed and the challenges behind using them for specific research topics are discussed. Then, the proposed method to develop the building-space-specific loads and load profiles is introduced. After that, the database for these building-space-specific loads and load profiles is presented. In addition, one case is studied to demonstrate the applications of these loads and load profiles. In this case study, three methods are used to develop building energy models: space-specific (using knowledge of the distribution and location of space types and applying the space-specific data in the developed database), building-level (assuming a lack of knowledge of the space types and using the building-level data in the developed database), and calculated-ratio (assuming knowledge of the distribution of space types but not their locations and calculating weighted average values based on the space-specific data in the developed database). Finally, the energy results simulated by using these three methods are compared, which show building-level methods can produce energy results up to 20% different than the space-specific methods. Finally, this paper discusses the application scope and maintenance of this new database.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modulating thermal load through lightweight residential building walls using thermal energy storage and controlled precooling strategy

Precooling is a recognized technique for reducing cooling energy in buildings during peak hours by shifting load to off-peak hours. This technique is particularly effective in buildings with high thermal mass, because of their large thermal energy storage capacity, and in commercial buildings due to their variable electricity pricing based on time-of-use rates. Precooling in residential buildings has been a matter of limited interest in the past because of their low thermal mass and typically uniform electricity pricing rate. While previous studies on precooling primarily focused on cost savings, an important aspect of precooling is the thermal load modulation, which could be very effective in managing peak demand in lightweight residential buildings integrated with thermal energy storage systems. In this study, we examine different precooling strategies to manage the heat gains in lightweight building walls integrated with phase-change materials. We create nine different precooling profiles by controlling the interior temperature, and then evaluate the influence of the precooling profiles on four key building energy performance parameters: total heat gain, peak heat gain, maximum heat gain during peak hours, and time at which peak occurs. To thoroughly understand the fundamental physics, we first consider hypothetical climates and obtain the optimal precooling strategy required to achieve maximum peak shedding and shifting while minimizing the total heat gains. We then extend the model to Baltimore, Maryland, and estimate the benefits of the optimized precooling strategy under real conditions. The optimal precooling strategy proposed in this study can shift the peak heat gain by up to 14 hours, thereby reducing the heat gain during peak period by up to 95%, at the expense of a 23% increase in the total heat gains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy use of residential safety, security, and health devices

Miscellaneous electrical loads (MELs) are responsible for a significant fraction of energy consumption in buildings. This paper addresses one category of MELs: Safety, Security, and Health Devices (SSHDs). Common SSHDs include: electrical life safety equipment, smoke alarms, radon mitigation fans, and home oxygen concentrators. The installation or use of these devices is dictated by building codes, health providers, insurance companies, and other entities—none of which would ordinarily consider energy efficiency a priority. For this project, the most important residential devices were explored in terms of their governing regulations, functions, technologies, and energy use. The power consumption of 41 life safety SSHDs were measured. Individual power consumption of life safety devices is very small but many are typically required in every home. Devices performing the same functions have wide ranges in power use. Opportunities for reducing SSHD energy use were investigated, the results are summarized, and recommendations are made for further actions that could be taken to reduce SSHD energy use. Finally, SSHDs identified in this paper are responsible for at least one percent of current U.S. residential electricity consumption, but that number will climb steadily as existing buildings are upgraded and new types of SSHDs appear.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and analysis of a stiffened composite fuselage panel

The design and analysis of stiffened composite panel that is representative of the fuselage structure of existing wide bodied aircraft is discussed. The panel is a minimum weight design, based on the current level of technology and realistic loads and criteria. Several different stiffener configurations were investigated in the optimization process. The final configuration is an all graphite/epoxy J-stiffened design in which the skin between adjacent stiffeners is permitted to buckle under design loads. Fail safe concepts typically employed in metallic fuselage structure have been incorporated in the design. A conservative approach has been used with regard to structural details such as skin/frame and stringer/frame attachments and other areas where sufficient design data was not available.

Dickson, J. N.↗

Power electronics for low power arcjets

In anticipation of the needs of future light-weight, low-power spacecraft, arcjet power electronics in the 100 to 400 W operating range were developed. Limited spacecraft power and thermal control capacity of these small spacecraft emphasized the need for high efficiency. Power topologies similar to those in the higher 2 kW and 5 to 30 kW power range were implemented, including a four transistor bridge switching circuit, current mode pulse-width modulated control, and an output current averaging inductor with an integral pulse generation winding. Reduction of switching transients was accomplished using a low inductance power distribution network, and no passive snubber circuits were necessary for power switch protection. Phase shift control of the power bridge was accomplished using an improved pulse width modulation to phase shift converter circuit. These features, along with conservative magnetics designs allowed power conversion efficiencies of greater than 92.5 percent to be achieved into resistive loads over the entire operating range of the converter. Electromagnetic compatibility requirements were not considered in this work, and control power for the converter was derived from AC mains. Addition of input filters and control power converters would result in an efficiency of on the order of 90 percent for a flight unit. Due to the developmental nature of arcjet systems at this power level, the exact nature of the thruster/power processor interface was not quantified. Output regulation and current ripple requirements of 1 and 20 percent respectively, as well as starting techniques, were derived from the characteristics of the 2 kW system but an open circuit voltage in excess of 175 V was specified. Arcjet integration tests were performed, resulting in successful starts and stable arcjet operation at power levels as low as 240 W with simulated hydrazine propellants.

Hamley, John A.↗

Power electronics for low power arcjets

In anticipation of the needs of future light-weight low-power spacecraft, arcjet power electronics in the 100- to 400-W operating range were developed. Power topologies similar to those in the higher 2-kW and 5- to 30-kW power range were implemented, including a four-transistor bridge-switching circuit, current-mode pulse-width modulated control, and an output current averaging inductor with an integral pulse generation winding. Reduction of switching transients was accomplished using a low inductance power distribution network, and no passive snubber circuits were necessary for power switch protection. Phase shift control of the power bridge was accomplished using an improved pulse width modulation to phase shift converter circuit. These features, along with conservative magnetics designs, allowed power conversion efficiencies of greater than 92.5 percent to be achieved into resistive loads over the entire operating range of the converter.

Hamley, John A.↗

Part 1 of a Computational Study of a Drop-Laden Mixing Layer

This first of three reports on a computational study of a drop-laden temporal mixing layer presents the results of direct numerical simulations (DNS) of well-resolved flow fields and the derivation of the large-eddy simulation (LES) equations that would govern the larger scales of a turbulent flow field. The mixing layer consisted of two counterflowing gas streams, one of which was initially laden with evaporating liquid drops. The gas phase was composed of two perfect gas species, the carrier gas and the vapor emanating from the drops, and was computed in an Eulerian reference frame, whereas each drop was tracked individually in a Lagrangian manner. The flow perturbations that were initially imposed on the layer caused mixing and eventual transition to turbulence. The DNS database obtained included transitional states for layers with various liquid mass loadings. For the DNS, the gas-phase equations were the compressible Navier-Stokes equations for conservation of momentum and additional conservation equations for total energy and species mass. These equations included source terms representing the effect of the drops on the mass, momentum, and energy of the gas phase. From the DNS equations, the expression for the irreversible entropy production (dissipation) was derived and used to determine the dissipation due to the source terms. The LES equations were derived by spatially filtering the DNS set and the magnitudes of the terms were computed at transitional states, leading to a hierarchy of terms to guide simplification of the LES equations. It was concluded that effort should be devoted to the accurate modeling of both the subgridscale fluxes and the filtered source terms, which were the dominant unclosed terms appearing in the LES equations.

Okong'o, Nora A.↗

Design of Phase-Change Thermal Storage Device in a Heat Pump for Building Electric Peak Load Shaving: Preprint

Replacing carbon-intensive fossil fuel heating systems with electric heat pumps powered by renewables is a promising approach to decarbonize the building sector. However, one of the technical barriers of this approach is the large scale of heat demand, which will put excessive stress on the electricity grid. Integrating thermal energy storage (TES) into the heating systems can help alleviate this problem, by shifting thermal load and thus shaving peaks in the building electric load. Therefore, it is critical to understand how to design a thermal storage device in a heat pump for peak load shaving. In this study, we developed a numerical model for a cascaded vapor compression heat pump system integrating a phase change thermal storage device. This novel system can control the net thermal charging and discharging rate of the TES independently from the building's thermal load, which allows for precise control of electric power use. In the current study, we controlled the system to shave building electric peak load during a cold winter morning, and to charge TES during the relatively warm afternoon while still providing space heating. We used the model to evaluate the system performance with and without peak shaving. We also investigated the effect of PCM transition Tt on the peak reduction and electric energy saving potentials. The results show that peak shaving scheme effectively reduces the peak electric power consumption during a predefined discharge time window. When comparing to the no shaving case, for PCM Tt = 10 degrees C, the peak electric load reduction is 23.5%. When comparing to an air-source heat pump with back up electric heater, as Tt increases from 0 to 20 degrees C, the peak reduction increases from 46.1% to 50.9%. Integrating PCM Tt = 10 degrees C with peak shaving leads to the 45.5% of electric energy saving, which is the highest among the three transition temperatures.

electric energy saving↗

Broadly neutralizing humanized SARS-CoV-2 antibody binds to a conserved epitope on Spike and provides antiviral protection through inhalation-based delivery in non-human primates

The COVID-19 pandemic represents a global challenge that has impacted and is expected to continue to impact the lives and health of people across the world for the foreseeable future. The rollout of vaccines has provided highly anticipated relief, but effective therapeutics are required to further reduce the risk and severity of infections. Monoclonal antibodies have been shown to be effective as therapeutics for SARS-CoV-2, but as new variants of concern (VoC) continue to emerge, their utility and use have waned due to limited or no efficacy against these variants. Furthermore, cumbersome systemic administration limits easy and broad access to such drugs. As well, concentrations of systemically administered antibodies in the mucosal epithelium, a primary site of initial infection, are dependent on neonatal Fc receptor mediated transport and require high drug concentrations. To reduce the viral load more effectively in the lung, we developed an inhalable formulation of a SARS-CoV-2 neutralizing antibody binding to a conserved epitope on the Spike protein, ensuring pan-neutralizing properties. Administration of this antibody via a vibrating mesh nebulization device retained antibody integrity and resulted in effective distribution of the antibody in the upper and lower respiratory tract of non-human primates (NHP). In comparison with intravenous administration, significantly higher antibody concentrations can be obtained in the lung, resulting in highly effective reduction in viral load post SARS-CoV-2 challenge. This approach may reduce the barriers of access and uptake of antibody therapeutics in real-world clinical settings and provide a more effective blueprint for targeting existing and potentially emerging respiratory tract viruses.

60 APPLIED LIFE SCIENCES↗