Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “condensation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Condensers and electronic assemblies

Provided is a condenser for use in an electronic assembly. The condenser includes a first vertical wall extending in a vertical direction, the first vertical wall defining a first plurality of vertical condensation channels within the first vertical wall, a second vertical wall extending in the vertical direction, the second vertical wall defining a second plurality of vertical condensation channels within the second vertical wall, and a first plurality of fins extending in the vertical direction, each of the first plurality of fins connected to the first vertical wall, the second vertical wall or both the first vertical wall and the second vertical wall.

Cousineau, Emily↗

Experimental Evaluation of a Microchannel Condenser for R600a Domestic Refrigerators

Domestic refrigerators are among the most common household appliances, accounting for approximately 4% of total household energy consumption, which is higher than that of clothes dryers, lighting, or cooking appliances. With nearly 13 million new domestic refrigerators sold annually, even marginal improvements in their energy performance can yield significant reductions in overall energy demand and cost. This study focuses on enhancing the performance of domestic refrigerators using R600a as the refrigerant. Most domestic refrigerators currently employ wire-and-tube condensers, which are bulky and require a larger refrigerant charge. Given that R600a is classified as an A3 flammable refrigerant under ASHRAE standards, minimizing the system charge while maintaining or improving performance is critical. To address this, a compact and light weight single-pass serpentine microchannel heat exchanger (made of aluminum) was adopted as a condenser, replacing the conventional wire-and-tube configuration. The modified system was experimentally tested according to AHAM test standards, and charge optimization was performed. The results demonstrated that the refrigerator equipped with the microchannel condenser achieved a 5.3% reduction in energy consumption compared to the baseline configuration with wire-and-tube condenser.

Murugan, Muneeshwaran [ORNL] (ORCID:00000003340352↗

Dispersion Loss Counteracts Embedding Condensation and Improves Generalization in Small Language Models

Large language models (LLMs) achieve remarkable performance through ever-increasing parameter counts, but scaling incurs steep computational costs. To better understand LLM scaling, we study representational differences between LLMs and their smaller counterparts, with the goal of replicating the representational qualities of larger models in smaller models. We observe a geometric phenomenon which we term embedding condensation, where token embeddings collapse into a narrow cone-like subspace in some language models. Through systematic analyses across multiple Transformer families, we show that small models such as GPT2 and Qwen3-0.6B exhibit severe condensation, whereas larger models such as GPT2-x1 and Qwen3-32B are more resistant to this phenomenon. Additional observations show that embedding condensation is not reliably mitigated by knowledge distillation from larger models. To fight against it, we formulate a dispersion loss that explicitly encourages embedding dispersion during training. Experiments demonstrate that it mitigates condensation, recovers dispersion patterns seen in larger models, and yields performance gains across 10 benchmarks. We believe this work offers a principled path toward improving smaller Transformers without additional parameters.

Xiao, Xi [ORNL] (ORCID:0009000009316982)↗

Impacts of common faults on an air conditioner with a microtube condenser and analysis of fault characteristic features

Split system air conditioners are widely used to cool residential buildings, because of their low cost and simplicity. However, their efficiency is impacted by installation faults, which include: improper refrigerant charge (undercharge or overcharge), improper evaporator airflow, liquid line restrictions (LL), and the presence of non-condensable gas (NC) in the refrigerant. No known previously published research has studied the effect of these four faults on a system equipped with a microtube condenser, which has smaller tube size than a traditional condenser and therefore holds less refrigerant charge, but has a different configuration than a microchannel. Furthermore, very few have studied the impacts of LL and NC. Herein this paper describes laboratory fault tests of a microtube-equipped system, compares the fault impacts with those of a traditional system, and considers the characteristic fault features. The tested system uses R-410A refrigerant and has a scroll compressor, a fixed orifice expansion device, and two fin-tube heat exchangers. The tests were carried out under steady operation with a range of fault intensities and operating conditions. The microtube system’s performance degradation from faults is similar to systems with traditional heat exchangers, despite the reduced capacity to hold refrigerant charge.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nanostructured $\mathrm{GaAs/(Al,Ga)As}$ Waveguide for Low-Density Polariton Condensation from a Bound State in the Continuum

Exciton-polaritons are hybrid light-matter states that arise from strong coupling between an exciton resonance and a photonic cavity mode. As bosonic excitations, they can undergo a phase transition to a condensed state that can emit coherent light without a population inversion. This aspect makes them good candidates for thresholdless lasers, yet short exciton-polariton lifetime has made it difficult to achieve condensation at very low power densities. In this sense, long-lived symmetry-protected states are excellent candidates to overcome the limitations that arise from the finite mirror reflectivity of monolithic microcavities. In this work we use a photonic symmetry-protected bound state in the continuum coupled to an excitonic resonance to achieve state-of-the-art polariton condensation threshold in a GaAs/(Al,Ga)As waveguide. Most important, we show the influence of fabrication control and how surface passivation via atomic layer deposition provides a way to reduce exciton quenching at the grating sidewalls.

74 ATOMIC AND MOLECULAR PHYSICS↗

Partial support of the Condensed Matter and Materials Research Committee. Final progress report

The Condensed Matter and Materials Research Committee (CMMRC) is one of five standing committees of the National Academies’ Board on Physics and Astronomy (BPA) and is charged with assisting the BPA in achieving its goals—monitoring the health of physics and astronomy, identifying important new developments at the scientific forefronts, fostering interactions with other fields, strengthening connections to technology, facilitating effective service to the nation, and enhancing education in physics. CMMRC carries out its functions in several ways – providing expert advice to the BPA in monitoring the health of condensed matter and materials research and providing perspective on issues that arise in those fields; assisting other National Academies’ boards in developing proposals and initiating studies that impact these fields; providing long-term stewardship of National Academies reports that it has played a role in initiating and that are of importance to the condensed matter and materials research communities, and providing a means for dialog with federal agencies on these and related fields.

36 MATERIALS SCIENCE↗

Furfural Upgrading by Aldol Condensation with Ketones over Solid-Base Catalysts

Aldol condensation reactions between furfural and various ketones were studied in a flow reactor at 373 K and 100 psi for application to upgrading of furfural. Specific rates for the reaction of acetone and furfural were measured on MgAl 2 O 4 , Al 2 O 3 , CaO/MgAl 2 O 4 and MgO/MgAl 2 O 4 and found to be highest on CaO/MgAl 2 O 4 . While the presence of CO 2 and H 2 O did not affect the stability of the CaO/MgAl 2 O 4 catalyst, the catalyst deactivated over a period of a few hours due to the production of 2-furoic acid formed by the Cannizzaro reaction. While aldol condensation rates between furfural and either 2-pentanone and decanal approached that of acetone, rates for 4-heptanone and 2,5-heptanedione were significantly lower because the α-hydrogens of the carbonyl compounds are less easily attacked in these molecules. The selectivity to aldol products is affected by the relative rates of the aldol-condensation and the Cannizzaro reactions. Possible strategies for maximizing production of the aldol products with larger ketones are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Condensation heat transfer and pressure drop of low-global warming potential refrigerants in smooth aluminum tubes

In this work we report condensation heat transfer coefficient and pressure drop data for R-454B, R-32, and R-454C. These refrigerants are low Global Warming Potential (GWP) replacements for R-410A. We obtained these data in a smooth 7.2 mm outer diameter (5.94 mm inner diameter) aluminum tube. In these experiments, the key variables were condensation temperature (35 °C ≤ T cond ≤ 50 °C) and refrigerant mass flux (151.1 ≤ G ≤ 347.3 kg m –2 s –1 ). In general, for similar nominal operating conditions, we measured the highest heat transfer coefficients for R-32 and the lowest for R-454C. Among the correlations we used to predict the heat transfer data for all three refrigerants, the one developed by Thome et al. (2003) predicted the data with the greatest accuracy. Deviations between experimental data and predictions of this correlation were 21.7% for R-454B (with SBG correction), 22.0% for R-32, and 18.8% for R-454C (with SBG correction). Experimental pressure gradient data were predicted by the Friedel correlation Friedel (1979) with deviations of 13.8% for R-454B, 9.8% for R-32, and 10.2% for R-454C. In this work, we also compare the predictions of the Cavallini et al. correlation Cavallini et al. (2006) for R-454B and R-32 in smooth copper versus smooth aluminum tubes. To improve this correlation’s predictive capability for aluminum tubes, we have proposed some modifications. After incorporating these modifications, the deviations between the correlation’s predictions and our data were 10% for R-454B (with SBG correction), 8.1% for R-32, and 5.2% for R-454C (with SBG correction). Furthermore, these data and findings will assist the HVAC and refrigeration industry to implement low-GWP refrigerants in condensers using smooth aluminum tubes.

Aluminum tube↗

Porous condensers can double the efficiency of membrane distillation

Among membrane distillation (MD) configurations, air gap MD (AGMD) has superior energy efficiency at high salinity. However, flooding of the gap prevents optimal thin gap depths as water removal is a challenge. To address these challenges, this work provides the first analysis of efficiency enhancement via porous wicking conductive condensers in MD. To do so, we examined performance with experiments and comprehensive thermo-fluid numerical models; we find that the porous wick condenser significantly improves thermal efficiency, gain output ratio (GOR), and flux. MD experiments show that the porous copper foam improves the thermal efficiency of air gap membrane distillation up to 40 % and water flux up to 144 %. Numerical modeling shows the porous copper foam improves the GOR of membrane distillation in high salinity by 98.7 %, outperforming air gap MD, permeate gap MD, and conductive gap MD. Furthermore, the optimized thickness and permeability of porous condensers significantly help eliminate the risk of flooding in AGMD.

42 ENGINEERING↗

Modeling and experimental validation of direct contact crossflow packed beds condenser used in HDH desalination systems

Humidification and dehumidification (HDH) desalination systems are alternatives to reverse osmosis desalination systems, especially for high salinity waters. A HDH system is essentially equipped with a humidifier (also called as evaporator) for air to pick up vapor from saline water, a dehumidifier (also called as condenser) to produce freshwater, and a heating source. HDH systems based on direct contact packed beds heat exchangers have remarkably lower costs than traditional HDH systems due to their inexpensive materials and simple configurations. This paper specifically focuses on direct contact crossflow packed beds condensers, in which cooling water vertically drips through the packed beds, directly contacting the horizontal air-vapor flow. A two-dimensional mathematical model that solves for the enthalpy values of the working fluids is proposed in this paper, and the PDEs are solved using finite differences. To validate the model, an experimental condenser was built and tested. Water temperatures inside the test section at twenty-nine locations were measured, as well as the air vapor temperatures of five locations at the outlet. The measured water and air-vapor temperatures agree with the simulation results with less than 10 % error in most of the compared domain.

42 ENGINEERING↗

Machine learning based simultaneous control of air handling unit discharge air and condenser water temperatures set-point for minimized cooling energy in an office building

In this study, an artificial intelligence based real-time prediction and control model to optimize condenser water temperature and discharge air temperature (DAT) set-points in water-cooled air handling unit (AHU) system has been developed. EnergyPlus-MATLAB co-simulation has been conducted to analyze the developed model's effectiveness. Here, to develop artificial neural networks (ANN) model, embedded neural network objects in MATLAB was utilized. The developed model could decide an optimal temperature set-points based on outdoor air wet-bulb temperature to reflect the Korean climate context. As a result, the developed ANN prediction model showed the predictive performance of Cv(RMSE) of approximately 21%. Compared to the conventional fixed temperature algorithm, which fixes AHU DAT at 14°C and condenser water temperature at 32°C, the ANN based optimized control showed a 22% total cooling energy reduction. These results show that significant energy savings can be achieved by simultaneously controlling condenser water temperature and AHU DAT set-points considering Korean climatic characteristics using AI technologies such as ANN models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

In Tube Condensation Heat Transfer and Pressure Drop for R454B and R32—Potential Replacements for R410A

The heating, ventilation and air conditioning (HVAC) industry in the United States seeks near-term alternative refrigerants to replace R-410A in unitary equipment. Two potential replacement refrigerants are R-454B and R-32. It is of interest to investigate the capability and accuracy of existing heat exchanger design methods when applied to these replacement refrigerants. To that end, this work presents empirical condensation quasi-local heat transfer coefficient and pressure drop data for R-454B and R-32. These data were obtained in a $\frac{3}{8}$ in. (9.52 mm) outside diameter (OD) smooth copper tube with a wall thickness of 0.032 in. (0.81 mm). The experimental variables and their ranges included refrigerant absolute pressure ( 1960 ≤ P a b s ≤ 3196 kPa), condensation temperature ( 35 ≤ T c o n d ≤ 50 °C), mass flux ( 100 ≤ G ≤ 200 kg m -2 s -1 ), vapor quality ( 0 ≤ x ≤ 1 ), and heat flux ( 32.9 ≤ q ″ ≤ 62.97 kW m -2 ). It was found that the heat transfer correlation developed by Cavallini et al. Cavallini et al. (2006) predicted the experimental condensation heat transfer data, for both R-454B and R-32, with the greatest accuracy. Using the Cavallini et al. correlation, it was found that the mean absolute percentage error (MAPE) was 10.5% and 15.1% for R-454B and R-32, respectively. Additionally, the pressure drop correlation developed by Friedel Friedel (1979) predicted the experimentally determined pressure gradient with a MAPE of 7.7% and 5.5% for R-454B and R-32, respectively. These results will assist the practicing thermal engineer to choose the most appropriate design correlation for these near-term replacement refrigerants.

42 ENGINEERING↗

Cross-aldol condensation on missing linker sites of metal–organic framework UiO-66

Missing linkers induce coordinatively unsaturated Lewis acid-base pair sites in metal–organic frameworks such as UiO-66 (Zr). The Lewis acid-base pair is induced by replacing the benzene dicarboxylic acid linker with formic acid, which subsequently is thermally decomposed. The concentration of coordinatively unsaturated Zr 4+ cations was titrated with acetone. In parallel to their concentration, the catalytic activity increased while the selectivity for aldol condensation between furfural and acetone remained constant. The missing linkers generate a complex ensemble consisting of an (at least partly) accessible Zr 4+ cation surrounded by oxygen, catalyzing the cross-aldol condensation. As a result, density functional theory calculations, matching the experimental findings provide a more detailed understanding of the elementary steps during the condensation reaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Benchmark of interfacial area concentration approaches for the two-fluid model in gas-dispersed condensing flow

Accurate predictions of interfacial area concentration (IAC) are required for closure of the condensation phase change term. The interfacial area transport equation (IATE) can dynamically predict interfacial area concentration and is increasingly being used in the benchmarking of phase change flows over static based correlations which require a flow regime map. For higher flow regimes, the two-group two-fluid IATE model can separately model the transport of spherical bubbles and cap/slug bubbles. Recently, a modified formulation of the one-group and two-group two-fluid model with interfacial area transport equation was proposed for gas-dispersed condensing flows. Three datasets have been used for validation consisting of condensing two-phase flow data in the unheated section of a vertical annulus with conditions spanning a range of pressures, inlet subcoolings and mass fluxes for benchmarking the various IAC approaches. For bubbly flows, the coupled void transport - IATE simulation results in good agreement in the predictions of the void fraction and the interfacial area concentration under nearly all sixty conditions. Considering the proposed two-group two-fluid IATE model formulation, the group-2 Nusselt number correlation is investigated to account for the appropriate heat transfer length scale for group-2 bubbles. Validation of the proposed two-group two-fluid model against the new dataset shows good agreement with experimental data with significant improvement over the one-group IATE model for conditions with substantial group-2 void fraction throughout the simulation domain.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Freeze range of a condensing gas propagating in a liquid helium-cooled tube

Understanding air propagation and condensation following a catastrophic vacuum break in particle accelerator beamlines cooled by liquid helium is crucial for maintaining the operational safety of these facilities. Previous experimental investigations on nitrogen gas propagation in both normal liquid helium (He I) and superfluid helium (He II) cooled copper tubes unveiled a nearly exponential deceleration of the gas propagation. A comprehensive theoretical model incorporating gas dynamics, heat transfer, and condensation mechanisms has been developed, which effectively reproduces various key experimental observations. An intriguing phenomenon uncovered in our model simulation is that the gas propagation appears to nearly stop beyond a certain distance from the location where condensation starts. We refer to this distance as the freeze range. In this paper, we present our systematic study of the freeze range at various inlet mass fluxes and tube diameters. We show that the results can be well described by a simple correlation. The underlying physical mechanism that supports this useful correlation is explained. Knowing the freeze range may allow accelerator engineers to develop protocols for controlling frost-layer contamination in the beamline tubes, which is of great practical importance.

43 PARTICLE ACCELERATORS↗

Experimental and Computational Studies of Carbon–Carbon Bond Formation via Ketonization and Aldol Condensation over Site-Isolated Zirconium Catalysts

We report here the preparation and investigation of isolated Zr centers supported on a high surface area silica for the conversion of carboxylic acids to internal ketones by ketonic decarboxylation (ketonization) and the aldol condensation of ketones to dimeric enones. Catalysts were synthesized by the grafting of Cp 2 ZrCl 2 on the surface of amorphous silica. The connectivity of Zr was characterized by XRD, UV-vis, and Raman spectroscopy. For the lowest Zr loading, Zr is present predominantly as isolated monomeric species. As the Zr loading is increased, a progressively larger fraction of Zr forms oligomeric species and ZrO nanoparticles. Measurements of catalytic activity show that the turnover frequency for carboxylic acid ketonic decarboxylation reaction and aldol condensation of ketones decreases monotonically with increasing Zr loading. An H/D kinetic isotope effect was not observed over isolated Zr catalysts, suggesting that α-H abstraction is not the rate-determining step, rather C-C bond forming may be rate limiting for both reactions. This conclusion is supported by computational modeling of the reaction mechanism. The proposed catalytic cycle for ketonization proceeds via a β-keto acid intermediate on isolated Zr sites that are always coordinatively saturated with C-C bond formation as the rate-limiting step. C-C bond formation is also rate-determining for aldol condensation, with an apparent activation energy that is in good agreement with the experiment if the resting state is a saturated ≡ZrOH site with two adsorbed ketone molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bose–Einstein condensation of a two-magnon bound state in a spin-1 triangular lattice

In ordered magnets, the elementary excitations are spin waves (magnons), which obey Bose–Einstein statistics. Similarly to Cooper pairs in superconductors, magnons can be paired into bound states under attractive interactions. The Zeeman coupling to a magnetic field is able to tune the particle density through a quantum critical point, beyond which a ‘hidden order’ is predicted to exist. Here, in this work, we report direct observation of the Bose–Einstein condensation of the two-magnon bound state in Na 2 BaNi(PO 4 ) 2 . Comprehensive thermodynamic measurements confirmed the two-dimensional Bose–Einstein condensation quantum critical point at the saturation field. Inelastic neutron scattering experiments were performed to establish the microscopic model. An exact solution revealed stable two-magnon bound states that were further confirmed by electron spin resonance and nuclear magnetic resonance experiments, demonstrating that the quantum critical point is due to the pair condensation, and the phase below the saturation field is likely the long-sought-after spin nematic phase.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Control of atomic Bose – Einstein condensate with interferometric feedback probing

We consider the problem of decoherence in a Bose – Einstein condensate (BEC) of noninteracting atoms during interferometric probing with a classical monochromatic external field. The condensate is located in one of the arms of the Mach – Zehnder interferometer, while part of the radiation from the interferometer output is fed back to the input, thereby closing the coherent feedback loop. A more general setting of the problem is also considered, in which the condensate is located in a system of interferometers ‘nested’ into each other, while part of the output radiation of each of them is also fed back to its input, closing the so-called multiloop feedback. The possibility of effective control of decoherence rates of various matrix elements is shown. The application of feedback of the proposed type to BEC in a double-well potential is investigated. It is found that this feedback allows efficient control of the distribution of atoms between the wells. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗