Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “command and control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Large-Scale Thermoset Pick and Place Testing and Implementation

Oak Ridge National Laboratory is developing the first commercially available medium to large-scale thermoset additive manufacturing (AM) system with Magnum Venus Products (MVP). This 3D printer is capable of fabricating large-scale thermoset components at room temperature with a build volume of 16’ x 8’ x 42’’. The thermoset extrusion process uses irreversible exothermic chemical reactions to form a cross-linked polymer. Printing thermosets at such large scales with highly customizable materials at room temperature provides huge opportunities for complex and smart tooling applications. Integrating a pick and place actuator into this system will allow for the placement of heating/cooling channels as well as sensors to monitor tooling health and heat distribution. The pneumatically-driven pick and place actuator is integrated into the existing electrical and mechanical design and is controlled using custom M-code commands. The system is comprised mostly of commercially available components, providing easy adoptability by future thermoset systems.

Boulger, Alex↗

Blackstart and Fault Ride-Through Capability of DFIG-Based Wind Turbines

Grid-forming wind turbines must be able to re-energize transmission branches, motor loads, unbalanced loads, and power electronics loads following a blackout. Further, they must ride through faults that can arise during restoration. To tackle these challenges, this paper sets forth a grid-forming control strategy for wind turbines using doubly-fed induction generators (DFIGs). In particular, a special set of feedforward control loops are engineered to mitigate the impacts of restoration transients as well as symmetrical and asymmetrical faults on the regulation of DFIG rotor currents and stator voltages. This paper also leverages two-axis anti-windup regulators to bound two-axis voltage and current commands within ratings. As a result, the controller performance is demonstrated via a high-fidelity simulation model of a notional wind-dominant grid.

17 WIND ENERGY↗

Streamlining of the RELAP5-3D Code

RELAP5-3D is widely used by the nuclear community to simulate general thermal hydraulic systems and has proven to be so versatile that the spectrum of transient two-phase problems that can be analyzed has increased substantially over time. To accommodate the many new types of problems that are analyzed by RELAP5-3D, both the physics and numerical methods of the code have been continuously improved. In the area of computational methods and mathematical techniques, many upgrades and improvements have been made decrease code run time and increase solution accuracy. These include vectorization, parallelization, use of improved equation solvers for thermal hydraulics and neutron kinetics, and incorporation of improved library utilities. In the area of applied nuclear engineering, expanded capabilities include boron and level tracking models, radiation/conduction enclosure model, feedwater heater and compressor components, fluids and corresponding correlations for modeling Generation IV reactor designs, and coupling to computational fluid dynamics solvers. Ongoing and proposed future developments include improvements to the two-phase pump model, conversion to FORTRAN 90, and coupling to more computer programs. This paper summarizes the general improvements made to RELAP5-3D, with an emphasis on streamlining the code infrastructure for improved maintenance and development. With all these past, present and planned developments, it is necessary to modify the code infrastructure to incorporate modifications in a consistent and maintainable manner. Modifying a complex code such as RELAP5-3D to incorporate new models, upgrade numerics, and optimize existing code becomes more difficult as the code grows larger. The difficulty of this as well as the chance of introducing errors is significantly reduced when the code is structured. To streamline the code into a structured program, a commercial restructuring tool, FOR_STRUCT, was applied to the RELAP5-3D source files. The methodology employed follows Dijkstra's structured programming paradigm, which is based on splitting programs into sub-sections, each with single points of entry and exit and in which control is passed downward through the structure with no unconditional branches to higher levels. GO TO commands are typically avoided, since they alter the flow and control of a program’s execution by allowing a jump from one place in the routine to another. The restructuring of RELAP5-3D subroutines is complicated by several issues. The first is use of code other than standard FORTRAN77. The second is restructuring limitations of FOR_STRUCT. The third is existence of pre-compiler directives and the complication of nested directives. Techniques were developed to overcome all these difficulties and more and these are reported. By implementing these developments, all subroutines of RELAP were restructured. Measures of code improvement relative to maintenance and development are presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The problem analysis of data processing performance in nuclear power plant computerized information and control system - 288

This paper is based on the data processing performance problems of operating command delay and system display not updating real-time for nuclear power plant computerized information and control system. The plant computerized information and control system is responsible for monitoring and controlling the plant operation, and it is a key part in the plant DCS system. Its data processing performance will affect the operation stability of nuclear power plant. The architecture, hardware configuration and data communication for plant computerized information and control system among the different levels in DCS are described. The main reasons affecting data processing performance in different signal channels are analyzed according to the plant load test results. The CPU load curves for real time server and central processing server are displayed, although the detailed cause for operating command delay and system display not updating realtime are not found, central processing server load is heavier than real time server which remind us to analyze the data processing of software resource scheduling deeply. So the resource distribution problem of software execution task is also analyzed according to CPU load test results. This paper provides the optimization analysis for data processing performance, and it is available and effective according to the latest test results. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Filtering adaptive output feedback control for multivariable nonlinear systems with mismatched uncertainties and unmodeled dynamics

This article synthesizes a filtering adaptive output feedback controller for multivariable nonlinear systems with mismatched uncertainties and unmodeled dynamics. The multivariable nonlinear systems under consideration have both matched and mismatched uncertainties, which satisfy the semiglobal Lipschitz condition. The unmodeled dynamics are bounded-input bounded-output stable. By adopting an estimation/cancellation strategy, a piecewise constant adaptive law drives the estimation error to zero at every time instant, which yields the adaptive parameters; a disturbance rejection control law is designed to compensate the nonlinear uncertainties within the bandwidth of low-pass filters. The matched uncertainties are cancelled directly by adopting their opposite in the control signal, while a dynamic inversion of the system is required to eliminate the effect of the mismatched uncertainties on the output. A feedforward control law is designed to track a given command. Since the virtual reference system defines the best performance that can be achieved by the closed-loop system, the uniform performance bounds are derived for the states and control signals via comparison. Both numerical and practical examples are provided to illustrate the effectiveness of the proposed filtering adaptive output feedback control architecture, comparisons with the model reference adaptive control demonstrates the superiority of the proposed control method.

filtering adaptive control, mismatched uncertainit↗

Nonlinear behavior in high-frequency aggregate control of thermostatically controlled loads

Coordinated control of electric loads can provide valuable grid services, such as frequency regulation. However, due to the nonlinear characteristics of such load ensembles, it is important to systematically analyze their behavior and establish a thorough understanding of undesirable phenomena that can potentially arise. In this paper, we analyze the frequency response of an aggregate control scheme, with the goal of exploring controller performance limits. We show that rapid switching commands can induce oscillations in the power output due to the inherent lockout mechanism of the underlying devices. Here, we demonstrate that highly detailed aggregate models are required to capture such phenomena. Such models enable deeper understanding of the control boundaries and therefore play an important role in avoiding the introduction of undesirable effects on the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Gemini Scout Control Software

The Gemini Scout Control Software consists of two Windows applications that allow the Gemini Scout vehicle to be controlled by an operator. The Embedded application runs on the vehicle's Gemini Scout Control Software onboard computer and controls the vehicle's various motors and sensors. This application reports the vehicle's status and receives vehicle commands overthe local-area-network. The Embedded applicationalso allows the user to control the vehicle using a USB game-pad connected directly to the vehicle. The Operator Control Unit (OCU) application runs on an external PC and communicates with the vehicle via an Ethernet connection. The OCU application sends commands to and receives data from the Embedded application running on the vehicle. The OCU application also communicates directly with the digital video encoders and radios in order to display video from the vehicle's cameras and the status of the radio link. The OCU application has a graphical user interface (GUI) that displays the vehicle's status and allows the user to change various vehicle settings. Finally, the OCU application receives input from a USB game-pad connected to the PC in order to control the vehicle's functions.

Clinton Hobart, Justin Garretson↗

Detailed Laboratory Evaluation of Electric Demand Load Shifting Potential of Controlled Heat Pump Water Heaters

The demand profile management of electric end uses is vital research for utilities and policymakers planning greenhouse gas emission reductions. In this study, detailed laboratory research was conducted on the load shifting potential of 4 grid-connected HPWHs and one electric resistance water heaters (ERWH). The testing applied different CTA-2045 shed and critical peak command designs under three water draw profiles. Highly-controlled laboratory experiments were conducted in Florida. One of the four HPWHs was a prototype incorporating the new CTA-2045-B protocol feature allowing ‘advanced’ load-up above tank setpoint. A three-hour morning (6 – 9 AM) and four-hour evening curtailment (4 – 8 PM) were defined as the shed or critical peak periods reflecting high-value control periods for utility coincident load for system-wide electric demand reductions. Tests were performed under baseline conditions (no load shift) and under varied load-shifting schemes, including load up and advanced load up, ahead of shed and critical peak commands. Data were collected from December 2020 – February 2022 in the laboratory and compared with field experiments in Florida and the Pacific Northwest. Grid-connected HPWHs were found to reduce peak demand by up to 0.47 kW compared to uncontrolled HPWH units, depending on time of day, control scheme, draw profile, and temperature cluster. The load up strategy demonstrated the ability of all units to utilize heat pump mode for extended periods ahead of peak events. Demand reductions for the HPWHs were much larger when compared with the ERWH— up to 1.64 kW with large hot water draws in winter.

Fenaughty, Karen↗

Towards a Standard Process Management Infrastructure for Workflows Using Python

Orchestrating the execution of ensembles of processes lies at the core of scientific workflow engines on large scale parallel platforms. This is usually handled using platform-specific command line tools, with limited process management control and potential strain on system resources. The PMIx standard provides a uniform interface to system resources. The low level C implementation of PMIx has hampered its use in workflow engines, leading to the development of Python binding that has yet to gain traction. In this paper, we present our work to harden the PMIx Python client, demonstrating its usability using a prototype Python driver to orchestrate the execution of an ensemble of processes. We present experimental results using the prototype on the Summit supercomputer at Oak Ridge National Laboratory. This work lays the foundation for wider adoption of PMIx for workflow engines, and encourages wider support of more PMIx functionality in vendor provided system software stacks.

Elwasif, Wael↗

Community Microgrid Planning Considering Building Thermal Dynamics

In this paper, the building thermal dynamic characteristics are introduced in the community microgrid (MG) planning model. The proposed planning model is formulated as a mixed integer linear programming (MILP) which seeks to determine the optimal deployment strategy for various distributed energy resources (DER). The objective is to minimize the annualized cost of community MG, including investment cost in DER, operation cost for dispatchable fuel-generators (DFG), energy storage system (ESS) degradation cost, energy purchasing and peak demand charge at PCC, customer discomfort cost due to the room temperature deviation and load curtailment cost. Given the slow thermal dynamic characteristics of buildings, the heating, ventilation and air-conditioning (HVAC) system in the proposed model is treated as a demand side management (DSM) component, whose dispatch commands are provided by the central MG controller. Numerical results based on a community MG comprising of 20 residential buildings demonstrate the effectiveness of the proposed planning model and the benefits of introducing the building thermal dynamic model.

Zhang, Xiaohu↗

Wave Tank Characterization Data

This data set was collected from a 16k gallon single paddle type wave tank after adjustments were made to the transfer function in the control software. The file names describe the commanded wave height and period which can then be compared with the actual measured height and period of the generated waves.

16 TIDAL AND WAVE POWER↗

Solar Hot Air Balloons for Terrestrial and Planetary Atmospheres

The first solar hot air balloon was constructed in the early 1970s (Besset, 2016). Over the following decades the Centre National d'Etudes Spatiales (CNES) developed the Montgolfiere Infrarouge (MIR) balloon, which flew on solar power during the day and infrared radiation from the Earth's surface at night (Fommerau and Rougeron, 2011). The balloons were capable of flying for over 60 days and apparently reached altitudes of 30 km at least once (Malaterre, 1993). Solar balloons were the subject of a Jet Propulsion Laboratory study that performed test flights on Earth (Jones and Wu 1999) and discussed their mission potential for Mars, Jupiter, and Venus (Jones and Heun, 1997). The solar balloons were deployed from the ground and dropped from hot air balloons; some were altitude controlled by means of a remotely-commanded air valve at the top of the envelope. More recently, solar balloons have been employed for infrasound studies in the lower stratosphere (see Table 1). The program began in 2015, when a prototype balloon reached an altitude of 22 kilometers before terminating just prior to float (Bowman et al., 2015). An infrasound sensor was successfully deployed on a solar balloon during the 2016 SISE/USIE experiment, in which an acoustic signal from a ground explosion was captured at a range of 330 km (Anderson et al. 2018; Young et al. 2018). This led to the launch of a 5-balloon infrasound network during the Heliotrope experiment (Bowman and Albert, 2018). The balloons were constructed by the researchers themselves at a materials of less than $50 per envelope.

14 SOLAR ENERGY↗

Final Scientific/Technical Report, Multi-Sensor Inspection and Robotic Systems for Dry Storage Casks

Once removed from service, fuel rod assemblies are cooled in a pool and then placed in dry storage until they can be transported to a repository for disposal. The extended duration that used nuclear fuel spends in dry storage makes it prudent to be able to nondestructively inspect the dry storage casks. The degradation mechanisms of most concern are chloride-induced stress corrosion cracking of the stainless steel canister that confines the spent fuel and distributed cracking of the concrete in the overpack structure. Multi-sensor inspection and robotic systems were researched, developed, built, and tested. One system operates completely outside the cask to inspect the concrete. The other system, known as the PRINSE system, for Proactive Robotic Inspection of Nuclear Storage Enclosures, enters the cask through an outlet vent and navigates around the outer surface of the stainless steel canister. The PRINSE system delivers sensors for: (i) real-time characterization of the canister surface in order to assess whether chlorides are present, (ii) detecting the presence of cracks using shear-horizontal ultrasonic guided waves, (iii) measuring the temperature of the canister surface, and (iv) a gamma radiation counter. The four sensing modalities are applicable to any cask containing a stainless steel canister, however the robotic delivery system is designed specifically for Holtec’s HI-STORM family of casks. Horizontal axis casks have exposed concrete surfaces. A fully contactless air-coupled scanning ultrasonic test platform and a frequency-wavenumber domain data analysis method are used for these concrete structures. Analysis, numerical simulation and experimental results demonstrate that distributed cracks in concrete can be detected and cracked regions localized within a scanned region of concrete. Vertical axis casks (like the HI-STORM family) have steel-clad concrete overpacks. In a separate effort, a semi-coupled test platform and a guided wave attenuation-based data analysis method are used for disbond detection. Analysis, numerical simulation and experimental results show that the bonding conditions of steel-concrete interfaces can be quantitatively characterized using the guided wave signal analysis scheme. The PRINSE system is designed for vertical axis dry storage casks, specifically the HI-STORM family. The double pulse laser-induced breakdown spectroscopy (LIBS) system takes advantage of an optical fiber to deliver intense light to the canister surface that enables surface composition characterization in-situ in real time. Chlorine concentrations as low as 10 mg/m2 were detected on stainless steel. Additionally, a simpler laser setup was created to detect sodium as a surrogate for chlorine, and sodium was detectable when the chlorine concentration was as low as 0.5 mg/m2. The electromagnetic acoustic transducers (EMATs) enable detection of stress corrosion cracks. The EMATs generate shear-horizontal waves that propagate around the canister and are reflected by cracks enabling 100% of the canister weld lines to be inspected. The EMAT-based crack detection system was tested at the Pacific Northwest National Laboratory on a canister containing blind defects and was shown to detect the crack sizes it was designed to detect. The PRINSE system is a novel marsupial robot. The command center and winch outside the cask control the delivery arm and train of cars that traverse the outside of the canister from the cask ventilation system. The sensors are housed in the cargo bays of three cars that comprise the train, which is lowered to the bottom of the canister by the winch. Encoders on the winch enable the sensors to be delivered to a prescribed location, e.g., for re-inspection of a problem area. The PRINSE system does not mar the canister surface, can be extracted manually in the case of a power failure, and is designed for an elevated temperature and gamma radiation environment, although not all components of the prototype are made from the final materials. The PRINSE system was tested on a full canister that was placed inside a HI-STORM cask at the Holtec Manufacturing Division. It was also demonstrated on a full-height mockup at Penn State to a live audience.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Robots, systems, and methods for hazard evaluation and visualization

A robot includes a hazard sensor, a locomotor, and a system controller. The robot senses a hazard intensity at a location of the robot, moves to a new location in response to the hazard intensity, and autonomously repeats the sensing and moving to determine multiple hazard levels at multiple locations. The robot may also include a communicator to communicate the multiple hazard levels to a remote controller. The remote controller includes a communicator for sending user commands to the robot and receiving the hazard levels from the robot. A graphical user interface displays an environment map of the environment proximate the robot and a scale for indicating a hazard intensity. A hazard indicator corresponds to a robot position in the environment map and graphically indicates the hazard intensity at the robot position relative to the scale.

47 OTHER INSTRUMENTATION↗

Simultaneously firing two cylinders of an even firing camless engine

A valve control system includes an engine speed control module that determines an engine speed and a desired engine stop position. A piston position module determines a desired stopping position of a first piston based on the desired engine stop position. A valve control module receives the desired stopping position, commands a set of valves to close at the desired stopping position if the engine speed is less than a predetermined shutdown threshold, and commands the set of valves to reduce the engine speed if the engine speed is greater than the predetermined shutdown threshold.

33 ADVANCED PROPULSION SYSTEMS↗

Web Based Beamline Control System (Bluesky Web) v0.1.0

Bluesky Web is a web based interface that provides beam line controls to the end user. It allows users to issue commands to various physical devices at a beam line end station like motors and cameras. It utilizes an open source Python library (Bluesky) as the controller. It uses Bluesky to also allow for running "plans" or a sequence of device operations that can be used when running an experiment. This program is different from other controls technologies because it is intended to be open source and can be accessed from a web browser, as opposed to other paid software that is run as a stand-alone application on a computer.

De Leon, Seij↗