Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “chip”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

An On-Chip Superconducting Kinetic Inductance Fourier Transform Spectrometer for Millimeter-Wave Astronomy

An on-chip FTS consists of two waveguides coupled to long superconducting transmission lines (STLs) (similar to 620 mm) using two coupling probes. The signal propagating on one of the STLs is phase-shifted with respect to the other line with a bias current that affects the nonlinear dependence of kinetic inductance, Lk(I)of the STL material. Here we describe the design and simulation of a superconducting on-chip FTS coupled to a dual polarization W-band (90-110 GHz) waveguide. These devices have applications in ground-based and space-based millimeter-wave spectral surveys.

Fourier transform spectrometer↗

Ultra-thin on-chip ALD LiPON capacitors for high frequency application

Multi-layer ceramic capacitors have been used for high frequency decoupling application due to a lower overall impedance leading to fast current response. However, high parasitic inductance limits the application of these capacitors in ultra-high frequency domain. Thus, Multlayer Ceramic Capacitors (MLCCs) are placed close to the IC to improve circuit efficiency and reduce inductance. With next generation applications, the demand for frequency range has further increased which not only requires enhanced capacitor material but improved manufacturing techniques to limit the inductive path. Here, we demonstrate ALD of two different polymorphs of ultra-thin film lithium phosphorus oxynitride (LiPON) as an inorganic solid state electrolyte (SSE) for on chip capacitors for decoupling application. Both the LiPON capacitors shows an electric double layer behavior with a capacitance of 15 μF/cm 2 and a low leakage current (<20 nA/cm 2 ) at 2V. The LiPON shows EDLC behavior up to 10 kHz and beyond, both the polymorphs show an electrostatic behavior with a high dielectric constant (14). Furthermore, this dual frequency behavior along with low parasitic inductance and on chip integration allows for operation in extended frequency ranges.

25 ENERGY STORAGE↗

Insight into industrial hemp ( Cannabis sativa L.) root exudation composition in a simulated soil environment: a rhizosphere-on-a-chip study

Microfluidic technologies provide a reduced complexity and soil-free environment to study plant-soil interactions at the microscale. Traditionally used for model plants such as Arabidopsis thaliana, this study represents the first application of a rhizosphere-on-a-chip (RhizoChip) to investigate root exudation in industrial hemp (Cannabis sativa L.), an agronomic crop with growing economic importance. By incorporating soil-like minerals (kaolinite, potassium feldspar, and biotite), the RhizoChip addresses limitations of previous research. Hemp seedlings grown in mineral-containing chips exhibited significant root growth, emphasizing the critical role of minerals in root development. Using untargeted metabolomics, 170 compounds were identified, including organic acids, amino acids, and secondary metabolites, with distinct profiles across conditions. Metabolic pathway analysis revealed activity in amino acid metabolism, the citric acid cycle, and secondary metabolite biosynthesis. In conclusion, this study highlights the RhizoChip's potential for long-term studies of root exudates in non-model crops and offers insights into rhizosphere processes with implications for sustainable agriculture.

59 BASIC BIOLOGICAL SCIENCES↗

Poly(dimethylsiloxane) microchip-based immunoassay with multiple reaction zones: Toward on-chip multiplex detection platform

In this work, a poly(dimethylsiloxane) (PDMS) microchip-based immuno-sensing platform with integrated pneumatic micro valves is described. The microchip was fabricated with multiple layer soft lithography technology. By controlling the activation status of corresponding valves, reagent flows in the microchannel network can be well manipulated so that immuno-reactions only take place at designated reaction zones (DRZs). Four DRZs are included in the prototype microchip. Since these DRZs are all isolated from each other by micro valves, cross contamination is prevented. Using the inner surface of the all-PDMS microchannel as immunoassay substrate, on-chip sandwich format solid phase immunoassay was performed to demonstrate the feasibility of this immuno-sensing platform. Mouse IgG and fluorescein isothiocyanate (FITC) were used as the model analyte and the signal reporter respectively. Only 10 ul sample is needed for the assay and low detection limit of 5 ng/ml (≈33 pM) was achieved though low-cost polyclonal antibodies were used in our experiment for feasibility study only. The encouraging results from mouse IgG immunoassay proved the feasibility of our microchip design. With slight modification of the assay protocol, the same chip design can be used for multi-target detection and can provide a simple, cost-effective and integrated microchip solution for multiplex immunoassay applications.

60 APPLIED LIFE SCIENCES↗

On-chip sensing of hotspots in superconducting terahertz emitters

Intrinsic Josephson junctions in high-temperature superconductor Bi 2 Sr 2 CaCu 2 O 8+δ (BSCCO) are known for their capability to emit high-power terahertz photons with widely tunable frequencies. Hotspots, as inhomogeneous temperature distributions across the junctions, are believed to play a critical role in synchronizing the gauge-invariant phase difference among the junctions, so as to achieve coherent strong emission. In this paper, we demonstrate an on-chip in situ sensing technique that can characterize hotspot distributions on BSCCO. This is achieved by fabricating a series of micro-nanosized "sensor" junctions on top of an "emitter" junction and measuring the critical current on the sensors versus the bias current applied to the emitter. Furthermore, this fully electronic on-chip design can enable efficient close-loop control of hotspots in BSCCO junctions and significantly enhance the functionality of superconducting terahertz emitters.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

On-Chip Tuning of Superconductivity in Fullerides via Current-Driven Rb + Intercalation

An in-operando electro-intercalation method for the on-chip synthesis of alkali-metal-intercalated materials and their Raman spectroscopic and transport characterization in ultrahigh vacuum (UHV) is developed. We apply this method to synthesize fulleride superconductors via Rb + intercalation into a C 60 film. During the intercalation, we monitor the stoichiometry via UHV-Raman spectroscopy and probe superconductivity via transport measurements. An increase of the superconducting transition temperature from 7.0 K to 14.5 K is observed when the stoichiometry is tuned from Rb 2.7 C 60 to Rb 3 C 60 . In our experiment, an ionic Rb+ flux into the host material is induced by an applied electronic current via a Butler–Volmer-type mechanism. Electro-intercalation captivates through improved stoichiometric precision, the ability to smoothly vary stoichiometry via duration of current application, and the absence of a lower limit of the volume of the host material. It represents a powerful concept for the on-chip synthesis of intercalated materials, battery research, and beyond.

Raman↗

Surface-Enhanced Infrared Absorption: Pushing the Frontier for On-Chip Gas Sensing

Surface-enhanced infrared absorption (SEIRA) is capable of identifying molecular fingerprints by resonant detection of infrared vibrational modes through the coupling with plasmonic modes of metallic nanostructures. However, SEIRA for on-chip gas sensing is still not very successful due to the intrinsically weak light-matter interaction between photons and gas molecules and the technical challenges in accumulating sufficient gas species in the vicinity of the spatially localized enhanced electric field, namely, the “hot-spots”, generated through plasmonics. In this paper, we present a suspended silicon nitride (Si 3 N 4 ) nanomembrane device by integrating plasmonic nanopatch gold antennas with metal–organic framework (MOF), which can largely adsorb carbon dioxide (CO 2 ) through its nanoporous structure. Unlike conventional SEIRA sensing relying on highly localized hot-spots of plasmonic nanoantennas or nanoparticles, the device reported in this article engineered the coupled surface plasmon polaritons in the metal–Si 3 N 4 and metal–MOF interfaces to achieve strong optical field enhancement across the entire MOF film. Lastly, we successfully demonstrated on-chip gas sensing of CO 2 with more than 1800× enhancement factors by combining the concentration effect from the 2.7 μm MOF thin film and the optical field enhancement of the plasmonic nanopatch antennas.

47 OTHER INSTRUMENTATION↗

Casimir Forces On A Silicon Micromechanical Chip

Quantum fluctuations give rise to van der Waals and Casimir forces that dominate the interaction between electrically neutral objects at sub-micron separations. Under the trend of miniaturization, such quantum electrodynamical effects are expected to play an important role in micro- and nano-mechanical devices. Nevertheless, so far the Casimir force has been experimentally observed only in situations involving an external object manually positioned close to a micromechanical element on a silicon chip. Here, we demonstrate the Casimir effect between two silicon components on the same substrate. In addition to providing an integrated and compact platform for Casimir force measurements, this scheme also opens the possibility of tailoring the Casimir force using lithographically defined components of non-conventional shapes on a single micromechanical chip.

Zou, J.↗

Coherent terahertz radiation with 2.8-octave tunability through chip-scale photomixed microresonator optical parametric oscillation

High-spectral-purity frequency-agile room-temperature sources in the terahertz spectrum are foundational elements for imaging, sensing, metrology, and communications. Here we present a chip-scale optical parametric oscillator based on an integrated nonlinear microresonator that provides broadly tunable single-frequency and multi-frequency oscillators in the terahertz regime. Through optical-to-terahertz down-conversion using a plasmonic nanoantenna array, coherent terahertz radiation spanning 2.8-octaves is achieved from 330 GHz to 2.3 THz, with ≈20 GHz cavity-mode-limited frequency tuning step and ≈10 MHz intracavity-mode continuous frequency tuning range at each step. By controlling the microresonator intracavity power and pump-resonance detuning, tunable multi-frequency terahertz oscillators are also realized. Furthermore, by stabilizing the microresonator pump power and wavelength, sub-100 Hz linewidth of the terahertz radiation with 10 –15 residual frequency instability is demonstrated. The room-temperature generation of both single-frequency, frequency-agile terahertz radiation and multi-frequency terahertz oscillators in the chip-scale platform offers unique capabilities in metrology, sensing, imaging and communications.

42 ENGINEERING↗

On-chip parallel processing of quantum frequency comb

Abstract The frequency degree of freedom of optical photons has been recently explored for efficient quantum information processing. Significant reduction in hardware resources and enhancement of quantum functions can be expected by leveraging the large number of frequency modes. Here, we develope an integrated photonic platform for the generation and parallel processing of quantum frequency combs (QFCs). Cavity-enhanced parametric down-conversion with Sagnac configuration is implemented to generate QFCs with identical spectral distributions. On-chip quantum interference of different frequency modes is simultaneously realized with the same photonic circuit. High interference visibility is maintained across all frequency modes with the identical circuit setting. This enables the on-chip reconfiguration of QFCs. By deterministically separating QFCs without spectral filtering, we further demonstrate high-dimensional Hong-Ou-Mandel effect. Our work provides the critical step for the efficient implementation of quantum information processing with integrated photonics using the frequency degree of freedom.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Position-sensitive spectral splitting with a plasmonic nanowire on silicon chip

On-chip nanophotonics serves as the foundation for the new generation of information technology, but it is challenged by the diffraction limit of light. With the capabilities of confining light into (deep) subwavelength volumes, plasmonics makes it possible to dramatically miniaturize optical devices so as to integrate them into silicon chips. Here we demonstrate that by cascading nano-corrugation gratings with different periodicities on silver nanowires atop silicon, different colors can be spatially separated and chronologically released at different grating junctions. The released light frequency depends on the grating arrangement and corrugation periodicities. Hence the nanowire acts as a spectral splitter for sorting/ demultiplexing photons at different nano-scale positions with a ten-femtosecond-level interval. Such nanowires can be constructed further into compact 2D networks or circuits. We believe that this study provides a new and promising approach for realizing spatiotemporal-sensitive spectral splitting and optical signal processing on nanoscales, and for general integration of nanophotonics with microelectronics.

NANOPHOTONICS AND PLASMONICS↗

Surface enhanced Raman spectroscopy for microfluidic pillar arrayed separation chips

Numerous studies have addressed the challenges of implementing miniaturized microfluidic platforms for chemical and biological separation applications. However, the integration of real time detection schemes capable of providing valuable sample information under continuous, ultra low volume flow regimes has not fully been addressed. In this report we present a chip based chromatography system comprising of a pillar array separation column followed by a reagent channel for passive mixing of a silver colloidal solution into the eluent stream to enable surface enhanced Raman spectroscopy (SERS) detection. Our design is the first integrated chip based microfluidic device to combine pressure driven separation capability with real time SERS detection. With this approach we demonstrate the ability to collect distinctive SERS spectra with or without complete resolution of chromatographic bands. Computational fluidic dynamic (CFD) simulations are used to model the diffusive mixing behavior and velocity profiles of the two confluent streams in the microfluidic channels. We evaluate the SERS spectral band intensity and chromatographic efficiency of model analytes with respect to kinetic factors as well as signal acquisition rates. Additionally, we discuss the use of a pluronic modified silver colloidal solution as a means of eliminating contamination generally caused by nanoparticle adhesion to channel surfaces.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Simultaneous electrical recording of cardiac electrophysiology and contraction on chip

Prevailing commercialized cardiac platforms for in vitro drug development utilize planar microelectrode arrays to map action potentials, or impedance sensing to record contraction in real time, but cannot record both functions on the same chip with high spatial resolution. We report a novel cardiac platform that can record cardiac tissue adhesion, electrophysiology, and contractility on the same chip. The platform integrates two independent yet interpenetrating sensor arrays: a microelectrode array for field potential readouts and an interdigitated electrode array for impedance readouts. Together, these arrays provide real-time, non-invasive data acquisition of both cardiac electrophysiology and contractility under physiological conditions and under drug stimuli. Furthermore, we cultured human induced pluripotent stem cell-derived cardiomyocytes as a model system, and used to validate the platform with an excitation–contraction decoupling chemical. Preliminary data using the platform to investigate the effect of the drug norepinephrine are combined with computational efforts. Finally, this platform provides a quantitative and predictive assay system that can potentially be used for comprehensive assessment of cardiac toxicity earlier in the drug discovery process.

59 BASIC BIOLOGICAL SCIENCES↗

ID-SERS Based Reference Method for Quantification of Large Biomolecules on a Single Chip

Accuracy and precision of quantitative SERS results have been significantly increased by applying a method based on the so-called isotope-dilution (ID) principle. In this ID-SERS approach, an isotopically labeled analogue of the target molecule (isotopologue) is spiked to the sample at a known concentration. Due to the slight difference in their molar masses, some Raman bands of the heavier isotopologue are red-shifted with respect to the same signals resulting from the unlabelled compound. As a result, spectra evaluation is reduced to the determination of intensity ratios rather than absolute intensities, and the unknown quantity of the analyte can be calculated from the known quantity of the standard. This procedure is of particular interest in the development of highly accurate reference procedures for metrology in chemistry. Because the sample is spiked prior to any further treatment, potential loss of material or matrix effects would equally affect both isotopologues, without influencing the final result. The method has been successfully applied for quantifying small diagnostic marker molecules like creatinine at their relevant serum concentration levels using silver colloids as SERS substrates. Now, the ID-SERS approach has been realized as a 'one-chip' approach using 'Bio-chips' made of intrinsically grown spherical silver nanoparticles with gaps less than 10 nm in between (Fig. 1). In addition, the scope of the method has been extended to larger biomolecules like peptides which will be shown using the example of the human growth-hormone (hGH) peptide T12 at physiologically relevant serum concentration levels (Fig. 2). Further developments towards the quantification of full proteins will also be reported.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Numerical Approach and Comparison of Cutting Forces and Chip Morphology in Orthogonal Cutting of Light Alloys

This paper deals with the simulation of UNS A92024 aluminium alloy cutting processes. In particular, 2D and 3D Finite Element Method (FEM) simulations were carried out in order to estimate cutting forces and chip morphology during turning operations. The material is modelled with two different set of parameters for the Johnson--Cook's (J-C) constitutive equation and a failure Cockroft and Latham's model exploited considers damage. The comparison between the predicted chip morphology and principal cutting forces at varying of J-C parameters and cutting regimes with those experimentally found are presented and discussed. The paper shows the importance of damage criterion in the cutting forces, during the simulation, especially in 3D.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High frequency alternating current chip nano calorimeter with laser heating

Heat capacity spectroscopy at frequencies up to 100 kHz is commonly performed by thermal effusivity measurements applying the 3ω-technique. Here we show that AC-calorimetry using a thin film chip sensor allows for the measurement of frequency dependent heat capacity in the thin film limit up to about 1 MHz. Using films thinner than the thermal length of the thermal wave (∼1 μm) at such frequencies is advantageous because it provides heat capacity alone and not in combination with other quantities like thermal conductivity, at least on a qualitative basis. The used calorimetric sensor and the sample are each less than 1 μm thick. For high frequency AC-calorimetry, high cooling rates at very small temperature differences are required. This is realized by minimizing the heated spot to the size of the on chip thermocouple (3 × 6 μm{sup 2}). A modulated laser beam shaped and positioned by a glass fiber is used as the heat source. The device was used to measure the complex heat capacity in the vicinity of the dynamic glass transition (structural relaxation) of poly(methyl methacrylate). Combining different calorimeters finally provides data between 10{sup −3} Hz and 10{sup 6} Hz. In this frequency range the dynamic glass transition shifts about 120 K.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a chip-based ingroove microplasma source: Design, characterization, and diagnostics

A chip-based ingroove microplasma source was designed for molecular emission spectrometry by using a space-confined direct current duct in air. The voltage-current characteristics of different size generators, emission spectroscopy of argon were discussed, respectively. It is found that the emission intensity of excited Ar and N{sub 2} approaches its maximum near the cathode, while OH and O peaks most likely appear close to the anode. The electron density, electronic excitation temperature, rotational temperature, and vibrational temperature of the argon plasma were also calculated. More importantly, the chip-based ingroove microplasma shows much better stability compared with its counterparts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absorber and gain chip optimization to improve performance from a passively modelocked electrically pumped vertical external cavity surface emitting laser

We present an electrically pumped vertical-external-cavity surface-emitting laser (EP-VECSEL) modelocked with a semiconductor saturable absorber mirror (SESAM) with significantly improved performance. In different cavity configurations, we present the shortest pulses (2.5 ps), highest average output power (53.2 mW), highest repetition rate (18.2 GHz), and highest peak power (4.7 W) to date. The simple and low-cost concept of EP-VECSELs is very attractive for mass-market applications such as optical communication and clocking. The improvements result from an optimized gain chip from Philips Technologie GmbH and a SESAM, specifically designed for EP-VECSELs. For the gain chip, we found a better trade-off between electrical and optical losses with an optimized doping scheme in the substrate to increase the average output power. Furthermore, the device's bottom contact diameter (60 μm) is smaller than the oxide aperture diameter (100 μm), which favors electro-optical conversion into a TEM{sub 00} mode. Compared to optically pumped VECSELs we have to increase the field enhancement in the active region of an EP-VECSEL which requires a SESAM with lower saturation fluence and higher modulation depth for modelocking. We therefore used a resonant quantum well SESAM with a 3.5-pair dielectric top-coating (SiN{sub x} and SiO{sub 2}) to enhance the field in the absorber at the lasing wavelength of 980 nm. The absorption bandedge at room temperature is detuned (965 nm) compared to the resonance (980 nm), which enables temperature-tuning of the modulation depth and saturation fluence from approximately 2.5% up to 15% and from 20 μJ/cm{sup 2} to 1.1 μJ/cm{sup 2}, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗