Energy Demands and Efficiency Strategies in Data Center Buildings

Information technology (IT) is becoming increasingly pervasive throughout society as more data is digitally processed, stored, and transferred. The infrastructure that supports IT activity is growing accordingly, and data center energy demands haveincreased by nearly a factor of four over the past decade. Data centers house IT equipment and require significantly more energy to operate per unit floor area thanconventional buildings. The economic and environmental ramifications of continued data center growth motivate the need to explore energy-efficient methods to operate these buildings. A substantial portion of data center energy use is dedicated to removing the heat that is generated by the IT equipment. Using economizers to introduce large airflow rates of outside air during favorable weather could substantially reduce the energy consumption of data center cooling. Cooling buildings with economizers is an established energy saving measure, but in data centers this strategy is not widely used, partly owing to concerns that the large airflow rates would lead to increased indoor levels of airborne particles, which could damage IT equipment. The environmental conditions typical of data centers and the associated potential for equipment failure, however, are not well characterized. This barrier to economizer implementation illustrates the general relationship between energy use and indoor air quality in building design and operation. This dissertation investigates how building design and operation influence energy use and indoor air quality in data centers and provides strategies to improve both design goals simultaneously.As an initial step toward understanding data center air quality, measurements of particle concentrations were made at multiple operating northern California data centers. Ratios of measured particle concentrations in conventional data centers to the corresponding outside concentrations were significantly lower than those reported in the literature for office or residential buildings. Estimates using a material-balance model match well with empirical results, indicating that the dominant particle sources and losses -- ventilation and filtration -- have been characterized. Measurements taken at a data center using economizers show nearly an order of magnitude increase in particle concentration during economizer activity. However, even with the increase, themeasured particle concentrations are still below concentration limits recommended in most industry standards. The research proceeds by exploring the feasibility of using economizers in data centers while simultaneously controlling particle concentrations with high-quality air filtration. Physical and chemical properties of indoor and outdoor particles were analyzed at a data center using economizers and varying levels of air filtration efficiency. Results show that when improved filtration is used in combination with an economizer, the indoor/outdoor concentration ratios for most measured particle types were similar to the measurements when using conventional filtration without economizers. An energy analysis of the data center reveals that, even during the summer months, chiller savings from economizer use greatly outweigh the increase in fan power associated with improved filtration. These findings indicate that economizer use combined with improved filtration couldsignificantly reduce data center energy demand while providing a level of protection from particles of outdoor origin similar to that observed with conventional design. The emphasis of the dissertation then shifts to evaluate the energy benefits of economizer use in data centers under different design strategies. Economizer use with high ventilation rates is compared against an alternative, water-side economizer design that does not affect indoor particle concentrations. Building energy models are employed to estimate energy savings of both economizer designs for data centers in

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New helium recapture and reliquefier system for Dynamic Nuclear Polarization at UNH.

A new helium recapture and reliquefaction system, consisting of a gas bag, recapture manifold, cooling chiller, cryogenic purifier and, a gas storage cylinder banks, has been installed in the dynamic nuclear polarized target lab at the University of New Hampshire. This new system has the capability to improve the efficiency of our capacity to do target polarization runs by recycling our cryogenic helium which would otherwise be lost during polarization operations. Our helium liquefier is rated upto 40 L/Day under normal full-capacity operations, and is rated for a capacity of 500 liquid liters of helium. I explain the initial installation process followed by a discussion of the challenges with installation, including issues of impurities which appeared during the initial operation of the system. Then I discuss how we overcame these difficulties. Finally, I discuss the function of the system during normal operation and the present situation of the helium recapture and reliquefaction processing in the UNH Lab.

Lama, Chhetra [Univ. of New Hampshire, Durham, NH ↗

Experimental Comparison of Hydrogen Refueling with Directly Pressurized vs. Cascade Method

This paper presents a comparative analysis of two hydrogen station configurations during the refueling process: the conventional “directly pressurized refueling process” and the innovative “cascade refueling process.” The objective of the cascade process is to refuel vehicles without the need for booster compressors. The experiments were conducted at the Hydrogen Research and Fueling Facility located at California State University, Los Angeles. In the cascade refueling process, the facility buffer tanks were utilized as high-pressure storage, enabling the refueling operation. Three different scenarios were tested: one involving the cascade refueling process and two involving compressor-driven refueling processes. On average, each refueling event delivered 1.6 kg of hydrogen. Although the cascade refueling process using the high-pressure buffer tanks did not achieve the pressure target, it resulted in a notable improvement in the nozzle outlet temperature trend, reducing it by approximately 8 °C. Moreover, the overall hydrogen chiller load for the two directly pressurized refuelings was 66 Wh/kg and 62 Wh/kg, respectively, whereas the cascading process only required 55 Wh/kg. This represents a 20% and 12% reduction in energy consumption compared to the scenarios involving booster compressors during fueling. The observed refueling range of 150–350 bar showed that the cascade process consistently required 12–20% less energy for hydrogen chilling. Additionally, the nozzle outlet temperature demonstrated an approximate 8 °C improvement within this pressure range. These findings indicate that further improvements can be expected in the high-pressure region, specifically above 350 bar. This research suggests the potential for significant improvements in the high-pressure range, emphasizing the viability of the cascade refueling process as a promising alternative to the direct compression approach.

08 HYDROGEN↗

Towards Energy-Positive Buildings through a Quality-Matched Energy Flow Strategy

Current strategies for net-zero buildings favor envelopes with minimized aperture ratios and limiting of solar gains through reduced glazing transmittance and emissivity. This load-reduction approach precludes strategies that maximize on-site collection of solar energy, which could increase opportunities for net-zero electricity projects. To better leverage solar resources, a whole-building strategy is proposed, referred to as “Quality-Matched Energy Flows” (or Q-MEF): capturing, transforming, buffering, and transferring irradiance on a building’s envelope—and energy derived from it—into distributed end-uses. A mid-scale commercial building was modeled in three climates with a novel Building-Integrated, Transparent, Concentrating Photovoltaic and Thermal fenestration technology (BITCoPT), thermal storage and circulation at three temperature ranges, adsorption chillers, and auxiliary heat pumps. BITCoPT generated electricity and collected thermal energy at high efficiencies while transmitting diffuse light and mitigating excess gains and illuminance. The balance of systems satisfied cooling and heating demands. Relative to baselines with similar glazing ratios, net electricity use decreased 71% in a continental climate and 100% or more in hot-arid and subtropical-moderate climates. Total EUI decreased 35%, 83%, and 52%, and peak purchased electrical demands decreased up to 6%, 32%, and 20%, respectively (with no provisions for on-site electrical storage). Decreases in utility services costs were also noted. These results suggest that with further development of electrification the Q-MEF strategy could contribute to energy-positive behavior for projects with similar typology and climate profiles.

54 ENVIRONMENTAL SCIENCES↗

A Probabilistic Approach to Load Modeling for Central HVAC Systems in Large Commercial Buildings for Retrofit Decisions Under Uncertainty

Retrofitting central HVAC systems in large commercial buildings with advanced technologies like heat recovery chillers (HRCs) offers a significant opportunity to enhance energy efficiency. However, analyzing these retrofits is challenging with traditional whole-building simulation tools, which require intensive calibration and struggle to model innovative system configurations and controls. To overcome these limitations, this study proposes a load profilebased retrofit analysis framework that provides better decisions under uncertainty. The main focus of this paper is the development of a probabilistic load profile model that can be used in the framework by using exploratory data analysis (EDA) of measured building data to properly quantify its inherent variability. A non-parametric Gaussian Process (GP) model was employed to capture the time- and weather-dependent characteristics of the heating load while explicitly modeling its uncertainty. The model's effectiveness is demonstrated through strong predictive performance on unseen data and physically interpretable insights into load behavior. This data-driven, probabilistic load profile serves as a robust and flexible input for subsequent system simulations, enabling a more confident and statistically sound analysis of retrofit potential.

Ham, S W↗

Project Phase 1 Report: Reducing Data Center Peak Cooling Demand and Energy Costs With Cold Underground Thermal Energy Storage (Cold UTES)

Cold Underground Thermal Energy Storage (Cold UTES) is an ultra-long duration grid energy storage technology. With Cold-UTES, low-cost grid power is converted to cold thermal energy and stored in the native subsurface rock at the point of use. Cold UTES is one approach within the general category of engineered geothermal systems. Cold UTES for peak-hour cooling of data centers (DCs) was studied for deployment in Maricopa County, Arizona and Loudoun County, Virgina using thermal storage capacities from 4 GWh-th to over 1,000 GWh-th (>1 Terawatt-hour). The two sites have different power and transmission systems, available grid energy resources, daily and seasonal load profiles, weather conditions, and grid regulatory requirements. The study results indicate high value for both locations and because of this, likely indicates value across most of the US and the world. The basis of the study was a 1,000 MW-e hourly electric use of DC computing and auxiliary loads, which was modeled as 1 GW-th of thermal load to a dry cooled heat rejection system - i.e. a cooling system that does not consume water. The electric power required for cooling the DC varies as the air temperature changes. In cold weather only the dry-coolers are used, with an electrical load for cooling load as low as 10 MW-e. In hot summer hours, chillers and dry- coolers are required, which raises the electrical load for cooling load to as much as 300 MW-e. The continuous and peak cooling electrical loads result in a grid interconnection requirement of no less than 1,300 MW-e. From both a grid and thermal design modeling perspective the 1.3 GW-e could either be a single facility or result from the total load at multiple sites.

15 GEOTHERMAL ENERGY↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Thermoelectrically cooled cloud physics expansion chamber

The design and fabrication of a thermoelectric chiller for use in chilling a liquid reservoir is described. Acceptance test results establish the accuracy of the thermal model and predict the unit performance under various conditions required by the overall spacelab program.

Buist, R. J.↗

Description and status of NASA-LeRC/DOE photovoltaic applications systems

Designed, fabricated and installed were 16 geographically dispersed photovoltaic systems. These systems are powering a refrigerator, highway warning sign, forest lookout towers, remote weather stations, a water chiller at a visitor center, and insect survey traps. Each of these systems is described in terms of load requirements, solar array and battery size, and instrumentation and controls. Operational experience is described and present status is given for each system. The P/V power systems have proven to be highly reliable with almost no problems with modules and very few problems overall.

Ratajczak, A. F.↗

Solar heating, cooling, and hot water systems installed at Richland, Washington

The project described is part of the U. S. Department of Energy's solar demonstration program, and became operational in April 1978. The solar system uses 6,000 square feet of flat-plate liquid collectors in a closed loop to deliver solar energy through a liquid-liquid heat exchanger to the building heat-pump duct work or 9,000-gallon thermal energy storage tank. A 25-ton Arkla solar-driven absorption chiller provides the cooling, in conjunction with a 2,000 gallon chilled water storage tank and reflective ponds on three sides of the building surplus heat. A near-by building is essentially identical except for having conventional heat-pump heating and cooling, and can serve as an experimental control. An on-going public relations program was provided from the beginning of the program, and resulted in numerous visitors and tour groups.

Source record↗

NASA Lewis Research Center photovoltaic application experiments

The NASA Lewis Research Center has installed 16 geographically dispersed terrestrial photovoltaic systems as part of the DOE National Photovoltaic Program. Four additional experiments are in progress. Currently, operating systems are powering refrigerators, a highway warning sign, forest lookout towers, remote weather stations, a water chiller and insect survey traps. Experiments in progress include the world's first village power system, an air pollution monitor and seismic sensors. Under a separate activity, funded by the U.S. Agency for International Development, a PV-powered water pump and grain grinder is being prepared for an African village. System descriptions and status are included in this report.

Ratajczak, A.↗

Fuel cell on-site integrated energy system parametric analysis of a residential complex

The use of phosphoric acid fuel cell powerplant to provide all the electricity required by an 81-unit garden apartment complex is studied. Byproduct heat is recovered and provides some of the heat required by the complex. The onsite integrated energy system contains energy conversion equipment including combinations of compression and absorption chillers, heat pumps, electric resistance heaters, and thermal storage. The annual fuel requirement for several onsite integrated energy systems as well as the fuel cell breakeven cost for one specific system were calculated. It is found that electrical efficiency cannot be traded off against thermal efficiency without paying a penalty in system efficiency.

Simons, S. N.↗

Description and status of NASA-LeRC/DOE photovoltaic applications systems experiments

In its role of supporting the DOE Photovoltaic Program, the NASA-Lewis Research Center has designed, fabricated and installed 16 geographically dispersed photovoltaic systems. These systems are powering a refrigerator, highway warning sign, forest lookout towers, remote weather stations, a water chiller at a visitor center, and insect survey traps. Each of these systems is described in terms of load requirements, solar array and battery size, and instrumentation and controls. Operational experience is described and present status is given for each system. The P/V power systems have proven to be highly reliable with almost no problems with modules and very few problems overall

Ratajczak, A. F.↗

A study of poultry processing plant noise characteristics and potential noise control techniques

The noise environment in a typical poultry processing plant was characterized by developing noise contours for two representative plants: Central Soya of Athens, Inc., Athens, Georgia, and Tip Top Poultry, Inc., Marietta, Georgia. Contour information was restricted to the evisceration are of both plants because nearly 60 percent of all process employees are stationed in this area during a normal work shift. Both plant evisceration areas were composed of tile walls, sheet metal ceilings, and concrete floors. Processing was performed in an assembly-line fashion in which the birds travel through the area on overhead shackles while personnel remain at fixed stations. Processing machinery was present throughout the area. In general, the poultry processing noise problem is the result of loud sources and reflective surfaces. Within the evisceration area, it can be concluded that only a few major sources (lung guns, a chiller component, and hock cutters) are responsible for essentially all direct and reverberant sound pressure levels currently observed during normal operations. Consequently, any effort to reduce the noise problem must first address the sound power output of these sources and/or the absorptive qualitities of the room.

Wyvill, J. C.↗

Solar-Heated and Cooled Office Building--Columbus, Ohio

Final report documents solar-energy system installed in office building to provide space heating, space cooling and domestic hot water. Collectors mounted on roof track Sun and concentrate rays on fluid-circulating tubes. Collected energy is distributed to hot-water-fired absorption chiller and space-heating and domestic-hot-water preheating systems.

Source record↗

Solar heating and cooling system installed at Columbus, Ohio

The Solar Energy System was installed as a part of a new construction of a college building. The building will house classrooms and laboratories, administrative offices and three lecture halls. The Solar Energy System consists of 4,096 square feet (128 panels) Owens/Illinois Evacuated Glass Tube Collector Subsystem, and a 5,000 gallon steel tank below ground storage system. Hot water is circulated between the collectors and storage tank, passing through a water/lithium bromide absorption chiller to cool the building.

Source record↗

Solar heating, cooling, and domestic hot water system installed at Kaw Valley State Bank and Trust Company, Topeka, Kansas

The building has approximately 5600 square feet of conditioned space. Solar energy was used for space heating, space cooling, and preheating domestic hot water (DHW). The solar energy system had an array of evacuated tube-type collectors with an area of 1068 square feet. A 50/50 solution of ethylene glycol and water was the transfer medium that delivered solar energy to a tube-in-shell heat exchanger that in turn delivered solar heated water to a 1100 gallon pressurized hot water storage tank. When solar energy was insufficient to satisfy the space heating and/or cooling demand, a natural gas-fired boiler provided auxiliary energy to the fan coil loops and/or the absorption chillers. Extracts from the site files, specification references, drawings, and installation, operation and maintenance instructions are presented.

Source record↗

Solar heating, cooling and domestic hot water system installed at Columbia Gas System Service Corporation, Columbus, Ohio

The solar energy system installed in the building has 2,978 sq ft of single axis tracking, concentrating collectors and provides solar energy for space heating, space cooling and domestic hot water. A 1,200,000 Btu/hour water tube gas boiler provides hot water for space heating. Space cooling is provided by a 100 ton hot water fired absorption chiller. Domestic hot water heating is provided by a 50 gallon natural gas domestic storage water heater. Extracts from the site files, specification references, drawings, installation, operation and maintenance instructions are included.

Source record↗