Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “casing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Survey of Use Cases and Scenarios on the Open Energy Data Initiative Solar Systems Integration (OEDI SI) Platform

The Open Energy Data Initiative Solar Systems Integration (OEDI SI) Data and Modeling Platform offers a comprehensive set of use cases tailored for power systems analysis. Each use case is centered around a specific power system analysis problem, supported by composite input data and reference algorithms. These composite input datasets are meticulously assembled using OEDI SI's data preprocessing tools, which integrate raw data from various sources. The primary objectives of the OEDI SI Platform include facilitating access to composite input data through widely accepted input/output formats and verified results. This accessibility enables power system network researchers and developers to validate their algorithms and showcase their applications' capabilities to the broader community. Moreover, the platform strives to promote reproducible, robust, replicable, and generalizable solar systems integration research.

14 SOLAR ENERGY↗

2023 Business Case Study: Hydrothermal Liquefaction of Algal Bloom Biomass

A business case study was developed for the fiscal year (FY) 2023 to explore the technical and economic feasibility of converting lake-harvested algal bloom biomass (ABB) into biofuel via hydrothermal liquefaction (HTL). The case study includes reporting on the experimental demonstration of converting the algal feedstock to HTL biocrude. Using the experimental data, a preliminary techno-economic assessment (TEA) of a commercial-scale facility was completed to determine the economic feasibility of the process.

09 BIOMASS FUELS↗

2024 Case Study: Hydrothermal Liquefaction of Biomass Sources at a Wastewater Treatment Facility

A case study was developed for the fiscal year 2024 to examine the potential of wastewater-grown microalgae as a feedstock for hydrothermal liquefaction (HTL) to produce fuels and other products. In this year’s case study, scenarios are investigated in which the algae cultivation process is placed at different points within the water resource recovery facility (WRRF). Additionally, the supply of biomass for HTL is boosted by blending with wastewater solids collected at different locations within the WRRF.

09 BIOMASS FUELS↗

Sensitivity Analysis Comparisons on Geologic Case Studies: An International Collaboration, Volume 2

Over the past six years, an informal working group has developed to investigate existing sensitivity analysis methods, examine new methods, and identify best practices. The focus is on the use of sensitivity analysis in case studies involving geologic disposal of spent nuclear fuel or nuclear waste. Three additional case studies are presented in this Volume 2 report, including more nonlinear behavior, outputs which exhibit bifurcation, regime changes, and nested sampling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hybrid Power Plants for Energy Resilience: A Case Study

As renewable energy technologies are increasingly adopted, they pose an opportunity to improve the sustainability and resilience of distributed grids, especially when their design and operation is coordinated as a hybrid power plant. When included in hybrid power plants, distributed wind turbines in particular have the potential to enhance the resilience of distributed grids in areas with good wind resource, due to their ability to provide more consistent generation and ancillary services as compared to photo-voltaic (PV) solar panels. Despite this benefit, U.S. distributed wind adoption is lower than other comparable renewable energy technologies. In this study, we seek to demonstrate how hybrid power plants that include distributed wind turbines can contribute to distribution grid resilience by meeting loads (especially critical loads) more consistently, increasing reserve capacity, and providing value to customers during outages. To demonstrate these contributions, we integrate three separate frameworks and apply them to a case study in a rural electric cooperative in Iowa. Through this case study, we simulate and compare hybrid power plant design and operation during two hazard events: a tornado that causes a 48-hour distribution outage and a winter weather event that causes a 6-hour generation outage. The inclusion of a hybrid power plant that leverages 1) increased battery duration and 2) advanced forecasting and dispatch strategies that reserve capacity leading up to a hazard event best reduce lost loads as well as diesel consumption that would otherwise be used to meet those loads during short- and long-duration hazard events. Depending on the hybrid power plant capacity and operation, we find that the outage mitigation value of a hybrid power plant (measured in value to customers to avoid an outage and avoided lost revenues for the utility) is significant in both hazard events; adding wind, solar, and battery assets to the existing system adds about $50-$100M in avoided lost load and at least $4-$8k in utility value in the tornado hazard event, and $570k-$2.2M in avoided lost load and at least $220-$650 in utility value in the winter hazard scenario. In both the tornado and winter hazard scenarios, optimizing the operation of the hybrid system for resilience can lend similar value as increasing battery duration by 5 MWh for the lower capacity systems considered.

17 WIND ENERGY↗

Technology Case Study: Techno-Economic and Life Cycle Analysis for Microalgae Conversion Pathways to Fuels and Products

This technology case study report details the cost and sustainability prospects for an emerging feedstock - microalgae - converted to fuels and products via a fractionation and upgrading approach termed combined algae processing (CAP). Detailed techno-economic analysis (TEA) and life cycle analysis (LCA) are conducted for the conversion of farmed algae biomass, with two primary scenarios considering the conversion of either high-compositional-quality biomass enriched in lipids (high-lipid [HL]) or lower-quality biomass enriched in protein (high-protein [HP]). Each scenario employs a different biorefinery configuration tailored towards extracting the maximum value from the given biomass composition. The HL scenario produces fuels and non-isocyanate polyurethane (NIPU) as the primary products, while the HP scenario products fuels and a residual solid coproduct which can be used as a co-feed for producing thermoplastics. The results for the HL scenario were particularly promising, with a minimum fuel selling price (MFSP) of $\$$3.68 per gasoline gallon equivalent (GGE) and fuel GHG emissions translating to 54%-76% reduction compared to petroleum fuels depending on the coproduct handling method used. In contrast, the HP scenario faced more challenges in producing biofuels economically, projecting an MFSP of $\$$7.92/GGE despite significant revenues from the residual algae solids. LCA results for the HP case reflected a 24% reduction potential in biorefinery-level GHG emissions. However, these GHG reductions were primarily associated with the thermoplastic coproduct, which accounted for 93% of all biorefinery outputs by mass. Using a process-level allocation method, carbon intensity results were less promising, indicating a net increase in fuel GHG emissions versus petroleum fuels and highlighting the reliance of this scenario on the thermoplastic coproduct.

09 BIOMASS FUELS↗

CO2 Storage Economic Analysis: CarbonSAFE Use Case

Poster on “CO2 Storage Economic Analysis: CarbonSAFE Use Case” for the CCUS 2025 conference held in Houston, Texas March 3-5, 2025. The cost of designing, permitting, constructing, operating, and closing a CO2 storage project is of vital importance to project developers. The National Energy Technology Laboratory has developed the NRAP/SMART Technoeconomic and Liability Evaluation for Storage (TALES) Model to provide quantitative cost-based insights to support developers planning CO2 injection and storage projects. This study presents a collaborative economic analysis applying TALES with data from the San Juan Basin CarbonSAFE Phase III project led by the New Mexico Institute of Mining and Technology to estimate potential costs incurred during the implementation of a real-world commercial-scale carbon storage project. Scenario analysis was implemented in which different operational and cost attributes were varied and the associated cost implications observed. Key results data and project cost summary metrics, first-year breakeven price of CO2 ($/tonne) and net present value (NPV), are presented for base and alternative cases. Output provides a unique perspective for project stakeholders towards evaluating the influence of different operational strategies and financing approaches on overall project cost and financial viability.

carbon storage↗

Direct Air Capture Case Studies: Limestone Looping Screening-Level Analysis

A screening-level techno-economic analysis of a passive limestone looping direct air capture system is presented. The base case examined in this report does not represent an optimized system and makes many simplifying assumptions due to the nascence of the technology and lack of publicly available information. The base case serves as a reference for detailed and informative sensitivity analyses. This initial study (1) reveals that improving reaction rate and tray configuration can potentially significantly reduce cost, and (2) indicates that LL has the potential to be cost competitive with other DAC technologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Scalable and Cost-Effective Solution to the U.S. Housing Crisis: A Case Study on Locally Manufactured Modular Multifamily Housing

This case study assesses waste management efficiencies in modular buildings compared to traditional construction methods. We focus on the modular 1-bedroom Model/Z unit by Model Z Modular, LLC. As part of the collaboration between Model Z Modular and the National Renewable Energy Laboratory, we analyzed waste metrics from design through construction, contrasting these findings against conventional stick-built and site-built multifamily buildings. The Model/Z unit is part of a strategic effort to address affordable housing shortages in South Los Angeles, where household income challenges are pronounced. The unit is produced in a state-of-the-art 150,000 sq. ft. modular manufacturing facility located within the city it is serving, and has so far supported the production of over 1,500 affordable housing units. Model/Z units have been used in projects with as many as 195 units, achieving large economies of scale and time. Our analysis demonstrates that modular construction reduces waste compared to traditional methods. This reduction is achieved through precise prefabrication techniques, the implementation of new framing methods, the concentration of workforce expertise, and streamlined logistics, which optimize material use and greatly reduce on-site handling. Additionally, local manufacturing minimizes transportation needs, improving overall project efficiency. The Model/Z unit exemplifies a scalable solution for enhancing housing affordability by optimizing resource utilization and minimizing associated costs. These methods support the delivery of high-quality units at reduced expenses, addressing critical urban housing shortages effectively. This case study underscores Model Z Modular's commitment to producing affordable, quality housing while fostering economic opportunities through job creation and training programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Trends and Effects of Changes in Business Cases for Petroleum Refineries

This study investigates trends and effects in business cases for petroleum refineries with a focus on effects for the state of Oregon for finished gasoline. Recently, the Oregon Department of Energy released the 2024 Oregon Energy Security Plan (ESP) which highlighted the reliance on out of state gasoline imports primarily from refineries located in the state of Washington. This study compiled a list of recent refinery closures in the United States and analyzed the drivers and impacts each refinery closure had to its respective region. The study dives into exploring three refinery closure business cases and past events that impacted gasoline prices in Oregon. Lastly, the paper outlines a potential framework of indicators to analyze the risk of future refinery closures based on the findings. This study hopes to inform stakeholders about the vulnerabilities in Oregon’s fuel supply chain and provide information that can guide strategic planning for future energy security.

02 PETROLEUM↗

Use Case Specification

Over the past three years, the Use Case Specification project has provided scenarios that have driven the development of key E-COMP capabilities and demonstrated their application to problems that the electric power industry is facing. These scenarios have provided the basis for which each Thrust has performed technical work, tying together E-COMP work under a common umbrella. Documented in this report is a summary of the background, motivations, and work – completed or proposed – under the three E-COMP use cases pursued to date: Offshore Wind, Remote Communities on the Olympic Peninsula, and Large Electric Loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Closeout Report of BNL LDRD 23-050 A Second EIC Detector: Physics Case and Conceptual Design

This document is the closeout report for LDRD 23-050, a type-A LDRD project awarded in FY2022 under the title “ A Second EIC Detector: Physics Case and Conceptual Design ”. The project was motivated by the strong interest within the EIC community in a second general-purpose detector and interaction region, and by the recognition that such a detector is essential to fully exploit the scientific potential of the EIC over its multi-decade lifetime. The key goals of the LDRD were to (i) strengthen the case for a second EIC detector, building on the arguments already articulated in the community Yellow Report, (ii) provide a realistic detector concept that is complementary to the current project detector, ePIC, in terms of physics reach, precision, and control of systematics, and (iii) broaden the overall physics program of the EIC facility. Since a possible second detector is expected to be realized with a delay of several years relative to the first detector, the project explicitly aimed at identifying technologies that are not yet sufficiently mature for ePIC but could be deployed on the later timescale of a second detector, thereby providing genuine complementarity and room for innovation. LDRD 23-050 provided support for two postdoctoral researchers and partial support for several BNL staff members, and the effort ramped up in mid-2023. Work was carried out in close collaboration with colleagues from the EIC project, the Cold QCD and STAR groups at BNL, and with substantial input from members of the EIC User Group and the ePIC Collaboration as reflected in the author list. Over the period from October 2022 through September 2025, this team developed and refined a physics program tailored to a second detector, translated the resulting physics requirements into detector-level performance targets, and explored multiple conceptual detector layouts capable of meeting these targets within the constraints of the second interaction region. The expected outcome, as stated in the original proposal, was a document detailing the physics potential and requirements of a second EIC detector, accompanied by a comprehensive conceptual detector design and an outline of the remaining R&D needed to bring the relevant technologies to maturity. The present report summarizes the progress that has been achieved toward these goals. It consolidates the physics studies, detector concepts, and technology assessments developed under this LDRD and places them in the broader context of worldwide detector R&D. While the evolving priorities of the EIC project and the substantial community effort required to design and construct ePIC naturally limited the scope of EIC-wide activities toward a second detector during this period, the work documented here is intended to provide a foundation and a point of reference for future efforts. Whatever form a second EIC detector may ultimately take, we hope that this report will serve as a useful guide for colleagues who continue to advance this program in the near- and mid-term future.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Providing Thermal Stability for an Exascale Supercomputer: A Case Study of Frontier's Cooling System

High performance computing (HPC) systems frequently produce large dynamic power swings, even under typical operating conditions, that can present a significant challenge for their direct-liquid cooling systems. Further, the primary cooling loops that must remove this waste heat have response times measured in minutes while the underlying HPC component thermal stress is measured in seconds. The per-socket power demand for both compute processing units (CPUs) and graphic processing units ( GPUs) continues to increase with each successive generation while case temperatures are declining. New HPC systems are expected to exacerbate the challenge of these dynamic power swings and the impact on effective and timely cooling systems. This paper describes the cooling and controls system for Oak Ridge National Laboratory’s Frontier Supercomputer, the first sustained exascale system, as a case study for this situation. The cooling and control system for Frontier demonstrates specific success, but with a number of trade-offs and decisions that suggest further design and operating optimizations for the community at large to consider.

42 ENGINEERING↗

Cyber-Informed Engineering Requirements Framework Use Cases

The requirement analysis use case effort leverages the Cyber-Informed Engineering (CIE) requirements framework to examine two real-world scenarios: Battery Energy Storage System (BESS) installation at the Flatirons Campus, NLR; SCADA improvement program. This work evaluates the existing requirements for each use case, applies the CIE requirements framework, and assesses the benefits and enhancements gained compared to the current requirements. The results will advance CIE from concept to practical application by identifying key opportunities for integrating CIE principles into established engineering workflows during the requirements phase.

97 MATHEMATICS AND COMPUTING↗

Equity Considerations in Grid Planning: Case Studies Overview

This overview summarizes four case studies which highlight different approaches to energy equity taken by Hawaii, Illinois, Virginia and Wisconsin. They have started in varying places on equity integration and taken unique approaches. The case studies assess structural themes across the four states and examine common and foundational energy equity actions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Business Case Evaluation of Gas Switching Reforming (GSR) Technology: A Promising Technology for Natural Gas Reforming with Integrated CO2 Capture

Hydrogen is essential in the transition to sustainable energy, and developing low-carbon production methods is a key research focus. Traditional steam methane reforming (SMR) dominates the hydrogen industry but contributes substantially to CO2 emissions. In response, Gas Switching Reforming (GSR) has emerged as a novel process that integrates carbon capture and utilizes process heat more efficiently. Unlike other reforming methods, GSR consolidates oxidation and reduction reactions within a single reactor, which minimizes external energy inputs and simplifies scaling. Like conventional steam methane reforming (SMR), GSR can be integrated with water-gas shift and pressure swing adsorption units for pure hydrogen production. This work presents a comprehensive business case analysis of GSR technology based on experimental results in Technology Readiness Level 3, Life Cycle Assessment (LCA) and Techno-Economic (TEA) evaluation incorporating ASPEN Plus process modeling considering different configurations and energy scenarios. The TEA incorporates data from kinetic experiments from various catalysts to evaluate the GSR process under various conditions. The goal of this work is to evaluate GSR’s potential to serve as a low-carbon alternative to SMR, focusing on global warming potential and additional impact categories to evaluate a wide spectrum of environmental impacts. Comparative assessments were conducted with SMR, chemical loop reforming (CLR), and proton exchange membrane (PEM) electrolysis to explore trade-offs across environmental metrics. The environmental impact assessment of this work encompasses the entire hydrogen production lifecycle from raw material extraction to plant decommissioning, using a cradle-to-gate boundary. Preliminary findings highlight that GSR, when integrated with low-carbon energy sources, could significantly reduce environmental impacts, making it a promising candidate for low-carbon hydrogen infrastructure. The insights from this business case evaluation aim to guide industry in scale-up and commercialization of this promising clean energy technology.

03 NATURAL GAS↗

Developing Equivalent Surface Heat Transfer Input Parameters for Updated Standard 140/BESTEST Thermal Fabric Test Cases

ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs, is widely cited for evaluating software for use with performance-path energy efficiency analysis in conjunction with well-known energy-efficiency standards, including: ASHRAE Standard 90.1, the International Energy Conservation Code, and other international standards. This paper summarizes recent work to develop improved equivalent surface heat transfer input parameters for the building thermal fabric comparative test cases that comprise a portion of Standard 140. The software-to-software comparative test method allows comparison of simulation results from a wide variety of building energy simulation programs to each other. In this type of test method, it is of great importance to specify inputs that are as well-equivalenced as possible to accommodate a wide variety of input schemes for the tested programs, and thereby reduce the potential for disagreements among them in the tests. Results include new alternative constant surface coefficients that are appropriate to the test cases and demonstrate their ability to approximate the more detailed surface heat transfer models from which they are derived.

BESTEST↗

Case report: Fatal Legionella infection diagnosed via by metagenomic next-generation sequencing in a patient with chronic myeloid leukemia

Legionella is an aerobic, gram-negative, intracellular pathogen and is an important cause of community-acquired pneumonia. Legionella pneumophila is the most common causative agent of Legionella pneumonia. Clinical diagnosis of Legionella pneumonia is challenging due to the lack of specific clinical manifestations and the low positive rates of conventional pathogen detection methods. In this study, we report a case of a patient with chronic myeloid leukemia who developed rigors and high fever after chemotherapy and immunotherapy. Chest computed tomography revealed consolidation in the left lower lobe of the lung and ground-glass opacities in both lower lobes. Multiple blood cultures showed Escherichia coli , Staphylococcus aureus , Bacillus licheniformis , and positive results in the β-D-glucan test (G test). The patient was treated with various sensitive antimicrobial agents, including meropenem plus fluconazole, meropenem plus carpofungin, and vancomycin. Unfortunately, the patient’s condition gradually worsened and eventually resulted in death. On the following day of death, metagenomic next-generation sequencing (mNGS) of 1whole blood revealed L. pneumophila pneumonia with concurrent bloodstream infection (blood mNGS reads 114,302). These findings suggest that when conventional empirical antimicrobial therapy proves ineffective for critically ill patients with pneumonia, the possibility of combined Legionella infection must be considered, and mNGS can provide a diagnostic tool in such cases.

Bu, Chunhong↗