Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “carbon defects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Reduced annealing temperatures in silicon solar cells

Cells irradiated to a fluence of 5x10,000,000,000,000/square cm showed short circuit current on annealing at 200 C, with complete annealing occurring at 275 C. Cells irradiated to 100,000,000,000,000/square cm showed a reduction in annealing temperature from the usual 500 to 300 C. Annealing kinetic studies yield an activation energy of (1.5 + or - 2) eV for the low fluence, low temperature anneal. Comparison with activation energies previously obtained indicate that the presently obtained activation energy is consistent with the presence of either the divacancy or the carbon interstitial carbon substitutional pair, a result which agrees with the conclusion based on defect behavior in boron-doped silicon.

Weinberg, I.↗

Morphological Evidence for an Exclusively Inorganic Origin for Magnetite in Martian Meteorite ALH84001

The origin of magnetite crystals in Martian Meteorite ALH84001 is the focus of a debate about the possibility of past (and present) life on Mars. McKay et al. originally suggested that some of the magnetite crystals associated with carbonate globules in Martian Meteorite ALH84001 are biogenic in ori-gin, because they are single magnetic domain, free of crystalline defects, chemically pure, and coexist with other metastable phases in apparent disequilibrium. Thomas-Keprta et al. reported that a subpopulation of magnetite crystals (approx. 25%) associated with carbonate globules in ALH84001 and magnetite crystals produced by magnetotactic bacterial strain MV-1 have similar morphologies with crystal elongation along the [111] crystallographic axis that they describe as "truncated hexa-octahedral" ([111-THO]) magnetite. Along with several other properties, the [111]-THO morphology has been proposed to constitute a biomarker (i.e., formed only in biogenic processes), so that the presence of [111]-THO magnetite in ALH84001 may be evidence for past life on Mars.

Golden, D. C.↗

Radiation Effects in Graphite

Graphite has been a core structural material and neutron moderator since the first man-made chain reaction experiment in Chicago. This article will discuss the requirements of what makes graphite a good solid moderator. The manufacture and properties of some currently available near-isotropic and isotropic grades are described. The major features of a graphite moderated reactors are briefly outlined. Displacement damage and the induced structural and dimensional changes in graphite are described. Recent characterization work on nano-carbons and oriented pyrolytic graphites that have shed new light on graphite defect structures are reviewed, and the effect of irradiation temperature on the defect structures is highlighted. Changes in the physical properties of nuclear graphite caused by neutron irradiation are reported. Finally, the importance of irradiation induced creep is presented, along with current models and their deficiencies.

Campbell, Anne↗

Flame Synthesis of Single- and Multi-Walled Carbon Nanotubes and Nanofibers

Metal-catalyzed carbon nanotubes are highly sought for a diverse range of applications that include nanoelectronics, battery electrode material, catalysis, hydrogen storage media and reinforcing agents in polymer composites. These latter applications will require vast quantities of nanotubes at competitive prices to be economically feasible. Moreover, reinforcing applications may not require ultrahigh purity nanotubes. Indeed, functionalization of nanotubes to facilitate interfacial bonding within composites will naturally introduce defects into the tube walls, lessening their tensile strength. Current methods of aerosol synthesis of carbon nanotubes include laser ablation of composite targets of carbon and catalyst metal within high temperature furnaces and decomposition of a organometallics in hydrocarbons mixtures within a tube furnace. Common to each approach is the generation of particles in the presence of the reactive hydrocarbon species at elevated temperatures. In the laser-ablation approach, the situation is even more dynamic in that particles and nanotubes are borne during the transient cooling phase of the laser-induced plasma for which the temperature far exceeds that of the surrounding hot gases within the furnace process tube. A shared limitation is that more efficient methods of nanoparticle synthesis are not readily incorporated into these approaches. In contrast, combustion can quite naturally create nanomaterials such as carbon black. Flame synthesis is well known for its commercial scalability and energy efficiency. However, flames do present a complex chemical environment with steep gradients in temperature and species concentrations. Moreover, reaction times are limited within buoyant driven flows to tens of milliseconds. Therein microgravity can greatly lessen temperature and spatial gradients while allowing independent control of flame residence times. In preparation for defining the microgravity experiments, the work presented here focuses on the effect of catalyst particle size and reactant gas in 1g.

VanderWal, R. L.↗

Addressing wellbore integrity and thief zone permeability using microbially-induced calcium carbonate precipitation (MICP): A field demonstration

Microbially-induced calcium carbonate precipitation (MICP) is an emerging biotechnology for wellbore integrity applications including sealing defects in wellbore cement and modifying the permeability of rock formations. The goal of this field demonstration was to characterize a failed waterflood injection well and provide proof of principle that MICP can reduce permeability in the presence of oil using conventional oilfield fluid delivery methods. Here we compared well logs performed at the time the well was drilled with ultrasonic logs, sonic cement evaluation, and temperature logs conducted after the well failed. Analysis of these logs suggested that, rather than entering the target waterflood formation, injectate was traveling through defects in the well cement to a higher permeability sandstone layer above the target formation. Sporosarcina pasteurii cultures and urea-calcium media were delivered 2290 ft (698 m) below ground surface using a 3.75 gal (14.2 L) slickline dump bailer to promote mineralization in the undesired flow paths. By Day 6 and after 25 inoculum and 49 calcium media injections, the injectivity [gpm/psi] had decreased by approximately 70%. This demonstration shows that 1) common well logs can be used to identify scenarios where MICP can be employed to reduce system permeability, remediate leakage pathways, and improve waterflood efficiency, and 2) MICP can occur in the presence of hydrocarbons.

42 ENGINEERING↗

Carbon nanomaterials–polymer composites for perovskite solar cells: preparation, properties and applications

Perovskite solar cells (PSCs) are a rising star in the photovoltaic industry, which achieved an enormous breakthrough in terms of efficiency from an initial 3.8% in 2009 to 25.7% in 2021. Here, the major challenge to bring perovskite solar cells commercially available is the poor long-term device stability. The defects in perovskite and energy loss originating from charge recombination limit the efficiency of perovskite solar cells. Carbon–polymer composites, which feature superb electrical conductivity, outstanding carrier mobility, remarkable flexibility and superior heat and moisture stability, have attracted considerable attention to tackle these issues. With their multifunctional properties, carbon–polymer composites can play various roles in almost every component in the perovskite solar cell architecture. In this review article, recent progress concerning the utilization of carbon–polymer composites in different components in PSCs (i.e., perovskite additives, electrodes, encapsulation layers and charge transport layers) is comprehensively overviewed. Then, future research directions and opportunities toward high-performance perovskite solar cells utilizing carbon–polymer composites are presented.

36 MATERIALS SCIENCE↗

Exploring the Storage Mechanism of Alkali Ions in Non-Graphitic Hard Carbon Anodes

This study aims to develop high-capacity hard carbon anode materials for alkali-ion batteries by controlling the microstructures of non-graphitic hard carbon through an annealing protocol and investigating the effects on the alkali-ion storage mechanisms using physical, chemical, and electrochemical analytical techniques. The hard carbon materials were synthesized at temperatures ranging from 900 °C to 1600 °C. Those synthesized at 1100 °C with high surface area and abundant defects exhibited the highest reversible capacity in Li- and K-ion systems, with the storage dominated by surface-adsorption mechanisms. In contrast, the hard carbon compounds prepared at 1400 °C with numerous curve-featured pores delivered the highest reversible capacity in the Na-ion system, indicating that these pores are the preferred Na-ion storage sites, particularly in low-voltage plateau regions. This study provides a comprehensive understanding of the relationship between microstructures and alkali-ion storage mechanisms in non-graphitic hard carbon and highlights the importance of tailoring the microstructures of hard carbon to achieve high specific capacity for the desired alkali-ion species.

25 ENERGY STORAGE↗

The estimation of residual strength of composites by acoustic emission

The strength of unidirectional fibrous composite materials was measured as a function of the acoustic emission. Specimens of glass fibers and carbon fibers in an epoxy matrix were tested to fracture. Many of the specimens were with existing defects. It was shown, analytically and experimentally, that defective material starts to emit acoustic waves at a much lower stress level than nondefective material. It was found that for glass fiber material, the ultimate strength of the composite is proportional to the stress level for which a specific number of acoustic emission counts was reached. For carbon fiber material, this phenomenon is less pronounced.

Rotem, A.↗

Monolayer Films of Binary Metal Oxide Nanoparticles for Carbon Nanotube Synthesis

Binary metal oxide nanoparticles (biMO-NPs) combining transition and main-group metals with well-organized atomic architectures have unique potential as robust and economical heterogeneous catalysts. Herein, metal oxide nanoparticles (CoAlxOy) using cobalt and aluminum were synthesized, and their structure, morphology, and chemical composition were investigated using various characterization techniques. The biMO-NPs, which had a Gaussian-type size distribution (∼6 nm), were assembled on plain silicon substrates modified chemically with linker molecules bearing suitable end groups. Surface analysis revealed an ordered, uniform, close-packed arrangement of biMO-NPs forming a monolayer architecture with nanoscale thickness (∼12 nm), high surface uniformity, and negligible defects. The nanoparticle monolayer film (NP-MF) was employed as a catalyst to grow carbon nanotube (CNT) forests via the thermal chemical vapor deposition (CVD) method, similar to those grown from catalyst thin films deposited by physical vapor deposition. Structural characterization confirmed the growth of a dense, uniform, high-quality vertically aligned carbon nanotube (VA-CNT) forest with a length of ∼125 µm, which is comparable to the VA-CNTs grown from expensive thin films. Thus, CNT growth was successfully catalyzed by the biMO-NPs, highlighting a simple and inexpensive alternative for catalyst deposition. In this innovative wet-chemistry approach, the catalyst and catalyst support are combined within a single nanoparticle before NP-MF assembly. Interestingly, this approach provides a scalable and cost-effective pathway for CNT growth, eliminating the need for expensive thin deposition techniques.

Regmi, Bishow [University of Cincinnati]↗

In-Situ Detection of Process-Induced Porosity During Cure of Out-of-Autoclave Composites

Composite materials offer unique benefits in aerospace applications, including high strength-to-weight ratio, and are becoming increasingly used by industry manufacturers. Current manufacturing and processing methods can lead to defects in the composites, which are identified after fabrication using inspection methods. This study utilized a high-temperature ultrasonic inspection system to detect process-induced porosity in an out-of-autoclave (OOA) composite panel during cure. In order to perform ultrasonic scans in-situ during cure, the system needed to be able to operate at oven temperatures up to 200 °C. There are no commercially available ultrasonic scanning systems that can operate continuously at these temperatures, so an enclosure was fabricated to insulate the ultrasonic system in the curing oven. The enclosure housed a MISTRAS® motorized X-Y raster scanner and contact transducer (Olympus® X2002). The Olympus® X2002 contact transducer is a continuous high-temperature delay line transducer with a center frequency of 2.25 MHz. In order to prevent the inside of the enclosure from reaching high temperatures, a sparge pipe inside the cooling enclosure was connected to a liquid nitrogen (LN2) tank outside of the oven via insulated hoses. The cooling system was automatically controlled by a temperature controller that was programmed to open a solenoid valve along the hose at 31 ℃ and close at 28 ℃ inside the cooling enclosure. When the solenoid valve was open, LN2 would flow from the LN2 tank and vaporize prior to reaching cooling enclosure. A U-shaped sparge pipe had holes drilled along its length to uniformly introduce cold nitrogen gas into the cooling enclosure. This prevented the motors from ever reaching the maximum desired operating temperature of 38 ℃. In the bottom of the enclosure, the tool plate was placed with the composite facing the outside of the enclosure, exposing it to the temperatures of the oven. The tool plate was 63.5 mm thick borosilicate glass, which was chosen for its low ultrasonic attenuation and moderate thermal conductivity. A thin layer of ultrasonic couplant was placed on the tool plate. The transducer sent and received ultrasonic waves through the tool plate into the composite. A MISTRAS® Remote UT System performed all wave generation, analog to digital conversion, and data acquisition and processing. The transducer was connected directly to the Remote UT System via a high-temperature BNC cable (CD International, RG-316). Polyimide insulated copper wire was used to connect the scanner to a 2-axis motor drive, which was connected to the Remote UT System. The motor drive and Remote UT System were located outside the industrial oven. A diagram of the ultrasonic system is shown in Figure 1. Figure 1: Diagram of ultrasonic in-situ defect detection system. In this study, a porosity gradient was introduced into the carbon fiber reinforced polymer (CFRP) composite through a misfit of the part and caul plate. A 24-ply quasi-isotropic ([0/90, ±45]12S) composite panel was laid up using Newport® AS4C-M/NB321 out-of-autoclave (OOA) plain weave (PW) prepreg (42% resin content, 195 g/m2). The first 16 plies were 203 mm × 203 mm. Ply drops were incorporated into the panel by decreasing the length of plies 17-24. The sizes of each ply are included in Table 1. All plies were centered along their length (x-axis) creating a trapezoidal type cross-section. Table 1: Ply sizes Plies Length (mm) Width (mm) 1-16 203 203 17-18 102 203 19-20 85 203 21-22 68 203 23-24 51 203 A 15-5 stainless steel caul plate (Size: 203 × 203 × 1.2 mm) was placed on the laminate. The composite and caul plate were vacuum bagged to the tool plate. Per the product datasheet, Newport 321 can be cured between 121 °C and 149 °C, depending on service temperature, with a hold for 90-120 minutes. Based on prior thermal testing of the cooling enclosure, the desired composite temperature cycle could be attained when the air temperature of the oven was ramped to 160 °C at a rate of 1.7 °C/min with a 3 hour hold. The extended hold was not necessary to cure the composite, but did allow for additional scans at the cure temperature during preliminary testing. The composite panel was under vacuum pressure for the entire cure cycle. Under vacuum, the caul plate deformed causing high and low pressure regions. The low-pressure regions formed high porosity in the composite part. The ultrasonic data collected showed that the inspection system was able to monitor the evolution of porosity within the composite throughout the cure cycle. Fifty scans of a 203 mm × 51 mm (8 in. × 2 in.) area of the composite were completed throughout the cure cycle. The scan speed was set to 43 mm/s in the x-direction and 36 mm/s in the y-direction, with a 1.0 mm/pixel resolution in both directions. Each scan took approximately five minutes to complete. Figure 2 shows C-scan amplitude data (top view) from one scan during the cure cycle. The color map indicates the maximum amplitude (%) measured with a time gate that contains reflections from the back surface (furthest from the transducer in contact with the caul plate) of the composite. Because porosity in the composite increases the ultrasonic attenuation in the composite part, a higher amplitude (red) indicates low porosity and a lower amplitude (blue) indicates high porosity. The regions where the caul plate was applying increased pressure (center and ends of the panel) resulted in reduced porosity, whereas the ply drop regions had reduced pressure and thus had higher porosity. Figure 2: Amplitude C-scan (top view) of OOA composite from one scan during the 160 °C temperature hold. Higher amplitude (red) indicates low porosity. Lower amplitude (blue) indicates high porosity. A B-scan is a two-dimensional image plotting the ultrasonic signals from a single y-position at every x-location of the composite panel. The travel time (μs) of the ultrasonic wave (representing the through-thickness location) is plotted along the y-axis, and the ultrasonic wave signal is represented as a contour map. Based on the B-scan data, the location of the defects with respect to the composite thickness was able to be determined. The ply drop regions had high porosity near the front (tool plate) surface of the composite (Figure 3). Figure 3: B-scan (cross-section view) of OOA composite from one scan during the 160 °C temperature hold. Using the data obtained from amplitude C-scans and B-scans throughout the cure cycle, the high and low porosity regions within the composite laminate were detected and localized with high spatial resolution. This paper will discuss the evolution of porosity content in the OOA composite during cure. OOA tests aided the transition of this system to an autoclave, which is the primary method of curing aerospace-grade thermoset composites.

Tyler B. Hudson↗

Pulling thin single crystal silicon wafers from a melt: The new leading-edge solar substrate

The Floating Silicon Method (FSM) has been established as a viable, stable method for growing single crystal ribbons directly from a silicon melt. With intense helium jet cooling to drive the linear progress of a [111] facet, pulled in the <110> direction, ribbons in the 0.6 – 3.0 mm thickness range can be grown at linear growth rates from 0.3 mm/s to >6 mm/s as reported in the literature. We report on recent progress towards growing (100) oriented ribbons with a net thickness of less than 200 microns and a ribbon width up to 18 cm using a stable, continuous process in the Leading Edge prototype furnace. Here, the 3D details of the single crystal growth are explained by extending the mechanics of the Limit Cycle Theory, with novel Internal Side Effect morphology described by a proposed Facet Flow Theory. Grown-in crystalline defect distributions are described as well as values of critical impurities like oxygen, carbon, dopants, and metals that are relevant for use as wafers for solar cells.

14 SOLAR ENERGY↗

Carbon nanospike coated nanoelectrodes for measurements of neurotransmitters

Here, carbon nanoelectrodes enable the detection of neurotransmitters at the level of single cells, vesicles, synapses and small brain structures. Previously, the etching of carbon fibers and 3D printing based on direct laser writing have been used to fabricate carbon nanoelectrodes, but these methods lack the ability of mass manufacturing. In this paper, we mass fabricate carbon nanoelectrodes by growing carbon nanospikes (CNSs) on metal wires. CNSs have a short, dense and defect-rich surface that produces remarkable electrochemical properties, and they can be mass fabricated on almost any substrate without using catalysts. Tungsten wires and niobium wires were electrochemically etched in batch to form sub micrometer sized tips, and a layer of CNSs was grown on the metal wires using plasma-enhanced chemical vapor deposition (PE-CVD). The thickness of the CNS layer was controlled by the deposition time, and a thin layer of CNSs can effectively cover the entire metal surface while maintaining the tip size within the sub micrometer scale. The etched tungsten wires produced tapered conical nanotips, while the etched niobium wires were long and thin. Both showed excellent sensitivity for the detection of outer sphere ruthenium hexamine and the inner sphere test compound ferricyanide. The CNS nanosensors were used for the measurement of dopamine, serotonin, ascorbic acid and DOPAC with fast-scan cyclic voltammetry. The CNS nanoelectrodes had a large surface area and numerous defect sites, which improved the sensitivity, electron transfer kinetics and adsorption. Finally, the CNS nanoelectrodes were compared with other nanoelectrode fabrication methods, including flame etching, 3D printing, and nanopipettes, which are slower to make and more difficult for mass fabrication. Thus, CNS nanoelectrodes are a promising strategy for the mass fabrication of nanoelectrode sensors for neurotransmitters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Switching and Rectification in Carbon-Nanotube Junctions

Multi-terminal carbon-nanotube junctions are under investigation as candidate components of nanoscale electronic devices and circuits. Three-terminal "Y" junctions of carbon nanotubes (see Figure 1) have proven to be especially interesting because (1) it is now possible to synthesize them in high yield in a controlled manner and (2) results of preliminary experimental and theoretical studies suggest that such junctions could exhibit switching and rectification properties. Following the preliminary studies, current-versus-voltage characteristics of a number of different "Y" junctions of single-wall carbon nanotubes connected to metal wires were computed. Both semiconducting and metallic nanotubes of various chiralities were considered. Most of the junctions considered were symmetric. These computations involved modeling of the quantum electrical conductivity of the carbon nanotubes and junctions, taking account of such complicating factors as the topological defects (pentagons, heptagons, and octagons) present in the hexagonal molecular structures at the junctions, and the effects of the nanotube/wire interfaces. A major component of the computational approach was the use of an efficient Green s function embedding scheme. The results of these computations showed that symmetric junctions could be expected to support both rectification and switching. The results also showed that rectification and switching properties of a junction could be expected to depend strongly on its symmetry and, to a lesser degree, on the chirality of the nanotubes. In particular, it was found that a zigzag nanotube branching at a symmetric "Y" junction could exhibit either perfect rectification or partial rectification (asymmetric current-versus-voltage characteristic, as in the example of Figure 2). It was also found that an asymmetric "Y" junction would not exhibit rectification.

Srivastava, Deepak↗

Local Guided Wavefield Analysis for Characterization of Delaminations in Composites

Delaminations in composite laminates resulting from impact events may be accompanied by minimal indication of damage at the surface. As such, inspection techniques are required to ensure defects are within allowable limits. Conventional ultrasonic scanning techniques have been shown to effectively characterize the size and depth of delaminations but require physical contact with the structure. Alternatively, a noncontact scanning laser vibrometer may be used to measure guided wave propagation in the laminate structure. A local Fourier domain analysis method is presented for processing guided wavefield data to estimate spatially-dependent wavenumber values, which can be used to determine delamination depth. The technique is applied to simulated wavefields and results are analyzed to determine limitations of the technique with regards to determining defect size and depth. Finally, experimental wavefield data obtained in quasi-isotropic carbon fiber reinforced polymer (CFRP) laminates with impact damage is analyzed and wavenumber is measured to an accuracy of 8.5% in the region of shallow delaminations. Keywords: Ultrasonic wavefield imaging, Windowed Fourier transforms, Guided waves, Structural health monitoring, Nondestructive evaluation

Rogge, Matthew D.↗

Modeling ablator defects as a source of mix in high-performance implosions at the National Ignition Facility

Recent indirect drive inertial confinement fusion implosions on the National Ignition Facility (NIF) [Spaeth et al., Fusion Sci. Technol. 69, 25 (2016)] have crossed the threshold of ignition. However, performance has been variable due to several factors. One of the leading sources of variability is the quality of the high-density carbon (HDC) shells used as ablators in these experiments. In particular, these shells can have a number of defects that have been found to correlate with the appearance of ablator mix into the hot spot and a degradation in nuclear yield. These defects include pits on the ablator surface, voids in the ablator bulk, high-Z debris from the Hohlraum wall that adheres to the capsule surface, and finally the inherent granular micro-structure of the crystalline HDC itself. This paper summarizes high-resolution modeling of each of these mix sources in two recent high-performance NIF implosion experiments. The simulated impact from a range of individual capsule defects is found to be broadly consistent with the trends seen in experiment, lending credence to the modeling results and the details of the mixing process that they reveal. Interestingly, modeling of the micro-structure inherent to HDC shows that this perturbation source results in considerable mixing of the deuterium–tritium fuel with ablator material during the implosion. The reduction in fuel compression from this mix results in an approximately factor of two reduction in neutron yield in current implosions and emphasizes the importance of mitigating this significant performance degradation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MoS 2 nanosheet integrated electrodes with engineered 1T-2H phases and defects for efficient hydrogen production in practical PEM electrolysis

Low electrical conductivity and poor accessibility of MoS 2 reaction sites raise great challenges in maximizing the triple-phase-boundary (TPB) sites of MoS 2 -based electrodes and minimizing ohmic losses for efficient hydrogen evolution reaction (HER) in practical proton exchange membrane (PEM) water electrolysis. Herein, we report a scalable hydrothermal approach to fabricate ionomer-free integrated electrodes with engineered 1 T-2 H heterophase and defect-rich MoS 2 nanosheets (MoS 2 NSs) in-situ grown onto the carbon fiber paper (CFP). With an ultralow loading of 0.14 mg/cm 2 , a small voltage of 2.25 V was obtained at 2000 mA/cm 2 in a practical cell with Nafion115 membrane, which outperforms all previously reported high-loading non-precious catalyst-based electrodes. Impressively, it shows 44 times higher mass activity than a high-loading and ionomer-mixed MoS 2 assemblies electrode. Furthermore, this work builds a bridge from catalyst optimization to electrode fabrication and provides a promising direction for improving intrinsic catalytic activity, electrode conductivity and stability for practical PEM water electrolysis.

1T-2H heterophase↗

Long-Term Structural and Chemical Stability of Carbon Electrodes in Vanadium Redox Flow Battery

Predicting the performance decay in carbon electrodes is critical to maximizing the longevity of redox flow battery (RFB) systems. This study investigates the effect of long-term cycling (over 8000 cycles) on the structural and chemical evolution of carbon electrodes. We find that the microstructural aspects such as graphitic stacking order and interlayer spacing along with overall morphological construct remains largely unchanged even after the prolonged cycling process. Conversely, significant changes in surface chemistry such as evolution of functional groups and point defects are evident from our combined multimodal spectroscopic and computational analysis. The XPS and FTIR analysis reveals chemical absorption of chloride counter anions at point defects within graphitic surface. Additionally, our results suggest that vanadium cation plays an important role in counter anion-carbon surface interaction and subsequently the surface chemistry evolutions. Our findings provide insights about surface chemical evolution that is critical for predicting electrode performance and longevity of RFB.

Modachur Sivakumar, Bhuvaneswari↗

Enhancing Electrochemical CO2 Conversion by Controlling Electrocatalysts' Structure

Electrochemical reduction of CO2 (CO2R) to valuable, carbon-neutral chemical feedstocks and storable fuels driven by renewable electricity has been recognized as one of the promising pathways to mitigate the greenhouse effect, reduce global demand for fossil fuels, achieve carbon neutrality, and create sustainable energy. Tremendous ongoing efforts have focused on controlling the morphology, composition, structure, size, defects, etc., of the electrocatalysts to improve product selectivity, activity, and durability to approach the feasibility of practical applications (current density higher than 200 mA/cm2 and lifetime ~1,000 hr+). This presentation will discuss how the geometry and surface composition of novel copper- and tin-based catalysts would maximize the CO2 conversion to carbon monoxide and liquid formic acid/formate in both common aqueous H-cell and electrolyzer configurations. Several spectroscopic, microscopic, and electrochemical characterization tools have been utilized to correlate the changes in the structural, physico-chemical, and electronic properties with the catalytic activity. Our work provides additional electrocatalyst design considerations for high-performance CO2 electrolysis.

Nguyen Phan, Thuy Duong↗