Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “builders”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

TaC Studios New Construction Test House

As part of the NAHB Research Center Industry Partnership, Southface partnered with TaC Studios, an Atlanta based architecture firm specializing in residential and light commercial design, on the construction of a new test home in Atlanta, GA, in the mixed humid climate zone. This home will serve as a model home for the builder partner and addresses Building America energy savings targets through the planning and implementation of a design package will serve as a basis of design for the builder partner’s future homes. As a BA test house, this home will be evaluated to detail whole house energy use, end use loads, and HVAC and hot water efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing Foundation Insulation Strategies for the 2012 International Energy Conservation Code in Cold Climate New Home Construction

While the International Energy Conservation Code 2012 (IECC 2012) has been adopted at a national level, only two cold climate states have adopted it as their new home energy code. Understanding the resistance to adoption is important in assisting more states accept the code and engage deep energy strategies nationwide. This three-part assessment by the NorthernSTAR Building America Partnership was focused on foundation insulation R-values for cold climates and the design, construction, and performance implications. In Part 1 a literature review and attendance at stakeholder meetings held in Minnesota were used to assess general stakeholder interest and concerns regarding proposed code changes. Part 2 includes drawings of robust foundation insulation systems that were presented at one Minnesota stakeholder meeting to address critical issues and concerns for adopting best practice strategies. In Part 3 a sampling of builders participated in a telephone interview to gain baseline knowledge on insulation systems used to meet the current energy code and how the same builders propose to meet the new proposed code.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Taking the Challenge at Singer Village. A Cold Climate Zero Energy Ready Home

After progressively incorporating ENERGY STAR® for Homes Versions 1, 2, and 3 into its standard practices over the years, this builder, Brookside Development, was seeking to build an even more sustainable product that would further increase energy efficiency, while also addressing indoor air quality, water conservation, renewable-ready, and resiliency. These objectives align with the framework of the DOE Challenge Home program, which "builds upon the comprehensive building science requirements of ENERGY STAR for Homes Version 3, along with proven Building America innovations and best practices. Other special attribute programs are incorporated to help builders reach unparalleled levels of performance with homes designed to last hundreds of years." Consortium for Advanced Residential Buildings (CARB) partnered with Brookside Development on the design optimization and construction of the first home in a small development of seven planned new homes being built on the old Singer Estate in Derby, CT.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings

While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of Consortium for Advanced Residential Building's (CARB’s) multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.

2012 IECC↗

Measure Guideline: Implementing a Plenum Truss for a Compact Air Distribution System

This Measure Guideline presents the steps to implement a compact duct system inside an attic bulkhead (plenum truss) of a one-story, slab-on-grade home. In a compact duct design, ductwork runs are reduced in length to yield a smaller and more compact duct system. Less energy will be lost through ductwork if the ducts are contained within the thermal enclosure of the house. These measures are intended for the production builder working to meet the 2012 International Energy Conservation Code (IECC) requirements and keep the ductwork within the thermal enclosure of the house. This measure of bringing the heating, ventilation and air conditioning (HVAC) equipment and ductwork within the thermal enclosure of the house is appropriate for the builder wishing to avoid cathedralizing the insulation in the attic space (i.e., locating it at the underside of the roof deck rather than along the attic floor) or adding dropped soffits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comfort in High-Performance Homes in a Hot-Humid Climate

"9IBACOS monitored 37 homes during the late summer and early fall of 2014 in a hot and humid climate to better understand indoor comfort conditions. These homes were constructed in the last several years by four home builders that offered a comfort and performance guarantee for the homes. The homes were located in one of four cities: Tampa, Florida; Orlando, Florida; Houston, Texas; and San Antonio, Texas. Temperature and humidity data were collected from the thermostat and each room of the house using small, battery-powered data loggers. To understand system runtime and its impact on comfort, supply air temperature also was measured on a 1-minute interval. Overall, the group of homes only exceeded a room-to-room temperature difference of 6 degrees F for 5% of the time. For 80% of the time, the rooms in each house were within 4 degrees F of each other. Additionally, the impact of system runtime on comfort is discussed. Finally, measurements made at the thermostat were used to better understand the occupant operation of each cooling system's thermostat setpoint. Builders were questioned on their perceived impact of offering a comfort and performance guarantee. Their feedback, which generally indicates a positive perception, has been summarized in the report.

"9residential↗

Performance and Costs of Ductless Heat Pumps in Marine-Climate High-Performance Homes -- Habitat for Humanity The Woods

The Woods is a Habitat for Humanity (HFH) community of ENERGY STAR Homes Northwest (ESHNW)-certified homes located in the marine climate of Tacoma/Pierce County, Washington. This research report builds on an earlier preliminary draft 2014 BA report, and includes significant billing analysis and cost effectiveness research from a collaborative, ongoing Ductless Heat Pump (DHP)research effort for Tacoma Public Utilities (TPU) and Bonneville Power Administration (BPA). This report focuses on the results of field testing, modeling, and monitoring of ductless mini-split heat pump hybrid heating systems in seven homes built and first occupied at various times between September 2013 and October 2014. The report also provides WSU documentation of high-performance home observations, lessons learned, and stakeholder recommendations for builders of affordable high-performance housing such as HFH. Tacoma Public Utilities (TPU) and Bonneville Power Administration (BPA). This report focuses on the results of field testing, modeling, and monitoring of ductless mini-split heat pump hybrid heating systems in seven homes built and first occupied at various times between September 2013 and October 2014. The report also provides WSU documentation of high-performance home observations, lessons learned, and stakeholder recommendations for builders of affordable high-performance housing such as HFH.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancing Replicable Solutions for High-Performance Homes in the Southeast

Southface Energy Institute (Southface) partnered with owners and/or builders with various market constraints and ultimate goals for three projects in different climate zones: Savannah, GA (CZ 2), Clemson, SC (CZ 3), and LaFayette, GA (CZ 4). This report documents the design process, computational energy modeling, construction, envelope performance metrics, long-term monitoring results, and successes and failures of the design and execution of these high performance homes. The three bedroom/two bathroom test home in Savannah Gardens on an elevated slab foundation has a semi-conditioned, encapsulated attic. A neighboring home built to EarthCraft specifications was also monitored as a control for exterior foam insulation and a heat pump water heater (HPWH). For the JMC Patrick Square, a single-story project in Clemson, the small-scale production builder wanted to increase their level of energy efficiency beyond their current green building practices, including bringing ducts into conditioned space. Through a combination of upgrade measures the team met this goal and achieved many Zero Energy Ready Home requirements. LaFayette Housing Authority undertook a development of 30 affordable rental housing units in 15 duplexes in LaFayette, GA. Because they would be long-term owners, their priorities were low utility bills for the residents and durable, maintainable buildings. The team employed BEopt to optimize buildling envelope and systems choices, including 2x6 advanced framed walls, insulated slab, and heat pump water heater in a utility closet which was ducted to/from an encapsulated attic.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative Cooling Season Performance of Air Distribution Systems in Multistory Townhomes

IBACOS investigated the performance of a small-diameter high velocity heat pump system compared to a conventional system in a new construction triplex townhouse. A ductless heat pump system also was installed for comparison, but the homebuyer backed out because of aesthetic concerns about that system. In total, two buildings, having identical solar orientation and comprised of six townhomes, were monitored for comfort and energy performance. Results show that the small-diameter system provides more uniform temperatures from floor to floor in the three-story townhome. No clear energy consumption benefit was observed from either system. The builder is continuing to explore the small-diameter system as its new standard system to provide better comfort and indoor air quality. The homebuilder also explored the possibility of shifting its townhome product to meet the U.S. Department of Energy Challenge Home National Program Requirements. Ultimately, the builder decided that adoption of these practices would be too disruptive midstream in the construction cycle. However, the townhomes met the ENERGY STAR Version 3.0 program requirements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mini-Split Heat Pump Evaluation and Zero Energy Ready Home Support

This project was created from a partnership between the U.S. Department of Energy’s (DOE’s) Building America research team IBACOS, Inc. and Imagine Homes, a production homebuilder of high-performance homes in San Antonio, Texas—a hot-humid climate. The primary purpose was to evaluate the performance of a multihead mini-split heat pump (MSHP) space-conditioning system, which consists of ducted and ductless indoor units, in maintaining uniform comfort in an occupied test house. The research team evaluated the MSHP space-conditioning strategy for its effectiveness in achieving uniform temperature and relative humidity (RH) levels throughout the test house and for overall constructability and cost. This evaluation was based on data that were collected from short-term tests and monitoring during 1 year of occupancy, as well as from builder and occupant feedback. Design considerations for integrating an MSHP system into the builder’s full range of production home designs were also explored, with a focus on minimizing the cost and complexity of the system design while meeting the thermal loads of the house and providing occupant comfort according to ANSI/ASHRAE Standard 55-2010 (ASHRAE 2010a).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving Energy Efficiency of Air Separation via Hollow Fiber Sorbents

This report summarizes the work performed under the Department of Energy’s National Energy Technology Laboratory (DOE-NETL) Advanced Energy Systems Program award number DE-FE0026163 Improving Energy Efficiency of Air Separation via Hollow Fiber Sorbents. The overall objective of the project was to develop technology to produce oxygen for use in coal gasification processes at a significantly lower cost than that of the commercial state-of-the-art technology. The focus of the project was development and optimization of hollow fiber sorbents for use in a pressure swing adsorption (PSA) process for producing oxygen from air. The key technical advancement under this program was the development of a hollow fiber sorbent capable of producing oxygen in a PSA process. PSAs produce oxygen by using a beaded zeolite material (typically lithium exchanged zeolites or LiX) that selectively adsorb nitrogen over oxygen. For a fiber to adsorb nitrogen, LiX needed to be integrated into a polymer fiber and then activated at over 350C to remove residual moisture. After screening multiple materials and process techniques, Matrimid/LiX hollow fibers were produced that were able to withstand the activation and had crystalline nitrogen capacity close to pure LiX crystals. The fibers were dual layer fibers with a barrier layer isolating the hollow bore from the LiX embedded layer. The barrier layer was formed from an Ultem® based solution. The hollow bore was intended for encapsulating phase change materials to ensure isothermal PSA operation. Modeling work from the project suggested that the benefits of this additional complexity were marginal, thus the team fabricated non-hollow fibers comprised of Matrimid and LiX. The Matrimid/LiX fibers were loaded into a module and tested on a bench scale PSA unit. The fibers were able to separate oxygen from air, but the purity and recovery were lower than expected and lower than traditional beaded LiX zeolites, although modeling results suggested that the bed sizes for fiber sorbents could be half the size of a beaded LiX bed. Additional work will be needed to understand the shortfall and to produce fiber sorbent modules with performance equal to the targets set for this program. In addition to producing fibers, modeling work was carried out at both the fiber level and process level to guide both fiber sorbent development and to determine the optimal process conditions for a PSA using fiber sorbents. A 2D hollow fiber model was developed in gPROMS Model Builder. This model was based on literature data for mass transfer and other parameters. This model used a basic single bed PSA process to determine important fiber properties and process conditions for achieving high oxygen recovery. The preliminary 2D fiber model was a valuable tool, however, for step-out technologies, such as a PSA process with fiber sorbents, intelligent optimization and plant control was needed to effectively determine minimum power designs. Therefore, a gPROMS Process Builder-based optimization tool was developed with an “Automated Cycle Optimizer” model that was able to determine optimal cycle conditions for a fiber sorbent PSA. The results from the optimizer were used in the final power analysis. Flow sheet analysis and techno-economic analysis (TEA) was carried out to determine a lower power solution versus the baseline case. The original project scope suggested that the fiber sorbent PSA could be used to debottleneck a cryogenic air separation plant (cryo-ASU) with the combined plant having lower power than a standalone cryo-ASU. However, early flowsheet analysis showed that the PSA/cryo-ASU concept would not lead to a lower power solution. However, further flowsheet analysis suggested that an oxygen PSA combined with a nitrogen PSA could have lower power versus state-of-the-art air separation technology. Work concluded with the TEA showing a fiber sorbent oxygen PSA combined with an advanced nitrogen PSA could be up to 8% lower power versus the base case cryo-ASU. Overall, there is significant potential remaining for the zeolite hollow fiber sorbent concept, and this project successfully identified -- and ultimately remedied -- many technical challenges associated with scale-up.

01 COAL, LIGNITE, AND PEAT↗

Robust Molecular Predictive Methods for Novel Polymer Discovery and Applications

Polymeric materials are ubiquitous in modern society and they play an instrumental role in almost all industries, undoubtedly including the energy and environment sectors. Increased demand of energy and awareness to sustainability both necessitates the development of novel polymers with enhanced properties. Unfortunately, their structural and behavioral complexity render such discovery challenging and impeded. To address this problem, scientists are developing various computational modeling techniques and leveraging their power to depict the relationship between structural characteristics of polymers and their properties (such as rheological behaviors), and use such prediction to guide the design and syntheses of novel polymeric materials with enhanced performances. Unfortunately, predicting the relationships between polymer structure and composition with rheological properties via atomistic modeling is still a major challenge because of the extended time and length scales involved. Studying dynamic shear viscosity and linear viscoelasticity using molecular models requires capabilities that have been elusive, including representation of large molecular weight chains with an effective internal scale capable of describing entanglement, shear-rates that are in the s-1 scale with accurate quantitative stresses, and chemically-realistic combinations of both homogeneous and heterogeneous systems. Motivated by these unmet challenges, the overall technical objective of this DOE-STTR Phase II project is to develop robust molecular predictive methods for advanced polymer discovery and applications and especially for designing and demonstrating the “smart” polymer-based waterflooding enhanced oil recovery (EOR) process. In particular, we apply state-of-the-art molecular modeling methods developed by our academic partner, Materials Stimulation Center (MSC) at California Institute of Technology (Caltech), to facilitate and accelerate the experimental discovery processes. During the Phase I of this project, we had focused on development and demonstration of the molecular modeling methods to describe rheological properties of non-Newtonian polymer fluids, and to improve our fundamental understandings of shear-thickening mechanism and kinetics. In Phase II, we further apply the theoretical models to guide our experimental programs to improve our design of smart rheology modifier (SRM) polymers and their optimization for EOR. Specifically, we have three objectives in the Phase II study: (1) to further improve out computational modeling methods, coupling with the advanced machine learning algorithms; (2) to develop cost-effective and efficient SRM-flooding process suitable for EOR applications under typical reservoir conditions; and (3) to further explore the application of our molecular predictive models for innovative material discovery in other industrial applications. The recent development of our multiscale predictive framework allows the successful prediction of rheological properties from the chemical structure for polymers of experimentally relevant molecular weights, and provides an in-silico machine learning engine for screening novel compositions and structures with optimized non-Newtonian response, required for both shear-thinning and shear-thickening applications. Our framework provides: (1) procedures and tools for systematic coarsening from atomistic models and reverse mapping of coarse-grain models to atomistic, (2) unique ab initio methods to characterize the atomistic origin of colloidal and interfacial interactions and phenomena, (3) systematic structure and composition builders based on practical descriptors that drive rheological changes in polymer melts and diluted polymer mixtures, (4) a rheological properties engine capable of predicting viscosity in the zero-shear limit and under realistic dynamic conditions (for shear-rates commensurate with experiments) for large heterogeneous systems, (5) coarse-grain force fields with improved non-bond descriptions based on accurate quantum mechanics, (6) an in-silico screening machine learning engine that feeds from the systematic model builders to cover the descriptors search space, computes the rheological properties from converged trajectories spanning sub-milliseconds and ranks them for each structure/composition using an automated viscosity-vs-shear rate fitness function that can be tuned for shear-thickening, shear-thinning and other rheological responses.

02 PETROLEUM↗

Decarbonization During Predevelopment of Modular Building Solutions

Off-site construction methods offer the opportunity to compress costs of net-zero energy (NZE) housing using the advantages of mass production. There has been limited investigation on trade-offs between site-built and industrialized construction from the perspective of reducing the incremental cost of NZE strategies and reducing greenhouse gas emissions during embodied and operational stages. Blokable, LLC, a vertically integrated modular builder, wanted to know how the learning curves of mass production would help them decarbonize their existing modular housing prototype at a relative cost advantage. The method developed for this question looked at the life cycle assessment of an individual apartment and used learning-curve efficiencies to approximate the relative advantage of construction-at-scale. Greenhouse gas emissions were quantified by a learning-affected, whole-life carbon emissions model and demonstrated a path to a 60% reduction of whole-life CO2-equivalent in the 2030 production year. The resultant roadmap considers a best-first approach to decarbonizing a modular building product line, and the method can be replicated for other modular builders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Energy Efficiency Design Guide for Tribal Lands

Homeowners and renters on tribal lands have historically faced a disproportionate energy burden compared to the United States as a whole. The Indian Health Service (IHS), which serves these communities, strives to meet aggressive energy performance goals when constructing their residential housing. Challenges common in rural locations can hinder progress toward those goals, such as availability of materials, access to specialized labor, and budget constraints. This guide is for architects and builders who aim to incorporate energy efficiency (EE) into their residential designs. This report presents commercially viable energy efficiency packages for a variety of locations and home inputs to help guide home builders in choosing improvements for energy performance. The intention is to provide a diverse set of packages that can be used during the design phase to achieve energy savings compared to a code minimum building design. By presenting a set of diverse options with similar expected energy savings and life-cycle costs, final decisions can be left up to the building designers who can better determine the appropriate package given local costs, materials, and labor availability. Although this guide was developed for IHS projects, it can be used to help designers and construction professionals better make cost-effective choices when a detailed, project-specific building energy analysis is not possible.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Incentivizing Cold-Climate Efficiency in Juneau (Final Report)

This is the final technical report for the DOE EERE BTO project Incentivizing Cold-Climate Efficiency in Juneau. The project implemented a community energy campaign to deploy heat pumps and efficiency for residents of Juneau, in Southeast Alaska. The project helped Juneau make progress towards its renewable energy goal of reaching 80% renewable energy for space heating by 2045. The Incentivizing Cold-Climate Efficiency in Juneau (ICE-Juneau) project began in 2020 and concluded three years later in 2023. During that time, a group of implementation partners and a research advisory team instituted a beneficial electrification campaign to promote energy savings and carbon reduction in residences of Juneau, Alaska. The campaign, Thermalize Juneau, focused on the installation of single head ductless mini-split heat pumps along with other efficiency upgrades. Thermalize Juneau was the first campaign of its kind in Alaska. After several months of planning, registration opened to the public in early 2021, and over the course of six months 164 participants enrolled. Campaign staff provided education to homeowners on heat pumps and efficiency, and each participant received a one-on-one heat pump assessment using a custom Microsoft Excel-based calculator that estimated energy savings for their residence based on building characteristics and past utility bills. Participants could also obtain a free energy audit from one of the two local energy auditors to further inform their decision. A heat pump installer, electrician, and builder were selected via a competitive RFP process. Participants who felt ready to install a heat pump or other efficiency upgrades received a site visit and custom quote from each of these contractors free of charge, and if they still felt energy upgrades were right for them, could move forward with an individual contract. Participants received a $400 heat pump installation rebate, offered by the installer if 40 heat pump installations occurred through the campaign. Overall, the campaign facilitated 75 heat pump installations (including participants that went with another contractor or heat pump model) and 30 efficiency upgrades (including participants that went with another builder or did DIY upgrades). The campaign created 3 new jobs as the heat pump installer hired an administrative assistant and two apprentices over the course of the campaign. It also helped Juneau work toward achieving its renewable energy goal of 80% renewable energy for space heating by 2045 by upgrading houses from fuel oil to heat pumps powered by the hydropower electric grid. Researchers conducted four surveys to inform Thermalize Juneau and future energy campaigns. The first surveyed existing and prospective heat pump owners in Juneau to identify barriers the campaign could address and inform recruitment efforts. Entry and exit surveys provided information on participant demographics, goals, outcomes, and suggestions for improving future campaigns. And a final survey of community members who had not participated in Thermalize Juneau gave insight on ways future campaigns could include a greater diversity of participants so they could realize similar benefits. Researchers also used pre-campaign energy modeling to predict energy savings, which was then compared to the savings estimated through aggregation of heat pump assessments and energy audits, and later to actual energy savings of 10 participants who installed a heat pump and were able to provide complete energy use data sets. In addition to energy savings, and to assist the electric utility in future planning efforts, researchers analyzed the overall change in electric use across participants with energy data and heat pump installations. They also completed a life cycle cost analysis, showing positive net present values for those displacing a fuel oil appliance, and a more mixed case for those switching from electric baseboard. This project proved the feasibility of energy campaigns, with a goal of beneficial electrification, in cold, remote locations. The Thermalize Juneau team compiled a Guidebook to Thermalize Campaigns, available online. In addition to documenting what occurred in Alaska’s first thermalize campaign, it provides tips and resources for other communities wishing to implement a similar program.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

DFTT report for Signal Analysis (2023)

The Detection Framework Testbed and Toolkit (DFTT) is a database and associated java programs intended to facilitate the development and testing of algorithms for operating suites of correlation and subspace detectors. This framework is a generalization of the system described in Harris and Dodge (2011) and Dodge and Harris (2016). DFTT allows retrospective processing of sequences of data using various system configurations. Results are saved in a database, so it is easy to compare the results obtained using different configurations of the system. The principal software components of DFTT are the ConfigCreator, the framework_runner and the Builder program. ConfigCreator assembles the files necessary to define a particular configuration used for processing. The framework_runner operates suites of detectors and saves the results in an Oracle™ database. Builder allows visual examination of templates and detected signals and allows editing and creation of detectors. In addition, there are tools for importing continuous data into the database. DFTT is licensed under the MIT license and has LLNL release number LLNL-CODE-801881. In the current fiscal year DFTT has been used in two different projects. The first (NTL-funded) project investigates the feasibility of screening nuisance detections using correlation detectors. The second (GNEM-funded) project seeks to extend the results of Harris and Dodge (2021) to 3- D sources and multiple stations. Each of these efforts required that additional functionality be added to DFTT. In this report I will summarize the enhancements to DFTT in the context of the relevant research effort.

58 GEOSCIENCES↗

Advanced HVAC Humidity Control for Hot-Humid Climates

During this project we develop and validate a cost-effective, integrated control solution to improve humidity control and comfort for energy-efficient homes in hot-humid climates. This study focuses on developing a strategy that is effective, field tested, and practical for builders to install with minimal disruption to standard practices. A successful solution would simplify the transition to high-performance humidity control and be the basis for design and installation guidance. By relying on the central system as a starting point, the strategy employed minimizes system complexity and cost for builders, while improving comfort and operating cost for homeowners. The solution strategy was to coordinate the cooling, dehumidification, and ventilation functions of central, ducted HVAC systems to better control indoor humidity, improve occupant thermal comfort, and capture energy savings. The primary strategic goals were to: (1) optimize dehumidification by the central air-conditioning system, particularly during part-load conditions, using conventional equipment with modified control settings and lower system airflows; (2) maximize ventilation during heating/cooling on-cycles, to “bank” and condition outdoor ventilation air, and minimize ventilation during off-cycles; (3) quantify the effectiveness and energy impact of the dehumidification and ventilation strategies, while identifying a metric that would be useful to evaluate latent effectiveness. For the test houses in our study, located in Richmond Hill, Georgia; Houston, Texas; and Monroe, Louisiana we observed: (1) the indoor humidity did not exceed 60% RH during the monitored cooling season for 99% of the time in Richmond Hill, 96% of the time in Houston, and 90% of the time in Monroe; (2) the dehumidification strategy improved the steady-state latent capacity of the HVAC system at design conditions by 16% to 49% at the Houston test house and by 28% to 71% at the Monroe test house, depending on which mode the system was operating in; and (3) the good results at the test houses were primarily due to the amount of time the air-conditioning system operated in ramping or dehumidification modes, or both, particularly during the early cooling season. This study demonstrates that air conditioners or heat pumps with a single-stage compressor can provide good humidity control without the need for a two-stage or variable-stage compressor system. The airflow and control settings for ramping and dehumidification modes are critical to control indoor humidity in hot-humid climates, particularly during part-load and shoulder season conditions. The dehumidification strategy used in this study did not jeopardize the mechanical reliability of the cooling equipment. The strategies used in this study are applicable across various equipment brands, models, and efficiency levels, and also applicable to a broad range of homes in hot-humid climates. Results will vary by specific equipment, location, and house configuration and construction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Performance and Costs of Ductless Heat Pumps in Marine-Climate High-Performance Homes Habitat for Humanity The Woods

The Washington State University (WSU) Energy Program's Building America (BA) team conducted a case study of a high-performance affordable housing community: The Woods (Figure 1). This BA effort is part of a larger-scale study of 30 homes funded from 2013-2016 by Tacoma Public Utilities (TPU) and the Bonneville Power Administration. The Woods is a Habitat for Humanity (HFH) community of homes certified by ENERGY STAR Homes Northwest (ESHNW); the community is in the marine climate of Tacoma/Pierce County, Washington. This research report builds on an earlier preliminary draft 2014 BA report and includes significant billing analysis and cost-effectiveness research from a collaborative and ongoing DHP research effort for TPU and the Bonneville Power Administration. This final BA report focuses on the results of field testing, modeling, and monitoring of ductless mini-split heat pump hybrid heating systems in seven homes built and first occupied at various times between September 2013 and October 2014. The report also provides WSU documentation of high-performance home observations, lessons learned, and stakeholder recommendations for builders of affordable high-performance housing. The research goal of the U.S. Department of Energy's BA research team Building America Partnership for Improved Residential Construction was to compare a ductless heat pump (DHP) hybrid system (DHP in common area/electric resistance [ER] in bedrooms) to an all-electric zonal ER system in high-performance single-family affordable housing. This effort included assessing the costs and benefits of a DHP/ER hybrid system located in the main living area to offset the primary heating demand of zonal ER heaters in the bedroom zones and comparing these findings to data from of new affordable single-family housing in Washington State. This report includes: (1) Measured indoor and outdoor temperatures and relative humidity (RH) in the homes. (2) Field testing results of heating, ventilating, and air-conditioning equipment; ventilation system airflows; building envelope tightness; lighting, appliance, and other input data required for preliminary Building Energy Optimization (BEopt) modeling; and ENERGY STAR field verification (3) BEopt modeling results compared to measured energy use. (4) A comparison of the space heat energy consumption of a DHP/ER hybrid heating system and a traditional zonal ER heating system installed in the same home. This comparison is made by implementing a series of weekly "flip-flop tests" (referred to here as "switchback" tests per TPU) to compare space heating, temperature, and RH in zonal ER heating mode with a DHP/ER mode as discussed in the Building America Test Plan (Lubliner 2010a). (5) Cost data from HFH and other sources related to building efficiency measures focusing on the DHP/ER hybrid heating system. (6) An evaluation of the thermal performance and cost benefit of DHP/ER hybrid heating systems in these high-performance homes employing life cycle cost analysis for energy code policy and monthly cash flow analysis of HFH homeowners. (7) Post-monitoring occupant survey results. The report also provides the following stakeholder findings and recommendations: (1) DHP single-head systems at The Woods are cost-effective to new homebuyers of these high-performance all-electric homes. (2) Stakeholder education is needed on design, inspection, and commissioning; documentation is needed for heat recovery ventilation (HRV) and from ENERGY STAR builders, verifiers, and inspectors to help ensure that the houses meet the goal of "build tight, ventilate right." (3) A code gap in inspection and enforcement was identified that should be addressed by: (3a) Improving the fire marshal's approach to sprinkler attic piping freeze protection; (3b) Improving the maintenance of ceiling insulation continuity; and (3c) Educating the local building inspector on attic insulation inspection concerns that allow for maximizing design improveme...

affordable housing↗