Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “binary instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Photometric and Spectroscopic Analysis of Four Contact Binaries

We present the photometric and spectroscopic analysis of four W UMa binaries J015829.5+260333 (hereinafter as J0158), J030505.1+293443 (hereinafter as J0305), J102211.7+310022 (hereinafter as J1022), and KW Psc. The VR {sub c} I {sub c} band photometric observations are carried out with the 1.3 m Devasthal Fast Optical Telescope (DFOT). For low-resolution spectroscopy, we used the 2 m Himalayan Chandra Telescope (HCT) as well as the archival data from the 4 m LAMOST survey. The systems J0158 and J0305 show a period increase rate of 5.26( ± 1.72) × 10{sup −7} days yr{sup −1} and 1.78( ± 1.52) × 10{sup −6} days yr{sup −1}, respectively. The period of J1022 is found to be decreasing with a rate of 4.22 ( ± 1.67) × 10{sup −6} days yr{sup −1}. The period analysis of KW Psc displays no change in its period. The PHOEBE package is used for the light-curve modeling and basic parameters are evaluated with the help of the GAIA parallax. The asymmetry of light curves is explained with the assumption of cool spots at specific positions on one of the components of the system. On the basis of temperatures, mass ratios, fill-out factors, and periods, the system J1022 is identified as a W-subtype system while the others show some mixed properties. To probe the chromospheric activities in these W UMa binaries, their spectra are compared with the known inactive stars’ spectra. The comparison shows emission in H {sub α}, H {sub β}, and Ca II. To understand the evolutionary status of these systems, the components are plotted in mass–radius and mass–luminosity planes with other well characterized binary systems. The secondary components of all the systems are away from ZAMS, which indicates that the secondary is more evolved than the primary component.

47 OTHER INSTRUMENTATION↗

Faint X-ray binaries and their optical counterparts in M31

X-ray binaries (XRBs) are probes of both star formation and stellar mass, but more importantly remain one of the only direct tracers of the compact object population. To investigate the XRB population in M31, we utilized all 121 publicly available observations of M31 totalling over 1 Ms from Chandra's ACIS instrument. We studied 83 star clusters in the bulge using the year 1 star cluster catalogue from the Panchromatic Hubble Andromeda Treasury Survey. We found 15 unique star clusters that matched to 17 X-ray point sources within 1'' (3.8 pc). This population is composed predominantly of globular cluster low-mass XRBs, with one previously unidentified star cluster X-ray source. Star clusters that were brighter and more compact preferentially hosted an X-ray source. Specifically, logistic regression showed that the F475W magnitude was the most important predictor followed by the effective radius, while color (F475W–F814W) was not statistically significant. We also completed a matching analysis of 1566 H II regions and found 10 unique matches to 9 X-ray point sources within 3'' (11 pc). The H II regions hosting X-ray point sources were on average more compact than unmatched H II regions, but logistic regression concluded that neither the radius nor Hα luminosity was a significant predictor. Four matches have no previous classification and thus are high-mass XRB candidates. A stacking analysis of both star clusters and H II regions resulted in non-detections, giving typical upper limits of ≈10{sup 32} erg s{sup –1}, which probes the quiescent XRB regime.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray variability observed with HEAO A-1

Results from the HEAO A-1 instrument which observed X-ray source variability over a wide range of accessible timescales are surveyed. The objects observed include quasars, BL Lacertae, and active galactic nuclei. A high sensitivity search for X-ray pulsars, known black hole candidates, period fluctuation in binary pulsars, and X-ray and gamma ray bursts are among the topics covered.

Friedman, H.↗

Fermi GBM: Highlights from the First Year

The Fermi Gamma ray Burst Monitor is an all-sky instrument sensitive to photons from about 8 keV to 40 MeV. I will summarize highlights from the first year, including triggered observations of gamma ray bursts, soft gamma ray repeaters, and terrestrial gamma flashes, and observations in the continuous data of X-ray binaries and accreting X-ray pulsars. GBM provides complementary observations to Swift/BAT, observing many of the same sources, but over a wider energy range.

Wilson-Hodge, Colleen A.↗

Tiros IV Radiation Data Catalog and Users' Manual

The TIROS IV Meteorological Satellite contains a medium resolution scanning radiometer. Two of the channels of this instrument are sensitive to reflected solar radiation and the remaining two respond to emitted thermal radiation from the earth and its atmosphere. The two thermal channels are calibrated in terms of equivalent blackbody temperatures, and the reflected solar radiation channels in terms of effective radiant emittances. The calibration data, along with orbital and attitude data and the radiation data from the satellite, were incorporated in a computer program for an IBM 7090 which was used to produce, in binary form, the "Final Meteorological Radiation Tape" which is the basic repository of all radiation data. After launch, the radiometer displaye d the same degradation of response characteristics as did its predecessors in TIROS II and TIROS III. The onset of degradation results in a departure of the data from the prelaunch laboratory calibration. The cause of degradation has not been determined, and the matter is still being studied at the Goddard Space Flight Center. Before work with the TIROS IV radiation data is attempted, an understanding of the radiometer, its calibration, and the problems encountered in the experiment, especially from response degradation, is essential. The instrumentation design, development work, and the calibrations herein described were performed by the Goddard Space Flight Center Staff, whereas the computer and programming efforts were carried out jointly by the staffs of the National Weather Satellite Center, U. S. Weather Bureau, and the Goddard Space Flight Center. In this Catalog-Manual, the radiometer an d its calibration, data processing, the "Final Meteorological Radiation Tape", the observed degradation patterns, and possible corrections for degradation are discussed. The Catalog-Manual also includes, in two forms, documentation of each orbit of successfully reduced radiation data acquired by TIROS IV. One method of presentation is the Index of Final Meteorological Radiation Tapes and the other is a Subpoint Track, Summary of Available Radiation Data in diagrammatic form.

TIROS IV SATELLITE↗

β Cephei Pulsations in the High-mass Eclipsing System CW Cephei

CW Cep is an early B-type eclipsing binary with mass measurement precisions better than 1%. We report the discovery of pulsation signatures in the Transiting Exoplanet Survey Satellite time-series data of the system observed during Sectors 17 and 18. Our binary modeling indicates that the target star is a partially eclipsing detached system with masses of 12.95 M {sub ⊙} and 11.88 M {sub ⊙} and radii of 5.52 R {sub ⊙} and 5.09 R {sub ⊙} in an eccentric orbit of e = 0.0305. The distance to the eclipsing system, 928 ± 36 pc, is much more precise than the Gaia distance of 962 ± 453 pc. Applying multifrequency analyses to the residual light curve in the outside-eclipse part, we detected 13 significant signals in two frequency regions. Six frequencies below 1 day{sup −1} appeared to be mostly orbital harmonic and combination terms, or sidelobes due to insufficient removal of the binary effects. In contrast, seven frequencies clustered around 2.73 day{sup −1} and 5.34 day{sup −1} could be considered β Cep–type pulsations. Our results represent the second discovery of β Cep pulsations present in double-lined eclipsing binaries with precise masses and, hence, CW Cep serves as an important test bed for the asteroseismic modeling of high-mass stars.

47 OTHER INSTRUMENTATION↗

Cygnus X-1: A Case for a Magnetic Accretion Disk?

With the advent of Rossi X-ray Timing Explorer (RXTE), which is capable of broad spectral coverage and fast timing, as well as other instruments which are increasingly being used in multi-wavelength campaigns (via both space-based and ground-based observations), we must demand more of our theoretical models. No current model mimics all facets of a system as complex as an x-ray binary. However, a modern theory should qualitatively reproduce - or at the very least not fundamentally disagree with - all of Cygnus X-l's most basic average properties: energy spectrum (viewed within a broader framework of black hole candidate spectral behavior), power spectrum (PSD), and time delays and coherence between variability in different energy bands. Below we discuss each of these basic properties in turn, and we assess the health of one of the currently popular theories: Comptonization of photons from a cold disk. We find that the data pose substantial challenges for this theory, as well as all other in currently discussed models.

Nowak, Michael A.↗

Results from the CBC3 readout ASIC for CMS 2S-modules

The CBC3 is the latest version of the CMS Binary Chip for readout of the outer radial region of the upgraded CMS Tracker at the High Luminosity LHC. This 254-channel, 130 nm CMOS ASIC is designed to be bump-bonded to a substrate to which sensors will be wire-bonded. It will instrument double-layer 2S-modules, containing two overlaid silicon microstrip sensors, aligned with a parallel orientation. On-chip logic identifies Level-1 trigger primitives from high transverse-momentum tracks by selecting correlated clusters in the two sensors. The CBC3 was delivered in late 2016; wafer probing and performance tests have been carried out. Several prototype modules using the CBC3 have been produced and tested in the lab and in different beams. The results show that the CBC3 satisfies CMS requirements and only small corrections are needed for the final version of the chip for production.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Illinois occultation summary, 1. 1977 - 1978

Instrumentation and data acquisition techniques used to record lunar occultations at the University of Illinois Prairie Observatory are described. Tables and graphs summarize data from 64 events which include 30 observations of stars brighter than 7th magnitude, 40 reappearances, 4 angular diameter measurements, 8 observations of binary stars, and 6 observations which may indicate multiplicity.

Radick, R.↗

The Stars Kepler Missed: Investigating the Kepler Target Selection Function Using Gaia DR2

The Kepler Mission revolutionized exoplanet science and stellar astrophysics by obtaining highly precise photometry of over 200,000 stars over 4 yr. A critical piece of information to exploit Kepler data is its selection function, since all targets had to be selected from a sample of half a million stars on the Kepler CCDs using limited information. Here we use Gaia DR2 to reconstruct the Kepler selection function and explore possible biases with respect to evolutionary state, stellar multiplicity, and kinematics. We find that the Kepler target selection is nearly complete for stars brighter than Kp < 14 mag and was effective at selecting main-sequence stars, with the fraction of observed stars decreasing from 95% to 60% between 14 < Kp < 16 mag. We find that the observed fraction for subgiant stars is only 10% lower, confirming that a significant number of subgiants selected for observation were believed to be main-sequence stars. Conversely we find a strong selection bias against low-luminosity red giant stars (R ≈ 3–5R {sub ⊙}, T {sub eff} ≈ 5500 K), dropping from 90% at Kp = 14 mag to below 30% at Kp = 16 mag, confirming that the target selection was efficient at distinguishing dwarfs from giants. We compare the Gaia Re-normalized Unit Weight Error (RUWE) values of the observed and nonobserved main-sequence stars and find a difference in elevated (>1.2) RUWE values at ∼σ significance, suggesting that the Kepler target selection shows some bias against either close or wide binaries. We furthermore use the Gaia proper motions to show that the Kepler selection function was unbiased with respect to kinematics.

47 OTHER INSTRUMENTATION↗

ROSAT/Chandra Observations of a Bright Transient in M81

We present a 10-year X-ray light curve and the spectra of a peculiar X-ray transient in the spiral galaxy M81. The source was below the detection limit of ROSAT PSPC before 1993, but it brightened substantially in 1993, with luminosities exceeding the Eddington limit of a 1.5 solar mass compact accretor. It then faded and was not firmly detected in the ROSAT HRI and PSPC observations after 1994. The Chandra image obtained in 2000 May, however, shows an X-ray source at its position within the instrumental uncertainties. The Chandra source is coincident with a star-like object in the Digitized-Sky-Survey. A Hubble image suggests that the optical object may be extended. While these three observations could be of the same object, which may be an X-ray binary containing a black-hole candidate, the possibility that the ROSAT and Chandra sources are two different objects in a dense stellar environment cannot be ruled out. The Hubble data suggests that the optical object may be a globular cluster yet to be identified.

Ghosh, Kajal K.↗

Spitzer Infrared Spectrograph Observations of L, M, and T Dwarfs

We present here the first mid-infriared spectra of brown dwarfs, together with observations of a low-mass star. Our targets are the M3.5 dwarf GJ 1001 A, the L8 dwarf DENIS-P JO255-4700, and the T1/T6 binary system epsilon Indi Ba/Bb. As expected, the mid- infrared spectral morphology of these objects changes rapidly with spectral class due to the changes in atmospheric chemistry resulting from their differing effective temperatures and atmospheric structures. By taking advantage of the unprecedented sensitivity of the Infrared Spectrograph instrument of the Spitzer Space Telescope we have detected for the first time the 7.6 micron methane band and confirmed the presence of ammonia in a T dwarf atmosphere.

Roellig, Thomas L.↗

GRO J1655-40: Early Stages of the 2005 Outburst

The black-hole X-ray binary transient GRO J1655-40 underwent an outburst beginning in early 2005. We present the results of our multi-wavelength observational campaign to study the early outburst spectral and temporal evolution, which combines data from X-ray (RXTE, INTEGRAL), radio (VLA) and optical (ROTSE, SMARTS) instruments. During the reported period the source left quiescence and went through four major accreting black hole states: low-hard, hard intermediate, soft intermediate and high-soft. We investigated dipping behavior in the RXTE band and compare our results to the 1996-1997 case, when the source was predominantly in the high-soft state, finding significant differences. We consider the evolution of the low frequency quasi-periodic oscillations and find that the frequency strongly correlates with the spectral characteristics, before shutting off prior to the transition to the high-soft state. We model the broad-band high-energy spectrum in the context of empirical models, as well as more physically motivated thermal and bulk-motion Comptonization and Compton reflection models. RXTE and INTEGRAL data together support a statistically significant high energy cut-off in the energy spectrum at approximately equal to 100 - 200 keV during the low-hard state. The RXTE data alone also show it very significantly during the transition, but cannot see one in the high-soft state spectra. We consider radio, optical and X-ray connections in the context of possible synchrotron and synchrotron self-Compton origins of X-ray emission in low-hard and intermediate states. In this outburst of GRO J1655-40, the radio flux does not rise strongly with the X-ray flux.

Shaposhnikov, N.↗

Interstellar Abundances Toward X Per, Revisited

The nearby X-ray binary X Per (HD 24534) provides a useful beacon with which to measure elemental abundances in the local ISM. We examine absorption features of O, Mg, and Si along this line of sight using spectra from the Chandra Observatory's LETG/ACIS-S and XMM-Newton's RGS instruments. In general, we find that the abundances and their ratios are similar to those of young F and G stars and the most recent solar values. We compare our results with abundances required by dust grain models.

Valencic, Lynne A.↗

THE EVOLVED MAIN-SEQUENCE CHANNEL: HST AND LBT OBSERVATIONS OF CSS 120422:111127+571239

The “evolved main-sequence (EMS)” channel is thought to contribute significantly to the population of AM CVn-type systems in the Galaxy, and also to the number of cataclysmic variables (CVs) detected below the period minimum for hydrogen rich systems. CSS 120422:J111127+571239 was discovered by the Catalina Sky Survey in 2012 April. Its period was found to be 56 minutes, well below the minimum, and the optical spectrum is clearly depleted in hydrogen relative to helium, but still has two orders of magnitude more hydrogen than AM CVn stars. Doppler tomography of the Hα line hinted at a spiral structure existing in the disk. Here we present spectroscopy of CSS 120422:J111127+571239 using the Cosmic Origins Spectrograph FUV instrument on the Hubble Space Telescope and using the MODS spectrograph on the Large Binocular Telescope. The UV spectrum shows Si iv, N v, and He ii, but no detectable C iv. The anomalous nitrogen/carbon ratio is seen in a small number of other CVs and confirms a unique binary evolution. We also present and compare the optical spectrum of V418 Ser and advocate that it is also an EMS system.

79 ASTRONOMY AND ASTROPHYSICS↗

CLOUD STRUCTURE OF THE NEAREST BROWN DWARFS: SPECTROSCOPIC VARIABILITY OF LUHMAN 16AB FROM THE HUBBLE SPACE TELESCOPE

The binary brown dwarf WISE J104915.57–531906.1 (also Luhman 16AB), composed of a late-L and early-T dwarf, is a prototypical L/T transition flux reversal binary located at a distance of only 2 pc. Luhman 16B is a known variable whose light curves evolve rapidly. We present a spatially resolved spectroscopic time-series of Luhman 16A and B covering 6.5 hr using the Hubble Space Telescope/WFC3 at 1.1-1.66 μm. The small, count-dependent variability of Luhman 16A at the beginning of the observations likely stems from instrumental systematics; Luhman 16A appears non-variable above ≈0.4%. Its spectrum is well fit by a single cloud layer with intermediate cloud thickness (f {sub sed} = 2, T {sub eff} = 1200 K). Luhman 16B varies at all wavelengths with peak-to-valley amplitudes of 7%-11%. The amplitude and light curve shape changes over only one rotation period. The lowest relative amplitude is found in the deep water absorption band at 1.4 μm, otherwise it mostly decreases gradually from the blue to the red edge of the spectrum. This is very similar to the other two known highly variable early-T dwarfs. A two-component cloud model accounts for most of the variability, although small deviations are seen in the water absorption band. We fit the mean spectrum and relative amplitudes with a linear combination of two models of a warm, thinner cloud (T {sub eff} = 1300 K, f {sub sed} = 3) and a cooler, thicker cloud (T {sub eff} = 1000-1100 K, f {sub sed} = 1), assuming out-of-equilibrium atmospheric chemistry. A model with parameters as for Luhman 16A except for the addition of cloud holes cannot reproduce the variability of Luhman 16B, indicating more complex cloud evolution through the L/T transition. The projected separation of the binary has decreased by ≈0.''3 in eight months.

79 ASTRONOMY AND ASTROPHYSICS↗

mzPeak: Designing a Scalable, Interoperable, and Future-Ready Mass Spectrometry Data Format

Advances in mass spectrometry (MS) instrumentation, such as higher resolution, faster scan speeds, and improved sensitivity, have significantly increased the volume and complexity of data. The growing adoption of imaging and ion mobility further amplifies these challenges across MS-based omics fields, including proteomics, metabolomics, and lipidomics. While these technologies unlock new possibilities, they also present significant challenges in data management, storage, and accessibility. Existing open formats, such as the XML-based community standards mzML and imzML, struggle to meet the demands of modern MS workflows due to their large file sizes, slow data access, and limited metadata support. Vendor-specific formats, while optimized for proprietary instruments, lack interoperability, comprehensive metadata support and long-term archival reliability. This white paper lays the groundwork for mzPeak, a next-generation community data format designed to address these challenges and support high-throughput, multi-dimensional MS workflows. By adopting a hybrid model that combines efficient binary storage for numerical data and both human and machine-readable metadata storage, mzPeak will reduce file sizes, accelerate data access, and offer a scalable, adaptable solution for evolving MS technologies. For researchers, mzPeak will enable enhanced interoperability across platforms, seamless support for complex workflows including ion mobility and MS imaging, and faster data access compared to existing community formats such as mzML. Its design will ensure data is managed in compliance with regulatory standards, essential for applications such as precision medicine and chemical safety, where long-term data integrity and accessibility are critical. For vendors, mzPeak provides a streamlined, open alternative to proprietary formats, reducing the burden of regulatory compliance while aligning with the industry's push for transparency and standardization. By offering a high-performance, interoperable solution, mzPeak positions vendors to meet customer demands for sustainable data management tools which will be able to handle emerging and future data types and workflows. mzPeak aspires to become the cornerstone of MS data management, empowering researchers, vendors, and developers to innovate and collaborate more effectively.

data formats↗

All-sky Medium Energy Gamma-ray Observatory eXplorer mission concept

The All-sky Medium Energy Gamma-ray Observatory eXplorer (AMEGO-X) is designed to identify and characterize gamma rays from extreme explosions and accelerators. The main science themes include supermassive black holes and their connections to neutrinos and cosmic rays; binary neutron star mergers and the relativistic jets they produce; cosmic ray particle acceleration sources including galactic supernovae; continuous monitoring of other astrophysical events and sources over the full sky in this important energy range. AMEGO-X will probe the medium energy gamma-ray band using a single instrument with sensitivity up to an order of magnitude greater than previous telescopes in the energy range 100 keV to 1 GeV that can be only realized in space. Finally, during its 3-year baseline mission, AMEGO-X will observe nearly the entire sky every two orbits, building up a sensitive all-sky map of gamma-ray sources and emissions. AMEGO-X was submitted in the recent 2021 NASA MIDEX announcement of opportunity.

79 ASTRONOMY AND ASTROPHYSICS↗