Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “baseline program”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Time calibration and synchronization of the scintillation light detection system in ICARUS-T600

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently used as a far detector of the Short Baseline Neutrino (SBN) program at Fermilab (USA) to search for a possible LSND-like sterile neutrino signal at $\Delta m^2 \approx 1 eV^2$ with the Booster Neutrino Beam (BNB). A light detection system, based on 360 large area Photo-Multiplier Tubes (PMTs), has been realized for ICARUS-T600 to detect VUV photons produced after the passage of ionizing particles in LAr. This system is fundamental for the TPC operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the detector is exposed to a huge flux of cosmic rays due to its shallow depths operations, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of neutrino interactions within the BNB spill gate. The correct time reconstruction of events requires the precise knowledge of the delay of each PMT channel and a good synchronization of recording electronics, this last based on fast sampling digitizers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Data analysis in the ICARUS (SBN FD) Cosmic Ray Tagging system

When a cosmic ray particle collides with the upper atmosphere, it creates a shower of particles that transverse down to the Earth’s surface. These cosmogenic particles provide a challenging background in neutrino experiments. The Short Baseline Neutrino (SBN) Program is composed of three Liquid Argon Time Projection Chambers (LArTPCs) that will help us understand the elusive neutrino. Together with a Cosmic Ray Tagger (CRT) system, the ICARUS detector serves as the Far Detector in the SBN Program. The CRT surrounds the detector medium and tags incoming particles allowing us to combat the high flux of comic rays we experience at ICARUS. In this poster, I will show some of the first data analyses done with the fully commissioned CRT system, including studies using CRT timing information and CRT hit reconstruction.

43 PARTICLE ACCELERATORS↗

Gain Stability of Hamamatsu R5912-MOD Photo-Multipliers at Low Temperature

The Photon Detection System is a crucial component of the ICARUS detector in the Short Baseline Neutrino (SBN) Program at Fermi National Accelerator Laboratory (FNAL). It consists of 360 Photo Multiplier Tubes (PMTs) 8” Hamamatsu R5912-MOD and, since June 2020, it has been operated at the liquid Argon cryogenic temperature. During these years, the PMTs have shown gain losses as an aging effect. Using a climatic chamber at the INFN Sezione di Catania, we confirmed a stable gain for a single PMT 8” Hamamatsu 5912-MOD when operated at room temperature, and a persistent gain loss at temperatures around -70°C, although far from the liquid Argon one. No gain recovery was obtained bringing the PMT back to room temperature. We suspect that dynode deterioration due to temperature gradient plays a significant role in this phenomenon. During our test, the PMT was illuminated by a 520 nm laser source and operated in current mode. The laser beam was split into two optical fibers, the first one transmitting light through Neutral Density filters and then diffusing it over the surface of the PMT photocathode. The other optical fiber was used for an independent reference measurement of the injected light via a bolometric photodetector. In this presentation, the main technical characteristics of the measurement system are shown together with preliminary results which need further investigation to elucidate the underlying mechanisms driving the gain loss and to propose new mitigation strategies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Double-differential Measurements of Mesonless Charged-current Muon Neutrino Interactions on Argon with Final-State Protons using the MicroBooNE Detector

This note reports the first double-differential measurements of charged-current $ν_µ$ scattering on argon leading to final states containing zero mesons and one or more protons. This event topology (hereafter abbreviated as CC0$πNp$) is the most common at the neutrino energies typically produced by the Fermilab Booster Neutrino Beam. A detailed understanding of neutrino-argon scattering in the CC0$πNp$ channel is therefore crucial for the success of the precision neutrino oscillation analyses planned for the Short-Baseline Neutrino (SBN) program. This remains true for the upcoming Deep Underground Neutrino Experiment (DUNE), but the higher mean neutrino energy used there will ensure that more inelastic reaction modes, such as single pion production, will also play a major role. The analysis described in this note builds on a previous MicroBooNE study of the CC0$πNp$ channel which obtained the first single-differential cross-section measurements on an argon target. Since that foundational work, significant improvements have been made to MicroBooNE’s simulation software, event reconstruction algorithms, and procedure for calculating systematic uncertainties. When combined with a larger dataset (corresponding to a beam exposure of 6.79 × 10 20 protons-on-target versus 1.60 × 10 20 in Ref. [3]), these enhancements allow the important CC0$πNp$ channel to be studied in more detail. This note begins with a description of the data and simulation samples used as input to the analysis. Section 3 then defines the CC0$πNp$ signal event topology, and Section 4 describes a set of selection criteria designed to identify these events in MicroBooNE data. Binning schemes are then defined in Section 5 for two double-differential measurements of event rates. The first of these considers the momentum and scattering cosine of the outgoing muon, while the second reports the same observables for the leading proton, i.e., the final-state proton with the largest momentum. After a discussion of systematic uncertainties in Section 6, the note concludes by comparing the predictions of MicroBooNE Monte Carlo (MC) simulations to the measured double-differential distributions. These results will form the basis for a future extraction of flux-averaged double-differential CC0$πNp$ cross sections that will be immediately comparable to the theoretical predictions of multiple neutrino event generators. The selection described herein may also be used to study various other observables in CC0$πNp$ events, including those which are sensitive to correlations between leptonic and hadronic kinematics in the final state.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Measurements of Differential Cross Sections In Kinematic Imbalance Variables With The MicroBooNE Detector

Making high-precision measurements of neutrino oscillation parameters requires an unprecedented understanding of neutrino-nucleus scattering. In this presentation, we present the first muon neutrino charged current double-differential cross sections in kinematic imbalance variables. These variables characterize the imbalance in the plane transverse to an incoming neutrino. We use events with a single muon above 100 MeV/c, a single final state proton above 300 MeV/c, and no recorded final state pions. Thus, these variables act as a direct probe of nuclear effects such as final state interactions, Fermi motion, and multi-nucleon processes. We also present a complementary ongoing analysis using electron neutrinos. This channel is of the utmost importance for the extraction of neutrino oscillation parameters by making high-precision measurements. Our measurements allow us to constrain systematic uncertainties associated with neutrino oscillation results performed by near-future experiments of the Short Baseline Neutrino (SBN) program, as well as by future large-scale experiments like DUNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reconstruction of the BNB and NuMI Neutrino Bunch Structure with ICARUS

ICARUS serves as the Far Detector of the Short Baseline Neutrino (SBN) program at Fermilab, sitting on-axis on the Booster Neutrino Beam (BNB) and 6$^\circ$ off-axis from the Neutrinos at the Main Injector (NuMI) beam. Neutrinos from both beams inherit the timing sub-structure of their parent proton spills, which is in turn derived from either the Booster's or the Main Injector's synchrotron acceleration. Since neutrino propagation introduces only a constant offset, their timing structure is preserved as they travel. Identifying this structure in data represents a powerful tool for selecting neutrino events and searching for physics beyond the Standard Model (BSM). This poster presents the preliminary reconstruction of the BNB and NuMI neutrino bunch structure with ICARUS data, exploiting only the precise timing of ICARUS optical readout system to both locate and assign a time to each interaction.

43 PARTICLE ACCELERATORS↗

SBND In 10 Minutes

The Short-Baseline Near Detector (SBND) is one of three Liquid Argon Time Projection Chamber (LArTPC) neutrino detectors positioned along the axis of the Booster Neutrino Beam (BNB) at Fermilab, as part of the Short-Baseline Neutrino (SBN) Program. The detector is currently being commissioned and is expected to take neutrino data this year. SBND is characterized by superb imaging capabilities and will record over a million neutrino interactions per year. Thanks to its unique combination of measurement resolution and statistics, SBND will carry out a rich program of neutrino interaction measurements and novel searches for physics beyond the Standard Model (BSM). It will enable the potential of the overall SBN sterile neutrino program by performing a precise characterization of the unoscillated event rate, and constraining BNB flux and neutrino-argon cross-section systematic uncertainties. In this talk, the physics reach, current status, and future prospects of SBND are discussed.

43 PARTICLE ACCELERATORS↗

Calibration and Timing Performance of the Light Detection System in the ICARUS Detector

ICARUS is the largest Liquid Argon Time Projection Chamber (LArTPC) in operation and serves as the Far Detector of the Short Baseline Neutrino (SBN) program at Fermilab. It aims to investigate the possible existence of sterile neutrinos with $\Delta m^2 \approx \SI{1}{eV^2}$ using the Booster Neutrino Beam (BNB) and explore physics beyond the Standard Model with the Neutrinos at the Main Injector (NuMI) beam. The ICARUS light detection system, comprising 360 TPB-coated large-area Photo-Multiplier Tubes (PMTs), is crucial for triggering and event reconstruction. Due to its shallow installation, the detector is exposed to a high flux of cosmic rays, necessitating precise timing to reject background events and align neutrino interactions with the beam time profile. This talk will detail the timing inter-calibration procedures for the ICARUS light detection system, which achieve sub-nanosecond resolution. Additionally, the performance of the system in reconstructing the timing of neutrino interactions from the BNB and NuMI beams will be discussed. The results highlight the effectiveness of the ICARUS light detection system in enhancing the detector's capability for precise and reliable neutrino selection.

43 PARTICLE ACCELERATORS↗

Status of the Short-Baseline Near Detector at Fermilab

The Short-Baseline Near Detector (SBND) is one of the Liquid Argon Time Projection Chamber (LArTPC) neutrino detectors positioned along the axis of the Booster Neutrino Beam (BNB) at Fermilab, and is the near detector in the Short-Baseline Neutrino (SBN) Program. The detector completed commissioning and began taking neutrino data in the summer of 2024. SBND is characterized by superb imaging capabilities and will record around 2 million neutrino interactions per year. Thanks to its unique combination of measurement resolution and statistics, SBND will soon carry out a rich program of neutrino interaction measurements and novel searches for physics beyond the Standard Model (BSM). As the near detector, it will enable the full potential of the SBN sterile neutrino program by performing a precise characterization of the unoscillated event rate and constraining BNB flux and neutrino-argon cross-section systematic uncertainties. In this talk, the physics reach, current status, and future prospects of SBND are discussed.

Paton, Josephine [Fermilab]↗

Constraining Systematics at SBND to Reduce Uncertainties in SBN Oscillation Analyses

The Short Baseline Near Detector (SBND) is a crucial component of the Short Baseline Neutrino (SBN) Program, situated 110 meters from the Booster Neutrino Beam (BNB) target. This 112-ton Liquid Argon Time Projection Chamber (LArTPC) Near Detector is optimally positioned to investigate the potential existence of an additional flavor of neutrino through neutrino oscillation. Due to its proximity to the BNB target, SBND is uniquely positioned to receive a high rate of un-oscillated neutrino events. This setup offers a valuable opportunity to examine exclusive channels, thereby enhancing our understanding of various neutrino interaction modes, aiding in the understanding and mitigation of various sources of uncertainties. By fully utilizing the detector's capabilities, we aim to mitigate significant uncertainties in neutrino oscillation studies, primarily those related to neutrino interactions and flux. Achieving a deeper understanding of these uncertainties and controlling them with near detector data is essential. In this poster I will present an SBND event selection to control these uncertainties for the SBN oscillation analyses.

Yadav, Shweta [Texas U., Arlington]↗

Status and Prospects of SBND

The Short-Baseline Near Detector (SBND) is one of the neutrino detectors positioned along the the Booster Neutrino Beam (BNB) at Fermilab. It is the near detector in the Short-Baseline Neutrino (SBN) Program, as well as having a wide-ranging independent physics program. The detector began taking neutrino data in the summer of 2024 and has already collected over 1 million neutrino events. Thanks to its unique combination of measurement resolution and statistics, SBND will soon carry out a rich program of neutrino interaction measurements and novel searches for physics beyond the Standard Model (BSM). As the SBN near detector, it will enable the full potential of the SBN sterile neutrino program by performing a precise characterisation of the unoscillated event rate and constraining BNB flux and neutrino-argon cross-section systematic uncertainties. In this talk, the physics reach, current status, and future prospects of SBND are discussed.

Paton, Josephine [Fermilab]↗

Electromagnetic shower reconstruction in the ICARUS liquid argon time projection chamber detector

The ICARUS-T600 liquid argon time projection chamber (LArTPC) detector is taking data at shallow depth as the far detector of the Short Baseline Neutrino (SBN) program at Fermilab, to search for a possible sterile neutrino signal at $\Delta m^{2} \approx 1~\text{eV}^{2}$ with the Booster (BNB) and Main Injector (NuMI) neutrino beams at $\GeV{\sim 0.8}$ and $\GeV{\sim 2}$ average energies respectively. The LArTPC technology, developed by the ICARUS collaboration and now a standard in neutrino physics, offers impressive charged-particle imaging capabilities with $\sim1 \ \text{mm}$ spatial resolution, enabling efficient discrimination between track-like signatures (e.g., from muons, pions, and protons) and electromagnetic showers (from electrons and photons). Moreover, electron and photon signatures can be distinguished both with the calorimetric measurement of local energy depositions at the shower start and with the cm-scale conversion gap signature of photons. This contribution discusses event reconstruction at ICARUS focusing on Pandora, a multi-algorithm pattern recognition software widely used in LArTPC experiments. Over a hundred Pandora algorithms and tools are used to reconstruct cosmic rays and neutrino interactions in the ICARUS detector. Recent developments have focused on the reconstruction of electromagnetic shower signatures, crucial to ensure a robust and efficient reconstruction of charged-current $\nu_e$ interactions, which serve as a key signature of sterile neutrino oscillations at SBN. In this contribution, recent improvements to the reconstruction are discussed, focusing on the discrimination between tracks and electromagnetic showers using neutrino simulations and data.

Triozzi, Riccardo [Padua U.; INFN, Padua] (ORCID:0↗

Exploiting the PRISM Feature and Purity Monitors of the SBND Neutrino Detector

The Short-Baseline Neutrino (SBN) program at Fermilab will pursue neutrino properties searches, exploiting three Liquid Argon Time Projection Chamber (LArTPC) experiments to investigate neutrino oscillations with neutrinos from the Booster Neutrino Beam (BNB). SBND will be the near detector in the program, measuring the un-oscillated flux. It is anticipated to begin operating in 2023. Thanks to its peculiar proximity to the neutrino source of about 110 meters, SBND will collect extremely high statistics data of the flux in the GeV energy range, providing unprecedented precision measurements. SBND particular setting also allows to take measurements at different distances from BNB’s center maintaining statistics high enough at each range. LArTPC and the cold electronics technologies, as well as the argon-neutrino interaction studies, will play a key role in future neutrino physics. In this prospect, this work was focused on two SBND features: SBND PRISM tool, with the aim of investigating neutrino flux at different distances from the beam axis, and Purity Monitors, which provide a clever measurement of argon purity in the detector, whose value is fundamental in neutrino-argon interaction.

43 PARTICLE ACCELERATORS↗

Analysis of the automatic reconstruction of protons from simulated neutrino interactions in the ICARUS detector: study of the performance of track vs shower discrimination algorithms

ICARUS, Imaging Cosmic and Rare Underground Signals, is the far detector of the Short Baseline Neutrino (SBN) Program at Fermi National Accelerator Laboratory (FNAL). This program was born with the purpose of definitely explaining some anomalies in the field of neutrino oscillation physics, that can suggest the existence of a 4-type of neutrino: the sterile neutrino. It doesn’t interact directly with ordinary matter through the weak interaction, but we can observed the effect of its oscillation. In this chapter I will briefly observe: • the physics goals of the SBN Program; • the role of ICARUS as SBN far detector; • the detection technology.

43 PARTICLE ACCELERATORS↗

Toward SBND's First Cross Section Measurements

The Short-Baseline Near Detector (SBND) is one of the Liquid Argon Time Projection Chamber (LArTPC) neutrino detectors positioned along the axis of the Booster Neutrino Beam (BNB) at Fermilab, and is the near detector in the Short-Baseline Neutrino (SBN) Program. The detector completed commissioning and began taking neutrino data in the summer of 2024. SBND is characterized by superb imaging capabilities and recorded over two million neutrino interactions during its first physics run, which concluded in July 2025. Thanks to its unique combination of measurement resolution and statistics, SBND is carrying out a rich program of neutrino interaction measurements and novel searches for physics beyond the Standard Model (BSM). As the near detector, it will enable the full potential of the SBN sterile neutrino program by performing a precise characterization of the unoscillated event rate and constraining BNB flux and neutrino-argon cross-section systematic uncertainties. In addition, SBND will provide valuable model constraints for DUNE by leveraging the significant overlap in phase space between neutrino interactions in the two experiments. In this talk, I will present the current efforts within the SBND cross section program, discuss their status, and outline the plans for the first physics publications.

Oh, Sungbin [Fermilab]↗

Value of Nuclear Energy to the Reliability of the North American Power System: Results for Western and Eastern Interconnections

This report documents the fulfillment of a milestone for the United States (U.S.) Department of Energy Office of Nuclear Energy Light Water Reactor Sustainability Program: completing a baseline study of regional impact of nuclear power plants and hydrogen production in maintaining grid services and power quality. Models have been comprehensively demonstrated for the Western Interconnection, or Western Electric Coordinating Council area, and in the Eastern Interconnection for scenarios representative of past extreme events (e.g., drought and heat waves). Understanding the impact on the reliability of the bulk electric system of any reduction in generation capacity from nuclear power, for any reason, is the motivation of this work. Factors that might lead to the premature or unplanned closure of nuclear plants, extended outages, or repurposing of nuclear power include: • Aging infrastructure: Many nuclear power plants in the U.S. are nearing the end of their designed operating lives. Upgrading aging infrastructure can be expensive, and some utilities may choose to retire plants rather than invest in costly upgrades. • Low wholesale electricity prices: The deregulation of the electricity market in many states has led to increased competition and driven down wholesale electricity prices, causing nuclear power operators to seek other revenue sources for their heat and power such as clean hydrogen production. • Renewables growth: The rapid growth of renewable energy sources like solar and wind power is posing a challenge to traditional generation sources like nuclear. While many see renewables as a key part of the clean energy transition, their intermittent nature requires additional grid solutions for reliable power supply. • The potential for regulatory decisions to be in conflict: In its 2021 rulemaking, EPA rule (86 FR 880), the Environmental Protection Agency (EPA) set a compliance date for the ban on processing and distribution in commerce of Decabromodiphenyl Ether (DecaBDE). Since DecaBDE is in many components, particularly wiring, of nuclear power plants which are deemed safety-related or important to safety, three plants would not have been able to restart after their 2023 spring outages, and numerous others would have faced issues in the near future. Fortunately, in this case, the EPA provided relief to the nuclear energy industry. The report provides a summary of the significant role nuclear energy plays in the United States’ power generation mix, supplying around 20% of the nation’s electricity generation, spread across 28 U.S. states. Nuclear power is reliable, mostly unaffected by weather and seasonal changes, and provides a consistent source of baseload power. In terms of capacity, nuclear power plants account for as much as 26% of balancing area power generation capacity. Nuclear power also provides a substantial contribution (e.g., 10% of the inertia in the Eastern Interconnection) of the synchronous spinning mass/inertia that buffers the rate at which frequency changes when a load and generation imbalance occurs (e.g., a large plant trips or a load is suddenly shed due to a transmission outage). This contribution is critical for maintaining grid stability during sudden changes in load or generation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Calibration and Performance of the ICARUS Detector at Fermilab

ICARUS is the largest Liquid Argon Time Projection Chamber (LArTPC) in operation and serves as the Far Detector of the Short Baseline Neutrino (SBN) program at Fermilab. Precise detector calibration is essential for reliable energy reconstruction and for maximizing the physics reach of the experiment. In this talk, I will describe the energy and timing calibration procedures developed at ICARUS. Thanks to the abundant flux of cosmic ray muons at the surface, the TPC response to ionization charge has been equalized across the detector, removing non-uniformities and in-transparency effects. A novel data-driven procedure has been used to tune the simulation of ionization signals and electronics noise yielding close agreement between Monte Carlo and data with minimal residual bias in reconstructed charge. In addition, the light detection system has been calibrated to sub-nanosecond timing resolution. This precision enables efficient cosmic background rejection and accurate synchronization of neutrino interactions with the time structure of both the Booster Neutrino Beam (BNB) and Neutrinos at the Main Injector (NuMI) beam. Together, these efforts demonstrate the robust performance of the detector and provide critical experience for future large LArTPCs, such as DUNE.

Vicenzi, Matteo [Brookhaven]↗

The Trigger System of ICARUS-T600 Detector at Fermilab

The ICARUS-T600 liquid argon (LAr) time projection chamber (TPC) detector is currently deployed as a far detector of the Short Baseline Neutrino (SBN) program at Fermilab (USA) to search for a possible LSND-like sterile neutrino signal at $\Deltam^2 \approx 1eV^2$ with the Booster (BNB) and Main Injector (NuMI) Neutrino Beams. A global physical event rate of $\approx 0.6$ Hz, including the genuine neutrino interactions in LAr, beam halos and cosmic interactions inside the proton pulse time windows, is expected, roughly corresponding to $\approx 4$ PB of data for the total 6.6 $10^{20}$ pot exposure if the full ICARUS-T600 detector is readout ($\approx 200$ MB event size). The designed trigger system described here will collect the genuine neutrino interactions with a $\approx 95$\% expected efficiency.

Copello, S. [INFN, Pavia]↗