Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “arterial”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Excursion of vibrating microelectrodes in tissue

The paper deals with a vibrating microelectrode holder consisting of a support rod attached to the cone of a miniature loudspeaker. This holder facilitates a microelectrode penetration into arterial wall tissue, eliminates surface dimpling, and relieves polarographic artifacts believed to be due to tissue compression. The paper presents construction and performance details of the electrode holder, and evaluates the extent of possible damage incurred during such vibration by measuring electrode motion relative to surrounding tissue in an excised segment of femoral artery in the rabbit. It is concluded that under proper vibratory conditions microelectrodes can be easily inserted into the arterial wall with minimum tissue disturbance.

Kanabus, E. W.↗

The OAO heat pipes - 8 1/2 years of flight data

Heat pipe performance data taken during the 8 1/2 years of flight of the OAO-C (Copernicus) spacecraft are presented. Three fixed conductance heat pipes (FCHP), each with different wicking concepts (axial groove, pedestal artery, and self-priming spiral artery), and one variable conductance heat pipe (VCHP) are onboard. Aluminum tubes (1/2 in. diameter) rolled into a 48 in. loop containing ultra high purity ammonia as the heat transfer fluid comprise all FCHP, whose purpose is to circumferentially isothermalize the central tube housing the telescope. The VCHP is a hot, non-wicked reservoir concept including a composite artery and methanol heat transfer fluid, and is used to maintain the temperature of the onboard processor. Flight thermal data analysis reveals that no degradation in performance occurred since launch and agrees well with pre-flight data; the onboard processor still shows an offset in control range of 4 F, and the pipes perform the same after 8 1/2 years in orbit.

Harwell, W.↗

Computer assessment of atherosclerosis from angiographic images

A computer method for detection and quantification of atherosclerosis from angiograms has been developed and used to measure lesion change in human clinical trials. The technique involves tracking the vessel edges and measuring individual lesions as well as the overall irregularity of the arterial image. Application of the technique to conventional arterial-injection femoral and coronary angiograms is outlined and an experimental study to extend the technique to analysis of intravenous angiograms of the carotid and cornary arteries is described.

Selzer, R. H.↗

The identification of the variation of atherosclerosis plaques by invasive and non-invasive methods

Computer-enhanced visualization of coronary arteries and lesions within them is discussed, comparing invasive and noninvasive methods. Trial design factors in computer lesions assessment are briefly discussed, and the use of the computer edge-tracking technique in that assessment is described. The results of a small pilot study conducted on serial cineangiograms of men with premature atherosclerosis are presented. A canine study to determine the feasibility of quantifying atherosclerosis from intravenous carotid angiograms is discussed. Comparative error for arterial and venous injection in the canines is determined, and the mode of processing the films to achieve better visualization is described. The application of the computer edge-tracking technique to an ultrasound image of the human carotid artery is also shown and briefly discussed.

Selzer, R. H.↗

Transpulmonary passage of venous air emboli

Twenty-seven paralyzed anesthetized dogs were embolized with venous air to determine the effectiveness of the pulmonary vasculature for bubble filtration or trapping. Air doses ranged from 0.05 to 0.40 ml/kg min in 0.05-ml increments with ultrasonic Doppler monitors placed over arterial vessels to detect any microbubbles that crossed the lungs. Pulmonary vascular filtration of the venous air infusions was complete for the lower air doses ranging from 0.05 to 0.30 ml/kg min. When the air doses were increased to 0.35 ml/kg min, the filtration threshold was exceeded with arterial spillover of bubbles occurring in 50 percent of the animals and reaching 71 percent for 0.40 ml/kg min. Significant elevations were observed in pulmonary arterial pressure and pulmonary vascular resistance. Systemic blood pressure and cardiac output decreased, whereas left ventricular end-diastolic pressure remained unchanged. The results indicate that the filtration of venous bubbles by the pulmonary vasculature was complete when the air infusion rates were kept below a threshold value of 0.30 ml/kg min.

Butler, B. D.↗

Continuous blood densitometry - Fluid shifts after graded hemorrhage in animals

Rapid fluid shifts in four pigs and two dogs subjected to graded hemorrhage are investigated. Arterial blood density (BD), mean arterial pressure (MAP), central venous pressure (CVP), arterial plasma density (PD), hematocrit (Hct) and erythrocyte density were measured. The apparatus and mechancial oscillator technique for measuring density are described. Fluid shifts between red blood cells and blood plasma and alterations in the whole-body-to-large vessel Hct, F(cell) are studied using two models. The bases of the model calculations are discussed. A decrease in MAP, CVP, and BP is detected at the beginning of hemorrhaging; continued bleeding results in further BD decrease correlating with volume displacement. The data reveal that at 15 ml/kg blood loss the mean PD and BD dropped by 0.99 + or - 0.15 and 2.42 + or 0.26 g/liter, respectively, and the Hct dropped by 2.40 + or 0.47 units. The data reveal that inward-shifted fluid has a higher density than normal ultrafiltrate and/or there is a rise in the F(cell) ratio. It is noted that rapid fluid replacement ranged from 5.8 + or - 0.8 to 10.6 + or - 2.0 percent of the initial plasma volume.

Hinghofer-Szalkay, H.↗

Alternate high capacity heat pipe

The performance predictions for a fifty foot heat pipe (4 foot evaporator - 46 foot condensor) are discussed. These performance predictions are supported by experimental data for a four foot heat pipe. Both heat pipes have evaporators with axial groove wick structures and condensers with powder metal external artery wick structures. The predicted performance of a rectangular axial groove/external artery heat pipe operating in space is given. Heat transport versus groove width is plotted for 100, 200 and 300 grooves in the evaporator. The curves show that maximum power is achieved for groove widths from 0.040 to 0.053 as the number of grooves varies from 300 to 100. The corresponding range of maximum power is 3150 to 2400 watts. The relationships between groove width and heat pipe evaporate diameter for 100, 200 and 300 grooves in the evaporator are given. A four foot heat pipe having a three foot condenser and one foot evaporator was built and tested. The evaporator wick structure used axial grooves with rectangular cross sections, and the condenser wick structure used powder metal with an external artery configuration. Fabrication drawings are enclosed. The predicted and measured performance for this heat pipe is shown. The agreement between predicted and measured performance is good and therefore substantiates the predicted performance for a fifty foot heat pipe.

Voss, F. E.↗

Leg vascular responsiveness during acute orthostasis following simulated weightlessness

The effect of weightlessness on vascular response to orthostatic stress was investigated in human subjects by measuring changes in the arterial pulse volume (APV) of the legs during exposure to lower body negative pressure (LBNP) applied before and after 10 days of continuous 6-deg head-down bed rest. Heart rate, mean arterial blood pressure (MAP), and impedance rheographic indices of APV were measured during rest and at 1 min of -30 mm Hg LBNP. Bed rest was found not to alter the responses of MAP to LBNP. Resting APV was decreased after bed rest; however, APV was reduced upon transfer from rest to 1-min LBPN by the same relative magnitude before and after bedrest. It is concluded that peripheral arterial vasoconstriction, as indicated by reduction in APV during LBNP, is not affected by bedrest. The results suggest that there was no apparent alteration in responsiveness of the leg vasculature following simulated weightlessness, and that the control mechanisms of peripheral resistance do not contribute significantly to reduced orthostatic tolerance following spaceflight.

Blamick, Cynthia A.↗

Capillary heat transport and fluid management device

A passive heat transporting and fluid management apparatus including a housing in the form of an extruded body member having flat upper and lower surfaces is disclosed. A main liquid channel and at least two vapor channels extend longitudinally through the housing from a heat input end to a heat output end. The vapor channels have sintered powdered metal fused about the peripheries to form a porous capillary wick structure. A substantial number of liquid arteries extend transversely through the wicks adjacent the respective upper and lower surfaces of the housing, the arteries extending through the wall of the housing between the vapor channels and the main liquid channel and open into the main liquid channel. Liquid from the main channel enters the artery at the heat input end, wets the wick and is vaporized. When the vapor is cooled at the heat output end, the condensed vapor refills the wick and the liquid reenters the main liquid channel.

James W Owen↗

Development of the Single Graded Groove high-performance heat pipe

This paper describes the development of a new nonarterial heat pipe with a nominal transport capability of 100,000 W in. Data are presented for one-g transport capability as a function of tilt and working fluid quantity. The transport capability agrees well with theoretical predictions. The LMSC Graded Groove Heat Pipe exhibits the high throughput and excellent heat transfer characteristics of earlier arterial designs such as the LMSC Tapered Artery Heat Pipe. At the same time, it suffers none of the priming difficulties associated with the arterial designs.

Ambrose, J. H.↗

Cerebral blood velocity and other cardiovascular responses to 2 days of head-down tilt

Spaceflight induces a cephalad redistribution of fluid volume and blood flow within the human body, and space motion sickness, which is a problem during the first few days of space flight, could be related to these changes in fluid status and in blood flow of the cerebrum and vestibular system. To evaluate possible changes in cerebral blood flow during simulated weightlessness, we measured blood velocity in the middle cerebral artery (MCA) along with retinal vascular diameters, intraocular pressure, impedance cardiography, and sphygmomanometry on nine men (26.2 +/- 6.6 yr) morning and evening for 2 days during continuous 10 deg head-down tilt (HDT). When subjects went from seated to head-down bed rest, their heart rate and retinal diameters decreased, and intraocular pressures increased. After 48 h of HDT, blood flow velocity in the MCA was decreased and thoracic impedance was increased, indicating less fluid in the thorax. Percent changes in blood flow velocities in the MCA after 48 h of HDT were inversely correlated with percent changes in retinal vascular diameters. Blood flow velocities in the MCA were inversely correlated (intersubject) with arterial pressures and retinal vascular diameters. Heart rate, stroke volume, cardiac output, systolic arterial pressure, and at times pulse pressure and blood flow velocities in the MCA were greater in the evening. Total peripheral resistance was higher in the morning. Although cerebral blood velocity is reduced after subjects are head down for 2 days, the inverse relationship with retinal vessel diameters, which have control analogous to that of cerebral vessels, indicates cerebral blood flow is not reduced.

Frey, Mary A. B.↗

Leg Vascular Responsiveness During Acute Orthostasis Following Simulated Weightlessness

Ten men (35-49 years old) underwent lower body negative pressure (LBNP) exposures before and offer 10 d of continuous 6 degrees head-down bedrest in order to predict the effect of weightlessness on the responsiveness of leg vasculature to an orthostatic stress. Heart rate (HR), mean arterial blood pressure (MAP), and Impedance rheographic indices of arterial pulse volume (APV) of the legs were measured during rest and at 1 min at -30 mm Hg LBNP. Bedrest-induced deconditioning was manifested by decreases (p less than 0.06) in plasma volume (17%), peak oxygen uptake (16%), and LBNP tolerance (17%). Resting HR was unchanged after bedrest, but HR was higher (p less than 0.05) at 1 min of -30 mm Hg LBNP after, compared with before bedrest. Responses of MAP to -30 mm Hg LBNP were not altered by bodrest. Resting APV was decreased (p less than 0.05) by simulated weightlessness. However, APV was reduced (p less than 0.05) from rest to 1 min -30 mm Hg LBNP by the same relative magnitude before and after bodrest (-21.4 +/- 3.4% and -20.5 +/- 2.7%, respectively). We conclude that peripheral arterial vasoconstriction, as indicated by reductions in APV during LBNP, was not affected by bedrest. These results suggest that there was no apparent alteration in responsiveness of the leg vasculature following simulated weightlessness. Therefore, it appears unlikely that control mechanisms of peripheral resistance contribute significantly to reduced orthostatic tolerance following space-flight.

Blamick, Cynthia A.↗

BP and Vascular Function Following Space Flight

Blood pressure and mesenteric resistance artery function were assessed in 9-week-old spontaneously hypertensive rats following an 18 day shuttle flight on STS-80. Blood pressure was measured twice, first in conscious animals using a tail-cuff method and then while the animals were anesthetized with 2% halothane in O2. Isolated mesenteric resistance artery responses to cumulative additions of norepinephrine, acetylcholine, sodium nitroprusside, and calcium were measured within 17 hours of landing using wire myography. Blood pressure was slightly reduced in conscious animals following flight (p=0.056) but was significantly elevated (p less than.001) above vivarium control group values in anesthetized animals. Maximal contraction of mesenteric arteries to norepinephrine was attenuated in the flight animals (p less than.001)aswasrelaxationtoacetylcholine(p less than .001)andcalcium(p less than .05). There was no difference between flight and control animals in the vessel response to sodium nitroprusside (p greater than .05). The results suggest that there may have been an increase in synthesis and release of nitric oxide in the flight animals.

Hatton, Daniel C.↗

Paraventricular Stimulation with Glutamate Elicits Bradycardia and Pituitary Responses

The excitatory neurotransmitter, L-glutamate (0.5 M, pH 7.4), or the organic acid, acetate (0.5 M, pH 7.4), was microinjected (50 nl over 2 min) directly into the paraventricular nuclei (PVN) of pentobarbital sodium-anesthetized rats while arterial blood pressure and heart rate and plasma adrenocorticotropic hormone (ACTH), vasopressin, and oxytocin were measured. Activation of PVN neurons with L-glutamate led to increases in plasma ACTH, vasopressin, and oxytocin and a profound bradycardia (-80 beats/min) with little change in arterial blood pressure. Microinjection of acetate had no effect on the above variables. The decrease in heart rate was shown to be dependent on the concentration of glutamate injected and the volume of injectate. The bradycardia was mediated through the autonomic nervous system because ganglionic blockade (pentolinium tartrate) eliminated the response; atropine and propranolol severely attenuated the bradycardia. The bradycardia was greatest when L-glutamate was microinjected into the caudal PVN. Injections into the rostral PVN or into nuclei surrounding the PVN led to small or nonsignificant decreases in heart rate. Focal electric stimulation (2-50 pA) of the PVN also led to decreases in heart rate and arterial blood pressure. These data suggest that activation of PVN neurons leads to the release of ACTH, vasopressin, and oxytocin from the pituitary and a bradycardia that is mediated by the autonomic nervous system.

Darlington, Daniel N.↗

Mechanism of Headward Fluid Shift During Exposure To Microgravity

A prominent feature of early cardiovascular adaptation to the microgravity of space flight is a shift of blood and tissue fluid from the lower body to the upper body. Symptoms of this fluid shift include facial edema, nasal congestion, and headache. Normally on Earth, the human body is exposed to hydrostatic (gravitational) blood pressure gradients during upright posture. In this posture, mean arterial pressures at head, heart, and foot levels are approximately 70, 100, and 200 mm Hg, respectively. Theoretically, all hydrostatic pressures within arteries and veins are lost during exposure to microgravity so that mean arterial pressure in all regions of the body is uniform and approximately equal to that at heart level (100 mm Hg). Acute studies of 60 head-down tilt (simulated microgravity on Earth) indicate that facial edema is caused by: 1) elevation of capillary blood pressure from 28 to 34 mm Hg, 2) reduction of blood colloid osmotic pressure 22 to 18 mm Hg, and 3) 50% increase of blood perfusion in tissues of the head. Furthermore, as compared to microvasculature in the feet, microvessels of the head have a low capacity to constrict and diminish local perfusion. Elevation of blood and tissue fluid pressures/flow in the head may also explain the higher headward bone density associated with long-term head-down tilt. These mechanistic studies of head-down tilt, along with a better understanding of the relative stresses involved with upright posture and lower body negative pressure, have facilitated development of physiologic countermeasures to maintain astronaut health during microgravity. Presently no exercise hardware is available to provide a blood pressure gradient from head to feet in space. However, recent studies in our laboratory suggest that treadmill exercise within lower body negative pressure provides equivalent or greater physiologic stress as compared to similar upright exercise on Earth.

Hargens, Alan R.↗

Development of the Aortic Baroreflex in Microgravity

Baroreceptors sense pressure in blood vessels and send this information to the brain. The primary baroreceptors are located in the main blood vessel leaving the heart (the aorta) and in the arteries in the neck (the carotid arteries). The brain uses information from the baroreceptors to determine whether blood pressure should be raised or lowered. These reflex responses are called baroreflexes. Changing position within a gravity field (i.e., moving from lying to sitting or standing) powerfully stimulates the baroreflexes. In weightlessness, the amount of stimuli that the baroreflexes receive is dramatically reduced. If this reduction occurs when the pathways that control the baroreflexes are being formed, it is possible that either the structure or function of the baroreceptors may be permanently changed. To study the effect of microgravity on structural and functional development of the aortic baroreflex system, we studied young rats (eight days old at launch) that flew on the Space Shuttle Columbia for 16 days. Six rats were studied on landing day; another six were studied after re-adapting to Earth's gravity for 30 days. On both landing day and 30 days after landing, we tested the sensitivity of the rats' baroreflex response. While the rats were anaesthetized, we recorded their arterial pressure, heart rate, and aortic nerve activity. After the tissues were preserved with perfusion fixation, we also examined the baroreflex structures. On landing day, we found that, compared to the controls, the flight rats had: fewer unmyelinated nerve fibers in their aortic nerves lower baroreflex sensitivity significantly lower contraction ability and wall tension of the aorta a reduced number of smooth muscle cells in the aorta. In the 30-day recovery group, the sensitivity of the baroreflex showed no difference between the flight rats and the control groups, although the unmyelinated fibers of the aortic nerve remained reduced in the flight rats. The results show that spaceflight does affect the development of the aortic baroreflex. The sensitivity of the reflex may be suppressed; however, the function of the blood pressure control system can re-adapt to Earth's gravity if the rats return before maturation. The structural differences in the input pathway of the reflex (Le., the reduction in nerve fibers) may remain permanently.

Shimizu, Tsuyoshi↗

Numerical Models of Human Circulatory System under Altered Gravity: Brain Circulation

A computational fluid dynamics (CFD) approach is presented to model the blood flow through the human circulatory system under altered gravity conditions. Models required for CFD simulation relevant to major hemodynamic issues are introduced such as non-Newtonian flow models governed by red blood cells, a model for arterial wall motion due to fluid-wall interactions, a vascular bed model for outflow boundary conditions, and a model for auto-regulation mechanism. The three-dimensional unsteady incompressible Navier-Stokes equations coupled with these models are solved iteratively using the pseudocompressibility method and dual time stepping. Moving wall boundary conditions from the first-order fluid-wall interaction model are used to study the influence of arterial wall distensibility on flow patterns and wall shear stresses during the heart pulse. A vascular bed modeling utilizing the analogy with electric circuits is coupled with an auto-regulation algorithm for multiple outflow boundaries. For the treatment of complex geometry, a chimera overset grid technique is adopted to obtain connectivity between arterial branches. For code validation, computed results are compared with experimental data for steady and unsteady non-Newtonian flows. Good agreement is obtained for both cases. In sin-type Gravity Benchmark Problems, gravity source terms are added to the Navier-Stokes equations to study the effect of gravitational variation on the human circulatory system. This computational approach is then applied to localized blood flows through a realistic carotid bifurcation and two Circle of Willis models, one using an idealized geometry and the other model using an anatomical data set. A three- dimensional anatomical Circle of Willis configuration is reconstructed from human-specific magnetic resonance images using an image segmentation method. The blood flow through these Circle of Willis models is simulated to provide means for studying gravitational effects on the brain circulation under auto-regulation.

Kim, Chang Sung↗

Oscillatory shear stress stimulates endothelial production of O2- from p47phox-dependent NAD(P)H oxidases, leading to monocyte adhesion

Arterial regions exposed to oscillatory shear (OS) in branched arteries are lesion-prone sites of atherosclerosis, whereas those of laminar shear (LS) are relatively well protected. Here, we examined the hypothesis that OS and LS differentially regulate production of O2- from the endothelial NAD(P)H oxidase, which, in turn, is responsible for their opposite effects on a critical atherogenic event, monocyte adhesion. We used aortic endothelial cells obtained from C57BL/6 (MAE-C57) and p47phox-/- (MAE-p47-/-) mice, which lack a component of NAD(P)H oxidase. O2- production was determined by dihydroethidium staining and an electron spin resonance using an electron spin trap methoxycarbonyl-2,2,5,5-tetramethyl-pyrrolidine. Chronic exposure (18 h) to an arterial level of OS (+/- 5 dynes/cm2) increased O2- (2-fold) and monocyte adhesion (3-fold) in MAE-C57 cells, whereas chronic LS (15 dynes/cm2, 18 h) significantly decreased both monocyte adhesion and O2- compared with static conditions. In contrast, neither LS nor OS were able to induce O2- production and monocyte adhesion to MAE-p47-/-. Treating MAE-C57 with a cell-permeable superoxide dismutase compound, polyethylene glycol-superoxide dismutase, also inhibited OS-induced monocyte adhesion. In addition, over-expressing p47phox in MAE-p47-/- restored OS-induced O2- production and monocyte adhesion. These results suggest that chronic exposure of endothelial cells to OS stimulates O2- and/or its derivatives produced from p47phox-dependent NAD(P)H oxidase, which, in turn, leads to monocyte adhesion, an early and critical atherogenic event.

NASA Program Fundamental Space Biology↗