Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “aperture coupled”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

GLOW: The Goddard Lidar Observatory for Winds

GLOW (Goddard Lidar Observatory for Winds) is a mobile Doppler lidar system which uses direct detection Doppler lidar techniques to measure wind profiles from the surface into the lower stratosphere. The system is contained in a modified van to allow deployment in field operations. The lidar system uses a Nd:YAG laser transmitter to measure winds using either aerosol backscatter at 1064 nm or molecular backscatter at 355 nm. The receiver telescope is a 45 cm Dall-Kirkham which is fiber coupled to separate Doppler receivers, one optimized for the aerosol backscatter wind measurement and another optimized for the molecular backscatter wind measurement. The receivers are implementations of the 'double edge' technique and use high spectral resolution Fabry-Perot etalons to measure the Doppler shift. A 45 cm aperture azimuth-over-elevation scanner is mounted on the roof of the van to allow full sky access and a variety of scanning options. GLOW is intended to be used as a deployable field system for studying atmospheric dynamics and transport and can also serve as a testbed to evaluate candidate technologies developed for use in future spaceborne systems. In addition, it can be used for calibration/validation activities following launch of spaceborne wind lidar systems. A description of the mobile system is presented along with the examples of lidar wind profiles obtained with the system.

Gentry, Bruce M.↗

GLOW- The Goddard Lidar Observatory for Winds

GLOW (Goddard Lidar Observatory for Winds) is a mobile Doppler lidar system which uses direct detection Doppler lidar techniques to measure wind profiles from the surface into the lower stratosphere. The system is contained in a modified van to allow deployment in field operations. The lidar system uses a Nd:YAG laser transmitter to measure winds using either aerosol backscatter at 1064 nm or molecular backscatter at 355 nm. The receiver telescope is a 45 cm Dall-Kirkham which is fiber coupled to separate Doppler receivers, one optimized for the aerosol backscatter wind measurement and another optimized for the molecular backscatter wind measurement. The receivers are implementations of the 'double edge' technique and use high spectral resolution Fabry-Perot etalons to measure the Doppler shift. A 45 cm aperture azimuth-over-elevation scanner is mounted on the roof of the van to allow full sky access and a variety of scanning options. GLOW is intended to be used as a deployable field system for studying atmospheric dynamics and transport and can also serve as a testbed to evaluate candidate technologies developed for use in future spaceborne systems. In addition, it can be used for calibration/validation activities following launch of spaceborne wind lidar systems. A description of the mobile system is presented along with the examples of lidar wind profiles obtained with the system.

Gentry, Bruce M.↗

Error analysis of image reconstruction by a synthetic aperture interferometric radiometer

An error analysis is presented for the image reconstruction algorithm currently employed by the electronically steered thinned array radiometer aircraft instrument. This instrument samples components of the Fourier transform of the brightness temperature distribution at 1.4 GHz. Sources of error are identified, including systematic offsets and stochastic noise in the measurements, errors in the interference pattern antenna calibration, multipath scattering from the antenna support structure, mutual coupling between nearby array elements, and variations in the antenna patterns of the array elements. These errors are shown to produce artifacts in the image which appear as 'streaks' running along the instrument flight line. Possible hardware corrections are discussed. These include a reduction in the profile of the antenna support structure and a decoupling of adjacent and other nearby array elements using corrugated 'skirts'. Also discussed are several image enhancement techniques which detect and correct for some of the streaking. These techniques include a renormalization of the interference patterns based on the measured element patterns, a perturbation based interpretation of image contrast, and a covariance analysis of noise present in the image.

Ruf, Christopher S.↗

Imaging of gamma-Irradiated Regions of a Crystal

A holographic technique has been devised for generating a visible display of the effect of exposure of a photorefractive crystal to gamma rays. The technique exploits the space charge that results from trapping of electrons in defects induced by gamma rays. The technique involves a three-stage process. In the first stage, one writes a holographic pattern in the crystal by use of the apparatus shown in Figure 1. A laser beam of 532-nm wavelength is collimated and split into signal and reference beams by use of a polarizing beam splitter. On its way to the crystal, the reference beam goes through a two-dimensional optical scanner that contains two pairs of lenses (L1y, L2y and L1x,L2x) and mirrors M1 and M2, which can be rotated by use of micrometer drives to make fine adjustments. The signal beam is sent through a spatial light modulator that imposes the holographic pattern, then through two imaging lenses L(sub img) on its way to the crystal. An aperture is placed at the common focus of lenses Limg to suppress high-order diffraction from the spatial light modulator. The hologram is formed by interference between the signal and reference beams. A camera lens focuses an image of the interior of the crystal onto a charge-coupled device (CCD). If the crystal is illuminated by only the reference beam once the hologram has been formed, then an image of the hologram is formed on the CCD: this phenomenon is exploited to make visible the pattern of gamma irradiation of the crystal, as described next. In the second stage of the process, the crystal is removed from the holographic apparatus and irradiated with rays at a dose of about 100 krad. In the third stage of the process, the crystal is remounted in the holographic apparatus in the same position as in the first stage and illuminated with only the reference beam to obtain the image of the hologram as modified by the effect of the rays. The orientations of M1 and M2 can be adjusted slightly, if necessary, to maximize the intensity of the image. Figure 2 shows such an image that was formed in a crystal of Fe:LiNbO3.

Dragoi, Danut↗

Sharp, high numerical aperture (NA), nanoimprinted bare pyramid probe for optical mapping

The ability to correlate optical hyperspectral mapping and high resolution topographic imaging is critically important to gain deep insight into the structure–function relationship of nanomaterial systems. Scanning near-field optical microscopy can achieve this goal, but at the cost of significant effort in probe fabrication and experimental expertise. To overcome these two limitations, we have developed a low-cost and high-throughput nanoimprinting technique to integrate a sharp pyramid structure on the end facet of a single-mode fiber that can be scanned with a simple tuning-fork technique. The nanoimprinted pyramid has two main features: (1) a large taper angle (~70°), which determines the far-field confinement at the tip, resulting in a spatial resolution of 275 nm, an effective numerical aperture of 1.06, and (2) a sharp apex with a radius of curvature of ~20 nm, which enables high resolution topographic imaging. Optical performance is demonstrated through evanescent field distribution mapping of a plasmonic nanogroove sample, followed by hyperspectral photoluminescence mapping of nanocrystals using a fiber-in-fiber-out light coupling mode. Through comparative photoluminescence mapping on 2D monolayers, we also show a threefold improvement in spatial resolution over chemically etched fibers. These results show that the bare nanoimprinted near-field probes provide simple access to spectromicroscopy correlated with high resolution topographic mapping and have the potential to advance reproducible fiber-tip-based scanning near-field microscopy.

47 OTHER INSTRUMENTATION↗

A selective modal scheme for the analysis of EM coupling into or radiation from large open-ended waveguides

A selective modal scheme is proposed to efficiently analyze the problem of high-frequency (HF) electromagnetic (EM) coupling/penetration into or radiation from open-ended waveguides. This scheme is based on the phenomenon that at sufficiently high frequencies, the modes which contribute most significantly to the fields coupled into the waveguide are those whose modal ray directions are most nearly parallel to the incident-wave direction. This concept is illustrated by calculating the EM radiation and backscattering from open-ended parallel-plate, rectangular, circular, and sectoral waveguide geometries. The calculations use the usual geometrical optics, aperture field, and Ufimtsev edge current techniques. Also included are some measured results which further verify the accuracy of the above computations.

Altintas, Ayhan↗

Monolithic in-based III-V compound semiconductor focal plane array cell with single stage CCD output

A monolithic semiconductor imager includes an indium-based III-V compound semiconductor monolithic active layer of a first conductivity type, an array of plural focal plane cells on the active layer, each of the focal plane cells including a photogate over a top surface of the active layer, a readout circuit dedicated to the focal plane cell including plural transistors formed monolithically with the monolithic active layer and a single-stage charge coupled device formed monolithically with the active layer between the photogate and the readout circuit for transferring photo-generated charge accumulated beneath the photogate during an integration period to the readout circuit. The photogate includes thin epitaxial semiconductor layer of a second conductivity type overlying the active layer and an aperture electrode overlying a peripheral portion of the thin epitaxial semiconductor layer, the aperture electrode being connectable to a photogate bias voltage.

Fossum, Eric R.↗

Monolithic in-based III-V compound semiconductor focal plane array cell with single stage CCD output

A monolithic semiconductor imager includes an indium-based III-V compound semiconductor monolithic active layer of a first conductivity type, an array of plural focal plane cells on the active layer, each of the focal plane cells including a photogate over a top surface of the active layer, a readout circuit dedicated to the focal plane cell including plural transistors formed monolithically with the monolithic active layer and a single-stage charge coupled device formed monolithically with the active layer between the photogate and the readout circuit for transferring photo-generated charge accumulated beneath the photogate during an integration period to the readout circuit. The photogate includes thin epitaxial semiconductor layer of a second conductivity type overlying the active layer and an aperture electrode overlying a peripheral portion of the thin epitaxial semiconductor layer, the aperture electrode being connectable to a photogate bias voltage.

Fossum, Eric R.↗

Mold and method for molding a reinforced preform

A mold for molding a reinforced preform having at least two apertures therein includes first and second mold halves, first and second emitters disposed in the mold halves and configured to emit light therefrom, first and second receivers disposed in the mold halves and configured to receive light from the respective first and second emitters, and first and second moving members having couplings for connection with side portions of the reinforced preform and actuators for moving the couplings between respective first and second positions. A controller determines an alignment condition based on signals received from the receivers. If the alignment condition fails to meet predetermined criteria, then at least one of the actuators is caused to move its coupling from its respective first position to a respective adjusted position that is different from the respective second position.

Rodgers, William R.↗

No Clear, Direct Evidence for Multiple Protoplanets Orbiting LkCa 15: LkCa 15 bcd are Likely Inner Disk Signals

Two studies utilizing sparse aperture-masking (SAM) interferometry and Hα differential imaging have reported multiple Jovian companions around the young solar-mass star, LkCa 15 (LkCa 15 bcd): thefirst claimed direct detection of infant, newly formed planets (“protoplanets”). We present new near-infrared direct imaging/spectroscopy from the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) system coupled with Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) integral field spectrograph and multi-epoch thermal infrared imaging from Keck/ NIRC2 of LkCa 15 at high Strehl ratios. These data provide the first direct imaging look at the same wavelengths and in the same locations where previous studies identified the LkCa 15 protoplanets,and thus offer the first decisive test of their existence.The data do not reveal these planets. Instead,we resolve extended emission tracing adust disk with a brightness and location comparable to that claimed for LkCa 15 bcd. Forward-models attributing this signal to orbiting planets are inconsistent with the combined SCExAO/CHARIS and Keck/NIRC2 data. An inner disk provides a more compelling explanation for the SAM detections and perhaps also the claimed Hα detection of LkCa 15 b. We conclude that there is currently no clear, direct evidence for multiple protoplanets orbiting LkCa 15, although the system likely contains at least one unseen Jovian companion. To identify Jovian companions around LkCa 15 from future observations, the inner disk should be detected and its effect modeled, removed, and shown to be distinguishable from planets. Protoplanet candidates identified from similar systems should likewise be clearly distinguished from disk emission through modeling.

Thayne Currie↗

3D Simulations of gas injection on callovo-oxfordian claystone assuming spatial heterogeneity and anisotropy

A series of gas injection tests on Callovo-Oxfordian (COx) claystone from the Bure underground research laboratory (URL) in France were carried out at the British Geological Survey (BGS). The tests were performed using a triaxial apparatus specifically designed to capture small volumetric strains induced by the injected gas flow and consequent material dilatancy. The long-duration experiments were monitored throughout. Measurements also included pressure, stresses (axial and radial stresses prescribed for each test stage), rate of gas inflow, gas outflow volume as well as pore-pressures observed at various points of the sample. A coupled hydro-gas-mechanical 3D numerical model has been developed to simulate the tests. Initial permeability is assumed heterogeneous throughout the specimen and embedded fractures are incorporated in the formulation. Gas pressure-induced deformations during the test lead to variations of permeability due to changes in matrix porosity and, especially, fracture aperture as well as fracture orientation due to material anisotropy. A programme of sensitivity analyses involving the variation of different aspects and parameters of the model contributes to a better understanding of the phenomena and highlights its complexity. The model is able to reproduce the observed behaviour of the tests.

58 GEOSCIENCES↗

Recent H - ion source research and development at the Oak Ridge National Laboratory

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world's most intense pulsed neutron beams to a wide array of instruments which are used to conduct investigations in many fields of science and engineering. Neutrons are produced from spallation of liquid Hg by bombardment of short (~1 μs), intense (~35 A) pulses of protons delivered at 60 Hz by a storage ring which is fed by a high-intensity, ~1 GeV H - LINAC. This facility has operated almost continuously since 2006, with ion source performance increasing over those years, and currently providing 50–60 mA of H - ions with a duty-factor of 6% for maintenance-free runs of several months with near 100% availability. Ion source research and development at ORNL has played a key role in enabling and supporting this success: this report provides an update on some of the ongoing ion source research and development efforts which have been undertaken since the previous Negative Ion Beams and Sources (NIBS) conference in 2020. These include significant improvements to H - beam current by extraction from a larger source outlet aperture and improvements to the electron dumping system which should eliminate the gradual loss of electrode voltage over the course of a run which has occasionally impacted SNS operations. Improvement and simplification of the plasma ignition system for the external antenna ion source, a long-standing problem, was also realized. Lastly, RF coupling efficiency was measured for both the SNS internal and external antenna ion sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical, thermal, and electrical performance of low-CR solar arrays

This paper describes the analysis and testing of a photovoltaic low-CR concentrator shaped like a truncated pyramid with an aperture of 0.5 m on a side and a geometric concentration ratio of six. The truncated base plane is covered by either silicon (Si) or gallium arsenide (GaAs) solar cells. Ray-trace analysis of the concentrator predicts a peak optical efficiency of 0.77, which falls off only gradually with pointing error. A coupled thermal-electrical analysis of the system shows that the moderately nonuniform illumination produced by the concentrator does not result in significant mismatch losses, provided the solar cells are connected in parallel groups. The results of ground tests involving a full-scale prototype concentrator conform well with theoretical predictions.

French, E. P.↗

Target-Tracking Camera for a Metrology System

An analog electronic camera that is part of a metrology system measures the varying direction to a light-emitting diode that serves as a bright point target. In the original application for which the camera was developed, the metrological system is used to determine the varying relative positions of radiating elements of an airborne synthetic aperture-radar (SAR) antenna as the airplane flexes during flight; precise knowledge of the relative positions as a function of time is needed for processing SAR readings. It has been common metrology system practice to measure the varying direction to a bright target by use of an electronic camera of the charge-coupled-device or active-pixel-sensor type. A major disadvantage of this practice arises from the necessity of reading out and digitizing the outputs from a large number of pixels and processing the resulting digital values in a computer to determine the centroid of a target: Because of the time taken by the readout, digitization, and computation, the update rate is limited to tens of hertz. In contrast, the analog nature of the present camera makes it possible to achieve an update rate of hundreds of hertz, and no computer is needed to determine the centroid. The camera is based on a position-sensitive detector (PSD), which is a rectangular photodiode with output contacts at opposite ends. PSDs are usually used in triangulation for measuring small distances. PSDs are manufactured in both one- and two-dimensional versions. Because it is very difficult to calibrate two-dimensional PSDs accurately, the focal-plane sensors used in this camera are two orthogonally mounted one-dimensional PSDs.

Liebe, Carl↗

Seismicity and Stress Associated With a Fluid-Driven Fracture: Estimating the Evolving Geometry

A coupled approach, combining the theory of rate- and state-dependent friction and methods from poroelasticity, forms the basis for a quantitative relationship between displacements and fluid leak-off from a growing fracture and changes in the rate of seismic events in the region surrounding the fracture. Poroelastic Green's functions link fracture aperture changes and fluid flow from the fracture to changes in the stress field and pore pressure in the adjacent formation. The theory of rate- and state-dependent friction provides a connection between Coulomb stress changes and variations in the rate of seismic events. Numerical modeling indicates that the Coulomb stress changes can vary significantly between formations with differing properties. The relationship between the seismicity rate changes and the changes in the formation stresses and fluid pressure is nonlinear, but a transformation produces a quantity that is linearly related to the aperture changes and fluid leak-off from the fracture. The methodology provides a means for mapping changes in seismicity into fracture aperture changes and to image an evolving fracture. An application to observed microseismicity associated with a hydrofracture reveals asymmetric fracture propagation within two main zones, with extended propagation in the upper zone. Furthermore, the time-varying volume of the fracture agrees with the injected volume, given by the integration of rate changes at the injection well, providing validation of the estimated aperture changes.

58 GEOSCIENCES↗

NASA Tech Briefs, January 2010

Topics covered include: Cryogenic Flow Sensor; Multi-Sensor Mud Detection; Gas Flow Detection System; Mapping Capacitive Coupling Among Pixels in a Sensor Array; Fiber-Based Laser Transmitter for Oxygen A-Band Spectroscopy and Remote Sensing; Low-Profile, Dual-Wavelength, Dual-Polarized Antenna; Time-Separating Heating and Sensor Functions of Thermistors in Precision Thermal Control Applications; Cellular Reflectarray Antenna; A One-Dimensional Synthetic-Aperture Microwave Radiometer; Electrical Switching of Perovskite Thin-Film Resistors; Two-Dimensional Synthetic-Aperture Radiometer; Ethernet-Enabled Power and Communication Module for Embedded Processors; Electrically Variable Resistive Memory Devices; Improved Attachment in a Hybrid Inflatable Pressure Vessel; Electrostatic Separator for Beneficiation of Lunar Soil; Amorphous Rover; Space-Frame Antenna; Gear-Driven Turnbuckle Actuator; In-Situ Focusing Inside a Thermal Vacuum Chamber; Space-Frame Lunar Lander; Wider-Opening Dewar Flasks for Cryogenic Storage; Silicon Oxycarbide Aerogels for High-Temperature Thermal Insulation; Supercapacitor Electrolyte Solvents with Liquid Range Below -80 C; Designs and Materials for Better Coronagraph Occulting Masks; Fuel-Cell-Powered Vehicle with Hybrid Power Management; Fine-Water-Mist Multiple-Orientation-Discharge Fire Extinguisher; Fuel-Cell Water Separator; Turbulence and the Stabilization Principle; Improved Cloud Condensation Nucleus Spectrometer; Better Modeling of Electrostatic Discharge in an Insulator; Sub-Aperture Interferometers; Terahertz Mapping of Microstructure and Thickness Variations; Multiparallel Three-Dimensional Optical Microscopy; Stabilization of Phase of a Sinusoidal Signal Transmitted Over Optical Fiber; Vacuum-Compatible Wideband White Light and Laser Combiner Source System; Optical Tapers as White-Light WGM Resonators; EPR Imaging at a Few Megahertz Using SQUID Detectors; Reducing Field Distortion in Magnetic Resonance Imaging; Fluorogenic Cell-Based Biosensors for Monitoring Microbes; A Constant-Force Resistive Exercise Unit; GUI to Facilitate Research on Biological Damage from Radiation; On-Demand Urine Analyzer; More-Realistic Digital Modeling of a Human Body; and Advanced Liquid-Cooling Garment Using Highly Thermally Conductive Sheets.

Source record↗

Effects of Atmosphere and Ocean Horizontal Model Resolution on Tropical Cyclone and Upper-Ocean Response Forecasts in Four Major Hurricanes

A coupled atmosphere–ocean model is necessary for tropical cyclone (TC) prediction to accurately characterize ocean feedback on atmospheric processes within the TC environment. Here, the ECMWF coupled global model is run at horizontal resolutions from 9 to 1.4 km in the atmosphere, as well as 25 and 8 km in the ocean, to identify how resolution impacts forecast accuracy of four observed major TCs in the Atlantic: Irma, Florence, Teddy, and Ida. Most of the resolutions used here are unprecedented for global models. GOES-16 and synthetic aperture radar (SAR) satellite images and best track data are used for atmospheric validation. Salinity and temperature observations from Air-Launched Autonomous Micro-Observer (ALAMO) floats are used to validate modeled upper-ocean response, including mixed layer deepening, sea surface cooling, and near-inertial waves in the wakes of TCs. Increasing atmospheric resolution leads to more realistic TC structure and stronger winds, significantly improving TC intensity forecasts and modestly improving track errors. Ocean resolution impacts the upper-ocean response but does not influence atmospheric forecasts for the fast-moving TCs considered here. Stronger mixing, sea surface cooling, and near-inertial oscillations are found for both higher atmosphere and ocean resolutions, provided the initial upper-ocean state is the same for the two ocean resolutions. Whether this agrees better with the ALAMO observations also depends on the realism of the initial upper-ocean state in the model, emphasizing the importance of ocean initialization for the accurate upper-ocean response. Overall, the model at all resolutions correctly predicts stronger mixing, surface cooling, and near-inertial oscillation amplitudes to the right of a TC center, as observed by ALAMO floats.

Atmosphere-ocean interaction↗

Fiber optics for astronomical spectroscopy - The Medusa Spectrograph

An instrument has been built to obtain simultaneous spectra of 32 objects in the field of view of the Steward Observatory 2.3 m telescope. Short lengths of optical fiber are used to bring light from galaxy images at the focus of the telescope into a line at the spectrograph slit. This multi-fiber aperture plate instrument has been dubbed the Medusa Spectrograph. The Medusa is now producing spectra of about 100 galaxies per clear night. An optimized version of the instrument called the MX Spectrometer is being constructed to record spectra at a higher rate. This new instrument will have remotely positioned fibers under computer control. A Charge Coupled Device will be used as the spectrograph detector to allow sky subtraction, give increased dynamic range and provide more accurate wavelength calibration. Transmission characteristics of some commercial fibers are discussed, and the microlens optics used to match the telescope and the spectrograph to the fibers to avoid focal ratio degradation are described.

Hill, J. M.↗