Coulomb phase corrections to the transverse analyzing power A N ( t ) in high-energy forward proton-proton scattering
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Not Available
Not Available
Not Available
With increasing exposure to software-based sensing and control, Photovoltaic (PV) systems are facing higher risks of cyber attacks. Here, to ensure the system stability and minimize potential economic losses, it is imperative to monitor operating states and detect attacks at the early stage. To meet this demand, Micro-Phasor Measurement Units (μPMU) are increasingly popular in monitoring distribution networks. However, due to the relatively low sampling rate, μPMU has not yet been used to detect and classify cyber-attacks in power electronics enabled smart grid. To our knowledge, this is one of the first attempts to use μPMU to detect cyber attacks that degrade the performance of power electronics systems. We propose to apply data-driven methods on micro-PMU data to implement attack detection. We have evaluated data-driven methods, including decision tree (DT), K-nearest neighbor (KNN), support vector machine (SVM), artificial neural network (ANN), long short-term memory (LSTM) and convolutional neural network (CNN). The proposed CNN model achieves the required performances with the highest 99.23% accuracy and 0.9963 F 1 score.
The influx of non-linear power electronic loads into the distribution network has the potential to disrupt the existing distribution transformer operations. They were not designed to mediate the excessive heating losses generated from the harmonics. To have a good understanding of current standing challenges, a knowledge of the generation and load mix as well as the current harmonic estimations are essential for designing transformers and evaluating their performance. In this paper, we investigate a mixture of essential power electronic loads for a household designed in PSCAD/EMTdc and their potential impacts on transformer eddy current losses and derating using harmonic analysis. Our findings reveal that in the presence of high power electronic loads (especially third harmonics), increasing PV generation may worsen transformer degradation. However, with a low amount of power electronic loads, additional PV generation helps to reduce the harmonic content in the current and improve transformer performance.
The past decade has witnessed a remarkable surge in adoption of electric vehicles (EVs). The momentum is expected to continue with strong support from governments and industry. Rapid EV adoption will add significant electricity demand, making it critical to plan for and manage EV charging to avoid causing additional stress and non-negligible risks to the already-aging power grid. To help power grid operators understand the impacts of residential EV charging and identify risk factors, this study presents a data-driven charging demand analysis for light-duty vehicles. This study considers two real-world grid service regions in Colorado and merges multiple data sources and state-of-the-art tools that characterize EV adoption projections, vehicle travel patterns, seasonal variations, residential charging accessibility, ambient temperature impact, EV charging behaviors, grid utility customers, vehicle registration, and household-level EV charging demand distribution. We characterize potential residential charging demand in 2030 for two regions within the state of Colorado: Boulder and Aurora regions. We project that EVs will be 26% of the light-duty vehicle population in Boulder and 16% in Aurora areas. Charging demand is characterized for ten power grid feeders (five for each study region). Across the ten feeders, peak total EV charging powers during wintertime range from less than 1 MW to more than 4 MW.
The non-uniform distribution of inverter-based resources (IBRs) such as solar and wind energy leads to the formation of weakly coupled regions within the broader interconnection. This highlights the urgency of investigating regional dynamics. This paper proposes a practical framework for estimating regional inertia using actual event measurements from the New York (NY) region. The regional frequency is determined using measurement data from frequency disturbance recorders (FDRs) deployed across NY. The rate-of-change of frequency (RoCoF) is estimated using a hybrid methodology that combines the benefits of both moving and non-moving window techniques. By utilizing the power mismatch value and the estimated RoCoF, various inertia metrics such as regional RoCoF, inertia arrival time, and inertia percentage relative to the interconnection inertia are calculated. The identified confirmed-events that took place between 2017–2022 in NY are used in the study. This assessment of inertia using real event data reveals the true behavior of the grid under stress. The results indicate that as the generation mix in NY evolves with the rise of IBRs, both the RoCoF levels and the regional inertia undergo significant changes.
This paper explores the potential opportunities for implementing file prefetching techniques on large-scale high-performance computing (HPC) systems. Specifically, we investigate the file access patterns of various applications across multiple scientific domains using two years' worth of Darshan I/O traces obtained from the Summit supercomputer. We identify recurring trends and patterns which indicate that prefetching can be effectively leveraged to improve data access performance on HPC systems. This study serves as a valuable reference for system architects and developers in the HPC community, providing insights into the opportunities and challenges associated with enabling file prefetching on large-scale HPC systems.
Power systems around the world are undergoing a major transformation because of the increasing shares of renewable energy, growing deployment of energy storage systems, proliferation of distributed energy resources, electrification of other sectors, and so on. In the United States, wind and solar provided almost 10% of electricity in 2019. The U.S. Energy Information Administration, in its 2020 Annual Energy Outlook, forecasted that the share of electricity from renewables will reach 38% by 2050, of which more than 80% will come from wind and solar. Wind and solar, along with battery energy storage systems, interface with the grid using power electronic inverters; hence, they are collectively referred to as inverter-based resources (IBRs). The increasing annual share of electricity from IBRs in a power system means that during more times of the year, the system will operate at a much higher concentration of IBRs. Figure 1 presents the hourly share of wind and solar generation in the Electric Reliability Council of Texas (ERCOT) system in Texas in 2019. While the annual wind share was at 20%, the instantaneous percentage share was much higher. Moments of high shares of IBRs (>50%) will continue to grow as more IBRs will be deployed in a power system.
In standard silicon solar modules, cells are strung in series with bypass diodes incorporated to reduce the effects of shading. When all of the strings are partially shaded the measured short circuit current is affected and the Isc of the module will be equal to that of the lowest current cell in the least shadowed string. In bifacial modules the ability to assess losses due to shading is especially important. This paper advocates an alternative approach to converting the raw suns-voc data to pseudo IV data in modules where shading may be affecting the suns-voc curve results.
Abstract not provided.
Internet-of-Things (IoT)-based streaming applications are all around us. Currently, we are transitioning from IoT processing being performed on the cloud to the edge. While moving to the edge provides significant networking efficiency benefits, IoT edge computing creates significant data privacy concerns. We propose a methodology that can successfully privacy protect the continual data streams generated by sensors on the edge device. We implement local differential privacy on streaming data and incorporate Bayesian inference and Gaussian process to evaluate the privacy policy. We demonstrate our methodology on a real-world smart meter testbed and identify the optimal privacy protection settings.
Not Available
User-level threads have been widely adopted as a means of achieving lightweight concurrent execution without the costs of OS-level threads. Nevertheless, the costs of managing user-level threads represent a performance barrier that dictates how fine grained the concurrency exposed by an application can be without incurring significant overheads; this in turn may translate into insufficient parallelism to exploit highly parallel systems. This article is a deep dive into the fundamental costs in implementing user-level threads. We first identify that one of the highest sources of fork-join overheads stems from deviations, events that incur context switching during the execution of a thread and disrupt a run-to-completion execution. We then conduct an in-depth investigation of a wide spectrum of methods with respect to how they handle deviations while covering both parent- and child-first scheduling policies. Our methodology involves a comprehensive instruction- and cache-level analysis of all methods on several modern CPU architectures. Finally, the primary finding of our evaluation is that dynamic promotion methods that assume the absence of deviation and dynamically provide context-switching support offer the best trade-off between performance and capability when the likelihood of deviation is low.
We report kinetic energy available from the turbomachinery may boost short-term ramp rates during load shifting between generator and fuel cell that may be exploited to optimize the performance of turbine-fuel cell hybrid systems during load following. The paper starts with modeling a gas turbine, gearbox, and generator sitting on the rigid shafts as a two-mass model primarily for estimating the rotational inertia available from the turbogenerator. The gas turbine and its environment impose constraints of available space allowances, measurements from high-speed rotating parts, lack of accessibility to the shaft of measure, making replacements and/or required installation adjustments of the torque transducer difficult. It is demonstrated that in the absence of torque measurement, the data containing only a slow excursion of the rotor motion in response to a slight load change is sufficient to determine inertia and damping coefficients from the model. Furthermore, the generator’s reactive power capability was investigated because it serves as an asset in integrated hybrid systems to meet dynamic reactive power demands, reducing the burden on the fuel cell’s power electronics control in generating reactive power.
This paper seeks to inform an improved understanding of the energy tradeoff associated with on-site manufacturing water reuse in the United States from a lifecycle perspective, in part by developing an analytical framework for understanding when this tradeoff for reuse is beneficial. We survey the literature to assess the current state of reuse and its motives and barriers in the United States, before synthesizing information from publicly available EPA data on contaminants in US manufacturing wastewaters and technologies for treating them. Using the available data, we derive a set of “ubiquitous contaminants” among the top ten in terms of mass discharged in more than half of US manufacturing subsectors (NAICS 31–33) according to EPA permit data. We also present information on proven treatment trains and their energy requirements. We then compare water quality requirements for specific contaminants in reclaimed water to those characteristic of wastewater streams currently being discharged from manufacturing plants into surface waters to highlight sectors with reuse opportunities that could require little cost to realize, such as primary metals and, to a lesser extent, petroleum and coal products. We conclude by highlighting data limitations that need to be rectified before applying the framework more broadly and discussing how these data gaps could be filled. Better understanding the relationship between energy and water in the context of on-site manufacturing water reuse would allow manufacturers to improve resiliency by reducing regulatory, physical, and reputational risks while lessening their footprint on local watersheds.