At least 271 records · Page 15

Analytical Instrument

BEEM (Ballistic Electron Emission Microscopy) was invented at Jet Propulsion Laboratory's Center for Microelectronics Technology. It is a significant research instrument for microelectronics research because it is able to image underlying layers or interfaces of surface structures. A tiny current is injected into a metal layer and the electrons travel ballistically through the metal allowing the researcher to study the operation and performance of a structure. Other advantages include nondestructive imaging of barrier heights and electronic characterization of devices, as well as the potential to observe processes like molecular beam epitaxy (crystal growth) in situ.

Source record↗

Information depth in backscattered electron microscopy of nanoparticles within a solid matrix

Highlights: • Backscattered electron microscopy was used for reliable determination of nanoparticle density and sizes within Al alloys • Backscattered electron information depth was determined as a function of nanoparticle size from Monte Carlo simulations • Unlike transmission electron microscopy, the method is non-destructive and allows analyzing large sample areas • Good agreement with transmission electron microscopy data shows that our method is suitable for nanocomposite materials - Abstract: Measuring the dimensions and number density of nanoparticles dispersed in a solid matrix is usually accomplished via transmission electron microscopy (TEM) which suffers from high cost, low throughput, and small analytical volume. In comparison, scanning backscattered electron microscopy is inexpensive, requires little sample preparation, and allows for the analysis of large sample areas. However, the information depth is usually not known precisely and depends on several factors such as the composition of the nanoparticles and the matrix as well as the size of the nanoparticles, hindering the reconstruction of the actual size distribution and three-dimensional number density. Here we present a method to estimate the information depth for spherical nanoparticles of different sizes in order to accurately determine size distribution and number density. The approach is based on Monte Carlo simulation of electron trajectories in the material and analysis of the obtained backscattered electron signal-to-noise-ratio. Our experimental results are compared to those obtained via TEM and good agreement is demonstrated; this shows that TEM can be replaced by scanning electron microscopy for studying nanocomposites in many cases.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Electron Tomography: A Three-Dimensional Analytic Tool for Hard and Soft Materials Research

Three-dimensional (3D) structural analysis is essential to understand the relationship between the structure and function of an object. Many analytical techniques, such as X-ray diffraction, neutron spectroscopy, and electron microscopy imaging, are used to provide structural information. Transmission electron microscopy (TEM), one of the most popular analytic tools, has been widely used for structural analysis in both physical and biological sciences for many decades, in which 3D objects are projected into two-dimensional (2D) images. In many cases, 2D-projection images are insufficient to understand the relationship between the 3D structure and the function of nanoscale objects. Electron tomography (ET) is a technique that retrieves 3D structural information from a tilt series of 2D projections, and is gradually becoming a mature technology with sub-nanometer resolution. Distinct methods to overcome sample-based limitations have been separately developed in both physical and biological science, although they share some basic concepts of ET. Here, this review discusses the common basis for 3D characterization, and specifies difficulties and solutions regarding both hard and soft materials research. It is hoped that novel solutions based on current state-of-the-art techniques for advanced applications in hybrid matter systems can be motivated. Electron tomography produces quantitative 3D reconstructions for biological and physical sciences from sets of 2D projections acquired at different tilting angles in a transmission electron microscope. Finally, state-of-the-art techniques capable of producing 3D representations such as Pt-Pd core-shell nanoparticles and IgG1 antibody molecules are reviewed.

36 MATERIALS SCIENCE↗

Quantification of surface displacements and electromechanical phenomena via dynamic atomic force microscopy

Detection of dynamic surface displacements associated with local changes in material strain provides access to a number of phenomena and material properties. Contact resonance-enhanced methods of atomic force microscopy (AFM) have been shown capable of detecting ~1–3 pm-level surface displacements, an approach used in techniques such as piezoresponse force microscopy, atomic force acoustic microscopy, and ultrasonic force microscopy. Here, based on an analytical model of AFM cantilever vibrations, we demonstrate a guideline to quantify surface displacements with high accuracy by taking into account the cantilever shape at the first resonant contact mode, depending on the tip–sample contact stiffness. The approach has been experimentally verified and further developed for piezoresponse force microscopy (PFM) using well-defined ferroelectric materials. These results open up a way to accurate and precise measurements of surface displacement as well as piezoelectric constants at the pm-scale with nanometer spatial resolution and will allow avoiding erroneous data interpretations and measurement artifacts. Furthermore, this analysis is directly applicable to all cantilever-resonance-based scanning probe microscopy (SPM) techniques.

36 MATERIALS SCIENCE↗

Investigation of wear phenomena by microscopy

The various wear mechanisms involved in the loss of material from metallic and nonmetallic surfaces are discussed. The results presented indicate how various microscopy techniques used in conjunction with other analytical tools can assist in the elucidation of a wear mechanism. Without question, microscopy is the single most important tool for the study of the wear of surfaces, to assess and address inherent mechanisms of the material removal process.

Buckley, D. H.↗

Comparative studies of optical and elastic properties of ZrO{sub 2} thin films prepared under normal and oblique incidence deposition geometries

Oblique angle deposited optical thin films have attracted recent researcher’s interest because of their attractive optical, micro-structural, mechanical properties and more importantly because of their great potential in achieving tunability in refractive index. These properties in turn make it important in case of designing different optical devices. In the present work, ZrO{sub 2} thin films have been deposited on fused silica substrate by electron beam evaporation technique in normal as well as oblique angle deposition configurations. Optical properties, especially refractive index of the films have been estimated by fitting the measured transmission spectra with suitable theoretical dispersion models. Atomic force microscopy has been employed to characterize morphological properties of samples. The elastic properties of both the films are estimated by Atomic Force Acoustic Microscopy, a new and highly sensitive technique for thin films.

36 MATERIALS SCIENCE↗

Multimodal characterization of Te inclusions in Cd 1−x Zn x Te and Cd 1−x Zn x Te 1−y Se y for gamma and X-ray detectors

While CdZnTe (CZT) and CdZnTeSe (CZTS) semiconductors have emerged as compounds for room-temperature gamma and X-ray detection materials, they continue to be constrained by the formation of Te-inclusion defects generated during the growth and post-growth phases of the material, which adversely affect the detector performance. We demonstrate the utility of multimodal microscopic imaging and analysis for the characterization of the optical and electronic properties of Te inclusions in CZT and CZTS crystals at both micron and nanometer length scales. Having first identified regions with micron-scale Te inclusions using confocal Raman microscopy techniques, optically coupled infrared scattering near-field optical microscopic mapping was performed to map the distribution of these inclusions with nanometer spatial resolution and correlate the presence of Te inclusions in the matrix with other properties. Kelvin probe force microscopy was then utilized to characterize the variations of the work function associated with the presence of Te inclusions. Here, we observe an increase of ~ 240 mV in the work function associated with Te inclusions compared to the bulk CZT/CZTS crystals. Additionally, we observe that individual bulk grains in CZT can exhibit slight potential variations. Our findings develop a portrait of the charge trapping mechanisms in CZT and CZTS that act to degrade detector performance, while the demonstration of these combined microscopy techniques provides a new analytical tool that can be utilized for further optimization of the detector performance for these semiconducting compounds.

36 MATERIALS SCIENCE↗

Raman Microscopy Analysis of Wyoming CarbonSAFE Pilot Well Thin Sections for Mineralogy and Organic Matter Characterization

Scanning confocal Raman microspectroscopy (RMS) was used to analyze thin sections for inorganic mineral content and for evaluation of organic material (OM). Thin sections were selected from a stratigraphic test well core in the Powder River Basin, Wyoming under the Wyoming CarbonSAFE project. The well was analyzed with a variety of rock and fluid characterization techniques to determine the feasibility of a commercial-scale CO2 storage site. RMS complements other analyses, including traditional petrography, SEM, porosity and permeability, and XRD For this aspect of the study, RMS is especially important in the evaluation of OM in sealing lithologies. At prospective geologic CO2 storage sites, it is imperative to assess the unconventional oil and gas potential of seals to ensure that any future development would not compromise the integrity of the seals. Whole-slide mineralogical surveys were performed on thin sections from various shale and sandstone formations. Surveys were analyzed with Direct Classical Least Squares to identify and quantify minerals. The location and concentration of minerals was color-coded and overlaid on optical images for visualization of the distribution of minerals. Dense hyperspectral Raman mapping of OM was performed on five thin sections. Eleven spectral parameters diagnostic of organic type and thermal maturity were used to train a Partial Least Squares (PLS) calibration against a set of artificially matured samples spanning the pre- to mid-oil window. The PLS was applied to the study set and a post-mature set. Additionally, the PLS was applied to each point in hyperspectral maps for visualization of trends in maturity across sample sets and discrimination of organic matter types within a given map. In inorganic surveys on thin sections, a total of 14 unique inorganic minerals were identified in Raman spectra including quartz, dolomite, calcite, hematite and anhydrite. Shale thin sections tended to be dominated by organic material. OM was often observed mixed with inorganic minerals. Sand- and mudstones were dominated by inorganic minerals. The PLS extrapolated the post-mature set to reflectances >1.2%. The study set ranged from very immature to postmature in the median of map fit-peak parameters. However, point maturity maps indicate that matrix OM in all study samples is immature and that discreet organic particles selected for mapping, which may be inertinites, bias medians towards more-mature. The work demonstrates the capabilities of RMS to perform both whole-slide mineralogy and OM analysis with applications to formation evaluation in oil & gas, carbon sequestration and mining. Here, analysis of sealing formations in the well indicates high levels of immature organic matter that would not be a viable target for future oil production that could compromise the CO2 storage site. The work brings together diverse disciplines from geology and petrography to analytical chemistry, big data and microscopy.

Myers, Grant↗

Microstructure–Property Correlation in a Laser Powder Bed Fusion Processed High-Strength AF-9628 Steel

Laser powder bed fusion additive manufacturing (LPBF-AM) of a low-alloy, high-performance AF-9628 steel results in exceptionally high strength and good ductility. The reasons for such mechanical properties are investigated through detailed microscopy performed at several length scales. Thus, the characterization of melt pool, porosity, grain morphology, phases, and dislocations is performed in the as-printed material. The as-printed material consists of only 0.004 vol% of uniformly distributed porosity, single-phase martensitic laths with an average lath size of ≈2.5 μm, the absence of carbides indicating interstitial trapping of C atom, and high dislocation density in the martensitic laths. Experimental data through microscopy are then fed in analytical models for calculating strengthening contributions from various strengthening mechanisms. Calculated yield strength agrees well with experimentally determined value, and therefore, activation of various strengthening mechanisms is established in as-printed AF-9628.

36 MATERIALS SCIENCE↗

Microscopic Evaluation of Contaminants in Ultra-High Purity Copper

Copper is one of the very few elements having no relatively long-lived radioisotopes and which can be electrodeposited to ultra-high levels of purity. Next generation experiments probing neutrino properties and searching for direct evidence of Dark Matter require ultra-clean materials, such as copper, containing the smallest quantities obtainable of naturally occurring radioactive contaminants. Copper is also of interest in the material science field for applications requiring low-activity materials, such as in electronics and semi-conductors, an example of which is reduced alpha activity, low-fault integrated circuits. Determining the purity of the copper is of great interest, but even more important is establishing the location of any contamination and its dispersion within the bulk material. Co-deposition of contaminants during copper electrodeposition and its relationship to nucleation and growth processes were investigated using a variety of analytical methods including scanning electron microscopy (SEM), laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), and secondary ionization mass spectrometry (SIMS).

copper↗

The influence of mineralogical, chemical and physical properties on grindability of commercial clinkers with high MgO level

This research investigates various methods able to identify possible mineralogical, physical and chemical influences on the grindability of commercial clinkers with high MgO level. The aim of the study is to evaluate the hardness and elastic modulus of the clinker mineral phases and their fracture strength during the comminution processes, comparing samples from clinkers with low MgO level (0.5%) and clinkers with elevated MgO levels (> 5.0%). The study of the influence of mineralogical, chemical and physical properties was carried out using several analytical techniques, such as: optical microscopy, X-ray diffraction with Rietveld refinement (XRD) and X-ray fluorescence (XRF). These techniques were useful in qualifying the different clinker samples. The drop weight test (DWT) and the Bond ball mill grindability test were performed to characterize the mechanical properties of clinkers. Nanoindentation tests were also carried out. Results from the Bond ball mill grindability test were found to be related to the hardness of the mineral phase and to mineralogical characteristics, such as type and amount of inclusions in silicates, belite and alite crystals shape, or microcracked alites. In contrast, the results obtained by the DWT were associated to the macro characteristics of clinkers, such as porosity, as well as to the hardness and mineralogical characteristics of belite crystals in clusters. Hardness instrumented tests helped to determine the Vickers hardness and elastic modulus from the mineral phases in commercial clinkers and produced different values for the pure phases compared to previous publications.

36 MATERIALS SCIENCE↗

Micro- and nano-structural evolutions in white Portland cement/pulverized fuel ash cement pastes due to deionized-water leaching

Thin slices of white Portland cement-low calcium pulverized fuel ash (pfa) blended cement pastes containing 30 or 50% pfa were leached progressively in de-ionized water. The paste with 50% pfa was aged 13 years prior to leaching and those with 30% pfa were aged 1 and 13 years. Pastes were leached for up to 75 days and were characterized using thermal analysis, X-ray diffraction, analytical scanning and transmission electron microscopy, and solid-state nuclear magnetic resonance spectroscopy. Leaching affected the pastes in the following sequence: (i) crystals of Ca(OH){sub 2} large enough to be resolved by backscattered electron imaging were removed completely prior to any effect on C-A-S-H; (ii) the Ca/Si ratio of C-A-S-H reduced from ≈ 1.4 to ≈ 1.0 whilst the aluminosilicate structure was unaffected; (iii) further reduction in the Ca/Si ratio of C-A-S-H was accompanied by lengthening of the aluminosilicate chains; (iv) the Ca/Si ratio of C-A-S-H reduced ultimately to ≈ 0.6.

36 MATERIALS SCIENCE↗

Ultrafine Mineral Associations in Superhigh-Organic-Sulfur Kentucky Coals

Two high-organic-sulfur Kentucky coals, the eastern Kentucky River Gem coal and the western Kentucky Davis coal, are examined by scanning electron microscopy, (SEM) and transmission electron microscopy (TEM), both including elemental analysis by energy-dispersive spectroscopy (EDS). From the SEM-EDS analysis, it is observed that the western Kentucky coal had areas with Pb and Cd in addition to the expected Fe and S and the eastern Kentucky coal had individual Fe-S-rich areas with La and Ni and with Si, Al, Cr, Ni, and Ti. TEM and selected area electron diffraction (SAED) analyses demonstrate that anglesite with a rim of Pb-bearing amorphous Fe-oxide occurs in the western Kentucky coal. Melanterite, an Fe-sulfate, with minor Al, Si, and K EDS peaks, suggests that clay minerals may be in close association with the sulfate, is also detected in the coal. A polycrystalline metal in the eastern Kentucky sample with a composition similar to stainless steel is adjacent to an Al-rich shard. Euhedral pyrite grains surrounded by kaolinite and gibbsite are detected. Overall, it is noted that element associations should not be assumed to be organic just because minerals cannot be seen with optical microscopy or with standard bulk analytical techniques, such as X-ray diffraction (XRD).

organic sulfur, kentucky coals, geoscience, SEM↗