Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “acquisition function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Fast, efficient lossless data compression

This paper presents lossless data compression and decompression algorithms which can be easily implemented in software. The algorithms can be partitioned into their fundamental parts which can be implemented at various stages within a data acquisition system. This allows for efficient integration of these functions into systems at the stage where they are most applicable. The algorithms were coded in Forth to run on a Silicon Composers Single Board Computer (SBC) using the Harris RTX2000 Forth processor. The algorithms require very few system resources and operate very fast. The performance of the algorithms with the RTX enables real time data compression and decompression to be implemented for a wide range of applications.

Ross, Douglas↗

Controller for the Electronically Scanned Thinned Array Radiometer (ESTAR) instrument

A prototype controller for the ESTAR (electronically scanned thinned array radiometer) instrument has been designed and tested. It manages the operation of the digital data subsystem (DDS) and its communication with the Small Explorer data system (SEDS). Among the data processing tasks that it coordinates are FEM data acquisition, noise removal, phase alignment and correlation. Its control functions include instrument calibration and testing of two critical subsystems, the output data formatter and Walsh function generator. It is implemented in a Xilinx XC3064PC84-100 field programmable gate array (FPGA) and has a maximum clocking frequency of 10 MHz.

Zomberg, Brian G.↗

A Low-Power High-Speed Smart Sensor Design for Space Exploration Missions

A low-power high-speed smart sensor system based on a large format active pixel sensor (APS) integrated with a programmable neural processor for space exploration missions is presented. The concept of building an advanced smart sensing system is demonstrated by a system-level microchip design that is composed with an APS sensor, a programmable neural processor, and an embedded microprocessor in a SOI CMOS technology. This ultra-fast smart sensor system-on-a-chip design mimics what is inherent in biological vision systems. Moreover, it is programmable and capable of performing ultra-fast machine vision processing in all levels such as image acquisition, image fusion, image analysis, scene interpretation, and control functions. The system provides about one tera-operation-per-second computing power which is a two order-of-magnitude increase over that of state-of-the-art microcomputers. Its high performance is due to massively parallel computing structures, high data throughput rates, fast learning capabilities, and advanced VLSI system-on-a-chip implementation.

Fang, Wai-Chi↗

Network Performance Measurements for NASA's Earth Observation System

NASA's Earth Observation System (EOS) Project studies all aspects of planet Earth from space, including climate change, and ocean, ice, land, and vegetation characteristics. It consists of about 20 satellite missions over a period of about a decade. Extensive collaboration is used, both with other US. agencies (e.g., National Oceanic and Atmospheric Administration (NOA), United States Geological Survey (USGS), Department of Defense (DoD), and international agencies (e.g., European Space Agency (ESA), Japan Aerospace Exploration Agency (JAXA)), to improve cost effectiveness and obtain otherwise unavailable data. Scientific researchers are located at research institutions worldwide, primarily government research facilities and research universities. The EOS project makes extensive use of networks to support data acquisition, data production, and data distribution. Many of these functions impose requirements on the networks, including throughput and availability. In order to verify that these requirements are being met, and be pro-active in recognizing problems, NASA conducts on-going performance measurements. The purpose of this paper is to examine techniques used by NASA to measure the performance of the networks used by EOSDIS (EOS Data and Information System) and to indicate how this performance information is used.

Loiacono, Joe↗

Principles, Techniques, and Applications of Tissue Microfluidics

The principle of tissue microfluidics and its resultant techniques has been applied to cell analysis. Building microfluidics to suit a particular tissue sample would allow the rapid, reliable, inexpensive, highly parallelized, selective extraction of chosen regions of tissue for purposes of further biochemical analysis. Furthermore, the applicability of the techniques ranges beyond the described pathology application. For example, they would also allow the posing and successful answering of new sets of questions in many areas of fundamental research. The proposed integration of microfluidic techniques and tissue slice samples is called tissue microfluidics because it molds the microfluidic architectures in accordance with each particular structure of each specific tissue sample. Thus, microfluidics can be built around the tissues, following the tissue structure, or alternatively, the microfluidics can be adapted to the specific geometry of particular tissues. By contrast, the traditional approach is that microfluidic devices are structured in accordance with engineering considerations, while the biological components in applied devices are forced to comply with these engineering presets. The proposed principles represent a paradigm shift in microfluidic technology in three important ways: Microfluidic devices are to be directly integrated with, onto, or around tissue samples, in contrast to the conventional method of off-chip sample extraction followed by sample insertion in microfluidic devices. Architectural and operational principles of microfluidic devices are to be subordinated to suit specific tissue structure and needs, in contrast to the conventional method of building devices according to fluidic function alone and without regard to tissue structure. Sample acquisition from tissue is to be performed on-chip and is to be integrated with the diagnostic measurement within the same device, in contrast to the conventional method of off-chip sample prep and subsequent insertion into a diagnostic device. A more advanced form of tissue integration with microfluidics is tissue encapsulation, wherein the sample is completely encapsulated within a microfluidic device, to allow for full surface access. The immediate applications of these approaches lie with diagnostics of tissue slices and biopsy samples e.g. for cancer but the approaches would also be very useful in comparative genomics and other areas of fundamental research involving heterogeneous tissue samples.

Wade, Lawrence A.↗

Acquisition of Skill Proficiency Over Multiple Sessions of a Novel Rover Simulation

Following long-duration exploration transits, adaptive changes in sensorimotor function may impair the crew's ability to safely perform manual control tasks such as operating pressurized rovers. Postflight performance will also be influenced by the level of preflight skill proficiency they have attained. The purpose of this study was to characterize the acquisition of skills in a motion-based rover simulation over multiple sessions, and to investigate the effects of varying the simulation scenarios. METHODS: Twenty healthy subjects were tested in 5 sessions, with 1-3 days between sessions. Each session consisted of a serial presentation of 8 discrete tasks to be completed as quickly and accurately as possible. Each task consisted of 1) perspective-taking, using a map that defined a docking target, 2) navigation toward the target around a Martian outpost, and 3) docking a side hatch of the rover to a visually guided target. The simulator utilized a Stewart-type motion base (CKAS, Australia), single-seat cabin with triple scene projection covering 150 deg horizontal by 50 deg vertical, and joystick controller. Subjects were randomly assigned to a control group (tasks identical in the first 4 sessions) or a varied-practice group. The dependent variables for each task included accuracy toward the target and time to completion. RESULTS: The greatest improvements in time to completion occurred during the docking phase. The varied-practice group showed more improvement in perspective-taking accuracy. Perspective-taking accuracy was also affected by the relative orientation of the rover to the docking target. Skill acquisition was correlated with self-ratings of previous gaming experience. DISCUSSION: Varying task selection and difficulty will optimize the preflight acquisition of skills when performing novel operational tasks. Simulation of operational manual control will provide functionally relevant evidence regarding the impact of sensorimotor adaptation on early surface operations and what countermeasures are needed. Learning Objective: The use of a motion-based simulation to investigate decrements in the proficiency to operate pressurized rovers during early surface operations of space exploration missions, along with the acquisition of skill proficiency needed during the preflight phase of the mission.

Dean, S. L.↗

Mars Science Laboratory CHIMRA/IC/DRT Flight Software for Sample Acquisition and Processing

The design methodologies of using sequence diagrams, multi-process functional flow diagrams, and hierarchical state machines were successfully applied in designing three MSL (Mars Science Laboratory) flight software modules responsible for handling actuator motions of the CHIMRA (Collection and Handling for In Situ Martian Rock Analysis), IC (Inlet Covers), and DRT (Dust Removal Tool) mechanisms. The methodologies were essential to specify complex interactions with other modules, support concurrent foreground and background motions, and handle various fault protections. Studying task scenarios with multi-process functional flow diagrams yielded great insight to overall design perspectives. Since the three modules require three different levels of background motion support, the methodologies presented in this paper provide an excellent comparison. All three modules are fully operational in flight.

sample processing↗

Candidate Mission from Planet Earth control and data delivery system architecture

Using a structured, experienced-based approach, Goddard Space Flight Center (GSFC) has assessed the generic functional requirements for a lunar mission control and data delivery (CDD) system. This analysis was based on lunar mission requirements outlined in GSFC-developed user traffic models. The CDD system will facilitate data transportation among user elements, element operations, and user teams by providing functions such as data management, fault isolation, fault correction, and link acquisition. The CDD system for the lunar missions must not only satisfy lunar requirements but also facilitate and provide early development of data system technologies for Mars. Reuse and evolution of existing data systems can help to maximize system reliability and minimize cost. This paper presents a set of existing and currently planned NASA data systems that provide the basic functionality. Reuse of such systems can have an impact on mission design and significantly reduce CDD and other system development costs.

Shapiro, Phillip↗

Results from a multi-laboratory ocean metaproteomic intercomparison: effects of LC-MS acquisition and data analysis procedures

Metaproteomics is an increasingly popular methodology that provides information regarding the metabolic functions of specific microbial taxa and has potential for contributing to ocean ecology and biogeochemical studies. A blinded multi-laboratory intercomparison was conducted to assess comparability and reproducibility of taxonomic and functional results and their sensitivity to methodological variables. Euphotic zone samples from the Bermuda Atlantic Time-series Study (BATS) in the North Atlantic Ocean collected by in situ pumps and the autonomous underwater vehicle (AUV) Clio were distributed with a paired metagenome, and one-dimensional (1D) liquid chromatographic data-dependent acquisition mass spectrometry analysis was stipulated. Analysis of mass spectra from seven laboratories through a common bioinformatic pipeline identified a shared set of 1056 proteins from 1395 shared peptide constituents. Quantitative analyses showed good reproducibility: pairwise regressions of spectral counts between laboratories yielded R 2 values averaged 0.62±0.11, and a Sørensen similarity analysis of the top 1000 proteins revealed 70 %–80 % similarity between laboratory groups. Taxonomic and functional assignments showed good coherence between technical replicates and different laboratories. A bioinformatic intercomparison study, involving 10 laboratories using eight software packages, successfully identified thousands of peptides within the complex metaproteomic datasets, demonstrating the utility of these software tools for ocean metaproteomic research. Lessons learned and potential improvements in methods were described. Future efforts could examine reproducibility in deeper metaproteomes, examine accuracy in targeted absolute quantitation analyses, and develop standards for data output formats to improve data interoperability. Together, these results demonstrate the reproducibility of metaproteomic analyses and their suitability for microbial oceanography research, including integration into global-scale ocean surveys and ocean biogeochemical models.

59 BASIC BIOLOGICAL SCIENCES↗

Multispectral Microimager for Astrobiology

A primary goal of the astrobiology program is the search for fossil records. The astrobiology exploration strategy calls for the location and return of samples indicative of environments conducive to life, and that best capture and preserve biomarkers. Successfully returning samples from environments conducive to life requires two primary capabilities: (1) in situ mapping of the mineralogy in order to determine whether the desired minerals are present; and (2) nondestructive screening of samples for additional in-situ testing and/or selection for return to laboratories for more in-depth examination. Two of the most powerful identification techniques are micro-imaging and visible/infrared spectroscopy. The design and test results are presented from a compact rugged instrument that combines micro-imaging and spectroscopic capability to provide in-situ analysis, mapping, and sample screening capabilities. Accurate reflectance spectra should be a measure of reflectance as a function of wavelength only. Other compact multispectral microimagers use separate LEDs (light-emitting diodes) for each wavelength and therefore vary the angles of illumination when changing wavelengths. When observing a specularly-reflecting sample, this produces grossly inaccurate spectra due to the variation in the angle of illumination. An advanced design and test results are presented for a multispectral microimager which demonstrates two key advances relative to previous LED-based microimagers: (i) acquisition of actual reflectance spectra in which the flux is a function of wavelength only, rather than a function of both wavelength and illumination geometry; and (ii) increase in the number of spectral bands to eight bands covering a spectral range of 468 to 975 nm.

microimager↗

Filling gaps in our understanding of belowground plant traits across the world: an introduction to a Virtual Issue

The belowground world is one of the final frontiers in terrestrial ecology. The tangling of plant roots with the surrounding soil below is a lifeline for the humble forbs and towering trees above, and roots play a key role in shaping ecosystem carbon, water and nutrient cycling (Bardgett et al., 2014). Ecologists have long sought to better understand the ecosystem-scale consequences of differing plant strategies, above- and belowground, by relating plant characteristics, or traits, to plant function (Grime, 1977; Pregitzer, 2002). While developing trait–function linkages is arguably more difficult for plant traits that are hidden belowground, root and rhizosphere ecologists continue to fan out across grasslands and forests with their shovels, isotopes, and specialized cameras, seeking a better understanding of the secret lives of roots. Over the years, New Phytologist has served as a virtual town square for scientists to discuss their hard-won observations on the interplay among belowground plant traits, microbial activity, and edaphic and environmental conditions from biomes around the world (Norby & Jackson, 2000; Pregitzer, 2002; Matamala & Stover, 2013; Norby & Iversen, 2017). In this Editorial we highlight the newest papers that update and add to our understanding of the role of root and rhizosphere traits in broader ecosystem processes. We focused on papers published in New Phytologist between 1 January 2019 and 31 December 2020 and extended this window to papers still in ‘early view’ up to the time of writing. Because of the overwhelming number of papers, we did not include those with a decidedly genomic focus or that served primarily as data syntheses, reviews, insights or commentaries.

59 BASIC BIOLOGICAL SCIENCES↗

Significance of lysogeny for the metabolism of Desulfovibrio spp. strains isolated from aquatic environments of Georgia

Sulphate-reducing bacteria (SRB) are ecologically important group of anaerobic micro-organisms that can reduce sulphate to form hydrogen sulphide-a toxic gas causing iron corrosion on metal surfaces. In this work, SRB strains were isolated from aquatic environments in the country of Georgia to determine their lysogenicity and the role of temperate phages in host metabolism. SRB strains were isolated in samples from the Black Sea coast of Georgia. Based on their genetic, cytological and physiological properties of bacteria, 10 Georgian isolates were assigned to the genus Desulfovibrio. Temperate bacteriophages were induced from three out of ten strains by UV-exposure. Comparison of metal (Fe and Cr) reduction and utilization of various carbon sources by the wild-type (lysogenic) bacterial strains and their UV-irradiated counterparts was done. Temperate phage in the cells of SRB could alter significant functions of bacteria and may have a contribution in the acquisition of different traits by SRB. This article pointed to a significant role for temperate bacteriophages in the metabolism and metabolic potential of host strains of SRB, which were first isolated from the aquatic environment of Georgia.

temperate phage↗

Physical limitations in sensors for a drag-free deep space probe

The inner perturbing forces acting on sensors were analyzed, taking into account the technological limitations imposed on the proof mass position pickup and proof mass acquisition system. The resulting perturbing accelerations are evaluated as a function of the drag-free sensor parameters. Perturbations included gravitational attraction, electrical action, magnetic action, pressure effects, radiation effects, and action of the position pickup. These data can be used to study the laws of guidance, providing an optimization of the space probe as a whole.

Juillerat, R.↗

Estimating Residual Uncertainties for Lunar Irradiance Measurements Due to Imaging Acquisition Parameters

Lunar calibration is a commonly used method to track a climate satellite sensor's long-term radiometric stability. We present a modeling approach to examine the satellite sensor lunar observation uncertainties due to several important aspects related to the lunar image acquisition by the satellite sensor: lunar pixel shift, point spread function (PSF), lunar orientation, pitch, and oversampling rates. Our analyses can be summarized as follows: (1) The sensor observed lunar irradiance can vary due to small lunar pixel shift if the PSF is less than ideal; (2) During lunar calibration, an unstable oversampling rate due to spacecraft control will result in errors in observed lunar irradiance. A drift in oversampling rate would result in a bias in observed lunar irradiance and a random variation in oversampling rate would cause random error in lunar irradiance. Increasing the overall oversampling rates can reduce random error in observed lunar irradiance but would not change the biases in the observation; (3) Furthermore, the biases can vary when the Moon is observed at different orientations. Our results show impacts on observed lunar irradiance are on the order of 0.1 percent, which is a significant part of the overall uncertainty for a lunar irradiance measurement of a climate satellite sensor.

Oversampling↗

In-Lab Rapid Analytical Detection of Lunar Volatiles By Universal Gas Analyzer With Comparison to GC-MS System

Introduction: The curation of permanently shadowed regions (PSRs) [1] on the lunar surface is centered around studies based upon the observed volatiles from the LCROSS mission [2]. The rapid detection of important volatile gases and vapors present in planetary bodies and Astromaterials by a standalone analytical device is an area of intense research interest in our group and Planetary Exploration & Astromaterials Research Laboratory (PEARL) facility and this work is relevant to the future preparation of viable lunar simulants for testing curation efforts down the road. The groundbreaking results obtained from the LCROSS Mission [2] open the requirements for the direct detection of volatiles present in regolith materials collected from the lunar surface. The mass spectrometry of volatile chemicals is a general technique that utilizes a set of instruments that creates charged ions from a gaseous chemical species and measures the intensities vs. mass-to-charge ratio (m/z) [3]. In this context, we discuss in-lab experimental results and procedures for rapid qualitative analysis of main LCROSS volatiles (water, H2S, NH3, CO2, and CH3OH) by a Universal Gas Analyzer (UGA) instrument. Additionally, the instrument performance was evaluated by measuring the isotopic abundance ratio of atmospheric Ar-40 to Ar-36 present in room air since, argon is a relevant gas in planetary studies as it can provide an insight and reference point to isotope studies [4]. Additional, cross comparisons were attempted and made between the two instruments to develop a robust analytical technique by comparing mass spectral data for H2S headspace samples with a Trace-1310/ ISQ 7000 (ThermoFisher Scientific.) GC-MS system. Background: The benchtop UGA System is equipped with an SRS UGA 300 quadrupole mass spectrometer designed and built by Stanford Research Systems [5]. This system can be configured for several types of gaseous chemical analysis. The inlet line continuously samples gases at low flow rates (several milliliters per minute) through a capillary limiting the intake pressure making the instrument ideal for online analysis of select gases and/or room atmosphere. Moreover, in our current UGA system, a change in composition at the inlet can be detected in about 200 milliseconds and a complete spectrum is acquired (for a range of 1-100 amu) in under 45 sec with masses measured at rates up to 25 msec per point [5]. This system provides a quick upstream analytical data that we can then compare to results obtained by our GC-MS system. Sample Preparation: Small volume (2-4 mL) of analyte sample was taken in a 10 mL glass vial and sealed with a crimped cap and purged with pure Ar or N2 gas to displace air from the top. The headspace sample was scanned by the UGA instrument at analog, histogram, and pressure vs. time modes. The isotopic abundance ratio for 40Ar-to-36Ar was estimated by measuring partial pressure vs. time scans and setting the mass at 40 and 36 respectively. Results and Discussions: In this work, we have investigated the applicability of the UGA system by qualitative analysis of a series of LCROSS volatiles measured individually. Fig. 1 demonstrates a set of vertically offset spectra for the partial pressures measured as a function of mass-to-charge (m/z) ratios. The average acquisition time for each spectrum was less than a minute suggesting that the UGA system is ideal for quick analysis of geochemical volatiles. For the cross-comparison, we analyzed an H2S headspace sample by a Trace-1310/ISQ-7000 system and compared mass spectral data with previously measured UGA histogram scan data (Fig. 2). In both cases, major peak positions are the same, however, the intensities of fragment ions ([1H132S]+ and [32S]+) are higher for UGA suggesting that the fragment ionization process is stronger in UGA compared to that of GC-MS. To investigate how the integrated area under each chromatogram varies with the headspace sample volume, a set of five H2S headspace samples with increasing volumes was analyzed by the GC-MS system (Fig. 3, inset). A small volume (e.g., 200 to 1000 µL) of H2S/H2O vapor was withdrawn from a 20 mL stock sample vial containing ~5 mL of 0.4% H2S in water by a gas-tight syringe and added to another 20 mL vial filled with argon and analyzed by the GC-MS system. Finally, the UGA detector sensitivity was evaluated by calculating the atmospheric 40Ar-to-36Ar isotopic abundance ratio in room air by running a partial pressure vs. time scan with setting the atomic mass at 40, and 36. Fig. 4(a) shows a ~25 min duration “P vs. time” scan for 40Ar (plot for 36Ar is not shown). The partial pressure values (~100 points) were corrected by subtracting the corresponding background pressure value for 37Ar and utilized to calculate 40Ar-to-36Ar isotopic abundance ratios as shown by Fig. 4b. The average isotopic abundance ratio is ~306 with a 2*STDEV ~13. This abundance ratio is significantly close to the previously reported value of 298.56 [6] and the ratio obtained by our GC-MS system (303 for a UHP grade Ar sample). Conclusions: Our study strongly evidenced that the benchtop UGA system is a valuable analytical tool for the detection of major LCROSS volatiles. The rapid scanning capability, the inexpensiveness of the whole system, and impressive detection sensitivity prove its worthiness as an essential device for advanced geochemical applications. Moreover, cross comparisons with the GC-MS provide important bridges into advanced curatorial efforts into the future. References: [1] Bickel, V.T., et al. (2021) Nat Commun 12, 5607. [2] Colaprete, A., et al. (2010) Science, 330, 463-468. [3] Glavin, D. P. et al. (2012) 2012 IEEE Aerospace Conference, 1-11. [4] Willett, C. D., et al. (2022) Geochimica et Cosmochimica Acta 329, 119-134. [5] Operation Manual and Programming Reference. (2018) Universal gas Analyzers, Stanford Research Systems. [6] Lee, J. Y., et al. (2006) Geochimica et Cosmochimica Acta 70, 4507–4512. Notes: (4 figures are attached with text as shown by the attached file)

Curation↗

Evidence for a genetic basis in functional trait tradeoffs with microbial growth rate but not growth yield

Tradeoffs in microbial functional traits have been a focus of recently described ecological frameworks and of mathematical models of microbial community functioning. Tradeoffs in key traits such as growth rate, growth yield, resource acquisition, and stress tolerance may have either a genetic basis or a physiological basis, and the type of tradeoff can inform how traits are modeled and measured. Here we provide evidence that growth rate/decomposition and growth rate/stress tolerance tradeoffs have a primarily genetic basis in a phylogenetically diverse suite of ten leaf litter-inhabiting fungi. In contrast, growth yield tradeoffs with functional traits are more likely to have a physiological basis. Consideration of the type of tradeoff, genetic or physiological, should help to inform efforts to model microbial contributions to ecosystem processes, especially when considering different scales. Consideration of physiological tradeoffs may be important for understanding short-term variability (e.g., pulse events) and fine spatial scales, whereas genetic tradeoffs are likely to be useful for understanding regional- to continental-scale and medium- to long-term contributions of microbes to ecosystem processes.

59 BASIC BIOLOGICAL SCIENCES↗