Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “acceptance sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Analysis of Harrell Monosodium Titanate Lot #071311

Monosodium titanate (MST) for use in the Actinide Removal Process (ARP) must be qualified and verified in advance. A single qualification sample for each batch of material is sent to SRNL for analysis, as well as a statistical sampling of verification samples. The Harrell Industries Lot No.071311 qualification and 12 verification samples met all the requirements in the specification indicating the material is acceptable for use in the process.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization Results for the September 2023 Tank Farm 3H Evaporator Overhead Sample

On an annual basis, Savannah River Mission Completion (SRMC) provides 2H and 3H evaporator overhead samples to Savannah River National Lab (SRNL) to be analyzed per Section 5.2 of the Effluent Treatment Project (ETP) Waste Compliance Plan (WCP) and the Waste Acceptance Criteria (WAC). This report presents the average characterization results for the September 2023 3H evaporator overhead sample. The sample was clear and colorless with no visible solids. The results provide measurements for cesium-137 ( 137 Cs), strontium-90 ( 90 Sr), and iodine-129 ( 129 I) with the radionuclide concentration limits specified by the WAC. These analyses were performed in duplicate, and all three measured radionuclide concentrations were within ETP WAC limits. A summary of the analytical results for this 3H evaporator overhead sample includes the following: The measured cesium-137 activity in the 3H evaporator overhead sample averaged 5.70E+01 dpm/mL, which is below the ETP WAC limit of 1.30E+03 dpm/mL. As seen through historical results, Cs-137 continues to present a decreasing activity since 2020. The strontium-90 activity in the 3H evaporator overhead sample averaged <2.16E00 dpm/mL, which is below the ETP WAC limit of 1.76E+02 dpm/mL. The iodine-129 activity in the 3H evaporator overhead sample averaged <9.08E-02 dpm/mL, which is below the ETP WAC limit of 1.00E+00 dpm/mL

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extraction efficiency and implications for absolute quantitation of propranolol in mouse brain, liver and kidney thin tissue sections using droplet-based liquid microjunction surface sampling-HPLC ESI-MS/MS

Currently, absolute quantitation aspects of droplet-based surface sampling for thin tissue analysis using a fully automated autosampler/HPLC-ESI-MS/MS system are not fully evaluated. Knowledge of extraction efficiency and its reproducibility is required to judge the potential of the method for absolute quantitation of analytes from thin tissue sections. Methods: Adjacent thin tissue sections of propranolol dosed mouse brain (10- μm-thick), kidney (10- μm-thick) and liver (8-, 10-, 16- and 24- μm-thick) were obtained. Absolute concentration of propranolol was determined in tissue punches from serial sections using standard bulk tissue extraction protocols and subsequent HPLC separations and tandem mass spectrometric analysis. These values were used to determine propranolol extraction efficiency from the tissues with the droplet-based surface sampling approach. Results: Extraction efficiency of propranolol using 10- μm-thick brain, kidney and liver thin tissues using droplet-based surface sampling varied between ~45-63%. Extraction efficiency decreased from ~65% to ~36% with liver thickness increasing from 8 μm to 24 μm. Randomly selecting half of the samples as standards, precision and accuracy of propranolol concentrations obtained for the other half of samples as quality control metrics were determined. Resulting precision ( ±15%) and accuracy ( ±3%) values, respectively, were within acceptable limits. In conclusion, comparative quantitation of adjacent mouse thin tissue sections of different organs and of various thicknesses by droplet-based surface sampling and by bulk extraction of tissue punches showed that extraction efficiency was incomplete using the former method, and that it depended on the organ and tissue thickness. However, once extraction efficiency was determined and applied, the droplet-based approach provided the required quantitation accuracy and precision for assay validations. Furthermore, this means that once the extraction efficiency was calibrated for a given tissue type and drug, the droplet-based approach provides a non-labor intensive and high-throughput means to acquire spatially resolved quantitative analysis of multiple samples of the same type.

59 BASIC BIOLOGICAL SCIENCES↗

Comparing vis–NIRS, LIBS, and Combined vis–NIRS‐LIBS for Intact Soil Core Soil Carbon Measurement

Core Ideas First rigorous integration of VisNIR and LIBS spectroscopic techniques for soil profile C measurement. Field‐moist intact soil cores scanned with LIBS and VisNIR simulating in situ measurements. Combined VisNIR‐LIBS wavelengths selected by MRCE were split nearly equally between sensors, suggesting molecular and elemental information was successfully integrated for predicting TC, IC, and SOC. Stoichiometric relationships in LIBS elemental emissions are more strongly correlated to IC concentration than were carbonate absorptions in VisNIR. Lack of variation and consistent, definable chemical composition and stoichiometry likely contributed to poor LIBS and combined VisNIR – LIBS prediction accuracy for SOC. Soil organic carbon (SOC) measurement is critically important to quantify regional and global soil C stocks and better understand soil C biogeochemical processes. Recent studies employing laser‐induced breakdown spectroscopy (LIBS) and visible‐near infrared diffuse reflectance spectroscopy (vis–NIRS) indicate their potential for in situ soil C determination. Visible and near infrared diffuse reflectance spectroscopy and LIBS spectroscopy fundamentally differ and we hypothesize that their integration would provide improved soil C predictions. We report the first rigorous integration of vis–NIRS and LIBS, evaluating the precision of vis–NIRS, LIBS, and combined vis–NIRS‐LIBS spectra for simulated in situ soil profile total C (TC), inorganic C (IC) and SOC measurement. Three multivariate variable selection and regression approaches were evaluated for soil C prediction. The highest soil C prediction accuracies were observed using multivariate regression with covariance estimation (MRCE). Inorganic C was best predicted by LIBS, vis–NIRS provided better SOC predictions, and TC was best predicted using combined vis–NIRS‐LIBS data. Combined vis–NIRS‐LIBS did not consistently increase soil C prediction accuracy. Soil organic C was not well predicted, presumably due to challenges associated with scanning surfaces of intact soil cores, variable SOC chemistries, and low SOC variation in the dataset. Considering the challenging conditions under which combined vis–NIRS– LIBS was tested for soil C measurement, data integration and model calibrations had acceptable performance. Further testing under more controlled soil conditions with samples containing greater SOC diversity is necessary to determine the technical potential of combined vis–NIRS/LIBS for soil C determination.

Bricklemyer, Ross S.↗

Underground Test Area Calendar Year 2014 Annual Sampling Analysis Report Nevada National Security Site, Nevada, Revision 0

This report presents the analytical data for the 2014 fiscal year (FY) and calendar year (CY) (October 1, 2013, through December 31, 2014), and an evaluation of the data to ensure that the Sampling Plan’s objectives are met. In addition to samples collected and analyzed for the Sampling Plan, some NNSS wells are monitored by NNSA/NFO to demonstrate compliance with State-issued water discharge permits; with protection of groundwater from ongoing radiological waste disposal activities (compliance wells); and to demonstrate that the onsite drinking water supply is below SDWA maximum contaminant levels (MCLs) (public water system [PWS] wells). While not all sampled locations are required by the Sampling Plan, these samples are relevant to its objectives and are therefore presented herein for completeness purposes. Special investigations that took place in 2014 that are relevant to the Sampling Plan are also presented. This is the first annual report released to support Sampling Plan implementation.

54 ENVIRONMENTAL SCIENCES↗

Commercial Off-the-Shelf (COTS) Components and Enterprise Component Information System (eCIS)

The purpose of the project was to develop the processes for using commercial off-the-shelf (COTS) parts for WR production and to put in place a system for implementing the data management tools required to disseminate, store, track procurement, and qualify vendors. Much of the effort was devoted to determining if the use of COTS parts was possible. A basic question: How does the Nuclear Weapons Complex (NWC) begin to use COTS in the weapon Stockpile Life Extension Programs with high reliability, affordability, while managing risk at acceptable levels? In FY00, it was determined that a certain weapon refurbishment program could not be accomplished without the use of COTS components. The elements driving the use of COTS components included decreased cost, greater availability, and shorter delivery time. Key factors that required implementation included identifying the best suppliers and components, defining life cycles and predictions of obsolescence, testing the feasibility of using COTS components with a test contractor to ensure capability, as well as quality and reliability, and implementing the data management tools required to disseminate, store, track procurement, and qualify vendors. The primary effort of this project then was to concentrate on the risks involved in the use of COTS and address the issues of part and vendor selection, procurement and acceptance processes, and qualification of the parts via part and sample testing. The Enterprise Component Information System (eCIS) was used to manage the information generated by the COTS process. eCIS is a common interface for both the design and production of NWC components and systems integrating information between SNL National Laboratory (SNL) and the Kansas City Plant (KCP). The implementation of COTS components utilizes eCIS from part selection through qualification release. All part related data is linked across an unclassified network for access by both SNL and KCP personnel. The system includes not only NWC part information but also includes technical reference data for over 25 Million electronic and electromechanical commercial and military parts via a data subscription. With the capabilities added to the system through this project, eCIS provides decision support, parts list/BOM analysis, editing, tracking, workflows, reporting, and history/legacy information integrating manufacturer reference, company technical, company business, and design data.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Characterization Results for the August 2025 Tank Farm 2H Evaporator Overhead Sample

On an annual basis, Savannah River Mission Completion (SRMC) provides 2H and 3H evaporator overhead samples to Savannah River National Lab (SRNL) to be analyzed per Section 5.2 of the Effluent Treatment Project (ETP) Waste Compliance Plan (WCP) and the Waste Acceptance Criteria (WAC). This report presents the average characterization results for the August 2025 2H evaporator overhead sample. The sample was clear and colorless with no visible solids. The results provide measurements for cesium-137 ( 137 Cs), strontium-90 ( 90 Sr), and iodine-129 ( 129 I) with the radionuclide concentration limits specified by the WAC. These analyses were performed in duplicate, and all three measured radionuclide concentrations were within ETP WAC limits. A summary of the analytical results for this 2H evaporator overhead sample includes the following: The measured cesium-137 activity in the 2H evaporator overhead sample averaged 3.02E+02 dpm/mL, which is below the ETP WAC limit of 1.30E+03 dpm/mL. The strontium-90 activity in the 2H evaporator overhead sample averaged 3.33E+00 dpm/mL, which is below the ETP WAC limit of 1.76E+02 dpm/mL. The iodine-129 activity in the 2H evaporator overhead sample averaged 1.20E-01 dpm/mL, which is below the ETP WAC limit of 1.00E+00 dpm/mL. Although the measurements for Cs-137 and Sr-90 are lower compared to previous years, the results remain within a similar range to past measurements and are well below the WAC limits. Iodine-129 indicates detectable results compared to previous years, which can be attributed to recent salt batch processing trending close to the WAC limit for saltstone production. However, these results are still below the ETP WAC limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Decommissioning the Fuel Process Building, a Shift in Paradigm for Terminating Safeguards on Process Holdup

INMM Abstract 51st Annual Meeting Decommissioning the Fuel Process Building, a Shift in Paradigm for Terminating Safeguards on Process Holdup The Fuel Process Building at the Idaho Nuclear Technology and Engineering Center (INTEC) is being decommissioned after nearly four decades of recovering high enriched uranium from various government owned spent nuclear fuels. The separations process began with fuel dissolution in one of multiple head-ends, followed by three cycles of uranium solvent extraction, and ending with denitration of uranyl nitrate product. The entire process was very complex, and the associated equipment formed an extensive maze of vessels, pumps, piping, and instrumentation within several layers of operating corridors and process cells. Despite formal flushing and cleanout procedures, an accurate accounting for the residual uranium held up in process equipment over extended years of operation, presented a daunting safeguards challenge. Upon cessation of domestic reprocessing, the holdup remained inaccessible and was exempt from measurement during ensuing physical inventories. In decommissioning the Fuel Process Building, the Idaho Cleanup Project, which operates the INTEC, deviated from the established requirements that all nuclear material holdup be measured and credited to the accountability books and that all nuclear materials, except attractiveness level E residual holdup, be transferred to another facility. Instead, the decommissioning involved grouting the process equipment in place, rather than measuring and removing the contained holdup for subsequent transfer. The grouting made the potentially attractiveness level C and D holdup even more inaccessible, thereby effectually converting the holdup to attractiveness level E and allowing for termination of safeguards controls. Prior to grouting the facility, the residual holdup was estimated by limited sampling and destructive analysis of solutions in process lines and by acceptable knowledge based upon the separations process, plant layout, and operating history. The use of engineering estimates, in lieu of approved measurement methods, was justified by the estimated small quantity of holdup remaining, the infeasibility of measuring the holdup in a highly radioactive background, and the perceived hazards to personnel. The alternate approach to quantifying and terminating safeguards on process holdup was approved by deviation.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Quantifying Contaminant Mass for the Feasibility Study of the DuPont Chambers Works FUSRAP Site - 13510

The U.S. Army Corps of Engineers (USACE) - Philadelphia District is conducting an environmental restoration at the DuPont Chambers Works in Deepwater, New Jersey under the Formerly Utilized Sites Remedial Action Program (FUSRAP). Discrete locations are contaminated with natural uranium, thorium-230 and radium-226. The USACE is proposing a preferred remedial alternative consisting of excavation and offsite disposal to address soil contamination followed by monitored natural attenuation to address residual groundwater contamination. Methods were developed to quantify the error associated with contaminant volume estimates and use mass balance calculations of the uranium plume to estimate the removal efficiency of the proposed alternative. During the remedial investigation, the USACE collected approximately 500 soil samples at various depths. As the first step of contaminant mass estimation, soil analytical data was segmented into several depth intervals. Second, using contouring software, analytical data for each depth interval was contoured to determine lateral extent of contamination. Six different contouring algorithms were used to generate alternative interpretations of the lateral extent of the soil contamination. Finally, geographical information system software was used to produce a three dimensional model in order to present both lateral and vertical extent of the soil contamination and to estimate the volume of impacted soil for each depth interval. The average soil volume from all six contouring methods was used to determine the estimated volume of impacted soil. This method also allowed an estimate of a standard deviation of the waste volume estimate. It was determined that the margin of error for the method was plus or minus 17% of the waste volume, which is within the acceptable construction contingency for cost estimation. USACE collected approximately 190 groundwater samples from 40 monitor wells. It is expected that excavation and disposal of contaminated soil will remove the contaminant source zone and significantly reduce contaminant concentrations in groundwater. To test this assumption, a mass balance evaluation was performed to estimate the amount of dissolved uranium that would remain in the groundwater after completion of soil excavation. As part of this evaluation, average groundwater concentrations for the pre-excavation and post-excavation aquifer plume area were calculated to determine the percentage of plume removed during excavation activities. In addition, the volume of the plume removed during excavation dewatering was estimated. The results of the evaluation show that approximately 98% of the aqueous uranium would be removed during the excavation phase. The USACE expects that residual levels of contamination will remain in groundwater after excavation of soil but at levels well suited for the selection of excavation combined with monitored natural attenuation as a preferred alternative. (authors)

54 ENVIRONMENTAL SCIENCES↗

TU-AB-BRC-11: Moving a GPU-OpenCL-Based Monte Carlo (MC) Dose Engine Towards Routine Clinical Use: Automatic Beam Commissioning and Efficient Source Sampling

Purpose: We have previously developed a GPU-OpenCL-based MC dose engine named goMC with built-in analytical linac beam model. To move goMC towards routine clinical use, we have developed an automatic beam-commissioning method, and an efficient source sampling strategy to facilitate dose calculations for real treatment plans. Methods: Our commissioning method is to automatically adjust the relative weights among the sub-sources, through an optimization process minimizing the discrepancies between calculated dose and measurements. Six models built for Varian Truebeam linac photon beams (6MV, 10MV, 15MV, 18MV, 6MVFFF, 10MVFFF) were commissioned using measurement data acquired at our institution. To facilitate dose calculations for real treatment plans, we employed inverse sampling method to efficiently incorporate MLC leaf-sequencing into source sampling. Specifically, instead of sampling source particles control-point by control-point and rejecting the particles blocked by MLC, we assigned a control-point index to each sampled source particle, according to MLC leaf-open duration of each control-point at the pixel where the particle intersects the iso-center plane. Results: Our auto-commissioning method decreased distance-to-agreement (DTA) of depth dose at build-up regions by 36.2% averagely, making it within 1mm. Lateral profiles were better matched for all beams, with biggest improvement found at 15MV for which root-mean-square difference was reduced from 1.44% to 0.50%. Maximum differences of output factors were reduced to less than 0.7% for all beams, with largest decrease being from1.70% to 0.37% found at 10FFF. Our new sampling strategy was tested on a Head&Neck VMAT patient case. Achieving clinically acceptable accuracy, the new strategy could reduce the required history number by a factor of ∼2.8 given a statistical uncertainty level and hence achieve a similar speed-up factor. Conclusion: Our studies have demonstrated the feasibility and effectiveness of our auto-commissioning approach and new efficient source sampling strategy, implying the potential of our GPU-based MC dose engine goMC for routine clinical use.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fiberboard Properties and Degradation Rates for Storage of 9975 Shipping Package in KAC (2020 Status Report)

Savannah River Site (SRS) stores plutonium materials within model 9975 shipping packages in the K-Area Complex (KAC). The 9975 shipping package consists of a 35 gallon stainless steel drum, Celotex fiberboard insulation, lead shield, and primary and secondary containment vessels. The 9975 shipping package design, performance, and analysis for safe transport of radioactive material are described in the Safety Analysis Report for Packaging (SARP). Celotex fiberboard provides three safety functions: thermal insulation to limit internal temperature during a fire, criticality control, and resistance to package crushing. The fiberboard material must retain its dimensions and density within certain ranges to provide the required impact resistance, criticality control, and fire resistance. The SRS Surveillance Program monitors material performance to establish a basis for service life and ensures the continued integrity of 9975 packages. Fiberboard samples, taken from multiple fiberboard assemblies fabricated from cane and softwood fiberboard, have been conditioning in elevated temperature environments since 2005. The samples are periodically examined to monitor thermal, mechanical, and physical properties, and assess degradation trends. Fiberboard properties of interest that are evaluated to demonstrate acceptable long-term performance include dimensional stability, density, compressive strength, thermal conductivity, and specific heat capacity. Duplicate samples from multiple package sources have been tested to identify the range of variability in fiberboard properties and degradation rates. Baseline and long-term testing of fiberboard material properties have been reported previously; reference 6 summarized experimental results of cane and softwood fiberboard through May 2019 and presented degradation models for the measured properties. This report presents the cumulative data collected through June 2020 and the corresponding updated aging models.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multiple-time-stepping generalized hybrid Monte Carlo methods

Performance of the generalized shadow hybrid Monte Carlo (GSHMC) method [1], which proved to be superior in sampling efficiency over its predecessors [2–4], molecular dynamics and hybrid Monte Carlo, can be further improved by combining it with multi-time-stepping (MTS) and mollification of slow forces. We demonstrate that the comparatively simple modifications of the method not only lead to better performance of GSHMC itself but also allow for beating the best performed methods, which use the similar force splitting schemes. In addition we show that the same ideas can be successfully applied to the conventional generalized hybrid Monte Carlo method (GHMC). The resulting methods, MTS-GHMC and MTS-GSHMC, provide accurate reproduction of thermodynamic and dynamical properties, exact temperature control during simulation and computational robustness and efficiency. MTS-GHMC uses a generalized momentum update to achieve weak stochastic stabilization to the molecular dynamics (MD) integrator. MTS-GSHMC adds the use of a shadow (modified) Hamiltonian to filter the MD trajectories in the HMC scheme. We introduce a new shadow Hamiltonian formulation adapted to force-splitting methods. The use of such Hamiltonians improves the acceptance rate of trajectories and has a strong impact on the sampling efficiency of the method. Both methods were implemented in the open-source MD package ProtoMol and were tested on a water and a protein systems. Results were compared to those obtained using a Langevin Molly (LM) method [5] on the same systems. The test results demonstrate the superiority of the new methods over LM in terms of stability, accuracy and sampling efficiency. This suggests that putting the MTS approach in the framework of hybrid Monte Carlo and using the natural stochasticity offered by the generalized hybrid Monte Carlo lead to improving stability of MTS and allow for achieving larger step sizes in the simulation of complex systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

RadICalc. A program for estimating radiation intensity of radionuclide mixtures

RadICalc is a cross-platform program designed to calculate the intensity of radiation released by the decay of arbitrary isotopic mixtures. It was developed to address the need for a program that could calculate the composition, activity, and measurable radiation of a sample over time without significant effort from end-users. RadICalc uses Bateman's solutions for radioactive decay to determine activity over time. Radiation intensities are subsequently calculated using a database containing information about alpha particles, beta electrons, gamma- rays, conversion and Auger electrons, and X-rays. The user interface accepts input for isotopic mixture, initial number of atoms, and time passed since sample composition was known. Results are plotted graphically, and there is a search interface provided to and isotopes of interest. RadICalc can determine activity and radiation expected at specific masses with user-defined molecules in addition to atomic species; the latter is useful in mass based isotope separations for radiometric counting applications, a novel method under development at PNNL.

97 MATHEMATICS AND COMPUTING↗

Treatment of Bottled Liquid Waste During Remediation of the Hanford 618-10 Burial Ground - 13001

A problematic waste form encountered during remediation of the Hanford Site 618-10 burial ground consists of bottled aqueous waste potentially contaminated with regulated metals. The liquid waste requires stabilization prior to landfill disposal. Prior remediation activities at other Hanford burial grounds resulted in a standard process for sampling and analyzing liquid waste using manual methods. Due to the highly dispersible characteristics of alpha contamination, and the potential for shock sensitive chemicals, a different method for bottle processing was needed for the 618-10 burial ground. Discussions with the United States Department of Energy (DOE) and United States Environmental Protection Agency (EPA) led to development of a modified approach. The modified approach involves treatment of liquid waste in bottles, up to one gallon per bottle, in a tray or box within the excavation of the remediation site. Bottles are placed in the box, covered with soil and fixative, crushed, and mixed with a Portland cement grout. The potential hazards of the liquid waste preclude sampling prior to treatment. Post treatment verification sampling is performed to demonstrate compliance with land disposal restrictions and disposal facility acceptance criteria. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization results for the 2020 tank farm 2H and 3H evaporator overhead samples

The 2020 annual 2H and 3H Evaporator overhead samples were received at Savannah River National Laboratory (SRNL) on December 22, 2020. The delivered samples were analyzed for concentration of cesium-137 ( 137 Cs), strontium-90 (90 Sr) and iodine-129 ( 129 I) to validate compliance with the Effluent Treatment Project Waste Acceptance Criteria (ETP WAC, Rev. 7). The concentration of all three radionuclides, 137 Cs, 90 Sr, and 129 I, in the 2H Evaporator overhead sample were found to be less than the corresponding ETP WAC limits. Radiochemical analysis of the 3H Evaporator overhead sample indicated a 137 Cs content about an order of magnitude higher than the acceptable threshold value, and 90 Sr and 129 I concentrations within the acceptance limits.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Applications of Hyporheic Zone Sampling for Assessing VOC Plume Engineered Remediation and Natural Attenuation Effectiveness - 20414

Determining the efficacy of engineered remedial actions and/or natural attenuation as an acceptable EPA Record of Decision (ROD) must address long-term temporal and spatial variability. Since final plume downslope destinations are aquifers and related surface streams and rivers, hyporheic zone sampling is essential. Comprehensive hyporheic sampling documents plume groundwater remediation prior to upwelling into stream benthic strata and natural attenuation within this dynamic zone itself. Our intensive sampling of the Savannah River Site (SRS) Chemical, Metals, and Pesticides (CMP) Pits VOC plume-fringe from 2005 to 2018 documented PCE natural attenuation and effectiveness of In Situ Thermal Treatment (ISTT). Most plume hyporheic upwelling was delimited to a 20 m inflow reach along Pen Branch. Our study utilized corroborative sampling methodologies: ambient hole-water grab samples: passive diffusion bags (PDB); and hole-core sediment samples to confirm station to station spatial and temporal trends. VOC hot spot detections were confirmed from both groundwater and soil core samples. VOC pathways through the Pen Branch hyporheic zone were assessed at hole-installation using sequential soil samples from augered cores and grab-samples of hole-bottom water. Longer term, composite water samples were collected from PDBs deployed for a minimum two-week equilibration period. Soil samples were collected from the 15 and 65 cm core levels in December 2017 and June 2018 at six stations. Additional core depths of 40 and 85 cm were sampled in June 2018 at the highest VOC station (5DB80). All samples were analyzed in an EPA certified lab by purge and trap GC-MS. Effectiveness of previous ISTT and soil vapor extraction (SVE) for this CMP Pits PCE plume, was clearly documented by significant downward trends in VOC at hyporheic zone stations prior to December 2015. Achieving final stage conversions of PCE daughter products to ethene and CO{sub 2} may be limited depending upon suitable interactions between hyporheic zone sediment morphology, hydrology, and redox conditions. Because declines in VOC daughter products at our hyporheic stations may also be caused by physical actions of dilution and dispersion rather than true biochemical dechlorination, full quantification of natural attenuation requires the use of compound-specific isotope ratio analysis (CSIA) and microbial 16S rRNA with qPCR. To assist these next-phase efforts, a natural attenuation index (NAI) was used to help produce quicker, more cost-effective decision making for locating CSIA and microbial sampling efforts. The NAI used natural logarithm transformed GC-MS results for station VOC degradation compounds versus VOC parent compounds. Wide differences were observed between stations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SLUDGE BATCH 7B QUALIFICATION ACTIVITIES WITH SRS TANK FARM SLUDGE

Waste Solidification Engineering (WSE) has requested that characterization and a radioactive demonstration of the next batch of sludge slurry - Sludge Batch 7b (SB7b) - be completed in the Shielded Cells Facility of the Savannah River National Laboratory (SRNL) via a Technical Task Request (TTR). This characterization and demonstration, or sludge batch qualification process, is required prior to transfer of the sludge from Tank 51 to the Defense Waste Processing Facility (DWPF) feed tank (Tank 40). The current WSE practice is to prepare sludge batches in Tank 51 by transferring sludge from other tanks. Discharges of nuclear materials from H Canyon are often added to Tank 51 during sludge batch preparation. The sludge is washed and transferred to Tank 40, the current DWPF feed tank. Prior to transfer of Tank 51 to Tank 40, SRNL typically simulates the Tank Farm and DWPF processes with a Tank 51 sample (referred to as the qualification sample). With the tight schedule constraints for SB7b and the potential need for caustic addition to allow for an acceptable glass processing window, the qualification for SB7b was approached differently than past batches. For SB7b, SRNL prepared a Tank 51 and a Tank 40 sample for qualification. SRNL did not receive the qualification sample from Tank 51 nor did it simulate all of the Tank Farm washing and decanting operations. Instead, SRNL prepared a Tank 51 SB7b sample from samples of Tank 7 and Tank 51, along with a wash solution to adjust the supernatant composition to the final SB7b Tank 51 Tank Farm projections. SRNL then prepared a sample to represent SB7b in Tank 40 by combining portions of the SRNL-prepared Tank 51 SB7b sample and a Tank 40 Sludge Batch 7a (SB7a) sample. The blended sample was 71% Tank 40 (SB7a) and 29% Tank 7/Tank 51 on an insoluble solids basis. This sample is referred to as the SB7b Qualification Sample. The blend represented the highest projected Tank 40 heel (as of May 25, 2011), and thus, the highest projected noble metals content for SB7b. Characterization was performed on the Tank 51 SB7b samples and SRNL performed DWPF simulations using the Tank 40 SB7b material. This report documents: (1) The preparation and characterization of the Tank 51 SB7b and Tank 40 SB7b samples. (2) The performance of a DWPF Chemical Process Cell (CPC) simulation using the SB7b Tank 40 sample. The simulation included a Sludge Receipt and Adjustment Tank (SRAT) cycle, where acid was added to the sludge to destroy nitrite and reduce mercury, and a Slurry Mix Evaporator (SME) cycle, where glass frit was added to the sludge in preparation for vitrification. The SME cycle also included replication of five canister decontamination additions and concentrations. Processing parameters were based on work with a nonradioactive simulant. (3) Vitrification of a portion of the SME product and characterization and durability testing (as measured by the Product Consistency Test (PCT)) of the resulting glass. (4) Rheology measurements of the SRAT receipt, SRAT product, and SME product. This program was controlled by a Task Technical and Quality Assurance Plan (TTQAP), and analyses were guided by an Analytical Study Plan. This work is Technical Baseline Research and Development (R&D) for the DWPF. It should be noted that much of the data in this document has been published in interoffice memoranda. The intent of this technical report is bring all of the SB7b related data together in a single permanent record and to discuss the overall aspects of SB7b processing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermoluminescence (TL) Analysis and Fading Studies of Naturally Occurring Salt Irradiated by 500 mGy Gamma Rays

The aim of the present study was to investigate the potential of the naturally occurring salt for the dosimetry purposes, using TL. The fine powder samples (20 mg) were irradiated by {gamma}- rays from 500 mGy to 2500 mGy by using Theratron-780C Cobalt-60 source, however, this paper discusses about 500 mGy only. The TL glow curve peak parameters were studied by using Chen's peak shape equation. TL glow curves were compared with fitted curves using glow curve deconvolution (GCD) method by using Kitis expression. The kinetic parameter values (E, b and s) so calculated, are in good agreement with those available in literature. The calculated energy values were also verified by using various heating rate (VHR) method. {chi}{sup 2} test and figure of merit (FOM) calculation was done to accept the goodness of fit between the curves. Fading studies of the sample showed a good fitting between the curves. The analysis suggests that natural salt should be considered for dosimetry purposes.

36 MATERIALS SCIENCE↗