Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accelerated beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Influence of additional neutrons on the fusion cross section beyond the N = 8 shell

Fusion enhancement for neutron-rich isotopes of oxygen on carbon nuclei was probed. To measure the fusion cross-section a 20O beam accelerated to E lab /A = 2.7 MeV bombarded the active-target detector MuSIC@Indiana with a fill gas of CH 4 . Examination of the average fusion cross-section over the interval 0.5 ≤ (E c.m. –V B )/V B ≤ 1.2 for 16–20 O + 12 C reveals that while even isotopes of oxygen exhibit essentially the same cross-section, the cross-section for odd isotopes can be either enhanced or suppressed relative to the even A members of the isotopic chain. Theoretical models fail to explain the observed experimental results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Resonance Control System for the PIP-II IT HWR Cryomodule

The HWR (half-wave-resonator) cryomodule is the first one in the superconducting section of the PIP-II LINAC project at Fermilab. PIP-II IT is a test facility for the project where the injector, warm front-end, and the first two superconducting cryomodules are being tested. The HWR cryomodule comprises 8 cavities operating at a frequency of 162.5 MHz and accelerating beam up to 10 MeV. Resonance control of the cavities is performed with a pneumatically operated slow tuner which compresses the cavity at the beam ports. Helium gas pressure in a bellows mounted to an end wall of the cavity is controlled by two solenoid valves, one on the pressure side and one on the vacuum side. The resonant frequency of the cavity can be controlled in one of two modes. A pressure feedback control loop can hold the cavity tuner pressure at a fixed value for the desired resonant frequency. Alternately, the feedback loop can regulate the cavity tuner pressure to bring the RF detuning error to zero. The resonance controller is integrated into the LLRF control system for the cryomodule. The control system design and performance of the resonance control system are described in this paper.

43 PARTICLE ACCELERATORS↗

Nb₃Sn Coating of Twin Axis Cavity for SRF Applications

The twin axis cavity with two identical accelerating beams has been proposed for energy recovery linac (ERL) applications. Nb₃Sn is a superconducting material with a higher critical temperature and a higher critical field as compared to Nb, which promises a lower operating cost due to higher quality factors. Two niobium twin axis cavities were fabricated at JLab and were proposed to be coated with Nb₃Sn. Due to their more complex geometry, the typical coating process used for basic elliptical cavi-ties needs to be improved to coat these cavities. This development advances the current coating system at JLab for coating complex cavities. Two twin axis cavities were coated recently for the first time. This contribution dis-cusses initial results from coating of twin axis cavities, RF testing and witness sample analysis with an overview of the current challenges towards high performance Nb₃Sn coated twin axis cavities.

43 PARTICLE ACCELERATORS↗

Improved Spacecraft Materials for Radiation Protection

Methods by which radiation shielding is optimized need to be developed and materials of improved shielding characteristics identified and validated. The galactic cosmic rays (GCR) are very penetrating and the energy absorbed by the astronaut behind the shield is nearly independent of shield composition and even the shield thickness. However, the mix of particles in the transmitted beam changes rapidly with shield material composition and thickness. This results in part from the breakup of the high-energy heavy ions of the GCR which make contributions to biological effects out of proportion to their deposited energy. So the mixture of particles in the radiation field changes with shielding and the control of risk contributions from dominant particle types is critical to reducing the hazard to the astronaut. The risk of biological injury for a given particle type depends on the type of biological effect and is specific to cell or tissue type. Thus, one is faced with choosing materials which may protect a given tissue against a given effect but leave unchanged or even increase the risk of other effects in the same tissue or increase the risks to other adjacent tissues of a different type in the same individual. The optimization of shield composition will then be tied to a specific tissue and risk to that tissue. Such peculiarities arise from the complicated mixture of particles, the nature of their biological response, and the details of their interaction with material constituents. Aside from the understanding of the biological response to specific components, one also needs an accurate understanding of the radiation emerging from the shield material. This latter subject has been a principal element of this project. In the past ten years our understanding of space radiation interactions with materials has changed radically, with a large impact on shield design. For example, the NCRP estimated that only 2 g/sq cm. of aluminum would be required to meet the annual 500 mSv limit for the exposure of the blood forming organs (this limit is strictly for LEO but can be used as a guideline for the Mars mission analysis). The current estimates require aluminum shield thicknesses above 50 g/sq cm., which is impractical. In such a heavily shielded vehicle, the neutrons produced throughout the vehicle also contribute significantly to the exposure and this demands greater care in describing the angular dependence of secondary particle production processes. As such the continued testing of databases and transport procedures in laboratory and spaceflight experiments has continued. This has been the focus of much of the last year's activity and has resulted in improved neutron prediction capability. These new methods have also improved our understanding of the surface environment of Mars. The Mars 2003 NRA HEDS related surface science requirements were driven by the need to validate predictions on the upward flux of neutrons produced in the Martian regolith and bedrock made by the codes developed under this project. The codes used in the surface environment definition are also being used to look at in situ resources for the development of construction material for Martian surface facilities. For example, synthesis of polyimides and polyethylene as binders of regolith for developing basic structural elements has been studied and targets built for accelerator beam testing of radiation shielding properties. Preliminary mechanical tests have also been promising. Improved spacecraft materials have been identified (using the criteria reported by this project at the last conference) as potentially important for future shielding materials. These are liquid hydrogen, hydrogenated nanofibers, liquid methane, LiH, Polyethylene, Polysulfone, and Polyetherimide (in order of decreasing shield performance). Some of the materials are multifunctional and are required for other onboard systems. We are currently preparing software for trade studies with these materials relative to the Mars Reference Mission as required in the project's final year.

Wilson, John W.↗

Intense gamma-ray source based on focused electron beams from a laser wakefield accelerator

Laser wakefield accelerators generate ultrashort electron bunches with the capability to produce γ-rays. Here, we produce focused laser wakefield acceleration electron beams using three quadrupole magnets. Electron beams are then focused into a 3 mm lead converter to generate intense, focused bremsstrahlung γ beams. Experimental results demonstrate the generation and propagation of focused γ beams to a best focus spot size of 2.3 ± 0.1 × 2.7 ± 0.2 mm 2 using a copper stack calorimeter. Monte Carlo simulations conducted using GEANT4 are in good agreement with experimental results and enable detailed examination of γ-ray generation. Simulations indicate that the focused γ beams contained 2.6 × 10 9 photons in the range of 100 keV to 33 MeV with an average energy of 6.4 MeV. A γ-ray intensity of 7 × 10 10 W/cm 2 was estimated from simulations. In conclusion, the generation of focused bremsstrahlung γ-ray sources can have important applications in medical imaging applications and laboratory astrophysics experiments.

43 PARTICLE ACCELERATORS↗

The large-area hybrid-optics CLAS12 RICH: First years of data-taking

The CLAS12 deep-inelastic scattering experiment at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Lab conjugates luminosity and wide acceptance to study the 3D nucleon structure in the yet poorly explored valence region, and to perform precision measurements in hadron spectroscopy. A large area ring-imaging Cherenkov detector has been designed to achieve the required hadron identification in the momentum range from 3 GeV/c to 8 GeV/c, with the kaon rate about one order of magnitude lower than the rate of pions and protons. The adopted solution comprises aerogel radiator and composite mirrors in a novel hybrid optics design, where either direct or reflected light could be imaged in a high-packed and high-segmented photon detector. The first RICH module was assembled during the second half of 2017 and installed at the beginning of January 2018, in time for the start of the experiment. The second RICH module, planned with the goal to be ready for the beginning of the operation with polarized targets, has been timely built despite the complications caused by the pandemic crisis and successfully installed in June 2022. Finally, the detector performance is here discussed with emphasis on the operation and stability during the data-taking, calibration and alignment procedures, reconstruction and pattern recognition algorithms, and particle identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Highly efficient photoelectric effect in halide perovskites for regenerative electron sources

Electron sources are a critical component in a wide range of applications such as electron-beam accelerator facilities, photomultipliers, and image intensifiers for night vision. We report efficient, regenerative and low-cost electron sources based on solution-processed halide perovskites thin films when they are excited with light with energy equal to or above their bandgap. We measure a quantum efficiency up to 2.2% and a lifetime of more than 25 h. Importantly, even after degradation, the electron emission can be completely regenerated to its maximum efficiency by deposition of a monolayer of Cs. The electron emission from halide perovskites can be tuned over the visible and ultraviolet spectrum, and operates at vacuum levels with pressures at least two-orders higher than in state-of-the-art semiconductor electron sources.

36 MATERIALS SCIENCE↗

Physics of runaway electrons with shattered pellet injection at JET

Runaway electrons (REs) created during tokamak disruptions pose a threat to the reliable operation of future larger machines. Experiments using shattered pellet injection (SPI) have been carried out at the JET tokamak to investigate ways to prevent their generation or suppress them if avoidance is not sufficient. Avoidance is possible if the SPI contains a sufficiently low fraction of high-Z material, or if it is fired early in advance of a disruption prone to runaway generation. These results are consistent with previous similar findings obtained with Massive Gas Injection. Suppression of an already accelerated beam is not efficient using High-Z material, but deuterium leads to harmless terminations without heat loads. This effect is due to the combination of a large magnetohydrodynamic instability scattering REs on a large area and the absence of runaway regeneration during the subsequent current collapse thanks to the flushing of high-Z impurities from the runaway companion plasma. This effect also works in situations where the runaway beam moves upwards and undergoes scraping-off on the wall.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Commissioning of a replacement subatmospheric cold box for Jefferson Lab’s Central Helium Liquefier

Jefferson Lab’s Cryogenics Department has designed, fabricated, installed, and commissioned a new subatmospheric cold box to replace one of the two existing units within our Central Helium Liquefier (CHL). The replacement cold box, dubbed SC1R, pumps saturated helium vapor at 0.0385 atm from Jefferson Lab’s continuous electron beam accelerator facility (CEBAF) cryomodules to maintain an operating temperature of nominally 2.1 K. This is accomplished using a five-stage cryogenic centrifugal compressor (cold compressor) system and a brazed aluminum plate-fin heat exchanger operating between 2.1 K and 4.5 K. In this paper we will describe our experience commissioning the SC1R cold box. We will discuss pump-down of the system to 2.1 K and steady-state operation at the cold compressor design flow rates of 170, 200, and 250 g/s. Performance of the heat exchanger and cold compressors has been mapped across a range of flow rates and optimized for CEBAF operations. This commissioning data will be used to monitor future performance and adapt to changing load requirements.

Mastracci, B.↗

Detecting anomalous SRF cavity behavior with unsupervised learning

We present an unsupervised learning framework for detecting anomalous superconducting radio-frequency (SRF) cavity behavior at the Continuous Electron Beam Accelerator Facility (CEBAF), emphasizing its initial performance and effectiveness. Key to the system’s success was the development of data acquisition systems (DAQs) that capture fast-sampled, information-rich signals, essential for detecting transient effects. The approach involves creating daily cavity-specific models using principal component analysis to handle variations in rf signal behavior and mitigate performance degradation from data drift. This unsupervised method eliminates the need for expensive labeling by continuously updating models with recent data. Deployed and operational for 3 months before a scheduled shutdown, the system successfully identified several issues with DAQ signals, confirming its effectiveness. Despite access to only a fraction of CEBAF’s SRF cavity signals, the framework efficiently detected several instances requiring intervention, demonstrating a significant improvement over traditional, labor-intensive methods of manual plot inspection. Published by the American Physical Society 2025

43 PARTICLE ACCELERATORS↗

Diffusion model approach to simulating electron-proton scattering events

Generative artificial intelligence is a fast-growing area of research offering various avenues for exploration in high-energy nuclear physics. In this work, we explore the use of generative models for simulating electron-proton collisions relevant to experiments like the Continuous Electron Beam Accelerator Facility and the future Electron-Ion Collider (EIC). These experiments play a critical role in advancing our understanding of nucleons and nuclei in terms of quark and gluon degrees of freedom. The use of generative models for simulating collider events faces several challenges such as the sparsity of the data, the presence of global or eventwide constraints, and steeply falling particle distributions. In this work, we focus on the implementation of diffusion models for the simulation of electron-proton scattering events at EIC energies. Our results demonstrate that diffusion models can reproduce relevant observables such as momentum distributions and correlations of particles, momentum sum rules, and the leading electron kinematics, all of which are of particular interest in electron-proton collisions. Although the sampling process is relatively slow compared to other machine-learning architectures, we find diffusion models can generate high-quality samples. We foresee various applications of our work including inference for nuclear structure, interpretable generative machine learning, and searches of physics beyond the Standard Model. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study on Conduction Cooling of Superconducting Magnets for the ILC Main Linac

In the main linac of the International Linear Collider (ILC), superconducting magnets for beam focusing and steering will be located periodically in superconducting RF (SRF) cavity string for beam acceleration in common cryomodules. A concept of conduction cooling of the combined-functioned, splittable superconducting magnets has been proposed and investigated to adapt much different features and to meet different requirements for the superconducting magnet and SRF cavity in fabrication, assembly, and operation. It is required to integrate the superconducting magnet after the SRF cavity string assembly which completed under an ultra-clean environment. The magnet must be conductively cooled down through thermal links to a liquid helium supply pipe. According to this concept, a model magnet development was carried out in cooperation with Fermilab and KEK, and has been demonstrated in KEK superconducting RF test facility (STF). In addition, an important issue has been recently identified. High gradient SRF cavities naturally emit field emission electron flux from the inner surface, so-called dark current. It may pass through the subsequent SRF cavity string and penetrate into the superconducting magnets placed downstream. It may heat up the superconducting coils, and may cause a quench. Therefore, further study on reliable conduction cooling and to secure the superconducting magnet operation with a keeping sufficient safety margin is quite essential. In this paper, we report the installation, the improvement achieved in STF, and the R&D progress in the study on the conduction cooling of the superconducting magnet for the ILC main linac.

43 PARTICLE ACCELERATORS↗

Strong interaction physics at the luminosity frontier with 22 GeV electrons at Jefferson Lab

Here, the purpose of this document is to outline the developing scientific case for pursuing an energy upgrade to 22 GeV of the Continuous Electron Beam Accelerator Facility (CEBAF) at the Thomas Jefferson National Accelerator Facility (TJNAF, or JLab). This document was developed with input from a series of workshops held in the period between March 2022 and April 2023 that were organized by the JLab user community and staff with guidance from JLab management (see Sec. 10). The scientific case for the 22 GeV energy upgrade leverages existing or already planned Hall equipment and world-wide uniqueness of CEBAF high-luminosity operations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-$Q_0$ treatment of CEBAF 1.5 GHz SRF cavities

The Continuous Electron Beam Accelerator Facility (CEBAF) was the first large-scale accelerator to employ superconducting radiofrequency (SRF) cavities for continuous-wave operation. Ongoing research and development efforts continue to focus on increasing the intrinsic quality factor (Q 0 ) of these cavities in order to reduce cryogenic losses while maintaining operational gradients. Here, in this work, we report on the application of high-Q 0 surface treatments to single-cell and multicell C100 and C75 style 1.5 GHz niobium cavities used in the CEBAF accelerator. Nitrogen infusion and oxygen alloying via medium-temperature baking were applied under heat-treatment constraints relevant to existing cavity hardware. Both processes yielded substantial improvements in Q 0 at moderate accelerating gradients, achieving values of approximately 2 × 10 10 at 2.07 K and 20 MV/m. The effectiveness of nitrogen infusion at reduced annealing temperatures and the successful extension of oxygen alloying to multicell cavities are demonstrated. These results establish viable pathways for implementing high-Q 0 treatments in CEBAF-compatible cavities and support future integration into cryomodules for reduced operational cryogenic load.

Dhakal, Pashupati [Thomas Jefferson National Accel↗

Initial Implementation Of Machine Learning System for SRF Cavity Fault Classification at CEBAF

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory is high power CW electron accelerator. It uses a mixture of two types of SRF modules, older, lower energy C20/C50 modules and newer higher energy C100 modules, arrayed in two anti-parallel linear accelerators. Accurately classifying the type of cavity faults is essential to maintaining and improving accelerator performance. Each C100 cryomodule contains eight 7-cell cavities. When a cavity fault occurs within a cryomodule, all eight cavities generate 17 waveforms each containing 8192 points. This data is exported from EPICS and saved for review. Analysis of these waveforms is time intensive and requires subject matter expertise (SME). SMEs examine the data from each event and label it according to one of several known cavity fault types. Multiple machine learning models have been developed on this labeled dataset with sufficient performance to warrant the creation of a limited machine learning software system for use by accelerator operations staff. This paper discusses the transition from model development to implementation of a prototype system.

Carpenter, A.↗

INITIAL STUDIES OF CAVITY FAULT PREDICTION AT JEFFERSON LABORATORY

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory is a CW recirculating linac that utilizes over 400 superconducting radio-frequency (SRF) cavities to accelerate electrons up to 12 GeV through 5-passes. Recent work has shown that, given RF signals from a cavity during a fault as input, machine learning approaches can accurately classify the fault type. In this paper we report on initial results of predicting a fault onset using only data prior to the failure event. A data set was constructed using time-series data immediately before a fault (’unstable’) and 1.5 seconds prior to a fault (’stable’) gathered from over 5,000 saved fault events. The data was used to train a binary classifier. The results gave key insights into the behavior of several fault types and provided motivation to investigate whether data prior to a failure event could also predict the type of fault. We discuss our method using a sliding window approach and report on initial results. Recent modifications to the low-level RF control system will provide access to streaming signals and we outline a path forward for leveraging deep learning on streaming data

Vidyaratne, Lasitha↗

Superconducting Radio-frequency Cavity Fault Classification Using Machine Learning at Jefferson Laboratory

We report on the development of machine learning models for classifying C100 superconducting radiofrequency (SRF) cavity faults in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. Of the 418 SRF cavities in CEBAF, 96 are designed with a digital low-level RF system configured such that a cavity fault triggers recordings of RF signals for each of eight cavities in the cryomodule. Subject matter experts analyze the collected time-series data and identify which of the eight cavities faulted first and classify the type of fault. This information is used to find trends and strategically deploy mitigations to problematic cryomodules. However, manually labeling the data is laborious and time-consuming. By leveraging machine learning, near real-time - rather than postmortem - identification of the offending cavity and classification of the fault type has been implemented. We discuss the performance of the machine learning models during a recent physics run. We also discuss efforts for further insights into fault types through unsupervised learning techniques and present preliminary work on cavity and fault prediction using data collected prior to a failure event.

Tennant, C. D.↗

Modeling for the phased injector upgrade for 12 GeV CEBAF

As a follow on to the 12 GeV upgrade to the Continuous Electron Beam Accelerator Facility, the front end of the DC photo-gun-based injector has gone through a phased upgrade. The first phase focused on the beamline between the gun and the RF chopper system, and the second phase addresses the beamline after the RF chopper system including replacing the capture section and quarter cryomodule with a new booster module containing a 2-cell and 7-cell cavity string. Throughout the design process, we maintained and developed three models, one for the existing injector and one for each of the upgrade phases. With these models, we evaluated proposed hardware upgrades, evaluated and determined optimized beamline element positions, developed buncher voltage requirements, and settings for optimal injector running. In this paper, we will describe the models and results from these various studies and provide a brief summary of Phase 1 commissioning.

Kazimi, R.↗