Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “XRAY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

267 records · Page 15

In Situ High Energy X-ray Diffraction Characterization of Phase Transformations and Mechanical Behaviors in Rapidly Solidified Titanium and Stainless Steel Alloys [Thesis]

Advanced manufacturing techniques like additive manufacturing (AM) have poised themselves to revolutionize metal manufacturing. A wide range of AM techniques are capable of manufacturing metal components with unique, complex geometries and hastening the scientific-engineering-development cycle. Metal AM relies on a layer-by-layer rapid manufacturing process to build components from the substrate up. Rapid solidification is a large departure from traditional metal manufacturing due to its complex physics. Characterization of rapid solidification is difficult, stemming from the small volumes used in AM and the fast dynamics of the process. High energy X-ray diffraction (HEXRD) is a solution to the characterization problems of rapidly solidified alloys and AM. HEXRD can probe small volumes at fast rates and provides a wide range of thermomechanical and kinetic information. This thesis presents the application of HEXRD to rapidly solidified titanium and stainless steel alloys through a series of case studies. In the first two studies, HEXRD is applied to rapidly solidified titanium and stainless steel welds. The materials are characterized for their temperature history, phase changes, kinetics, and microstructural evolution. In the next case study, HEXRD is applied to characterize phase changes in elastocaloric NiTi shape memory alloys (SMAs) under thermomechanical load. HEXRD, in conjunction with other tools, is used to explain the superior performance of the additively manufactured SMAs. In the final two case studies, HEXRD is used to measure the mechanical response of AM parts with complex geometries; namely, the octet truss lattice. Diffraction reveals a wide range of materials information about the AM microstructure including unexpected phases, texture, and mechanical response to loading. The mechanical results from HEXRD and then compared with theoretical predictions about the performance of octet truss lattices. Summarily, HEXRD is a diverse tool that is poised to address the complex characterization problems of many aspects of the additive manufacturing process.

36 MATERIALS SCIENCE↗

Fracture Intersections under Stress: Laboratory Data and Code [Data set]

The connectivity of natural and induced fractures governs the injection and withdrawal of fluids from subsurface reservoirs. Connectivity depends on intersections that control how fluids mix and move through the entire system. Here, we present data sets from 3D X-ray microscopy measurements of simple fracture networks under stress. 3D printing was used to create prismatic blocks that formed fracture networks composed of 2 orthogonal fractures. The network orientation was either "x" or "+" relative to an applied vertical stress. 3D data sets were collected for normal loads of 25, 100 and 200 Newtons for samples with fracture surfaces with either correlated or uncorrelated asperity distributions. The file contains data from the 12 samples analyzed along with an example code used to extract the intersection geometry. Additional experimental details can be found in the manuscript "Geologic Stress Modulates Fluid Mixing at Fracture Intersections" (10.1038/s43247-026-03525-9)and supplemental information to appear in Communications Earth & Environment in 2026.

02 PETROLEUM↗

Design, Construction, and Testing of Lightweight X-ray Mirror Modules

Lightweight and high resolution optics are needed for future space-based X-ray telescopes to achieve advances in high-energy astrophysics. The Next Generation X-ray Optics (NGXO) team at NASA GSFC is nearing mission readiness for a 10 arc-second Half Power Diameter (HPD) slumped glass mirror technology while laying the groundwork for a future 1-2 arc-second technology based on polished silicon mirrors. Technology Development Modules (TDMs) have been designed, fabricated, integrated with mirrors segments, and extensively tested to demonstrate technology readiness. Tests include X-ray performance, thermal vacuum, acoustic load, and random vibration. The thermal vacuum and acoustic load environments have proven relatively benign, while the random vibration environment has proven challenging due to large input amplification at frequencies above 500 Hz. Epoxy selection, surface preparation, and larger bond area have increased bond strength while vibration isolation has decreased vibration amplification allowing for space launch requirements to be met in the near term. The next generation of TDMs, which demonstrates a lightweight structure supporting more mirror segments, is currently being fabricated. Analysis predicts superior performance characteristics due to the use of E-60 Beryllium-Oxide Metal Matrix Composite material, with only a modest cost increase. These TDMs will be larger, lighter, stiffer, and stronger than the current generation. Preliminary steps are being taken to enable mounting and testing of 1-2 arc-second mirror segments expected to be available in the future. A Vertical X-ray Test Facility (VXTF) will minimize module gravity distortion and allow for less constrained mirror mounts, such as fully kinematic mounts. Permanent kinematic mounting into a modified TDM has been demonstrated to achieve 2 arc-second level distortion free alignment.

contruction↗

Application of X-Ray Pulsar Navigation: A Characterization of the Earth Orbit Trade Space

The potential for pulsars as a navigation source has been studied since their discovery in 1967. X-ray pulsar navigation (XNAV) is a celestial navigation system that uses the consistent timing nature of x-ray photons from milli-second pulsars (MSP) to perform space navigation. By comparing the detected arrival of x-ray photons to a reference database of expected pulsar lightcurve timing models, one can infer a range and range rate measurement based on light time delay. Much of the challenge of XNAV comes from the faint signal, availability, and distant nature of pulsars. This is a study of potential pulsar XNAV measurements to measure extended Kalman filter (EKF) tracking performance with a wide trade space of bounded Earth orbits, using a simulation of existing x-ray detector space hardware. An example of an x-ray detector for XNAV is the NASA Station Explorer for X-ray Timing and Navigation (SEXTANT) mission, a technology demonstration of XNAV set to perform on the International Space Station (ISS) in late 2016early 2017. XNAV hardware implementation is driven by trajectory and environmental influences which add noise to the x-ray pulse signal. In a closed Earth orbit, the radiation environment can exponentially increase the signal noise from x-ray pulsar sources, decreasing the quality and frequency of measurements. The SEXTANT mission in particular improves on the signal to noise ratio by focusing an array of 56 x-ray silicon drift detectors at one pulsar target at a time. This reduces timing glitches and other timing noise contributions from ambient x-ray sources to within a 100 nanosecond resolution. This study also considers the SEXTANT scheduling challenges inherent in a single target observation. Finally, as the navigation sources are now relatively inertial targets, XNAV measurements are also subject to periods of occultation from various celestial bodies. This study focuses on the characterization of these drivers in closed Earth orbits and is not a tuning analysis of the EKF. The study shows that the closed Earth orbit for XNAV performance is reliant on the orbit semi-major axis and eccentricity as well as orbit inclination. These parameters are the primary drivers of pulsar measurement availability and significantly influence the natural spacecraft orbit dynamics. Sensitivity to initial orbit determination error growth due to the scarcity of XNAV measurements within an orbital period require appropriate timing of initial XNAV measurements. The orbit angles of argument of perigee and right ascension of the ascending node, alongside the other orbit parameters, complete the initial cadence of XNAV measurements. The performance of initial XNAV measurements then propagates throughout the experimental period. The study provides a basis to missions who wish to consider XNAV as a potential navigation source in a closed Earth orbit design. It provides a family of orbit trajectories as well as other modeling considerations needed to effectively evaluate if XNAV is an effective navigation source for a potential mission. As an EKF is sensitive to a linearized estimated state, this study has a direct benefit of providing effective XNAV measurements to maintain spacecraft tracking, independent of other navigation sources. In the particular use case of the SEXTANT mission, it also provides a novel scheduling algorithm which addresses the need to prioritize and manage pulsar observations for effective navigation.

PULSAR↗

IGR J170626143 is an Accreting Millisecond X-Ray Pulsar

We present the discovery of 163.65 Hz X-ray pulsations from IGR J17062−6143 in the only observation obtained from the source with the Rossi X-ray Timing Explorer. This detection makes IGR J17062−6143 the lowest frequency accreting millisecond X-ray pulsar presently known. The pulsations are detected in the 2-12 keV band with an overall significance of 4.3sigma and an observed pulsed amplitude of 5.54% +/-0.67% (in this band). Both dynamic power spectral and coherent phase timing analysis indicate that the pulsation frequency is decreasing during the approx. =1.2 ks observation in a manner consistent with orbital motion of the neutron star. Because the observation interval is short, we cannot precisely measure the orbital period; however, periods shorter than 17 minutes are excluded at 90% confidence. For the range of acceptable circular orbits the inferred binary mass function substantially overlaps the observed range for the AMXP population as a whole.

stars: neutron↗

Wide Field-of-View Soft X-Ray Imaging for Solar Wind-Magnetosphere Interactions

Soft X-ray imagers can be used to study the mesoscale and macroscale density structures that occur whenever and wherever the solar wind encounters neutral atoms at comets, the Moon, and both magnetized and unmagnetized planets. Charge exchange between high charge state solar wind ions and exospheric neutrals results in the isotropic emission of soft X-ray photons with energies from 0.1 to 2.0 keV. At Earth, this process occurs primarily within the magnetosheath and cusps. Through providing a global view, wide field-of-view imaging can determine the significance of the various proposed solar wind-magnetosphere interaction mechanisms by evaluating their global extent and occurrence patterns. A summary of wide field-of-view (several to tens of degrees) soft X-ray imaging is provided including slumped micropore microchannel reflectors, simulated images, and recent flight results.

xray↗

New 'Molecular Movie' Reveals Ultrafast Chemistry in Motion

Scientists for the first time tracked ultrafast structural changes, captured in quadrillionths-of-a-second steps, as ring-shaped gas molecules burst open and unraveled. Ring-shaped molecules are abundant in biochemistry and also form the basis for many drug compounds. The study points the way to a wide range of real-time X-ray studies of gas-based chemical reactions that are vital to biological processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scientists Get First Glimpse of a Chemical Bond Being Born

Scientists have used an X-ray laser at the Department of Energy’s SLAC National Accelerator Laboratory to get the first glimpse of the transition state where two atoms begin to form a weak bond on the way to becoming a molecule.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗