Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “XENON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Low-energy nuclear recoil calibration of the LUX-ZEPLIN experiment with a photoneutron source

The LZ experiment is a liquid xenon time-projection chamber (TPC) searching for evidence of particle dark matter interactions. In the simplest assumption of elastic scattering, many dark matter models predict an energy spectrum which rises quasi-exponentially with decreasing energy transfer to a target atom. LZ expects to detect coherent neutrino-nucleus scattering of $^{8}$B solar neutrinos, the signal from which is very similar to a dark matter particle with mass of about 5.5 GeV/$c^{2}$, which result in typical nuclear recoil energies of $<$5 keV$_{\text{nr}}$. Therefore, it is of crucial importance to calibrate the response of recoiling xenon nuclei to keV-energy recoils. This analysis details the first in situ photoneutron calibration of the LZ detector and probes its response in this energy regime.

Aalbers, J. [SLAC; Stanford U., Phys. Dept.; KIPAC↗

Demonstration of Sub-Percent Energy Resolution in the NEXT-100 Detector

NEXT-100 is a high-pressure xenon time projection chamber with electroluminescent amplification, designed to operate with up to approximately 70.5 kg at 13.5 bar. It is the most recent detector developed by the NEXT collaboration to search for the neutrinoless double-beta decay ($ββ0ν$) of Xe-136. The NEXT gas TPC technology offers the best energy resolution near the Q-value of the decay ($Q_{ββ}$ = 2458 keV) among xenon detectors, which is set by design to be <1% FWHM. We report here the high-energy calibration of the detector using a Th-228 source, demonstrating linear response and an energy resolution of $(0.90 \pm 0.02)$% FWHM at the Tl-208 photopeak (2615 keV). This performance extrapolates to a resolution at the double-beta decay end-point of $R(Q_{ββ})$ = $(0.93 \pm 0.02)$% FWHM, confirming the detector's capability for precision energy measurement in the search for $ββ0ν$.

Pérez Maneiro, M. [Santiago de Compostela U., IGFA↗

Demonstration of background rejection using deep convolutional neural networks in the NEXT experiment

Convolutional neural networks (CNNs) are widely used state-of-the-art computer vision tools that are becoming increasingly popular in high-energy physics. In this paper, we attempt to understand the potential of CNNs for event classification in the NEXT experiment, which will search for neutrinoless double-beta decay in $^{136}$Xe. To do so, we demonstrate the usage of CNNs for the identification of electron-positron pair production events, which exhibit a topology similar to that of a neutrinoless double-beta decay event. These events were produced in the NEXT-White high-pressure xenon TPC using 2.6 MeV gamma rays from a $^{228}$Th calibration source. We train a network on Monte Carlo-simulated events and show that, by applying on-the-fly data augmentation, the network can be made robust against differences between simulation and data. The use of CNNs offers significant improvement in signal efficiency and background rejection when compared to previous non-CNN-based analyses.[graphic not available: see fulltext]

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First STAX detector installation at the National Institute for Radioelements (IRE)

The Source Term Analysis of Xenon (STAX) project has been installing stack detectors at medical isotope production facilities to measure radioxenon emissions to investigate the effect of radioxenon releases on nuclear explosion monitoring. This paper outlines the installation of the first STAX detection system at the National Institute for Radioelements (IRE) in Fleurus, Belgium which has been operating for over three years and transferring collected data to the STAX repository. Information about the equipment installed, the data flow established, and calculations for determination of radioxenon releases from the facility are presented. Further. data quality was investigated to confirm values reported by STAX automated data processing and in a comparison of collected STAX data with data collected by IRE for regulatory reporting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evidence of Xe-incorporation in the bubble superlattice in irradiated U-Mo fuel

For years, researchers have reported competing ideas on the formation of fission gas bubble super lattices in metallic fuels, which was postulated to be comprised of elemental xenon (Xe) atoms. However, the chemical and physical arrangement of these elements within this gas bubble superlattice has not been verified. In this contribution, Xe was chemically profiled using atomic resolution scanning transmission electron microscopy (STEM) and atom probe tomography (APT) techniques in irradiated uranium-molybdenum (U-Mo) fuels. These complementary techniques provide conclusive evidence of Xe presence in bubble superlattice up to fission densities of 4.5×10 21 fissions/cm 3 and provide quantitative assessment of Xe content within the bubble superlattice. Based on the results of simultaneous imaging and spectroscopy using STEM, the chemical composition of the Xe bubble superlattice present in fission densities less than 4.5x10 21 fissions/cm 3 in U-Mo fuel was measured and found to be up to 8±1.3 atomic %. APT data complements STEM findings on Xe distribution in irradiated U-Mo fuel sample. APT showed a chemical composition of 0.7±0.1 atomic%. Finally, this study concludes by providing conclusive evidence that Xe is not only present within an atomically arranged bubble superlattice but provides fundamental insight the physical state of Xe in low enriched U-Mo monolithic fuel.

36 MATERIALS SCIENCE↗

Impact of grain boundary and surface diffusion on predicted fission gas bubble behavior and release in UO 2 fuel

In this work, we quantify the impact of grain boundary (GB) and surface diffusion on fission gas bubble evolution and fission gas release in UO 2 nuclear fuel using simulations with a hybrid phase field/cluster dynamics model. Here, we begin with a comprehensive literature review of uranium vacancy and xenon atom diffusivity in UO 2 through the bulk, along GBs, and along surfaces. In our model we represent fast GB and surface diffusion using a heterogeneous diffusivity that is a function of the order parameters that represent bubbles and grains. We find that the GB diffusivity directly impacts the rate of gas release via GB transport, and that the GB diffusivity is likely below 104 times the lower value from Olander and van Uffelen. We also find that the surface diffusivity impacts bubble coalescence and mobility, and that the bubble surface diffusivity is likely below 10 -4 times the value from Zhou and Olander.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Novel X-ray scanning technique for in-situ alignment of photo-detectors in the MEGII calorimeter

Here, we describe and show results of a novel technique to measure with high precision the positions of photodetectors installed in the upgraded liquid xenon calorimeter of the MEG II experiment. The measurement was done by detecting the signal in individual photo-detectors as the front surface of the calorimeter was scanned in axial (Z) and azimuthal (Φ) directions with a precisely controlled, thin, collimated beam of X-rays obtained from a 57 CoX-ray source. The measurements were made when the calorimeter was cold and operational, under which conditions they could not otherwise be made. This technique is used to check for changes in the photodetector positions due to the effects of cooling and thermal cycling of the support structure and to provide a reference between the positions of the operational photodetectors and alignment markers on the cryostat exterior. The use of an essentially monochromatic X-ray source allowed ancillary measurements of photodetector properties, including pulse shape, relative gain, and variation in response over the photodetector surface. Measurement uncertainties below 0.6mm in Z and 0.7 mrad in Φ have been achieved, well within the requirements for the MEG II performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using Xe Plasma FIB for High-Quality TEM Sample Preparation

Here, a direct comparison between electron transparent transmission electron microscope (TEM) samples prepared with gallium (Ga) and xenon (Xe) focused ion beams (FIBs) is performed to determine if equivalent quality samples can be prepared with both ion species. We prepared samples using Ga FIB and Xe plasma focused ion beam (PFIB) while altering a variety of different deposition and milling parameters. The samples’ final thicknesses were evaluated using STEM-EELS $\textit{t/λ}$ data. Using the Ga FIB sample as a standard, we compared the Xe PFIB samples to the standard and to each other. We show that although the Xe PFIB sample preparation technique is quite different from the Ga FIB technique, it is possible to produce high-quality, large area TEM samples with Xe PFIB. We also describe best practices for a Xe PFIB TEM sample preparation workflow to enable consistent success for any thoughtful FIB operator. For Xe PFIB, we show that a decision must be made between the ultimate sample thickness and the size of the electron transparent region.

47 OTHER INSTRUMENTATION↗

Evaluation of Engineered Form MOFs CaSDB and HKUST-1

Idaho National Laboratory (INL) and Pacific Northwest National Laboratory (PNNL) have studied different sorbents for the purpose of separating krypton (Kr) and xenon (Xe). PNNL has researched various metal-organic frameworks (MOFs) that have characteristics theoretically suitable for the separation. Based on computational analysis, PNNL chose Calcium–4,4’–sulfonyl dibenzoate (CaSDB) and Hong Kong University of Science and Technology MOF1 (HKUST–1). The raw MOFs are supplied in a powder form and must be incorporated into a robust engineered form to be viable for gas separation. In 2016, PNNL produced an engineered form of CaSDB by compressing and grinding the raw MOF material. This form was sent to INL for adsorption testing. Gentle mechanical agitation of the compressed form produced a large amount of powder, resulting in the conclusion that the form was not viable for the application. In 2019, INL successfully produced two engineered forms, CaSDB–EF1 and HKUST–EF2, by incorporating the active MOF powders into a polyacrylonitrile (PAN) binder. PNNL also produced two engineered forms, CaSDB–10pmma and HKUST–10pmma, by using polymethyl methacrylate (PMMA) as a binder. Surface area analysis indicated that the forms could be viable for separations in which the CaSDB–EF1 retained 84% of the raw CaSDB surface area and CaSDB–10pmma retained 48%. HKUST–EF2 retained all the raw HKUST–1 surface area, whereas HKUST–10pmma retained only 28%. Mechanical stability testing demonstrated that the PMMA forms formed a fine powder whereas, the PAN forms did not. In general, adsorption testing showed that CaSDB–10pmma had a lower Xe breakthrough capacity than CaSDB–EF1, but a higher saturation capacity at both room temperature and at 253 K. The CaSDB MOF was intended to be used as a room temperature sorbent to capture Xe. However, both CaSDB engineered forms displayed relatively short initial break through times. Reduced temperature increased the Xe capacity of both engineered forms. HKUST–1 was expected to be effective only at sub-zero temperatures. At 195 K, HKUST–10pmma had an initial Xe breakthrough capacity of 119 mmol/ kg, compared to HKUST–EF2 at 339 mmol/ kg. The saturation capacities were 275 and 383 mmol/ kg, respectively. HKUST–10ppm also had a lower Kr capacity of 1.7 mmol/kg, whereas the HKUST–EF had a Kr capacity of 3 mmol/ kg. Test results indicate that the PAN engineered forms are a more suitable choice for the complete separation of Xe and Kr, due to the increase in initial breakthrough capacity. CaSDB allows rapid breakthrough of Kr and Xe regardless of the type of engineered form. At 253 K, it is more viable, but is still not the most effective sorbent. HKUST–EF2 demonstrated viability for Xe capture at 195 K, which may merit further study, however it may be cost prohibitive.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Event Detection System in the NEXT-White Detector

This article describes the event detection system of the NEXT-White detector, a 5 kg high pressure xenon TPC with electroluminescent amplification, located in the Laboratorio Subterráneo de Canfranc (LSC), Spain. The detector is based on a plane of photomultipliers (PMTs) for energy measurements and a silicon photomultiplier (SiPM) tracking plane for offline topological event filtering. The event detection system, based on the SRS-ATCA data acquisition system developed in the framework of the CERN RD51 collaboration, has been designed to detect multiple events based on online PMT signal energy measurements and a coincidence-detection algorithm. Implemented on FPGA, the system has been successfully running and evolving during NEXT-White operation. The event detection system brings some relevant and new functionalities in the field. A distributed double event processor has been implemented to detect simultaneously two different types of events thus allowing simultaneous calibration and physics runs. This special feature provides constant monitoring of the detector conditions, being especially relevant to the lifetime and geometrical map computations which are needed to correct high-energy physics events. Other features, like primary scintillation event rejection, or a double buffer associated with the type of event being searched, help reduce the unnecessary data throughput thus minimizing dead time and improving trigger efficiency.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ASC Poster - Concentration of Xe from Simulated Dissolver Off-gas Streams Utilizing a Solid Sorbent, AgZ-PAN

Idaho National Laboratory (INL) has developed and tested engineered sorbents to separate and capture volatile fission products such iodine (I), xenon (Xe), and krypton (Kr) from off-gas streams. As noble gases, Xe and Kr can be difficult to capture and separate. Historically, cryogenic distillation has been used to execute the separation, but this method can pose significant hazards. INL has successfully developed two sorbents for Xe and Kr capture, silver mordenite polyacrylonitrile (AgZ-PAN) and hydrogen mordenite polyacrylonitrile (HZ-PAN). Adsorption studies to date successfully separated and captured Xe from carrier gas streams, but those studies focused primarily on initial separation and capture. In addition, the ability to concentrate Xe through multiple adsorption and desorption cycles has not been studied and therefore is the focus on this presentation. Concentrating Xe during desorption is ideal to produce Xe that can be used for commercial and research applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

133Xe Noble Gas Mass Spectrometry Measurement for High Purity Germanium Detector Performance Verification

Idaho National Laboratory produces quality control standards for laboratories that operate xenon radionuclide monitoring systems. Activities reported with each quality control standard are quantified using high purity germanium detectors. A collection of measurement capabilities are being set up at Idaho National Laboratory to establish an in-house high purity germanium detector performance verification system, with noble gas mass spectrometry being one of these measurement capabilities. The first noble gas mass spectrometry and high purity germanium measurement comparison is presented here. A Xe-133 gas sample was prepared and the activity was quantified with high purity germanium detectors. The Xe-133 sample was diluted with a known quantity of isotopically enriched Xe-126 gas; the resulting Xe-133 : Xe-126 atom ratio was calculated to be 1.15x10-4 +/- 2% at reference time t. An aliquot of this gas sample containing approximately 10 million Xe-133 atoms was introduced into a ThermoFisher Scientific Helix MC Plus noble gas mass spectrometer for analysis. The measured Xe-133 : Xe-126 atom ratio was determined to be 1.10x10-4 +/- 2% (1-sigma uncertainty) at reference time t, about 4.3% lower than the atom ratio determined with the measured high purity germanium activity.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Nanoscale Editing of Multi and Single Layer Tungsten Disulfide via Gas‐Assisted Focused Electron Beam Induced Etching for Device Prototyping

Focused electron beam induced etching (FEBIE) with XeF 2 (xenon difluoride) precursor is conducted on multi-layer exfoliated WS 2 (tungsten disulfide) and monolayer WS 2 grown by chemical vapor deposition (CVD). The films are characterized by atomic force microscopy (AFM) and Raman and photoluminescence (PL) spectroscopy post-etching. The etch rates/efficiencies are reported as a function of electron beam energy, current, dwell time, and XeF 2 pressure. Bulk film Raman spectra are unchanged post-FEBIE, indicating minimal subsurface damage. Monolayer WS 2 shows a decrease in Raman and PL intensity post-FEBIE, with a dose-to-clear of ≈2 nC µm −2 . The study reveals regimes affected by the various mass transport contributions such as refresh time and the ratio of electrons/XeF 2 . Spontaneous etching was discovered during FEBIE of large patterned areas due to the long frame/refresh times. Density functional theory and ab initio molecular dynamics simulations compares desorption of SF x and WF x molecules from pristine WS 2 basal planes and pore edges, revealing the spontaneous etching is consistent with etching of partially etched monolayers during each frame. Single-line etching width of 21 nm, and patterning flakes into 100 nm wide channels are demonstrated. In conclusion, this work demonstrates the possibility of editing WS 2 flakes into electronic devices of arbitrary dimensions for semiconductor applications.

2D materials↗

Pulsed Light Synthesis of High Entropy Nanocatalysts with Enhanced Catalytic Activity and Prolonged Stability for Oxygen Evolution Reaction

The ability to synthesize compositionally complex nanostructures rapidly is a key to high-throughput functional materials discovery. In addition to being time-consuming, a majority of conventional materials synthesis processes closely follow thermodynamics equilibria, which limit the discovery of new classes of metastable phases such as high entropy oxides (HEO). Herein, a photonic flash synthesis of HEO nanoparticles at timescales of milliseconds is demonstrated. By leveraging the abrupt heating and cooling cycles induced by a high-power-density xenon pulsed light, mixed transition metal salt precursors undergo rapid chemical transformations. Hence, nanoparticles form within milliseconds with a strong affinity to bind to the carbon substrate. Oxygen evolution reaction (OER) activity measurements of the synthesized nanoparticles demonstrate two orders of magnitude prolonged stability at high current densities, without noticeable decay in performance, compared to commercial IrO 2 catalyst. This superior catalytic activity originates from the synergistic effect of different alloying elements mixed at a high entropic state. It is found that Cr addition influences surface activity the most by promoting higher oxidation states, favoring optimal interaction with OER intermediates. The proposed high-throughput method opens new pathways toward developing next-generation functional materials for various electronics, sensing, and environmental applications, in addition to renewable energy conversion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Ultra-microporous Metal-Organic Framework with Exceptional Xe Capacity

Molecular confinement plays a significant effect on trapped gas and solvent molecules. A fundamental understanding of gas adsorption within the porous confinement provides information necessary to design a material with improved selectivity. In this regard, metal organic frameworks (MOFs) adsorbents are ideal candidate materials to study confinement effects for weakly interacting gas molecules such as noble gases. Among the noble gases, Xenon (Xe) has practical applications in the medical, automotive and aerospace industries. In this communication, we report an ultra-microporous nickel-isonicotinate MOF with exceptional Xe uptake and selectivity compared to all benchmark MOF and porous organic cage materials. The selectivity arises because of the near perfect fit of the atomic Xe inside the porous confinement. Notably, at low partial pressure, the Ni-MOF interacts very strongly with Xe compared to the closely related Krypton gas (Kr) and more polarizable CO2. Further 129Xe NMR suggests a broad isotropic chemical shift due to the reduced motion as a result of confinement.

Confinement effects, atomically precise materials,↗

Degradation Diagnostics from the Subsurface of Lithium-Ion Battery Electrodes

Despite the long-established rocking-chair theory of lithium-ion batteries (LIBs), developing novel characterization methodology with higher spatiotemporal resolution facilitates a better understanding of the solid electrolyte interphase studies to shape the reaction mechanisms. In this work, we develop a Xenon ion plasma focused ion beam (Xe + PFIB)-based characterization technique to probe the cross-sectional interface of both ternary cathode and graphite anode electrodes, with the focus on revealing the chemical composition and distribution underneath the electrode surface by in-depth analysis of secondary ions. Particularly, the lithium fluoride is detected in the pristine cathode prior to contact with the electrolyte, reflecting that the electrode degradation is in the form of the loss of lithium inventory during electrode preparation. This degradation is related to the hydrolysis of the cathode material and the decomposition of the PVDF binder. Here, through the quantitative analysis of the transition-metal degradation products, manganese is found to be the dominant element in the newly formed inactive fluoride deposition on the cathode, while no transition metal signal can be found inside the anode electrode. These insights at high resolution implemented via a PFIB-based characterization technique not only enrich the understanding of the degradation mechanism in the LIBs but also identify and enable a high-sensitivity methodology to obtain the chemical survey at the subsurface, which will help remove the capacity-fade observed in most LIBs.

25 ENERGY STORAGE↗

Optical Durability of Contemporary PV Encapsulants Through Artificial UV Weathering

Modern c-Si photovoltaic (PV) cells provide high performance but can be vulnerable to ultraviolet light induced degradation (UV-ID). Encapsulants, if chosen correctly, can mitigate UV-ID of the PV cell. Here, we explore performance and durability of 14 commercial encapsulant materials before, during, and after irradiation with UV-containing light. Materials include contemporary, polymer-based encapsulants with a base polymer of poly (ethylene co-vinyl acetate) (EVA), polyethylene-..alpha..-olefin (POE), or their composite (EPE). Polymers contain additives that induce UV-blocking, UV-transmitting, or UV-downshifting properties. We use test coupons to study degradation in a chamber held at 65 degrees C under a xenon light source for up to 4000 h of exposure, corresponding to a cumulative dose of 11.5 MJ/m2 at 340 nm. We examine optical properties including spectral transmittance, yellowness index and spectral fluorescence, considering changes to both the encapsulant and glass as a function of weathering time. Degradation modes identified include discoloration, changes to UV cutoff wavelength, changes to solar-weighted transmittance, and most notably a change to the UV-managing properties of some additives. We propose the use of solar-weighted transmittance in the 300- to 400-nm range to better track performance changes in the UV region associated with the UV-related additive. This is especially relevant for the emerging class of UV-downshifting additives, as metrics like UV-cutoff can understate the degree of degradation or change in these materials. While most encapsulants show very little change after weathering, some show significant changes that directly impact how much UV light would reach an underlying cell.

14 SOLAR ENERGY↗

Sensitivity of the NEXT experiment to Xe-124 double electron capture

Double electron capture by proton-rich nuclei is a second-order nuclear process analogous to double beta decay. Despite their similarities, the decay signature is quite different, potentially providing a new channel to measure the hypothesized neutrinoless mode of these decays. The Standard-Model-allowed two-neutrino double electron capture (2$\nu$EC EC) has been predicted for a number of isotopes, but only observed in 78 Kr, 130 Ba and, recently, 124 Xe. The sensitivity to this decay establishes a benchmark for the ultimate experimental goal, namely the potential to discover also the lepton-number-violating neutrinoless version of this process, 0$\nu$EC EC. Here we report on the current sensitivity of the NEXT-White detector to 124 Xe 2$\nu$EC EC and on the extrapolation to NEXT-100. Using simulated data for the 2$\nu$EC EC signal and real data from NEXT-White operated with 124 Xe-depleted gas as background, we define an optimal event selection that maximizes the NEXT-White sensitivity. We estimate that, for NEXT-100 operated with xenon gas isotopically enriched with 1 kg of 124 Xe and for a 5-year run, a sensitivity to the 2$\nu$EC EC half-life of 6 × 10 22 y (at 90% confidence level) or better can be reached.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗