Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Burning plasma achieved in inertial fusion

Obtaining a burning plasma is a critical step towards self-sustaining fusion energy. A burning plasma is one in which the fusion reactions themselves are the primary source of heating in the plasma, which is necessary to sustain and propagate the burn, enabling high energy gain. After decades of fusion research, here we achieve a burning-plasma state in the laboratory. These experiments were conducted at the US National Ignition Facility, a laser facility delivering up to 1.9 megajoules of energy in pulses with peak powers up to 500 terawatts. We use the lasers to generate X-rays in a radiation cavity to indirectly drive a fuel-containing capsule via the X-ray ablation pressure, which results in the implosion process compressing and heating the fuel via mechanical work. The burning-plasma state was created using a strategy to increase the spatial scale of the capsule through two different implosion concepts. These experiments show fusion self-heating in excess of the mechanical work injected into the implosions, satisfying several burning-plasma metrics. Additionally, we describe a subset of experiments that appear to have crossed the static self-heating boundary, where fusion heating surpasses the energy losses from radiation and conduction. These results provide an opportunity to study α-particle-dominated plasmas and burning-plasma physics in the laboratory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cadmium Magnesium Telluride for Next Generation X-Ray Free Electron Laser, Synchrotron and Many Other Applications

We developed a picosecond photodetector based on our Bridgman grown and specially engineered Cadmium Magnesium Telluride (Cd 1-x Mg x Te) single crystal that is sensitive to both optical and x-ray pulses for coarse timing in Free Electron Laser applications. Cd 1-x Mg x Te is a wide bandgap semiconductor material with potential applications, not only in optoelectronics, but also in particle physics as an intense pulse radiation detector for bremsstrahlung, X-ray/gamma ray radiation, thermal neutrons, and medical imaging. However, for femtosecond optical and x-ray cross correlation, the material has to have very short lifetime, a condition that is opposite to that required for nuclear spectroscopy applications. At the same time, the material also needs to have very low bulk leakage current, in the 0.10 pA range. Hence the ability to tailor or engineer the material is very crucial. In this paper, picosecond response and the crystal growth of this specially engineered cadmium magnesium telluride material will be presented. Other material characterization and transient measurements will also be discussed along with room temperature semiconductor detector performance for other nuclear radiation detection applications.

36 MATERIALS SCIENCE↗

An improved methodology for modeling short pulse buried layer x-ray emission spectra

Radiation-hydrodynamic and spectroscopic modeling are important aspects of high energy density experimental design. In this paper, we improve the performance and capabilities over those obtainable with a previous methodology used for simulating x-ray emission spectra from buried layer targets heated by short pulse lasers. The improvement incorporates post-processing HYDRA radiation-hydrodynamic output with a non-local thermodynamic equilibrium atomic-kinetics radiation transport code, Cretin. Each code uses an independent radiation field which allows decoupling HYDRA's radiation group structure from Cretin's spectral output to improve the speed and flexibility of the design methodology. The execution time decreases from 2–3 days to a few hours while the flexibility of the improved methodology allows for performing sensitivity studies including a comparison of steady-state and time-dependent atomic kinetics and differences in the radiation group structure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using personal monitoring data to derive organ doses for medical radiation workers in the Million Person Study—considerations regarding NCRP Commentary no. 30

The study of low dose and low-dose rate exposure is of central importance in understanding the possible range of health effects from prolonged exposures to radiation. The One Million Person Study of Radiation Workers and Veterans (MPS) of low-dose health effects was designed to evaluate radiation risks among healthy American workers and veterans. The MPS is evaluating low-dose and dose-rate effects, intakes of radioactive elements, cancer and non-cancer outcomes, as well as differences in risks between women and men. Medical radiation workers make up a large group of individuals occupationally exposed to low doses of radiation from external x-ray/gamma exposures. For the MPS, about 100 000 United States medical radiation workers have been selected for study. The approach to the complex dosimetry circumstances for such workers over three to four decades of occupation were initially and broadly described in National Council on Radiation Protection and Measurements (NCRP) Report No. 178. NCRP Commentary No. 30 provides more detail and describes an optimum approach for using personal monitoring data to estimate lung and other organ doses applicable to the cohort and provides specific precautions/considerations applicable to the dosimetry of medical radiation worker organ doses for use in epidemiologic studies. The use of protective aprons creates dosimetric complexity. It is recommended that dose values from dosimeters worn over a protective apron be reduced by a factor of 20 for estimating mean organ doses to tissues located in the torso and that 15% of the marrow should be assumed to remain unshielded for exposure scenarios when aprons are worn. Conversion coefficients relating personal dose equivalent, H p (10) in mSv, to mean absorbed doses to organs and tissues, D T in mGy, for females and males for six exposure scenarios have been determined and presented for use in the MPS. This Memorandum summarises several key points in NCRP Commentary No. 30.

Environmental Sciences & Ecology↗

A laser powder bed fusion system for operando synchrotron x-ray imaging and correlative diagnostic experiments at the Stanford Synchrotron Radiation Lightsource

Laser powder bed fusion (LPBF) is a highly dynamic multi-physics process used for the additive manufacturing (AM) of metal components. Improving process understanding and validating predictive computational models require high-fidelity diagnostics capable of capturing data in challenging environments. Synchrotron x-ray techniques play a vital role in the validation process as they are the only in situ diagnostic capable of imaging sub-surface melt pool dynamics and microstructure evolution during LPBF-AM. In this article, a laboratory scale system designed to mimic LPBF process conditions while operating at a synchrotron facility is described. The system is implemented with process accurate atmospheric conditions, including an air knife for active vapor plume removal. Significantly, the chamber also incorporates a diagnostic sensor suite that monitors emitted optical, acoustic, and electronic signals during laser processing with coincident x-ray imaging. The addition of the sensor suite enables validation of these industrially compatible single point sensors by detecting pore formation and spatter events and directly correlating the events with changes in the detected signal. Experiments in the Ti–6Al–4V alloy performed at the Stanford Synchrotron Radiation Lightsource using the system are detailed with sufficient sampling rates to probe melt pool dynamics. X-ray imaging captures melt pool dynamics at frame rates of 20 kHz with a 2 µm pixel resolution, and the coincident diagnostic sensor data are recorded at 470 kHz. Furthermore, this work shows that the current system enables the in situ detection of defects during the LPBF process and permits direct correlation of diagnostic signatures at the exact time of defect formation.

36 MATERIALS SCIENCE↗

Experimental setup for high-resolution characterization of crystal optics for coherent X-ray beam applications

Stanford Synchrotron Radiation Lightsource serves a wide scientific community with its variety of X-ray capabilities. Recently, a wiggler X-ray source located at beamline 10-2 has been employed to perform high-resolution rocking curve imaging (RCI) of diamond and silicon crystals. X-ray RCI is invaluable for the development of upcoming cavity-based X-ray sources at SLAC, including the cavity-based X-ray free-electron laser and X-ray laser oscillator. In this paper, the RCI apparatus is described and experimental results are provided to validate its design. Future improvements of the setup are also discussed.

36 MATERIALS SCIENCE↗

Integrated atomic force microscopy and x-ray irradiation for in situ characterization of radiation-induced processes

Understanding radiation-induced chemical and physical transformations at material interfaces is important across diverse fields, but experimental approaches are often limited to either ex situ observations or in situ electron microscopy or synchrotron-based methods in which cases the radiation type and dose are inextricably tied to the imaging basis itself. In this work we overcome this limitation by demonstrating integration of an X-ray source with an atomic force microscope to directly monitor radiolytically-driven interfacial chemistry at the nanoscale. We illustrate the value of in situ observations by examining effects of radiolysis on material adhesion forces in aqueous solution, as well as examining the production of alkali nitrates at the interface between an alkali halide crystal surface and air. For the examined salt-air interface, direct visualization under flexible experimental conditions greatly extends prior observations by enabling the transformation process to be followed comprehensively from source-to-sink with mass balance quantitation. Overall, our novel rad-AFM opens doors into understanding the dynamics of radiolytically-driven mass transfer and surface alteration at the nanoscale in real-time.

47 OTHER INSTRUMENTATION↗

Radiation shielding analysis of the small-angle X-ray scattering flight tube end station of APS upgrade project

The CSSI beamline of the APSU will have a 20.5 m long, 2.75 m diameter SS end station designed to accept pink beam. In this work, the radiation shielding analysis of this end station is analyzed using STAC8 and FLUKA codes. Effect of mirror properties such as reflectivity, coating, inclination and roughness as well as variation in the steel composition are also studied. 8 mm thick SS is found to be adequate if the source is defined by a pinhole and the white beam is reflected with two mirrors inclined at 3.0 mradian or more. The dose rates from monochromatic beams are found to be below the desired levels when the XOP calculated bandwidth (BW) are used while the use of a flat 0.1% BW requires the mirror inclinations to be above 2.5 mradian or more. STAC8 results are consistently higher than the FLUKA results by about 1.5–2.0 times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Satellites, core hole excitations, and spin-resolved electronic structure in the spectroscopy of half-metallic CrO 2

Photoelectron satellites—the structures appearing on the low kinetic or high binding-energy side of the “main” or “elastic” photopeak—betray the complex many-body interactions set in motion by the sudden creation of the core hole. In this work, we demonstrate, using the technologically important ferromagnetic half-metal CrO 2 , how such satellites can manifest themselves in other core-level spectroscopies of the material and how they can reveal important details pertinent to its electronic structure. Specifically, we identify a fluorescence satellite in the Cr 𝐿 3 resonant x-ray-emission spectra that radiates at a constant emission energy across the Cr 𝐿 3 x-ray edge with energy ≈1.3 eV above the ordinary valence fluorescence. Here, we provide evidence that this feature arises from the valence recombination of the Cr 2⁢𝑝 core hole “dressed” by the same shakeup charge-transfer process present in both the Cr x-ray photoelectron and the Cr x-ray absorption spectra with its energy uniquely measuring the exchange splitting of the Cr 3⁢𝑑 level. Further analysis of the x-ray emission data reveals three additional features that radiate at constant loss energy that are attributed to combinations of Cr 3⁢𝑑⁢(𝑡 2⁢𝑔 ) → Cr 3⁢𝑑⁢(𝑡 2⁢𝑔 ), charge-transfer O 2⁢𝑝→Cr 3⁢𝑑, and crystal-field Cr⁢ 3⁢𝑑⁡(𝑡 2⁢𝑔 )→Cr⁢ 3⁢𝑑⁡(𝑒 𝑔 ) excitations. These assignments and their energies are supported by density-functional theory calculations, the accuracy of which we demonstrate by hard x-ray valence-photoemission measurements. Atomic multiplet calculations, which include crystal-field effects, help interpret x-ray photoelectron and x-ray absorption spectra of the covalently mixed Cr ion. Resonant Cr K-𝐿 2,3 ⁢𝐿 2,3 Auger-electron emission spectra support a ligand-to-metal nature of the charge-transfer process while highlighting the charge sensitivity differences between photon-in/electron-out and photon-in/photon-out spectroscopies.

36 MATERIALS SCIENCE↗

The Industry's Long-term, Yet Near-term, Issues: The Need for Radiation Protection Professionals - 20266

Since the discovery of X-rays and radioactivity, the civil use of nuclear technology has thrived for more than a half-century and has matured to be safer and more efficient. A balance between radiological and non-radiological knowledge and experience has been gained and retained through the years. Nevertheless, a slowly developing gap has emerged during the past few decades. National and international data show a declining trend in the existence of health physics programs and associated enrollment and training, which directly impact the pipeline of radiation professionals (i.e., educators, technicians, researchers, and regulators). This decline can be attributed to many factors including the lack of scientific inquisitiveness, declining funding, and the perception that existing protocols are sufficiently protective. Decommissioning and dismantling nuclear facilities is a complex and multi-phased process that generates large quantities of various levels of radioactive waste. With multiple facilities reaching their end of operational life, and others being shut down for economic reasons, the current pipeline for radiation protection experts cannot meet the future's need. Consequently, international organizations have proposed a variety of programs to transfer knowledge of radiation protection principles and practice. While many change-oriented efforts to counteract this trend aim to promote mobility, this is just a partial solution to the actual issue: long-term availability. This paper suggests multidisciplinary collaborations with modern technologies as a path forward to educate young professionals on the diversity of radiation-related applications to retain expert knowledge and foster innovation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Flatfielding of hybrid pixel detectors in tender x-ray scattering

The ability of the soft matter interfaces beamline at National Synchrotron Light Source II to access x-ray energy in the tender x-ray regime, i.e., from 2.1 to 5 keV, enables new resonant x-ray scattering studies at the sulfur K-edge and others. We present a new approach to correct data acquired in the tender x-ray regime with a Pilatus3 detector in order to improve the data quality and to correct the various artifacts inherent to hybrid pixel detectors, such as variations in modules’ efficiency or noisy detector module junctions. Further, this new flatfielding significantly enhances the data quality and enables detection of weak scattering signals.

47 OTHER INSTRUMENTATION↗

Physical optics simulations for synchrotron radiation sources

Here we describe approaches to high-accuracy physical optics calculations used for the development of x-ray beamlines at synchrotron radiation sources, as well as simulation of experiments and processing of experimental data at some of these beamlines. We pay special attention to the treatment of the partial coherence of x rays, a topic of high practical importance for modern low-emittance high-brightness synchrotron radiation facilities. The approaches are based, to a large extent, on the works of Emil Wolf and co-authors, including the basic scalar diffraction theory and the coherent mode decomposition method. The presented simulation examples are related to the case of the novel Coherent Diffractive Imaging beamline that is currently under development at the National Synchrotron Light Source II at the Brookhaven National Laboratory.

36 MATERIALS SCIENCE↗

The High-energy Spectrum of the Nearby Planet-hosting Inactive Mid-M Dwarf LHS 3844

To fully characterize the atmospheres, or lack thereof, of terrestrial exoplanets, we must include the high-energy environments provided by their host stars. The nearby mid-M dwarf LHS 3844 hosts a terrestrial world that lacks a substantial atmosphere. We present a time-series UV spectrum of LHS 3844 from 1131 to 3215 Å captured by HST/COS. We detect one flare in the FUV that has an absolute energy of 8.96 ± 0.77 × 10{sup 28} erg and an equivalent duration of 355 ± 31 s. We extract the flare and quiescent UV spectra separately. For each spectrum, we estimate the Lyα flux using correlations between UV line strengths. We use Swift-XRT to place an upper limit on the soft X-ray flux and construct a differential emission model to estimate flux that is obscured by the interstellar medium. We compare the differential emission model flux estimates in the XUV to other methods that rely on scaling from the Lyα, Si iv, and N v lines in the UV. The XUV, FUV, and NUV flux of LHS 3844 relative to its bolometric luminosity is log{sub 10}(L {sub band}/L {sub Bol}) =−3.65, −4.16, and −4.48, respectively, for the quiescent state. These values agree with trends in high-energy flux as a function of stellar effective temperature found by the MUSCLES survey for a sample of early-M dwarfs. Many of the most spectroscopically accessible terrestrial exoplanets orbit inactive mid-to-late M dwarfs like LHS 3844. Measurements of M dwarf high-energy spectra are preferable for exoplanet characterization but are not always possible. The spectrum of LHS 3844 is a useful proxy for the current radiation environment for these worlds.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TMS XTRRA experiments on NIF

The study of x-ray induced rapid heating and the resulting material responses - (thermomechanical shock (TMS) and thermo-structural response (TSR)) - is important to our understanding of material behavior in extreme environments. A series of high conversion efficiency (XRCE) x-ray sources have been developed for the NIF laser facility ranging in fluence and spectral content. In conjunction with source development, we have developed a new XTRRA (X-ray Transport and Radiation Response Analysis) test cassette to hold a set of samples, each at equal distance from target chamber center (TCC) where the x-ray source is placed. Design and performance details of the x-ray sources is discussed elsewhere. Here, we describe the development and use of this TMS XTRRA test cassette. The XTRRA test cassette is a snout mounted on a NIF Diagnostic Instrument Manipulator (DIM) designed to position six samples equidistant from the x-ray source to assure uniform irradiation of all samples. Photon Displacement interferometry (PDI) is used to measure the displacement of the rear surface of each sample resulting from x-ray exposure on the front of the sample. This will help determine the x-ray generated impulse on the sample. The samples are retrieved from the snout after the shot for inspection and post-shot analysis including the measurement of sample ablated mass and engineering tests examining changes in the material structure. The data from experiments are compared to predictions from LLNL’s ASC codes and used to inform models implemented in these codes. Thus, XRCE x-ray sources with the XTRRA snout at the National Ignition Facility (NIF) laser at the Lawrence Livermore National Laboratory [1,2] provide the ability to expose a broad range of material samples directly to high x-ray fluence, measure shock transits, and recover the sample for further analysis post-shot.

36 MATERIALS SCIENCE↗

Disentangling x-ray dichroism and birefringence via high-purity polarimetry

High-brilliance synchrotron radiation sources have opened new avenues for x-ray polarization analysis that go far beyond conventional polarimetry in the optical domain. With linear x-ray polarizers in a crossed setting, polarization extinction ratios down to 10 -10 can be achieved. This renders the method sensitive to probe the tiniest optical anisotropies that would occur, for example, in strong-field quantum electrodynamics due to vacuum birefringence and dichroism. Here we show that high-purity polarimetry can be employed to reveal electronic anisotropies in condensed matter systems with utmost sensitivity and spectral resolution. Taking CuO and La 2 CuO 4 as benchmark systems, we present a full characterization of the polarization changes across the Cu K-absorption edge and their separation into dichroic and birefringent contributions. At diffraction-limited synchrotron radiation sources and x-ray lasers, where polarization extinction ratios of 10 -12 can be achieved, our method has the potential to assess birefringence and dichroism of the quantum vacuum in extreme electromagnetic fields.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Memory and CPU efficient coherent mode decomposition of partially coherent synchrotron radiation with subtraction of common quadratic phase terms

Application examples of a memory and CPU efficient coherent mode decomposition (CMD) method for wave-optics based simulation of the partially coherent undulator radiation propagation through a hard X-ray beamline in a 3rd generation synchrotron radiation source are presented. The high efficiency of the method is achieved thanks to the analytical treatment of the common quadratic phase terms that are developed in the phase of cross-spectral density (CSD) of partially coherent radiation at a distance from source. This treatment allows for a considerable, several orders of magnitude, reduction of the 4D CSD mesh density (and the memory occupied by the CSD) required for ensuring sufficient accuracies of wavefront propagation simulations with the modes produced by the CMD at a beamline entrance. This method, implemented in the “Synchrotron Radiation Workshop” open-source software, dramatically increases the feasibility of the CMD of 4D CSD for producing 2D coherent modes for a large variety of applications at storage rings and other types of radiation sources.

36 MATERIALS SCIENCE↗

Burst-mode chirped pulse amplification method

A method for increasing the MeV hot electron yield and secondary radiation produced by short-pulse laser-target interactions with an appropriately high or low atomic number (Z) target. Secondary radiation, such as MeV x-rays, gamma-rays, protons, ions, neutrons, positrons and electromagnetic radiation in the microwave to sub-mm region, can be used, e.g., for the flash radiography of dense objects.

Bude, Jeffrey D.↗