Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Wide Field Instrument Optical Stimulus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

345 records · Page 15

Materials And Processes Technical Information System (MAPTIS) LDEF materials database

The Materials and Processes Technical Information System (MAPTIS) is a collection of materials data which was computerized and is available to engineers in the aerospace community involved in the design and development of spacecraft and related hardware. Consisting of various database segments, MAPTIS provides the user with information such as material properties, test data derived from tests specifically conducted for qualification of materials for use in space, verification and control, project management, material information, and various administrative requirements. A recent addition to the project management segment consists of materials data derived from the LDEF flight. This tremendous quantity of data consists of both pre-flight and post-flight data in such diverse areas as optical/thermal, mechanical and electrical properties, atomic concentration surface analysis data, as well as general data such as sample placement on the satellite, A-O flux, equivalent sun hours, etc. Each data point is referenced to the primary investigator(s) and the published paper from which the data was taken. The MAPTIS system is envisioned to become the central location for all LDEF materials data. This paper consists of multiple parts, comprising a general overview of the MAPTIS System and the types of data contained within, and the specific LDEF data element and the data contained in that segment.

John M. Davis

Bifurcation of Rotating Liquid Drops: Results From USML-1 Experiments in Space

Experiments on rotational bifurcation of liquid drops, in which the drops were levitated and spun using acoustic fields in a low-gravity environment, were conducted during the first United States Microgravity Laboratory (USML-1) Space Shuttle flight. The experiments have successfully resolved the discrepancies existing between the previous experimental results and the theoretical predictions. In the case of a spherical drop, for which theory exists, the results agree well with the predictions. In the case of flattened drops, the experiments have established a family of curves, with the spherical drop as the limiting case.

T G Wang

Apollo-Soyuz Test Project: Preliminary Science Report

This document summarizes the experimental concepts and preliminary analyses (as of December 1975) for each of the 28 scientific experiments conducted during the Apollo-Soyuz Test Project from July 15 to 24, 1975. The scientific topics are X- ray and extreme ultraviolet astronomy, solar astronomy, gamma- ray detectors, Earth studies (including the upper atmosphere, meteorological phenomena, hydrology, oceanography, geology, desert studies, and gravity field studies), microbiology, heavy cosmic particle interaction with live cells, vestibular system studies, and materials processing (including high-temperature and ambient-temperature processing of industrial materials and electrophoretic processing of biological materials) .

Microbiology

On the Stability Analysis of Astrophysical Cooling Functions

To model the temperature evolution of optically thin astrophysical environments at MHD scales, radiative and collisional cooling rates are typically either pretabulated or fit into a functional form and then input into MHD codes as a radiative loss function. Thermal balance requires estimates of the analogous heating rates, which are harder to calculate, and due to uncertainties in the underlying dissipative heating processes these rates are often simply parameterized. The resulting net cooling function defines an equilibrium curve that varies with density and temperature. Such cooling functions can make the gas prone to thermal instability (TI), which will cause departures from equilibrium. There has been no systematic study of thermally unstable parameter space for nonequilibrium states. Motivated by our recent finding that there is a related linear instability, catastrophic cooling instability, that can dominate over TI, here we carry out such a study. We show that Balbus instability criteria for TI can be used to define a critical cooling rate, Λc, that permits a nonequilibrium analysis of cooling functions through the mapping of TI zones. We furthermore illustrate how thermal conduction modifies the shape of TI zones. Upon applying a Λc-based stability analysis to coronal loop simulations, we find that loops undergoing periodic episodes of coronal rain formation are linearly unstable to catastrophic cooling instability, while TI is stabilized by thermal conduction.

Amanda Stricklan

Integrated Computational Materials Engineering (ICME) Capability Maturity Levels for Ecosystems Enabling Digital Transformation

Digital engineering (DE) and integrated computational materials engineering (ICME) are widely recognized as critical enablers of faster, more affordable, and more reliable aerospace systems. However, many organizations have struggled to realize the promised return on investment (ROI) from digital initiatives. A primary reason is the absence of a shared, decision-focused framework that distinguishes simple digitization of existing workflows from true digital transformation that fundamentally changes how engineering decisions are made. This paper introduces an ICME capability maturity framework that fills this gap. The framework defines six cumulative ICME capability maturity levels (CMLs), explicitly tied to decision authority, engineering integration, optimization, and uncertainty management across material, process, structure, and performance scales. It is designed to complement established readiness metrics such as technology readiness levels (TRLs), manufacturing readiness levels (MRLs), and integration readiness levels (IRLs), by addressing a missing dimension: the conditions required for model-informed decision authority across scales. A unifying figure and capability table illustrate the six-level ICME Capability Maturity Framework, showing how organizations progress from digitization—with limited or negative ROI—to true digital transformation, where ICME-enabled workflows deliver measurable improvements in decision quality, cycle time, risk reduction, and reuse. The framework is intended for both technical practitioners and executive leadership, providing a common language to assess current state, guide roadmaps, align software ecosystem investments, and set realistic expectations for digital transformation outcomes. A regulatory-relevant statement clarifying the relationship between ICME capability and existing certification frameworks is provided.

ICME

Hot Water, Cold Reality: Experimental Analysis of Sorption Constraints in Iodine Filtration Media Under Heated-Water Conditions

Iodine has been widely employed as a residual biocide in potable water applications during crewed missions. Unlike other biocides, it is essential to remove iodine from drinking water prior to consumption, as its biocidal concentration raises health concerns. Consequently, effectively removing iodine species from water is a critical step in potable water processing. Although the non-biocided heated leg has not violated microbial specifications on the International Space Station, any wetted volume lacking biocide presents potential risks for long‑duration exploration missions and for systems that are sensitive to microbial growth/contamination. Recent assessments indicate, however, that iodine‑removal performance may degrade under elevated temperature conditions, such as those required for dispensing hot water for food preparation. This reduction in efficacy appears to stem from both the potential physical degradation of filtration media and the temperature‑dependent behavior of adsorption processes. To investigate the influence of water temperature on the efficacy of filtration media for iodine removal, a series of adsorption capacity tests were conducted at both room temperature and elevated temperatures (90 °C). These experiments aimed to benchmark the performance of the adsorbents that constitute the ACTEX filter in the ISS’s potable water dispenser. The findings of this study provide critical insights into the iodine filtration process, verify the potential performance shortfall under elevated temperature conditions, and establish the basis for defining new absorbent requirements to ensure reliable iodine removal in future mission architectures.

drinking water

NASA University Research Centers: Technical Advances in Aeronautics, Space Sciences and Technology, Earth Systems Sciences, Global Hydrology, and Education

This volume chronicles the proceedings of the 1998 NASA University Research Centers Technical Conference (URC-TC '98), held on February 22-25, 1998, in Huntsville, Alabama. The University Research Centers (URCS) are multidisciplinary research units established by NASA at 11 Historically Black Colleges or Universities (HBCU's) and 3 Other Minority Universities (OMU's) to conduct research work in areas of interest to NASA. The URC Technical Conferences bring together the faculty members and students from the URC's with representatives from other universities, NASA, and the aerospace industry to discuss recent advances in their fields.

T L Coleman

Hot Water, Cold Reality: Experimental Analysis of Sorption Constraints in Iodine Filtration Media Under Heated-Water Conditions

Iodine has been widely employed as a residual biocide in potable water applications during crewed missions. Unlike other biocides, it is essential to remove iodine from drinking water prior to consumption, as its biocidal concentration raises health concerns. Consequently, effectively removing iodine species from water is a critical step in potable water processing. Although the non-biocided heated leg has not violated microbial specifications on the International Space Station, any wetted volume lacking biocide presents potential risks for long‑duration exploration missions and for systems that are sensitive to microbial growth/contamination. Recent assessments indicate, however, that iodine‑removal performance may degrade under elevated temperature conditions, such as those required for dispensing hot water for food preparation. This reduction in efficacy appears to stem from both the potential physical degradation of filtration media and the temperature‑dependent behavior of adsorption processes. To investigate the influence of water temperature on the efficacy of filtration media for iodine removal, a series of adsorption capacity tests were conducted at both room temperature and elevated temperatures (90 °C). These experiments aimed to benchmark the performance of the adsorbents that constitute the ACTEX filter in the ISS’s potable water dispenser. The findings of this study provide critical insights into the iodine filtration process, verify the potential performance shortfall under elevated temperature conditions, and establish the basis for defining new absorbent requirements to ensure reliable iodine removal in future mission architectures.

iodine

Fluid-Thermal-Structural Interactions Induced by an Asymmetric Shock-Wave/Boundary-Layer Interaction in a Mach-6 Compression Corner

An experimental study is conducted of the fluid-thermal-structural interaction of a clamped compliant panel exposed to a three dimensional shock-wave/boundary-layer interaction (SWBLI) induced by a Mach-6 compression ramp with a spanwise nonuniform incoming boundary layer. The nonuniform boundary layer was produced by placing trips on one side of the upstream flat plate, resulting in largely turbulent flow on the tripped side and transitional flow on the untripped side. Measurements of the flowfield confirmed that the tripped boundary layer contained elevated levels of unsteadiness, and the SWBLI was observed to vary from attached to fully separated as the ramp angle was increased from 10◦ to 38◦; the separation region on the tripped side of the panel was noticeably smaller, showing the elevated turbulence levels of the tripped-side flow to remain relatively localized rather than diffusing across the whole model. Full-field, time-resolved panel deformations were measured using high-speed photogrammetry and the vibrational response at each compression angle was characterized. Although the measured modes conformed largely to those from classical clamped-plate theory, some skewing of the mode shapes was observed. IR thermography highlighted regions of the compliant region where elevated temperatures were likely to promote thermal softening effects to the transient panel response. The quasi-static deformation and stress field was used to characterize the internal stress factor of each mode and showed a meaningful relationship between transient panel response and stress contained within each mode: modes with antinodes lying in high-stress areas of the plate tended to exhibit increases in vibrational frequency and decreases in vibrational power, whereas the opposite was true for modes with antinodes in low-stress areas.

Spectral Proper Orthogonal Decomposition

Guidelines for Schlieren Systems at Langley Research Center

The original Langley Working Paper (LWP 448) published on July 27th, 1967, provided guidance to NASA Langley Research Center personnel on how to set up conventional path-integrated schlieren flow visualization systems and what pitfalls could be expected with such setups. The guidance and information contained in the document continues to be used for schlieren setups at NASA Langley Research Center to this day. The most commonly used method of flow visualization in supersonic wind tunnels is the schlieren method, or method of striae. At the Langley Research Center, this method is so commonly used that it has come to be regarded somewhat as merely another piece of instrumentation which is to be maintained by service people, and which is too mysteriously complicated to be touched by tunnel personnel. This should not be the case. High-quality results from a schlieren system can only be obtained by having personnel on the tunnel staff who are well-informed on the subject and who have the time and the interest to do a good job of adjustment. This paper is a discussion in practical terms, of some of the points to be considered and the pitfalls that may be encountered in designing, setting up and using a working schlieren system. It is directed specifically toward helping specify and install a Z-type mirror system. It is hoped that the material will be of assistance to facilities throughout the Center and NASA and that users of the schlieren method will be inspired to the point of training people in the adjustment of the systems in use at their facilities.

Langley Working Papers

A Simplified Model of VIPER Thermal Management System. Part II: Integrated Vehicle

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) thermal management system (TMS) relies on four loop heat pipes (LHPs) to transport electronic waste heat to the vehicle cooling radiative surface and avoid overheating. The TMS has also ten constant conductance heat pipes (CCHPs) dedicated to balance the thermal load within the internal environment where the avionics boxes are mounted, also called warm electronic box (WEB), and to transport the heat from two of the science payload instruments. The TMS also uses two thermal straps to thermally link the batteries to the WEB. These thermal components, in addition to heaters, thermostat, multi-layer insulation (MLIs), and isolators forms the core of the VIPER TMS. The complex heat transport balance managed by the TMS is challenging to characterize and model. The more fidelity and granularity of a model, the more costly the computational resources needed and the longer the simulation and modeling time. When the priority is to provide quick but reliable assessments of the thermal performance or real time thermal feedback for training of console operators, simplified modeling tools are needed. To satisfy that need, this paper describes the effort to develop and correlate a model of VIPER TMS based on control volume approach. The correlation effort in particular focuses on hibernation, cold thermal balance, and hot thermal balance data from the integrated vehicle thermal vacuum (TVAC) test. Thus, the correlated model captures the heat leaks during hibernations and the performance at two extremes, bounding, operating scenarios.

Loop Heat Pipe

A Simplified Model of VIPER Thermal Management System. Part II: Integrated Vehicle

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) thermal management system (TMS) relies on four loop heat pipes (LHPs) to transport electronic waste heat to the vehicle cooling radiative surface and avoid overheating. The TMS has also ten constant conductance heat pipes (CCHPs) dedicated to balance the thermal load within the internal environment where the avionics boxes are mounted, also called warm electronic box (WEB), and to transport the heat from two of the science payload instruments. The TMS also uses two thermal straps to thermally link the batteries to the WEB. These thermal components, in addition to heaters, thermostat, multi-layer insulation (MLIs), and isolators forms the core of the VIPER TMS. The complex heat transport balance managed by the TMS is challenging to characterize and model. The more fidelity and granularity of a model, the more costly the computational resources needed and the longer the simulation and modeling time. When the priority is to provide quick but reliable assessments of the thermal performance or real time thermal feedback for training of console operators, simplified modeling tools are needed. To satisfy that need, this paper describes the effort to develop and correlate a model of VIPER TMS based on control volume approach. The correlation effort in particular focuses on hibernation, cold thermal balance, and hot thermal balance data from the integrated vehicle thermal vacuum (TVAC) test. Thus, the correlated model captures the heat leaks during hibernations and the performance at two extremes, bounding, operating scenarios.

Thermal Modeling

The Entry Plasma Sheath and Its Effects on Space Vehicle Electromagnetic Systems, Volume 1

This symposium is the fourth in a series on the plasma sheath. The first three were held in Boston, Massachusetts, and were sponsored by the Air Force Cambridge Research Laboratories. The papers included in the symposium cover theoretical and experimental results of research and flight tests of many different specific aspects of the general problem of plasma sheath degradation of reentry vehicle electromagnetic systems. Only the newer advances and more recent developments in the field are included in the Fourth Plasma Sheath Symposium, with no particular attempt being made to review the general background and history of the problem or to cover those aspects discussed in the previous symposia. Flight data from both NASA and DOD programs are included.

Source record

A Comparison of Doppler Lidar Wind Sensors for Earth-Orbit Global Measurement Applications

Now, there are four Doppler lidar configurations which are being promoted for the measurement of tropospheric winds: (1) the coherent CO2 Lidar, operating in the 9 micrometer region using a pulsed, atmospheric pressure CO2 gas discharge laser transmitter, and heterodyne detection; (2) the coherent Neodymium doped YAG or Glass Lidar, operating at 1.06 micrometers, using flashlamp or diode laser optical pumping of the solid state laser medium, and heterodyne detection; (3) the Neodymium doped YAG/Glass Lidar, operating at the doubled frequency (at 530 nm wavelength), again using flashlamp or diode laser pumping of the laser transmitter, and using a high resolution tandem Fabry-Perot filter and direct detection; and (4) the Raman shifted Xenon Chloride Lidar, operating at 350 nm wavelength, using a pulsed, atmospheric pressure XeCl gas discharge laser transmitter at 308 nm, Raman shifted in a high pressure hydrogen cell to 350 nm in order to avoid strong stratospheric ozone absorption, also using a high resolution tandem Fabry-Perot filter and direct detection. Comparisons of these four systems can include many factors and tradeoffs. The major portion of this comparison is devoted to efficiency. Efficiency comparisons are made by estimating the number of transmitted photons required for a single pulse wind velocity estimate of + or - 1 m/s accuracy in the middle troposphere, from an altitude of 800 km, which is assured to be reasonable for a polar orbiting platform.

Robert T Menzies

Assessing the Adhesion of Nanofibrous PVDF-HFP as Passive Thermal Control Coatings for the Extraterrestrial Storage of Cryogenic Propellants

Cryogenic propellant passive thermal management techniques in space are essential complements to active thermal management methods, helping reduce absolute dependence on the latter. Particularly, materials with superior optical properties (high solar reflectance and infrared emittance) would be beneficial for passive thermal control to reject most of the incident solar radiation and enhance thermal emission from the storage tank, leading to self-cooling. We developed a nanofibrous, porous passive thermal control material by electrospinning polyvinylidene fluoride-co-hexafluoropropylene (PVDF-HFP) co-polymer onto an aluminum foil substrate. The material exhibits a very high solar reflectance (>99%) and infrared emittance (~86%) when characterized in the ultraviolet-visible-near infrared and mid-infrared wavelengths. This study focuses on the adhesion of the nanofibrous PVDF-HFP to the substrate. We incorporated in-lab fabricated and commercial adhesives, under normal room conditions, between the nanofibers and the aluminum foil substrate to improve their adhesion. Some samples were also exposed to space-like conditions – vacuum and thermal cycling, to investigate their effects on the strengths of adhesives. Subsequently, adhesion peel tests were conducted on all the samples to assess the peel strengths of the bonds. Peel test strengths after space environment conditioning of the adhesives were generally higher than those observed in the pristine, unaged samples. The results are discussed in this study.

Chieloka Ibekwe

FAST Spacecraft Battery Design and Performance

The Fast Auroral Snapshot (FAST) Explorer spacecraft is to study the physical processes that produce the aurora borealis and aurora australis. It is a unique plasma physics experiment that will take fundamental measurements of the magnetic and electrical fields. This investigation will add significantly to our understanding of the near-earth space environments and its effect. The FAST has a 1 year requirement and 3-year goal for its mission life in low earth orbit. The FAST power power system topology is a Direct Energy Transfer (DET) system based on the SAMPEX design. The FAST flight battery supplies power to the satellite during pre-launch operations, the launch phase, the eclipse periods for all mission phases, and when the load is about 50 watts.

Jung, David S.

Atacama Cosmology Telescope A Measurement of Galaxy Cluster Temperatures Through Relativistic Corrections to the Thermal Sunyaev-Zeldovich Effect

The high electron temperature in galaxy clusters (> 1 keV or > 107 K) leads to corrections at the level of a few percent in their thermal Sunyaev-Zeldovich effect signatures. Both the size and frequency dependence of these corrections, which are known as relativistic temperature corrections, depend upon the temperature of the objects. In this work we exploit this effect to measure the average temperature of a stack of Compton-y selected clusters. Specifically, we apply the “spectroscopic method” and search for the temperature that best fits the clusters’ signal measured at frequencies from 30 to 545 GHz by the Atacama Cosmology Telescope and Planck satellite. We measure the average temperature of clusters detected in the Atacama Cosmology Telescope maps to be 8.5 2.4 keV, with an additional systematic error of comparable amplitude dominated by passband uncertainty. Upcoming surveys, such as the Simons Observatory and CMB-S4, have the potential to dramatically improve upon these measurements and thereby enable precision studies of cluster temperatures with millimeter observations. The key challenge for future observations will be mitigating instrumental systematic effects, which already limit this analysis.

William R Coulton

Chapter 21 - Avionics

This Section presents general guidance for flight testing of avionics systems. Due to the complex and ever changing nature of avionics systems, specific detailed test methods and analysis techniques are left to current and future system specific AGARDographs such as references 21-1 and 21-2. This section will provide descriptions of test methods which are generic to most current and future avionics systems. The field of avionics systems was divided into four general categories (autopilot, navigation and communication, offensive, and defensive) and a fifth overall test category of integration. This was accomplished only for the convenience in presenting the material. These categories are not meant to encompass all avionics systems but are intended to be sufficiently general to enable a systematic discussion of the testing of the basic types of avionics systems.

Ron Mahlum