Shuttle Return-to-Flight IH-108 Aerothermal Test at CUBRC - Flow Field Calibration and CFD

This paper discusses one specific aspect of the Shuttle Retrun-To-Flight IH-108 Aerothermal Test at CUBRC, the test flow field calibration. It showed the versatility of the CUBRC LENS II wind tunnel for an aerothermal test with unique and demanding requirements. CFD analyses were used effectively to extend the test range at the low end of the Mach range. It demonstrated how ground test facility and CFD synergy can be utilitzed iteratively to enhance the confidence in the fedility of both tools. It addressed the lingering concerns of the aerothermal community on use of inpulse facility and CFD analysis. At the conclusion of the test program, members from the NASA Marshall (MSFC), CUBRC and USA (United Space Alliance) Consultants (The Grey Beards) were asked to independently verify the flight scaling data generated by Boeing for flight certification of the re-designed external tank (ET) components. The blind test comparison showed very good results. A more comprehensive discussion of the topics in this paper can be found in Chapter 6 of Reference [1]. The overall aspect of the test program has been discussed in an AIAA paper by Tim Wadhams [2]. The Shuttle Ascent Stack performance and related issues discussed in the Report [1] are not included in this paper. No ITAR data is included in this paper.

Lau, Kei Y.↗

Full Aerothermal Characterization of the NASA Glenn Research Center 9- by 15-Foot Low-Speed Wind Tunnel (2019 Test)

Following completion of the 9- by 15-Foot Low Speed Wind Tunnel acoustic improvement modification project, a characterization of the flow field throughout the 9- by 15-foot test section was conducted in 2019. The acoustic improvement modifications project included several large-scale tunnel loop modifications and reconstruction of the 9- by 15-Foot Low Speed Wind Tunnel test section and diffuser to decrease the noise floor in the test section. Data were collected at three cross-sectional planes in the 9- by 15-ft test section using a 15-foot traversing calibration rake and a set of eight boundary layer rakes. The data from the characterization test were used to generate calibration relationships for facility operation and understand the flow quality in the new test section, including uniformity, flow angularity, turbulence intensity, and boundary layer characteristics. Additionally, the subsonic quick check rake was used to baseline the check calibration data set for the new test section.

Wind↗

Hydraulic Calibrator for Strain-Gauge Balances

Instrument for calibrating strain-gauge balances uses hydraulic actuators and load cells. Eliminates effects of nonparallelism, nonperpendicularity, and changes of cable directions upon vector sums of applied forces. Errors due to cable stretching, pulley friction, and weight inaccuracy also eliminated. New instrument rugged and transportable. Set up quickly. Developed to apply known loads to wind-tunnel models with encapsulated strain-gauge balances, also adapted for use in calibrating dynamometers, load sensors on machinery and laboratory instruments.

Skelly, Kenneth↗

Thermal and Pressure Characterization of a Wind Tunnel Force Balance Using the Single Vector System

Wind tunnel research at NASA Langley Research Center s 31-inch Mach 10 hypersonic facility utilized a 5-component force balance, which provided a pressurized flow-thru capability to the test article. The goal of the research was to determine the interaction effects between the free-stream flow and the exit flow from the reaction control system on the Mars Science Laboratory aeroshell during planetary entry. In the wind tunnel, the balance was exposed to aerodynamic forces and moments, steady-state and transient thermal gradients, and various internal balance cavity pressures. Historically, these effects on force measurement accuracy have not been fully characterized due to limitations in the calibration apparatus. A statistically designed experiment was developed to adequately characterize the behavior of the balance over the expected wind tunnel operating ranges (forces/moments, temperatures, and pressures). The experimental design was based on a Taylor-series expansion in the seven factors for the mathematical models. Model inversion was required to calculate the aerodynamic forces and moments as a function of the strain-gage readings. Details regarding transducer on-board compensation techniques, experimental design development, mathematical modeling, and wind tunnel data reduction are included in this paper.

Lynn, Keith C.↗

Validation of Shadowgraph Spectral Analysis using an SLS Block 2 Wind-Tunnel Model

A flow quantification method has previously been developed that uses high-speed shadowgraph images to extract frequency content of a transonic flow field around a wind-tunnel model. In this method, a classical spectral analysis is performed on a set of shadowgraph image pixels to identify their intensity fluctuation frequencies. The spatial change of the image intensity is related to the second derivative of the density gradient. Examining the change of the density gradient as a function of time can be used to understand the flow field pressure fluctuations. Pressure measurements collected during a Booster Obsolescence Life Extension Forward Attachment Structure Trade Study Test are used to calibrate the shadowgraph-based measurements. The test was performed at the NASA Ames Research Center Unitary Plan Wind Tunnel 11- by 11-foot test section and investigated aerodynamic environment downstream of various booster forward attachment hardware geometries of the Space Launch System Block 2 Cargo configuration. Time-correlated shadowgraph video and model surface pressure measurements were acquired during the test and served as an ideal opportunity to calibrate and validate the shadowgraph image intensity method.

Shadowgraph↗

Evaluation tests of platinum resistance thermometers for a cryogenic wind tunnel application

Thirty-one commercially designed platinum resistance thermometers were evaluated for applicability to stagnation temperature measurements between -190 C and +65 C in the Langley Research Center's National Transonic Facility. Evaluation tests included X-ray shadowgraphs, calibrations before and after aging, and time constant measurements. Two wire-wound low thermal mass probes of a conventional design were chosen as most suitable for this cryogenic wind tunnel application.

Germain, E. F.↗

Photogrammetry Applied to Wind Tunnel Testing

In image-based measurements, quantitative image data must be mapped to three-dimensional object space. Analytical photogrammetric methods, which may be used to accomplish this task, are discussed from the viewpoint of experimental fluid dynamicists. The Direct Linear Transformation (DLT) for camera calibration, used in pressure sensitive paint, is summarized. An optimization method for camera calibration is developed that can be used to determine the camera calibration parameters, including those describing lens distortion, from a single image. Combined with the DLT method, this method allows a rapid and comprehensive in-situ camera calibration and therefore is particularly useful for quantitative flow visualization and other measurements such as model attitude and deformation in production wind tunnels. The paper also includes a brief description of typical photogrammetric applications to temperature- and pressure-sensitive paint measurements and model deformation measurements in wind tunnels.

Liu, Tian-Shu↗

Heat Flux Sensor Testing

This viewgraph presentation provides information on the following objectives: Developing secondary calibration capabilities for MSFC's (Marshall Space Flight Center) Hot Gas Facility (HGF), a Mach 4 Aerothermal Wind Tunnel; Evaluating ASTM (American Society for Testing and Materials) slug/ thinskin calorimeters against current HGF heat flux sensors; Providing verification of baselined AEDC (Arnold Engineering Development Center) / Medtherm gage calibrations; Addressing future calibration issues involving NIST (National Institute of Standards and Technology) certified radiant gages.

Clark, D. W.↗

Validation of Shadowgraph Spectral Analysis using an SLS Block 2 Wind-Tunnel Model

A flow quantification method has previously been developed that uses high-speed shadowgraph images to extract frequency content of a transonic flow field around a wind-tunnel model. In this method, a classical spectral analysis is performed on shadowgraph video pixels to identify their intensity fluctuation frequencies. The spatial change of the image intensity is related to the second derivative of the density gradient. Examining the change of the density gradient as a function of time can be used to understand the flow-field pressure fluctuations. Time-varying pressure measurements collected during a Space Launch System (SLS) unsteady aerodynamic test of an advanced Block 2 booster design are used to calibrate the shadowgraph-based measurements. The test was performed at the NASA Ames Research Center Unitary Plan Wind Tunnel 11- by 11-foot test section and investigated the aerodynamic environment downstream of candidate booster forward attachment hardware geometries of the SLS Block 2 Cargo configuration. Time-correlated shadowgraph video and model surface pressure measurements were acquired during the test and served as an ideal opportunity to calibrate and validate the shadowgraph image intensity method.

Shadowgraph↗

Validation of Shadowgraph Spectral Analysis using an SLS Block 2 Wind-Tunnel Model

A flow quantification method has previously been developed that uses high-speed shadowgraph images to extract frequency content of a transonic flow field around a wind-tunnel model. In this method, a classical spectral analysis is performed on shadowgraph video pixels to identify their intensity fluctuation frequencies. The spatial change of the image intensity is related to the second derivative of the density gradient. Examining the change of the density gradient as a function of time can be used to understand the flow-field pressure fluctuations. Time-varying pressure measurements collected during a Space Launch System (SLS) unsteady aerodynamic test of an advanced Block 2 booster design are used to calibrate the shadowgraph-based measurements. The test was performed at the NASA Ames Research Center Unitary Plan Wind Tunnel 11- by 11-foot test section and investigated the aerodynamic environment downstream of candidate booster forward attachment hardware geometries of the SLS Block 2 Cargo configuration. Time-correlated shadowgraph video and model surface pressure measurements were acquired during the test and served as an ideal opportunity to calibrate and validate the shadowgraph image intensity method.

Shadowgraph↗

CFD code calibration and inlet-fairing effects on a 3D hypersonic powered-simulation model

A three-dimensional (3D) computational study has been performed addressing issues related to the wind tunnel testing of a hypersonic powered-simulation model. The study consisted of three objectives. The first objective was to calibrate a state-of-the-art computational fluid dynamics (CFD) code in its ability to predict hypersonic powered-simulation flows by comparing CFD solutions with experimental surface pressure dam. Aftbody lower surface pressures were well predicted, but lower surface wing pressures were less accurately predicted. The second objective was to determine the 3D effects on the aftbody created by fairing over the inlet; this was accomplished by comparing the CFD solutions of two closed-inlet powered configurations with a flowing-inlet powered configuration. Although results at four freestream Mach numbers indicate that the exhaust plume tends to isolate the aftbody surface from most forebody flowfield differences, a smooth inlet fairing provides the least aftbody force and moment variation compared to a flowing inlet. The final objective was to predict and understand the 3D characteristics of exhaust plume development at selected points on a representative flight path. Results showed a dramatic effect of plume expansion onto the wings as the freestream Mach number and corresponding nozzle pressure ratio are increased.

Huebner, Lawrence D.↗

CFD Code Calibration and Inlet-Fairing Effects On a 3D Hypersonic Powered-Simulation Model

A three-dimensional (3D) computational study has been performed addressing issues related to the wind tunnel testing of a hypersonic powered-simulation model. The study consisted of three objectives. The first objective was to calibrate a state-of-the-art computational fluid dynamics (CFD) code in its ability to predict hypersonic powered-simulation flows by comparing CFD solutions with experimental surface pressure data. Aftbody lower surface pressures were well predicted, but lower surface wing pressures were less accurately predicted. The second objective was to determine the 3D effects on the aftbody created by fairing over the inlet; this was accomplished by comparing the CFD solutions of two closed-inlet powered configurations with a flowing- inlet powered configuration. Although results at four freestream Mach numbers indicate that the exhaust plume tends to isolate the aftbody surface from most forebody flow- field differences, a smooth inlet fairing provides the least aftbody force and moment variation compared to a flowing inlet. The final objective was to predict and understand the 3D characteristics of exhaust plume development at selected points on a representative flight path. Results showed a dramatic effect of plume expansion onto the wings as the freestream Mach number and corresponding nozzle pressure ratio are increased.

Huebner, Lawrence D.↗

Boundary-Layer Transition Detection in Cryogenic Wind Tunnel Using Fluorescent Paints

Luminescent molecular probes imbedded in a polymer binder form a temperature or pressure paint. On excitation by light of the proper wavelength, the luminescence, which is quenched either thermally or by oxygen, is detected by a camera or photodetector. From the detected luminescent intensity, temperature and pressure can be determined. The basic photophysics, calibration, accuracy and time response of a luminescent paints is described followed by applications in low speed, transonic, supersonic and cryogenic wind tunnels and in rotating machinery.

Sullivan, John↗

National Transonic Facility Wall Pressure Calibration Using Modern Design of Experiments (Invited)

The Modern Design of Experiments (MDOE) has been applied to wind tunnel testing at NASA Langley Research Center for several years. At Langley, MDOE has proven to be a useful and robust approach to aerodynamic testing that yields significant reductions in the cost and duration of experiments while still providing for the highest quality research results. This paper extends its application to include empty tunnel wall pressure calibrations. These calibrations are performed in support of wall interference corrections. This paper will present the experimental objectives, and the theoretical design process. To validate the tunnel-empty-calibration experiment design, preliminary response surface models calculated from previously acquired data are also presented. Finally, lessons learned and future wall interference applications of MDOE are discussed.

Underwood, Pamela J.↗

Development, fabrication and calibration of a porous surface microphone in an aerofoil

The development of a porous surface microphone in an airfoil intended to measure acoustic signals in a turbulent airflow and to minimize the flow noise is described. The sensor because of its airfoil operates over a wide range of yaw angles and flow velocities without excessive flow noise. The acoustic properties of the porous materials used in the airfoil sensor and their effects on the frequency response of the sensor were analyzed and tested. An accurate airfoil was selected, having a smaller thickness-to-chord ratio and an airfoil sensor was designed. The sensor was calibrated acoustically and its flow noise evaluated in the quiet BBN wind tunnel at flow velocities up to 70 m/sec. Results are presented.

Noiseux, D. U.↗

Static pressure orifice system testing method and apparatus

A method and apparatus are presented for pressure testing the static pressure orifices and associated connections used in wind tunnels. A cylindrical module, having in one end an open hemispherical calibration pressure chamber separated from and surrounded by an annular vacuum chamber is placed over the orifice of the system to be tested. O-rings ensure seating and a vacuum seal between the chambered end of the module and the surface around the orifice: one O-ring separates the outer chamber from the outside environment. Ports lead from each of the chambers out the other end of the module to tubes connected to a control box consisting of calibration pressure and vacuum supply lines, bleeder valves, and gauges.

Culotta, R. F.↗

Sediment-transport experiments in zero-gravity

One of the important parameters in the analysis of sediment entrainment and transport is gravitational attraction. The availability of a laboratory in Earth orbit would afford an opportunity to conduct experiments in zero and variable gravity environments. Elimination of gravitational attraction as a factor in such experiments would enable other critical parameters (such as particle cohesion and aerodynamic forces) to be evaluated much more accurately. A Carousel Wind Tunnel (CWT) is proposed for use in conducting experiments concerning sediment particle entrainment and transport in a space station. In order to test the concept of this wind tunnel design a one third scale model CWT was constructed and calibrated. Experiments were conducted in the prototype to determine the feasibility of studying various aeolian processes and the results were compared with various numerical analysis. Several types of experiments appear to be feasible utilizing the proposed apparatus.

Iversen, J. D.↗