Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WHISPER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Nonlinear optical sub-bandgap excitation of ZnO-based photonic resonators

Zinc oxide (ZnO) is a versatile candidate for photonic devices due to its highly efficient optical emission. However, for pumping of ZnO photonic devices UV-sources are required. Here, we investigate the alternative usage of widely available pulsed near-infrared (NIR)-sources and compare the efficiency of linear and nonlinear excitation processes. We found that bulk ZnO, ZnO thin films grown by molecular beam epitaxy, and ZnO/SiO{sub 2} microdisk devices exhibit strong nonlinear response when excited with NIR pulses (λ ≈ 1060 nm). In addition, we show that the ZnO/SiO{sub 2} microdisks exhibit sharp whispering gallery modes over the blue-yellow part of the visible spectrum for both excitation conditions and high Q-factors up to Q = 4700. The results demonstrate that nonlinear excitation is an efficient way to pump ZnO photonic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiative rate modification in CdSe quantum dot-coated microcavity

Whispering gallery modes (WGMs) of the microparticles with spherical or cylindrical symmetry have exceptionally high quality factors and small mode volume. Quantum dots (QDs) are zero dimensional systems with variable band gap as well as luminescent properties with applications in photonics. In this paper, the WGMs have been observed in the luminescence spectra of CdSe QD-coated single silica microspheres. Theoretical estimations of variation of resonance frequency, electric field, and Q-values have been done for a multilayer coating of QDs on silica microspheres. Observed WGMs have been identified for their mode number and polarization using Mie theory. Broadening of modes due to material absorption has been observed. Splitting of WGMs has also been observed due to coherent coupling of counter propagating waves in the microcavity due to the presence of QDs. At room temperature, the time-resolved study indicates the modification of the radiative rate due to coupling of WGMs of the microcavity-QD hybrid system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Apertureless SPM method of light detection

We demonstrate the effect of infrared (IR) illumination on mechanical resonance frequency of scanning probe microscope (SPM) probe. The analytical estimations permit to relate the observed effect with the SPM-probe heating by IR-radiation. This effect can be used for the SPM mapping of IR-radiation spatial distribution on the emitting surfaces. The proposed method demonstrates high sensitivity to the infrared radiation and lateral resolution in the sub-micron range. It was applied to visualize complex spatial structure of lasing modes on the mirror of whispering-gallery mode GaSb/GaAlAsSb/GaInAsSb laser.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Operation of an InAs quantum-dot embedded GaAs photonic crystal slab waveguide laser by using two-photon pumping for photonics integrated circuits

The development of small sized laser operating above room temperature is important in the realization of optical integrated circuits. Recently, micro-lasers consisting of photonic crystals (PhCs) and whispering gallery mode cavities have been demonstrated. Optically pumped laser devices could be easily designed using photonic crystal-slab waveguides (PhC-WGs) with an air-bridge type structure. In this study, we observe lasing at 1.3μm from two-photon pumped InAs-quantum-dots embedded GaAs PhC-WGs above room temperature. This type of compact laser shows promise as a new light source in ultra-compact photonics integrated circuits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Temperature characteristics of epitaxially grown InAs quantum dot micro-disk lasers on silicon for on-chip light sources

Temperature characteristics of optically pumped micro-disk lasers (MDLs) incorporating InAs quantum dot active regions are investigated for on-chip light sources. The InAs quantum dot MDLs were grown on V-groove patterned (001) silicon, fully compatible with the prevailing complementary metal oxide-semiconductor technology. By combining the high-quality whispering gallery modes and 3D confinement of injected carriers in quantum dot micro-disk structures, we achieved lasing operation from 10 K up to room temperature under continuous optical pumping. Temperature dependences of the threshold, lasing wavelength, slope efficiency, and mode linewidth are examined. An excellent characteristic temperature T{sub o} of 105 K has been extracted.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Absorptive lasing mode suppression in ZnO nano- and microcavities

We conclusively explain the different lasing mode energies in ZnO nano- and microcavities observed by us and reported in literature. The limited penetration depth of usually used excitation lasers results in an inhomogeneous spatial gain region depending on the structure size and geometry. Hence, weakly or even nonexcited areas remain present after excitation, where modes are instantaneously suppressed by excitonic absorption. We compare the effects for ZnO microwires, nanowires, and tetrapod-like structures at room temperature and demonstrate that the corresponding mode selective effect is most pronounced for whispering-gallery modes in microwires with a hexagonal cross section. Furthermore, the absorptive lasing mode suppression will be demonstrated by correlating the spot size of the excitation laser and the lasing mode characteristic of a single ZnO nanowire.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A simple method for characterizing and engineering thermal relaxation of an optical microcavity

Thermal properties of a photonic resonator are determined not only by intrinsic properties of materials, such as thermo-optic coefficient, but also by the geometry and structure of the resonator. Techniques for characterization and measurement of thermal properties of individual photonic resonator will benefit numerous applications. In this work, we demonstrate a method to optically measure the thermal relaxation time and effective thermal conductance of a whispering gallery mode microcavity using optothermal effect. Two nearby optical modes within the cavity are optically probed, which allows us to quantify the thermal relaxation process of the cavity by analyzing changes in the transmission spectra induced by optothermal effect. We show that the effective thermal conductance can be experimentally deduced from the thermal relaxation measurement, and it can be tailored by changing the geometric parameters of the cavity. The experimental observations are in good agreement with the proposed analytical modeling. This method can be applied to various resonators in different forms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mode coupling in hybrid square-rectangular lasers for single mode operation

Mode coupling between a square microcavity and a Fabry-Pérot (FP) cavity is proposed and demonstrated for realizing single mode lasers. The modulations of the mode Q factor as simulation results are observed and single mode operation is obtained with a side mode suppression ratio of 46 dB and a single mode fiber coupling loss of 3.2 dB for an AlGaInAs/InP hybrid laser as a 300-μm-length and 1.5-μm-wide FP cavity connected to a vertex of a 10-μm-side square microcavity. Furthermore, tunable single mode operation is demonstrated with a continuous wavelength tuning range over 10 nm. The simple hybrid structure may shed light on practical applications of whispering-gallery mode microcavities in large-scale photonic integrated circuits and optical communication and interconnection.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhanced axial confinement in a monolithically integrated self-rolled-up SiN x vertical microring photonic coupler

We report an efficient method to introduce enhanced axial confinement in the self-rolled-up SiN x vertical microtube coupler by depositing a thin layer of high refractive index material strip within the coupling section and effectively forming a vertical microring. Three times wider mode spacing is observed in such a vertical microring coupler monolithically integrated with a silicon nitride ridge waveguide as compared to the one without such axial confinement. More importantly, single mode operation within the telecomm C-band and S-band is achieved. The self-rolled-up microtube has been demonstrated to be a versatile device platform, which has found application in a number of areas including nanophotonics,1–7 microelectronics,8 chemical and biological sensing,9–11 and intelligent synthetic neural circuits.12 Because the microtube is a three dimensional (3D) structure readily fabricated using two dimensional processing technology, it may serve naturally as a component in 3D-integrated devices. We had previously demonstrated a vertical microtube coupler (VμTC) monolithically integrated with planar ridge waveguides in silicon photonic platform to achieve 3D photonic coupling and observed greatly enhanced coupling between the microtube and the underlying ridge waveguide.1,13 A similar result was reported independently by another research group shortly thereafter.2 One limitation of the VμTC used in previous experiments is that it supports many modes within the telecommunication C-band because of poor axial confinement. For example, we found multiple resonant coupling peaks, which is not desirable for wavelength division multiplexing (WDM) switches. In order to increase the mode spacing of this 3D photonic coupler and to achieve single mode operation within the C-band, we propose efficient axial confinement in the microtube to suppress the higher order modes. Axial confinement in self-rolled-up microtubes had been studied both theoretically and experimentally by a couple of research groups.14–17 In all these previous cases, the axial confinement was introduced by a specially designed geometrical shape of a section of the microtube. After being rolled up, the microtube wall will have different thicknesses at different axial locations. The different wall thicknesses result in a slightly varying effective refractive index of the supported whispering gallery modes (WGMs) along the axial direction of the microtube. When a parabolic shape is used, the effective index of the WGM at the center of the parabola will be the highest and decrease adiabatically along both sides. However, the refractive index change due to different wall thicknesses is very small; hence, the axial confinement is rather weak. Here in this paper, we present our experimental endeavor to incorporate a different axial confinement scheme in the monolithically integrated vertical microtube (VμT) to form a vertical microring (VμR) resonator and demonstrate 3 times wider mode spacing than the microtube based vertical photonic coupler and the potential to achieve a higher Q-factor.

36 MATERIALS SCIENCE↗

Off-resonant Raman quantum memory in impurity crystals: signal-to-noise ratio analysis

The possibility of implementing an off-resonant Raman scheme of optical quantum memory on the basis of an ensemble of three-level atoms is investigated under the condition of equal polarisations of resonant transitions forming the Λ-scheme. The developed model is used to analyse the signal-to-noise ratio at the output of an optical quantum memory device in {sup 143}Nd{sup 3+} : Y {sup 7}LiF{sub 4}. It is shown that this ratio can significantly exceed unity for single-photon input pulses. The required values of the parameters can be obtained by using an impurity crystal in the form of a whispering-gallery mode ring resonator. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development and numerical simulation of spherical microresonators based on SiO{sub 2} – GeO{sub 2} germanosilicate glasses for generation of optical frequency combs

We propose and theoretically investigate the possibility of using spherical, whispering gallery mode microresonators based on germanosilicate glasses with different GeO{sub 2} contents for generating optical frequency combs in the dissipative soliton regime under pumping at a wavelength of 1.55 or 2 μm. The dispersion and nonlinearity of microspheres of different radii are calculated and analysed, and their optimal characteristics and the expected parameters of the output radiation are determined. It is shown that the spectral widths of optical frequency combs formed in 0.8SiO{sub 2} – 0.2GeO{sub 2} and GeO{sub 2} glass microspheres pumped at λ = 1.55 and 2 μm can be ∼200 and ∼300 nm, respectively. In these cases, in addition to the dissipative soliton with a duration of ∼100 fs, the generation of dispersive waves is also observed. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Frequency comb generation in WGM microsphere based generators for telecommunication applications

We review the frequency comb generation process, main microresonator parameters such as free spectral range (FSR) and Q-factor, previously used optical frequency comb (OFC) generator parameters and resulting frequency combs, as well as the implementation of OFC for optical data transmission. An optical frequency comb is produced in a setup based on a tapered fibre and a SiO{sub 2} microsphere. The generated frequency comb has a frequency spacing of 2 nm or 257 GHz. During the fabrication of a tapered fibre from SMF28, use is made of the transmission signal to control the taper pulling process. The final measured tapered fibre transmission is ∼96%. A microsphere whispering gallery-mode resonator (WGMR), exhibiting a Q-factor of at least 2 × 10{sup 7}, is fabricated from an optical fibre with a thicker core than SSMF. Moreover, for future experiments, a frequency comb generator based on a free-space setup consisting of lenses, a prism, and a microsphere is developed, and the Q-factor dependence on different distances between the prism and the microsphere is investigated. (optical components of fibre-optic communication lines)

36 MATERIALS SCIENCE↗

Bistable random momentum transfer in a linear on-chip resonator

Optical switches and bifurcation rely on the nonlinear response of materials. Here, we demonstrate linear temporal bifurcation responses in a passive multimode microresonator, with strongly coupled chaotic and whispering gallery modes (WGMs). In microdisks, the chaotic modes exhibit broadband transfer within the deformed cavities, but their transient response is less explored and yields a random output of the analog signal distributed uniformly from “0” to “1.” Here, we build chaotic states by perturbing the multimode microring resonators with densely packed silicon nanocrystals on the waveguide surface. In vivo measurements reveal random and “digitized” output that ONLY populates around 0 and 1 intensity levels. The bus waveguide mode couples first to chaotic modes, then either dissipates or tunnels into stable WGMs. This binary pathway generates high-contrast, digitized outputs. In conclusion, the fully passive device enables real-time conversion of periodic clock signals into binary outputs with contrasts exceeding 12.3 dB, data rates of up to 10 7 · bits per second, and 20 dB dynamic range.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Estimating Code Biases for Criticality Safety Applications with Few Relevant Benchmarks

Criticality safety analyses rely on the availability of relevant benchmark experiments to determine justifiable margins of subcriticality. When a target application lacks neutronically similar benchmark experiments, validation studies must provide justification to the regulator that the impact of modeling and simulation limitations is well understood for the application and often must provide additional subcritical margin to ensure safe operating conditions. This study estimated the computational bias in the critical eigenvalue for several criticality safety applications supported by only a few relevant benchmark experiments. The accuracy of the following three methods for predicting computational biases was evaluated: the Upper Subcritical Limit STATisticS (USLSTATS) trending analysis method; the Whisper nonparametric method; and TSURFER, which is based on the generalized linear least-squares technique. Here, these methods were also applied to estimate computational biases and recommended upper subcriticality limits for several critical experiments with known biases and for several cases from a blind benchmark study. The methods are evaluated based on both the accuracy of their predicted computation bias and upper subcriticality limit estimates, as well as on the consistency of the methods’ estimates, as the model parameters, covariance data libraries, and set of available benchmark data were varied. Data assimilation methods typically have not been used for criticality safety licensing activities, and this study explores a methodology to address concerns regarding the reliability of such methods in criticality safety bias prediction applications.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Comparative Analysis of Standard and Advanced USL Methodologies for Nuclear Criticality Safety

The American National Standards Institute/American Nuclear Society national standards 8.1 and 8.24 provide guidance on the requirements and recommendations for establishing confidence in the results of the computerized models used to support operation with fissionable materials. By design, the guidance is not prescriptive, leaving freedom to the analysts to determine how the various sources of uncertainties are to be statistically aggregated. Due to the involved use of statistics entangled with heuristic recipes, the resulting safety margins are often difficult to interpret. Also, these technical margins are augmented by additional administrative margins, which are required to ensure compliance with safety standards or regulations, eliminating the incentive to understand their differences. With the new resurgent wave of advanced nuclear systems, e.g., advanced reactors, fuel cycles, and fuel concepts, focused on economizing operation, there is a strong need to develop a clear understanding of the uncertainties and their consolidation methods to reduce them in manners that can be scientifically defended. In response, the current studies compare the analyses behind four notable methodologies for upper subcriticality limit estimation that have been documented in the nuclear criticality safety literature: the parametric, nonparametric, Whisper, and TSURFER methodologies. Specifically, the work offers a deep dive into the various assumptions of the noted methodologies, their adequacies, and their limitations to provide guidance on developing confidence for the emergent nuclear systems that are expected to be challenged by the scarcity of experimental data. Here, to limit the scope, the current work focuses on the application of these methodologies to criticality safety experiments, where the goal is to calculate a bias, a bias uncertainty, and a tolerance limit for k eff in support of determining an upper subcriticality limit for nuclear criticality safety.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Design Optimization of a Criticality Experiment for the Molten Chloride Reactor Experiment Facility

Neutronics simulations of Molten Chloride Fast Reactors have quantifiable biases that arise from nuclear data, modeling choices, or numerical methods. The multiphysics nature of molten salt reactors makes it challenging to disentangle neutronics modeling biases from biases originating from other physical phenomena. In comparison to a mock-up reactor, criticality experiments can specifically assess the neutronics modeling bias while limiting multiphysics effects. The criticality experiment must be neutronically representative of the full-scale reactor to be valuable. Here, in this paper, we describe the design of a criticality experiment to validate only the neutronics of TerraPower’s Molten Chloride Reactor Experiment (MCRE) and its criticality safety upset scenarios. The proposed experiment uses different chlorine-containing materials to maximize its similarity to the MCRE. The design process uses a constrained Bayesian optimization algorithm to investigate different objective functions that use covariance information for 35 Cl nuclear data. The experiments could reduce the nuclear data–induced uncertainty in k eff of the MCRE from 2161 to 886 pcm. They would also increase the upper subcritical limit of the MCRE criticality safety upset scenario from 0.94101 to 0.94476 when using the WHISPER analysis framework.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Expanded Intercomparison of Nuclear Data Libraries Using Jupiter and Jupiter High-240 Experiments

There is a limited availability of plutonium experiments with sensitivity to lead in the ICSBEP (International Handbook of Evaluated Criticality Safety Benchmark Experiments) Handbook. The Jupiter and Jupiter High-240 experiments were performed at the National Criticality Experiments Research Center as a collaborative effort between Los Alamos National Laboratory and the Japan Atomic Energy Agency to assess lead void coefficients in a plutonium-lead system containing weapons- and reactor-grade plutonium, respectively. Concurrent with benchmark development, an intercomparison of calculations using different nuclear data libraries has been performed to assess the usability of the experimental data for nuclear data adjustment in a “softer-that-fast” neutron energy spectrum. Eigenvalue calculations using MCNP with the ENDF/B-VIII.0 and TENDL-2021 nuclear data libraries calculate closest to the benchmark values for Jupiter. Calculations using JENDL-5 and ENDF/B-VIII.1 match best with the Jupiter High-240 values. Lead void worth calculations using the various nuclear data libraries are all within 3σ of their respective measured values. Perturbation studies between ENDF/B-VIII.0 and ENDF/B-VIII.1 demonstrate an approximate increase in calculated eigenvalues for the Jupiter series experiments by ~240 pcm for plutonium (mostly 239 Pu) and ~120 pcm for lead accompanied by a decrease contributed by ~113 pcm for copper and ~13 pcm for stainless steel. Nuclear data sensitivities and uncertainties investigated using Whisper show slightly lower sensitivity to scatter than a lead-reflected plutonium sphere but greater sensitivity to neutron capture. The sensitivities between Jupiter and Jupiter High-240 for lead are very similar for both ENDF/B-VIII.0 and ENDF/B-VIII.1 nuclear data. These benchmarks are more sensitive to neutron capture in lead than other plutonium benchmark experiments and would be useful for both lead and 240 Pu validation. In conclusion, with the high degree of compensating effects between copper, lead, and plutonium cross sections, additional isolated Pb-Pu and Cu-Pu benchmarks would be beneficial in improving these nuclear data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Using Machine Learning Methods to Predict Bias in Nuclear Criticality Safety

The manuscript provides a description of the application of machine-learning (ML) tools to the prediction of bias in criticality safety analysis. In particular, a set of over 1000 experiments included in the Whisper package were fed into a variety of ML algorithms (notably Random Forest and AdaBoost) implemented in SciKit-Learn using k-eigenvalue sensitivities (with and without energy dependence) for individual nuclides, and optionally, the simulated k eff as the training features. Ultimately, the ML model was used to predict the bias (k sim - k exp ). The results indicate that use of energy-integrated sensitivity profiles with k sim as training features led to the best predictions as quantified by root-mean square and mean absolute errors. In particular, the best-case estimates came from AdaBoost, with a mean absolute error of 0.00174, which is less than the mean experimental uncertainty of 0.00328 for the experiments included.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗