Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volumetric”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Damage Modeling of Solid Oxide Fuel Cells Accounting for Redox Effects

This work applies a multiscale mechanistic damage model developed for brittle ceramics and implemented in commercial finite element (FE) packages via user subroutines to study progressive damage in solid oxide fuel cells (SOFC) subjected to thermomechanical loading under normal operating and shutdown conditions including redox effects. The damage model captures the micromechanics of stiffness reduction due to material porosity change and microcracking and integrates the as-obtained stiffness reduction law into a continuum damage mechanics (CDM) formulation for the evolution of microcracks up to fracture. The volumetric “swelling” that occurs during redox is treated in constitutive modeling similarly to thermal expansion, but swelling strains are irreversible. Furthermore, this damage model was first validated through predictions of strength and stress-strain response for the SOFC electrode materials. Next, it has been applied to predict the potential for degradation in a generic planar SOFC stack with large active area cells. Multicell stack models were simulated in both co-flow and counter-flow configurations. In addition, a constant temperature redox cycle was also simulated to capture overall cell electrode damage due to volumetric swelling of the nickel (Ni)-based anode in the anode-supported cells.

25 ENERGY STORAGE↗

Promoting CO 2 Release from CO 3 2- -Containing Solvents during Water Electrolysis for Direct Air Capture

The pH swings from water electrolysis are leveraged to condition OH – -based facile CO 2 capture solvents using an electrochemical flow cell for direct air capture (DAC). Besides demonstrating the DAC using a membrane contactor, promoting CO 2 release from a CO 3 2– solution at the anode is specifically studied by adjusting the volumetric flow rate, anode chamber volume, residence time, and K 2 CO 3 concentration. Through case-by-case comparisons coupled with modeled results, increasing current, reducing volumetric flow rate, and/or reducing CO 3 2– concentration are the effective methods to promote CO 2 release from a CO 3 2– -containing solvent, whereas enlarging the anode chamber volume poses a minor effect. Moreover, the discrepancies between the experimental and modeled results may be caused by H + crossover rather than K + transport through the Nafion membrane during water electrolysis based upon the total alkalinity measurements for the K 2 CO 3 solutions gleaned from the anode. Here, it is believed that such results will provide guidance to design and operate an electrochemical flow cell for electrochemistry-assisted DAC and point source CO 2 capture.

20 FOSSIL-FUELED POWER PLANTS↗

Electrochemical Performance of Mixed Redox-Active Organic Molecules in Redox Flow Batteries

Designing electrolytes based on mixture of different organic redox active molecules brings the opportunity of enhancing the volumetric energy density of flow batteries and removes the requirement of high solubility for individual organic species in the mixture. Here, in the present work, we conduct computational and experimental analysis to investigate the electrochemical performance of mixed redox-active organic molecules. A zero-dimensional transient model is employed to investigate the changes in the half-cell potential and the concentrations and partial currents of individual redox reactions in a mixture of organic molecules over time. The model demonstrates the effects of individual properties of species such as kinetic rate constants, mass transfer coefficients, concentration ratios and standard redox potentials and reports the effect of energy-losing homogenous chemical redox reaction on the voltage efficiency and concentration ratios of the mixed species. Pairs of anthraquinone negolyte species were selected for an experimental case study. A mixture of 2,6-N-TSAQ and 2,6-DHAQ showed 40% increase in the volumetric energy density compared to the performance of 2,6-DHAQ alone. Based on the results of the experimental and computational analysis, we propose guidelines for the design of suitable mixed redox-active organic species.

25 ENERGY STORAGE↗

Developments on two lithium vapor-box linear test-stand experiments

The lithium vapor-box divertor is a possible fusion power exhaust solution.It uses condensation pumping to create a gradient of vapor density in a divertor slot; this should allow a stable detachment front without active feedback.As initial explorations of the concept, two test stands which take the form of three connected cylindrical stainless steel boxes are being developed: one without plasma at PPPL, to test models of lithium evaporation and flow; and one for the linear plasma device Magnum-PSI (at DIFFER in Eindhoven, The Netherlands) to test the ability of a lithium vapor cloud to induce volumetric detachment and redistribute the plasma power.The first experiment uses boxes with diameters of 6 cm, joined by apertures with diameters of 2.2 cm. Up to 1 g of Li is placed in one box, which is heated to up to 600 degrees C. The Li evaporates, then flows to and condenses in the two other, cooler boxes over several minutes. The quantity of Li transported is assessed by weighing the boxes before and after the heating cycle, and is compared to the quantity predicted to flow for the box at its measured temperature using a Direct Simulation Monte Carlo code, SPARTA. With good experimental conditions, the two values agree to within 15%.The experiment on Magnum-PSI is in the conceptual design stage.The design is assessed by simulations using the code B2.5-Eunomia.They show that when the hydrogen-ion plasma beam, with n_e = 4e20 per cubic meter, T_e = 1.5 eV, and r = 1 cm, is passed through a 16 cm long, 12 Pa, 625 degree C Li vapor cloud, the plasma heat flux and pressure on the target are significantly reduced compared to the case without Li.With the Li present, the plasma is cooled by excitation of Li neutrals followed by radiation until it volumetrically recombines, lowering the heat flux from 3.7 MW/m^2 to 0.13 MW/m^2, and the pressure is reduced by 93%, largely by collisions of hydrogen ions with neutral Li.

divertor↗

batteryNET v0.0.1

Code to organize, prepare, and segment multi-scan, larger-than-memory, volumetric dataset. Deep learning segmentation uses pytorch-lightning for code organization, logging and metrics, and multi-GPU parallelization of training and prediction. Also uses moani for volumetric data augmentation and model implementation (currently U-Net++). Training can be done slice-by-slice with 2D models trained on 2D patches either aligned with or perpendicular to the electrode plane, or with 3D models on 3D patches. Sparse labels can be used to minimize required hand-labeling -- less than 0.1% of the entire dataset was labeled. Also includes code for data preparation (alignment/cropping/patching).

Ushizima, Daniela↗

Multiscale X-ray phase contrast imaging of human cartilage for investigating osteoarthritis formation

The evolution of cartilage degeneration is still not fully understood, partly due to its thinness, low radio-opacity and therefore lack of adequately resolving imaging techniques. X-ray phase-contrast imaging (X-PCI) offers increased sensitivity with respect to standard radiography and CT allowing an enhanced visibility of adjoining, low density structures with an almost histological image resolution. This study examined the feasibility of X-PCI for high-resolution (sub-) micrometer analysis of different stages in tissue degeneration of human cartilage samples and compare it to histology and transmission electron microscopy. Ten 10%-formalin preserved healthy and moderately degenerated osteochondral samples, post-mortem extracted from human knee joints, were examined using four different X-PCI tomographic set-ups using synchrotron radiation the European Synchrotron Radiation Facility (France) and the Swiss Light Source (Switzerland). Volumetric datasets were acquired with voxel sizes between 0.7 × 0.7 × 0.7 and 0.1 × 0.1 × 0.1 µm 3 . Data were reconstructed by a filtered back-projection algorithm, post-processed by ImageJ, the WEKA machine learning pixel classification tool and VGStudio max. For correlation, osteochondral samples were processed for histology and transmission electron microscopy. X-PCI provides a three-dimensional visualization of healthy and moderately degenerated cartilage samples down to a (sub-)cellular level with good correlation to histologic and transmission electron microscopy images. X-PCI is able to resolve the three layers and the architectural organization of cartilage including changes in chondrocyte cell morphology, chondrocyte subgroup distribution and (re-)organization as well as its subtle matrix structures. X-PCI captures comprehensive cartilage tissue transformation in its environment and might serve as a tissue-preserving, staining-free and volumetric virtual histology tool for examining and chronicling cartilage behavior in basic research/laboratory experiments of cartilage disease evolution.

3D analysis↗

Male Runners With Lower Energy Availability Have Impaired Skeletal Integrity Compared to Nonathletes

Abstract Context Female athletes, particularly runners, with insufficient caloric intake for their energy expenditure [low energy availability (EA) or relative energy deficiency] are at risk for impaired skeletal integrity. Data are lacking in male runners. Objective To determine whether male runners at risk for energy deficit have impaired bone mineral density (BMD), microarchitecture, and estimated strength. Design Cross-sectional. Setting Clinical research center. Participants 39 men (20 runners, 19 controls), ages 16–30 years. Main Outcome Measures Areal BMD (dual-energy x-ray absorptiometry); tibia and radius volumetric BMD and microarchitecture (high-resolution peripheral quantitative computed tomography); failure load (microfinite element analysis); serum testosterone, estradiol, leptin; energy availability. Results Mean age (24.5 ± 3.8 y), lean mass, testosterone, and estradiol levels were similar; body mass index, percent fat mass, leptin, and lumbar spine BMD Z-score (−1.4 ± 0.8 vs −0.8 ± 0.8) lower (P < .05); and calcium intake and running mileage higher (P ≤ .01) in runners vs controls. Runners with EA <median had lower lumbar spine (−1.5 ± 0.7, P = .028), while runners with EA ≥median had higher hip (0.3 ± 0.7 vs −0.4 ± 0.5, P = .002), BMD Z-scores vs controls. After adjusting for calcium intake and running mileage, runners with EA <median had lower mean tibial total and trabecular volumetric BMD, trabecular bone volume fraction, cortical porosity, and apparent modulus vs controls (P < .05). Appendicular lean mass and serum estradiol (R ≥ 0.45, P ≤ .046), but not testosterone, were positively associated with tibial failure load among runners. Conclusions Despite weight-bearing activity, skeletal integrity is impaired in male runners with lower caloric intake relative to exercise energy expenditure, which may increase bone stress injury risk. Lower estradiol and lean mass are associated with lower tibial strength in runners.

Haines, Melanie S. (ORCID:0000000310024754)↗

Mechanisms influencing and prediction of tool influence function spots during hemispherical sub-aperture tool polishing on fused silica

Sub-aperture tool polishing of precision optics requires a detailed understanding of the local material removal [tool influence function (TIF)] at the contact spot between the workpiece and tool to achieve high removal determinism and hence precision of the optic relative to the desired/design surface figure. In this study, the mechanisms influencing and the quantitative prediction of the removal rate and shape of TIF spots during polishing of fused silica glass with cerium oxide slurry using a rotating hemispherical pad-foam tool for a wide variety of process conditions (including tool properties, kinematics, and applied displacements) are investigated. The TIF volumetric removal rate can be estimated utilizing the average relative velocity and contact area using a simple analytical model. In addition, stability of the volumetric removal rate for fixed process conditions is shown to be greatly dependent on the pad preparation and amount of tool use (affecting both pad topography and slurry buildup), whose general behavior shows an increase in removal rate followed by stabilization with polishing time. The determination of the TIF removal shape is more complex. An extended version of the Preston removal model is developed to explain a comprehensive set of measured TIF removal shapes to within ∼ <#comment/> 22 % <#comment/> . This model incorporates a number of phenomena impacting the TIF removal shape including: (a) temporal and spatial dependent relative velocity between the workpiece and tool; (b) an elastic mechanics based, as well as hydrodynamic, pressure distribution; (c) a spatially dependent friction coefficient possibly caused by both reduced slurry replenishment in low velocity regions and pad slurry islands (100 µm scale) and porosity (millimeter scale); and (d) a shear-based removal mechanism on the periphery of the contact spot.

Suratwala, T. (ORCID:0000000190861039)↗

Arrays of glass wedges for multi-dimensional optical diagnostics

There is a common need in the advancement of optical diagnostic techniques to increase the dimensionality of measurements. For example, point measurements could be improved to multi-point, line, planar, volumetric, or time-resolved volumetric measurements. In this work, a unique optical element is presented to enable multi-dimensional measurements, namely, an array of glass wedges. A light source is passed through the wedges, and different portions of the illumination are refracted by different amounts depending on the glass wedge angle. Subsequent optics can be used to focus the light to multiple points, lines, or planes. Basic characterization of a glass wedge array is presented. Additional wedge-array configurations are discussed, including the use of a periodic intensity mask for multi-planar measurements via structured illumination. The utility of this optical element is briefly demonstrated in (a) multi-planar flame particulate measurements, (b) multi-point femtosecond-laser electronic excitation tagging for flow velocimetry, and (c) multi-line nitric oxide molecular tagging velocimetry in a hypersonic shock-tunnel. One significant advantage of this optical component is its compatibility with high-energy laser sources, which may be a limiting factor with other beam-splitting or beam-forming elements such as some diffractive optics. Additionally, an array of glass wedges is simple and easily customizable compared to other methods for forming multiple closely spaced illumination patterns. In conclusion, suggestions for further development and applications are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tidal Turbine Test, Downeast Turbines, July 12, 2021

Downeast Turbines tested a tidal turbine prototype with novel rotor/channel system and lateral effluent discharge apparatus (LEDA), during five days of testing in the flume at Alden Lab. Three days of testing (July 12-14, 2021) focused on turbine power metrics of torque and rpm, which were low, and then two days of follow-up testing (July 27-28, 2021) focused on LEDA performance metrics of pressure differential and rates of volumetric flow, with encouraging results. Next step is to to characterize, and even optimize, configurations of the LEDA, using 3D-CFD as a helpful tool, to refine its shape and explore its limits of performance as a means of effluent discharge that augments performance of an instream turbine. An improved configuration of the LEDA will be re-combined with the rotor/channel system of the turbine prototype, and ultimately, the rotor will be re-sized (enlarged), to better match the LEDA's performance capabilities in drawing through a rate of volumetric flow. This submission is Downeast Turbines' Post Access Report for the test event. It includes the files described here (next below), and several reference links. "Downeast TEAMER-Post-Access-Report...docx" is a document file containing the report. "Appendices A, B, and C" are included in this file, and so are "Figures #1-7." "Appendix D - Test Data Workbooks.zip" is an archive file containing all post access data (raw data tables, calculating tables, and graphs), presented in fourteen Excel workbooks as described in the report. "Appendix E - Post Access Figures.zip" is an archive file containing "Figures #8-52," of the report.

16 TIDAL AND WAVE POWER↗

Soil bulk density and texture data collected during field survey associated with NEON AOP survey, East River, CO 2018

The purpose of soil core sampling was to determine soil bulk density, volumetric water content, and soil texture across the sites that were sampled in association with the National Ecological Observatory Network's Airborne Observation Platform (NEON AOP) in 2018. Soil cores were collected from surface (2.5-7.5 cm) and subsurface (50-55cm) depths at sampling sites across East River, Washington Gulch, Slate River, and Coal Creek watersheds in Gunnison, Colorado during the summer of 2018. Surface samples were weighed for determination of soil water content prior to dry down for bulk density calculations. For all samples, we measured dry weight and weight of < 2mm fraction and conducted soil textural analysis. We provide metadata for the samples, raw data files, python code that was used to calculate bulk density, water content, and texture fraction densities from primary datasets, and a final csv file with the calculated soil bulk density, volumetric water content, and soil texture data. Additional associated site metadata and vegetation fractional cover information can be found in the associated data release.

54 ENVIRONMENTAL SCIENCES↗

Computational Analysis of the Impact of Boundary Conditions on a Particle-Laden Flow: A Case Study in a Pressurized Oxy-Coal Combustor

Designing an effective burner is vital for the development of coal combustion technologies. Because of high pressure, the volumetric fraction of the coal particles in the injected fuel in a pressurized oxy-combustion (POC) burner approaches or even exceeds the limitations allowed by the commercial computational fluid dynamics codes (e.g., Ansys Fluent). Consequently, for such high particle volumetric fractions, the interplay between the particles, the fluid flow, and the burner wall needs to be re-evaluated. The present computational work is a first step in a systematic analysis of the roles of various characteristics involved in the POC process, such as the method of particle release, its location, and the particle size. Specifically, pulverized coal is burned under an elevated pressure of 15 bar in an O 2 /CO 2 environment. A 100 kW, a POC combustor, is modeled with Ansys Fluent using the Reynolds-averaged Navier−Stokes approach. It is revealed that for this pilot-scale, pressurized burner, the gas phase flow velocity in the near-wall region exhibits anomalies. With the major focus on POC, this work aims to eliminate/reduce the impact of high particle loading on the gas-phase flow. To scrutinize the role of particle loading in the near-wall region and eliminate the impact of this velocity on POC downstream, the particle−gas interplay in the boundary layer is investigated by means of the computational simulations incorporating the coupling between the turbulent flow and the particles. It is found that the tuning of the particle release location makes the gas-phase flow velocity in the presence of particles consistent with the pure gas flow velocity profile. The particles size is also found to have a significant impact on the particle trajectory.

CFD↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Independent Review of Paducah Gaseous Diffusion Plant Freon Release Authorized Limits and Evaluation of Corresponding Radiological Doses

The Portsmouth/Paducah Project Office (PPPO) proposes to use the American National Standard Institute (ANSI)/Health Physics Society (HPS) N13.12 (ANSI 2013) volumetric screening levels as Authorized Limits (ALs) for the release of cryofluorane R-114 (Freon) at the Paducah Gaseous Diffusion Plant (PGDP) in Paducah, Kentucky. A review of the proposed ALs document indicated that potential exposure scenarios from the release of Freon are adequately discussed therein. However, questions arose regarding the assumptions made for the ANSI N13.12 clearance values, and whether or not all pathway doses were adequately considered in the Authorized Limits Request. For example, PPPO used the inverse square rule to estimate dose to the truck driver. A more appropriate evaluation would have considered the material as a cylindrical source for this pathway. In addition, the inverse square rule was inadequately applied to the inhalation and ingestion pathways. Furthermore, while the ANSI N13.12 volumetric clearance values are used in the ALs, questions arose concerning whether the values are appropriate for materials of greater than 1 metric ton, and whether or not the ANSI N13.12 standard could be used for liquids that are sent to an incinerator. For these reasons, dose modeling was conducted to demonstrate that using ANSI/HPS N13.12 screening levels as ALs for release of PGDP Freon meets the dose criteria set in U.S. Department of Energy (DOE) Order 458.1. This report provides a bounding dose analysis using scenarios described in PPPO document. Realistic parameters, such as the incinerator characteristics data, are used when available.

61 RADIATION PROTECTION AND DOSIMETRY↗

Counterflow Virtual Impactor (CVI) Inlet Aboard Aircraft (INLETCVI-AIR) Instrument Handbook

The counterflow virtual impactor (CVI) inlet separates out and samples cloud elements via inertial impaction. Warm, dry, particle-free carrier gas of known composition is pumped to the tip of the inlet in the direction opposite of the flow of air. The flow lines of the incoming free stream air are split. Larger droplets and ice crystals suspended in the sample air have enough inertia to penetrate the counterflow and enter the sample flow, while smaller, unactivated particles follow the streamlines of the air flowing around the inlet’s tip (Noone et al. 1988). The instrument is capable of sampling cloud elements as a function of cut size by changing the velocity of counterflow at the probe tip. The CVI cut size is usually defined as a diameter of a smallest particle for which penetration rate is 50%. For the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facilityGulfstream-159 aircraft’s CVI inlet, that value is usually around 13 microns. The dry heated air, normally used as the carrier gas, also serves to evaporate water from the hydrometeor, leaving the residuals to be sampled by in-cabin aerosol instrumentation. The number concentration of the droplet residue in the CVI sample line is usually increased with respect to corresponding cloud element number concentration. The CVI performance as a concentrator is usually described via CVI enhancement factor, which is a conversion factor between ambient volumetric concentration (not adjusted to standard temperature and pressure) and volumetric concentration in the CVI sample line.

54 ENVIRONMENTAL SCIENCES↗

Ultra-high energy density relativistic plasmas from nanostructures: scaling to ultra-high intensities (Final Report)

This project investigated the ultra-high energy density (UHED) regime of matter found in the center of stars, using a compact PW-class laser. These extreme conditions are typically only obtained in the laboratory in the central hot-spot of spherically imploded capsules in inertial confinement fusion experiments driven by the world’s largest lasers. We have shown that near-solid density arrays of aligned nanostructures can be volumetrically heated to multi-keV temperatures by irradiation at relativistic intensity with ultrafast laser pulses of modest energy, opening a path for the generation of UHED plasmas with compact lasers. This new UHED plasma generation approach promises to create an environment with extreme energy densities and degrees of ionization, record conversion of optical laser light into ultrafast x-ray pulses, gigantic magnetic fields and pressures, and directed beams of high energy particles . In this project we achieved record degree of ionization in volumetric heating solid density and near-solid density plasmas. Gold plasmas which spectra is characterized by L shell transition emission from ions with charge up to the Ne-like state, Au+ 72 were generated using ultrafast laser pulses of less than 10 J of energy from a compact laser focused to an intensity of ~ 3x10 21 Wcm -2 . We also conducted measurements to determine the heat penetration depth in Ni nanowire arrays as compared to Ni foil targets by monitoring the line emission of a Co buried tracer underneath a variable amount of Ni. The measurements revealed that the nanowire plasmas are roughly six times larger in depth than the solid density target plasmas. A result of this increased plasma in nanowire arrays is a greatly increased conversion of optical laser light into > 1 KeV x-rays, a record conversion efficiency of 20 %. Critical to the realization of the proposed experiments was the generation of ultrafast laser pulses with ultra-high contrast that can deposit the energy deep into the nanowire arrays before the nanowires explode to create a continuous plasma. Supporting the proposed experiments was the recent demonstration at Colorado State University of a Petawatt-class laser that emits 30 fs pulses at high repetition rates. The experiments combined this unique laser tool with a variety of tailored nanowire arrays fabricated in house and with an extensive suite of diagnostics. The experiments were accompanied by 3-dimensional particle-in-cell simulations and detailed atomic physics simulations with transient kinetics and radiation transport. The proposed research allowed us to continue training Ph.D students and post-docs with broad experience in HEDP Science.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Geodyn Material Library: Pseudocap models for dry porous tocks

This report describes the second edition of the Pseudocap Strength models for porous rocks implemented in GEODYN material library. The first model was developed in 2007 and calibrated for concrete. Then, the model parameters were calibrated based on triaxial tests reported for limestones and sandstones of various porosities. In these models some key parameters were chosen as functions of the reference porosity,Φ. Since then multiple modifications were implemented in the model, therefore, it has been recalibrated for some common porous materials such as limestones, sandstones, alluvium, tuffs and granite. Two types of models are described in this repot. The first type (called Pseudocap Model or PM) is for rocks from a specific location. Parameters were calibrated for several specific geologic materials. The second type (called Generic Pseudocap Model or GPM) is useful for the sites where only basic information (rock type, porosity) is available. Generic models include built-in correlations between porosities and other mechanical properties observed for certain rock types. The models of both types were validated by comparing not only to quasi-static triaxial tests for these materials but also to shock Hugoniot data and spherical explosion data for some materials. All models were derived in the frame of isotropic plasticity. They are designed to be used in explicit finite element/difference codes. Tangent stiffness tensor is not provided but can be calculated numerically for the model to be used in implicit finite element codes. For an isotropic material the stress can be decomposed into volumetric and deviatoric parts. The volumetric part is modeled using an Equation of state (EOS) which calculates the pressure and the bulk sound speed as functions of the internal specific energy and density. Here a simple, Mie-Gruneisen EOS is presented, but tabulated EOS (LEOS) provided by the library can be used as well. The stress is limited by the yield surface which depends on three invariants of the stress tensor and specific internal energy. In addition, to capture the strain-rate dependence a simple multiplier is used for the yield surface which depends on the equivalent plastic strain rate. The failure surface (the ultimate yield, Y f , defined later) is chosen in the Hoek-Brown form, commonly used in rock mechanics. It includes measurable parameters such as Unconfined Compressive Strength (UCS) as well as scale parameters characterizing the quality of the rock such as GSI (Geologic Strength Index). Thus, even though the model is calibrated for small samples it offers a way to extrapolate the strength to the field scale using geological characterization of the rock mass. The model captures effects of brittle-ductile transition in rocks by introducing a cap multiplier to the yield function. The rate of dilatancy (bulking) is proportional to the slope of the yield surface affected by the cap. Therefore, it takes place only at low confinements when the pressure is less than the brittle-ductile transition pressure, P BD . On the contrary, the porous compaction takes place at pressures higher than P BD . The cap moves as the porosity is compacted or new porosity is generated due to dilatancy. The porous compaction is modeled using an evolution equation which includes deviatoric stress so that the onset of compaction corresponds to the cap surface. The model captures effects of shear-enhanced compaction which is an important for porous rocks. Section 2 describes the modeling framework and Section 3 presents the model calibration procedure. Section 4 compares experimental data for various rocks versus model predictions. The model parameters used for this comparison are given in Appendix. The files with material constants are available with the latest GEODYN material library distribution.

58 GEOSCIENCES↗

The Challenge Ahead: A Critical Perspective on Meeting U.S. Growth Targets for Sustainable Aviation Fuel

With demand for jet fuel expected to more than double by 2050 and triple by 2070, continued and accelerated efforts to decarbonize the global aviation sector are needed to curtail rising emissions and avert the worst outcomes of climate change. In response to this call-to-action, the United States has unveiled the Sustainable Aviation Fuel (SAF) Grand Challenge, which seeks to expedite the development of alternative fuel pathways that offer a minimum of a 50% reduction in life cycle greenhouse gas emissions compared to conventional jet fuel. However, there is growing concern on whether sufficient biomass will be readily available to satisfy the projected sharp rise in demand for SAF. Carbon dioxide point-source emissions combined with rising supply from direct air capture efforts have the potential to complement and offset any supply gaps for biomass-derived SAF and other use cases. Independent of the chosen feedstock and conversion technology, numerous challenges persist across SAF production in seeking to drive down fuel cost and carbon intensity. To hit the 2030 target of 3 billion gal/yr, this means about a 100% compound annual growth rate in volumetric SAF production (about 130 times scale-up) will need to be realized. To achieve the stretch goal of 35 billion gallons of SAF per year by 2050, volumetric production must increase by a factor of 12 from the 3-billion-gal/year 2030 target of SAF Grand Challenge. The comparatively longer runway for 2050 combined with significant production volume growth suggests a more inclusive "all-hands-on-deck"-style approach will likely play a role. A key component in success lies in the coordinated research, development, demonstration, and deployment efforts by multiple federal agencies and industry partnerships.

09 BIOMASS FUELS↗