Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VOLUME”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

SU-E-T-429: Uncertainties of Cell Surviving Fractions Derived From Tumor-Volume Variation Curves

Purpose: To evaluate uncertainties of cell surviving fraction reconstructed from tumor-volume variation curves during radiation therapy using sensitivity analysis based on linear perturbation theory. Methods: The time dependent tumor-volume functions V(t) have been calculated using a twolevel cell population model which is based on the separation of entire tumor cell population in two subpopulations: oxygenated viable and lethally damaged cells. The sensitivity function is defined as S(t)=[δV(t)/V(t)]/[δx/x] where δV(t)/V(t) is the time dependent relative variation of the volume V(t) and δx/x is the relative variation of the radiobiological parameter x. The sensitivity analysis was performed using direct perturbation method where the radiobiological parameter x was changed by a certain error and the tumor-volume was recalculated to evaluate the corresponding tumor-volume variation. Tumor volume variation curves and sensitivity functions have been computed for different values of cell surviving fractions from the practically important interval S{sub 2}=0.1-0.7 using the two-level cell population model. Results: The sensitivity functions of tumor-volume to cell surviving fractions achieved a relatively large value of 2.7 for S{sub 2}=0.7 and then approached zero as S{sub 2} is approaching zero Assuming a systematic error of 3-4% we obtain that the relative error in S{sub 2} is less that 20% in the range S2=0.4-0.7. This Resultis important because the large values of S{sub 2} are associated with poor treatment outcome should be measured with relatively small uncertainties. For the very small values of S2<0.3, the relative error can be larger than 20%; however, the absolute error does not increase significantly. Conclusion: Tumor-volume curves measured during radiotherapy can be used for evaluation of cell surviving fractions usually observed in radiation therapy with conventional fractionation.

60 APPLIED LIFE SCIENCES↗

SU-E-T-525: Dose Volume Histograms (DVH) Analysis and Comparison with ICRU Point Doses in MRI Guided HDR Brachytherapy for Cervical Cancer

Purpose: Brachytherapy plays a crucial role in management of cervix cancer. MRI compatible applicators have made it possible to accurately delineate gross-target-volume(GTV) and organs-at-risk(OAR) volumes, as well as directly plan, optimize and adapt dose-distribution for each insertion. We sought to compare DVH of tumor-coverage and OARs to traditional Point-A, ICRU-38 bladder and rectum point-doses for four different planning-techniques. Methods: MRI based 3D-planning was performed on Nucletron-Oncentra-TPS for 3 selected patients with varying tumor-sizes and anatomy. GTV,high-risk-clinical-target-volume(HR-CTV), intermediate-risk-clinical-target-volume(IR-CTV) and OARs: rectum, bladder, sigmoid-colon, vaginal-mucosa were delineated. Three conventionally used techniques: mg-Radium-equivalent(RaEq),equal-dwell-weights(EDW), Medical-College-of-Wisconsin proposed points-optimization (MCWO) and a manual-graphical-optimization(MGO) volume-coverage based technique were applied for each patient. Prescription was 6Gy delivered to point-A in Conventional techniques (RaEq, EDW, MCWO). For MGO, goal was to achieve 90%-coverage (D90) to HR-CTV with prescription-dose. ICRU point doses for rectum and bladder, point-A doses, DVH-doses for HR-CTV-D90,0.1cc-volume(D0.1),1ccvolume( D1),2cc-volume(D2) were collected for all plans and analyzed . Results: Mean D90 for HR-CTV normalized to MGO were 0.89,0.84,0.9,1.0 for EDW, RaEq, MCWO, MGO respectively. Mean point-A doses were 21.7% higher for MGO. Conventional techniques with Point-A prescriptions under covered HR-CTV-D90 by average of 12% as compared to MGO. Rectum, bladder and sigmoid doses were highest in MGO-plans for ICRU points as well as D0.1,D1 and D2 doses. Among conventional-techniques, rectum and bladder ICRU and DVH doses(0.1,1,2cc) were not significantly different (within 7%).Rectum D0.1 provided good estimation of ICRU-rectum-point doses (within 3.9%),rectum D0.1 were higher from 0.8 to 3.9% while bladder D0.1 overestimated the bladder ICRU point dose up to 43% for conventional-techniques.Bladder-D2 provided a good estimation of ICRU bladder point-doses(within 3.6%) for conventional-techniques. This correlation is not observed for MGO plans perhaps due to steering of isodose line, leading to unpredictable dwell-weighting. Conclusion: MRI based HDR-planning provides accurate delineation of tumor volumes and normal structures, and optimized tumor-coverage can be achieved with acceptable normal-tissue doses. This study showed that for conventional techniques D0.1 rectum dose and D2 bladder dose are good representation of ICRU-reference-point doses.

60 APPLIED LIFE SCIENCES↗

SU-E-J-79: Evaluation of Prostate Volume Changes During Radiotherapy Using Implanted Markers and On-Board Imaging

Purpose: To evaluate prostate volume changes during radiation therapy using implanted gold markers and on-board imaging. Methods: Twenty-five patients were included who underwent an implantation of three gold markers. Cartesian coordinates of markers were assessed in kV-images. The coordinates of centers of two markers were measured on kV-images from the center of the marker at the apex which was reference. The distances between the markers were extrapolated from the coordinates using the Euclid formula. The radius of the sphere through markers was calculated using sinus theorem. The prostate volume for the first and last fraction was substituted with a sphere model and was calculated for each patient. The t-test was used for analysis. Results: The mean prostate volume for first and last fraction was 24.65 and 20.87 cc, respectively (p≤0.05). The prostate volume was smaller for 23 patients, whereas there was an expansion for 2 patients. Fifteen patients had androgen deprivation during radiotherapy (H group) and ten did not (NH group). The mean prostate volume for the first and last fraction for the NH group was 30.73 cc and 24.89 cc and for the H group 20.84 cc and 18.19 cc, respectively. There was a 15.8% volume change during treatment for the NH group and 12.2% for the H group, but the difference was not statistically significant. The radius difference of the theoretical sphere for the first and last fraction was 0.98 mm (range, 0.09–2.95 mm) and remained below 2 mm in 88% of measurements. Conclusion: There was a significant volume change during prostate radiotherapy. The difference between H group and NH group was not significant. The radius changes did not exceed 3 mm and it was below adaptive treatment requirements. Our results indicate that prostate volume changes during treatment should be taken into account during contouring and treatment planning.

60 APPLIED LIFE SCIENCES↗

SU-E-J-266: Cone Beam Computed Tomography (CBCT) Inter-Scan and Inter-Observer Tumor Volume Variability Assessment in Patients Treated with Stereotactic Body Radiation Therapy (SBRT) for Early Stage Non-Small Cell Lung Cancer (NSCLC)

Purpose: Quantification of volume changes on CBCT during SBRT for NSCLC may provide a useful radiological marker for radiation response and adaptive treatment planning, but the reproducibility of CBCT volume delineation is a concern. This study is to quantify inter-scan/inter-observer variability in tumor volume delineation on CBCT. Methods: Twenty earlystage (stage I and II) NSCLC patients were included in this analysis. All patients were treated with SBRT with a median dose of 54 Gy in 3 to 5 fractions. Two physicians independently manually contoured the primary gross tumor volume on CBCTs taken immediately before SBRT treatment (Pre) and after the same SBRT treatment (Post). Absolute volume differences (AVD) were calculated between the Pre and Post CBCTs for a given treatment to quantify inter-scan variability, and then between the two observers for a given CBCT to quantify inter-observer variability. AVD was also normalized with respect to average volume to obtain relative volume differences (RVD). Bland-Altman approach was used to evaluate variability. All statistics were calculated with SAS version 9.4. Results: The 95% limit of agreement (mean ± 2SD) on AVD and RVD measurements between Pre and Post scans were −0.32cc to 0.32cc and −0.5% to 0.5% versus −1.9 cc to 1.8 cc and −15.9% to 15.3% for the two observers respectively. The 95% limit of agreement of AVD and RVD between the two observers were −3.3 cc to 2.3 cc and −42.4% to 28.2% respectively. The greatest variability in inter-scan RVD was observed with very small tumors (< 5 cc). Conclusion: Inter-scan variability in RVD is greatest with small tumors. Inter-observer variability was larger than inter-scan variability. The 95% limit of agreement for inter-observer and inter-scan variability (∼15–30%) helps define a threshold for clinically meaningful change in tumor volume to assess SBRT response, with larger thresholds needed for very small tumors. Part of the work was funded by a Kaye award; Disclosure/Conflict of interest: Raymond H. Mak: Stock ownership: Celgene, Inc. Consulting: Boehringer-Ingelheim, Inc.

60 APPLIED LIFE SCIENCES↗

SU-F-T-113: Inherent Functional Dependence of Spinal Cord Doses of Variable Irradiated Volumes in Spine SBRT

Purpose: Spinal cord tolerance for SBRT has been recommended for the maximum point dose level or at irradiated volumes such as 0.35 mL or 10% of contoured volumes. In this study, we investigated an inherent functional relationship that associates these dose surrogates for irradiated spinal cord volumes of up to 3.0 mL. Methods: A hidden variable termed as Effective Dose Radius (EDR) was formulated based on a dose fall-off model to correlate dose at irradiated spinal cord volumes ranging from 0 mL (point maximum) to 3.0 mL. A cohort of 15 spine SBRT cases was randomly selected to derive an EDR-parameterized formula. The mean prescription dose for the studied cases was 21.0±8.0 Gy (range, 10–40Gy) delivered in 3±1 fractions with target volumes of 39.1 ± 70.6 mL. Linear regression and variance analysis were performed for the fitting parameters of variable EDR values. Results: No direct correlation was found between the dose at maximum point and doses at variable spinal cord volumes. For example, Pearson R{sup 2} = 0.643 and R{sup 2}= 0.491 were obtained when correlating the point maximum dose with the spinal cord dose at 1 mL and 3 mL, respectively. However, near perfect correlation (R{sup 2} ≥0.99) was obtained when corresponding parameterized EDRs. Specifically, Pearson R{sup 2}= 0.996 and R{sup 2} = 0.990 were obtained when correlating EDR (maximum point dose) with EDR (dose at 1 mL) and EDR(dose at 3 mL), respectively. As a result, high confidence level look-up tables were established to correlate spinal cord doses at the maximum point to any finite irradiated volumes. Conclusion: An inherent functional relationship was demonstrated for spine SBRT. Such a relationship unifies dose surrogates at variable cord volumes and proves that a single dose surrogate (e.g. point maximum dose) is mathematically sufficient in constraining the overall spinal cord dose tolerance for SBRT.

60 APPLIED LIFE SCIENCES↗

Solubility and volume swell of fuel system elastomers with ketone blends of E10 gasoline and blendstock for oxygenate blending (BOB)

The compatibility of key infrastructure elastomers with five ketone molecules was assessed via solubility studies and volume swell measurements. The elastomer materials included two fluorocarbons, six acrylonitrile butadiene rubbers (NBRs), and one each of fluorosilicone, neoprene, polyurethane, styrene butadiene rubber (SBR), and silicone. The ketone molecules included acetone, 2-butanone, 2-pentanone, 2-nonanone, and cyclopentanone. The ketones were added to gasoline containing 10% ethanol (E10) and a blendstock for oxygenate blending (BOB) in levels ranging from 0% to 30% by volume. The elastomers were exposed for 4 weeks in each test fluid. The solubility was modeled using Hansen solubility parameters and the volume change was determined for each material and test fuel. In general, the volume swell increased with ketone content and corresponded well to the predicted solubilities. In most cases, the highest level of swelling occurred with added cyclopentanone and acetone, while 2-nonanone produced the lowest levels of volume expansion. The chain length of the straight ketones was found to affect the volume swell behavior as volume expansion decreased with increasing chain length. This behavior is attributed to the reduction in polarity and hydrogen bonding with chain length. Neoprene, SBR, and silicone exhibited poor compatibility with the ketone molecules at all blend levels. Fluorocarbon and fluorosilicone also showed poor compatibility but may be suitable for use as static seals in very low blend levels with 2-nonanone. The results were more mixed for polyurethane and the NBRs. In general, better compatibility (low volume swell) was observed for mixtures containing BOB than for E10. This is due to the lower polarity and hydrogen bonding of the BOB.

10 SYNTHETIC FUELS↗

Automatic Volume Balancing for Online Refueling in Molten Salt Reactor Simulations with SCALE

This work introduces recently implemented capabilities in the SCALE code system’s TRITON reactor physics sequence that improve molten salt reactor (MSR) modeling: (1) a volume balancing option, which automatically balances the volumes of the fed material with a corresponding material removal to maintain fixed mixture volumes in the neutron transport model and accurate densities, and (2) continuous feed from mixtures, which enables users to define material feed streams directly from salt mixture definitions rather than individual nuclides. The new capabilities were demonstrated via SCALE/TRITON simulations of two representative MSR concepts. Simulations of the 180 MWth molten chloride fast reactor—a system with a fixed fuel salt volume in the reactor core—applied continuous refueling with fresh fuel salt. The results confirm approximately constant reactivity when the new volume balancing capability is used. Additionally, excellent agreement with a manual feed-and-drain method for volume balancing further verified the new implementation. Simulations of the 400 MWth EIRENE reactor, an integral MSR in which the salt volume may grow over time within the reactor core, demonstrated the capability to represent growing salt volume within the TRITON depletion calculation. Compared with reference solutions, the results show consistent trends in reactivity and isotopic evolution, confirming that these new user-friendly capabilities provide accurate, physically consistent approaches for modeling MSRs in SCALE.

Elzohery, Rabab [ORNL] (ORCID:0000000160043633)↗

Total-dose radiation effects data for semiconductor devices, volume 3

Volume 3 of this three-volume set provides a detailed analysis of the data in Volumes 1 and 2, most of which was generated for the Galileo Orbiter Program in support of NASA space programs. Volume 1 includes total ionizing dose radiation test data on diodes, bipolar transistors, field effect transistors, and miscellaneous discrete solid-state devices. Volume 2 includes similar data on integrated circuits and a few large-scale integrated circuits. The data of Volumes 1 and 2 are combined in graphic format in Volume 3 to provide a comparison of radiation sensitivities of devices of a given type and different manufacturer, a comparison of multiple tests for a single data code, a comparison of multiple tests for a single lot, and a comparison of radiation sensitivities vs time (date codes). All data were generated using a steady-state 2.5-MeV electron source (Dynamitron) or a Cobalt-60 gamma ray source. The data that compose Volume 3 represent 26 different device types, 224 tests, and a total of 1040 devices. A comparison of the effects of steady-state electrons and Cobat-60 gamma rays is also presented.

Price, W. E.↗

MOD-5A wind turbine generator program design report: Volume 1: Executive Summary

The design, development and analysis of the 7.3 MW MOD-5A wind turbine generator covering work performed between July 1980 and June 1984 is discussed. The report is divided into four volumes: Volume 1 summarizes the entire MOD-5A program, Volume 2 discusses the conceptual and preliminary design phases, Volume 3 describes the final design of the MOD-5A, and Volume 4 contains the drawings and specifications developed for the final design. Volume 1, the Executive Summary, summarizes all phases of the MOD-5A program. The performance and cost of energy generated by the MOD-5A are presented. Each subsystem - the rotor, drivetrain, nacelle, tower and foundation, power generation, and control and instrumentation subsystems - is described briefly. The early phases of the MOD-5A program, during which the design was analyzed and optimized, and new technologies and materials were developed, are discussed. Manufacturing, quality assurance, and safety plans are presented. The volume concludes with an index of volumes 2 and 3.

Source record↗

Data space volumes and classification optimization of SPOT and Landsat TM data

In order to compare the data space volume of SPOT XS and Landsat TM images, three data sets, i.e., a wetlands/agricultural data set, an agricultural data set, and a forest data set, are examined. The comparisons are made for the same geographic area. The data space volumes for Landsat TM (2, 3, and 4) are found to be 70 to 100 percent larger than the volumes for the SPOT XS images. It is suggested that the additional midinfrared bands contribute to the difference in data space volumes between Landsat TM and SPOT XS. The data space volumes for Landsat TM bands 3, 4, and 5 are more than an order of magnitude greater than the volumes for the three band SPOT XS data sets. The volumes of the six-band Landsat TM images are four orders of magnitude greater than the SPOT XS. The analysis of the data space volumes is used to optimize the computation time and minimize the storage requirements of a maximum-likelihood classification based on a look-up table.

Ahearn, Sean C.↗

Clinical Aspects of the Control of Plasma Volume at Microgravity and During Return to One Gravity

Plasma volume is reduced by 10%-20% within 24 to 48 h of exposure to simulated or actual microgravity. The clinical importance of microgravity-induced hypovolemia is manifested by its relationship with orthostatic intolerance and reduced VO2max after return to one gravity (1G). Since there is no evidence to suggest plasma volume reduction during microgravity is associated with thirst or renal dysfunctions, a diuresis induced by an immediate blood volume shift to the central circulation appears responsible for microgravity-induced hypovolemia. Since most astronauts choose to restrict their fluid intake before a space mission, absence of increased urine output during actual spaceflight may be explained by low central venous pressure (CVP) which accompanies dehydration. Compelling evidence suggests that prolonged reduction in CVP during exposure to microgravity reflects a 'resetting' to a lower operating point which acts to limit plasma volume expansion during attempts to increase fluid intake. In groudbase and spaceflight experiments, successful restoration and maintenance of plasma volume prior to returning to an upright posture may depend upon development of treatments that can return CVP to its baseline 10 operating point. Fluid-loading and LBNP have not proved completely effective in restoring plasma volume, suggesting that they may not provide the stimulus to elevate the CVP operating point. On the other, exercise, which can chronically increase CVP, has been effective in expanding plasma volume when combined with adequate dietary intake of fluid and electrolytes. The success of designing experiments to understand the physiological mechanisms of and development of effective countermeasures for the control of plasma volume in microgravity and during return to one gravity will depend upon testing that can be conducted under standardized controlled baseline condi

Convertino, Victor A.↗

Preventing Molecular and Particulate Infiltration in a Confined Volume

Contaminants from an instrument's self-generated sources or from sources external to the instrument may degrade its critical surfaces and/or create an environment which limits the instrument's intended performance. Analyses have been carried out on a method to investigate the required purging flow of clean, dry gas to prevent the ingestion of external contaminants into the instrument container volume. The pressure to be maintained and the required flow are examined in terms of their effectiveness in preventing gaseous and particulate contaminant ingestion and abatement of self-generated contaminants in the volume. The required venting area or the existing volume venting area is correlated to the volume to be purged, the allowable pressure differential across the volume, the external contaminant partial pressure, and the sizes of the ambient particulates. The diffusion of external water vapor into the volume while it was being purged was experimentally obtained in terms of an infiltration time constant. That data and the acceptable fraction of the outside pressure into the volume indicate the required flow of purge gas expressed in terms of volume change per unit time. The exclusion of particulates is based on the incoming velocity of the particles and the exit flow speed and density of the purge gas. The purging flow pressures needed to maintain the required flows through the vent passages are indicated. The purge gas must prevent or limit the entrance of the external contaminants to the critical locations of the instrument. It should also prevent self- contamination from surfaces, reduce material outgassing, and sweep out the outgassed products. Systems and facilities that can benefit from purging may be optical equipment, clinical facilities, manufacturing facilities, clean rooms, and other systems requiring clean environments.

Scialdone, John J.↗

Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4, Volume IV: Inherent Optical Properties: Instruments, Characterizations, Field Measurements and Data Analysis Protocols

This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparision and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background, and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 is entirely superseded by the six volumes of Revision 4 listed above.

Mueller, J. L.↗

Changes in peak oxygen uptake and plasma volume in fit and unfit subjects following exposure to a simulation of microgravity

To test the hypothesis that the magnitude of reduction in plasma volume and work capacity following exposure to simulated microgravity is dependent on the initial level of aerobic fitness, peak oxygen uptake (VO2peak) was measured in a group of physically fit subjects and compared with VO2peak in a group of relatively unfit subjects before and after 10 days of continuous 6 degrees head-down tilt (HDT). Ten fit subjects (40 +/- 2 year) with mean +/- SE VO2peak = 48.9 +/- 1.7 mL kg-1 min-1 were matched for age, height, and lean body weight with 10 unfit subjects (VO2peak = 37.7 +/- 1.6 mL kg-1 min-1). Before and after HDT, plasma, blood, and red cell volumes and body composition were measured and all subjects underwent a graded supine cycle ergometer test to determine VO2peak period needed. Reduced VO2peak in fit subjects (-16.2%) was greater than that of unfit subjects (-6.1%). Similarly, reductions in plasma (-18.3%) and blood volumes (-16.0%) in fit subjects were larger than those of unfit subjects (blood volume = -5.6%; plasma volume = -6.6%). Reduced plasma volume was associated with greater negative body fluid balance during the initial 24 h of HDT in the fit group (912 +/- 154 mL) compared with unfit subjects (453 +/- 200 mL). The percentage change for VO2peak correlated with percentage change in plasma volume (r = +0.79). Following exposure to simulated microgravity, fit subjects demonstrated larger reductions in VO2peak than unfit subjects which was associated with larger reductions in plasma and blood volume. These data suggest that the magnitude of physical deconditioning induced by exposure to microgravity without intervention of countermeasures was influenced by the initial fitness of the subjects.

Non-NASA Center↗

Space Biology and Medicine: Space and Its Exploration - Volume I

Perhaps one of the greatest gifts that has been given to the people of the world in the last few hundred years has been an emerging sense of the place of our planet and its inhabitants within the context of the vast universe. Our knowledge of the rest of the universe has not come quickly, nor was the process of attaining it only recently begun; however, the unprecedented acceleration of that process has benefitted from a fundamental new aspect of our species that has only manifested itself in the last 30 years or so, the ability to travel in space. Before the space age, the Universe was studied only through observations from the Earth. All that has changed with the beginning of the space age. Machines built by humans have flown to all but one of the nine planets that revolve around our Sun, have ventured billions of miles from the Earth and looked back, and have landed on three other worlds. Spacecraft in orbit around the Earth have viewed the sky at a vast number of electromagnetic wavelengths, detecting the shape of the galaxy and the universe, and even measuring the remnants of the universe's beginning. Human explorers have ventured forth, first for short stays in orbit, then, later, walking upon the Moon and living for long periods in space. As they did so, billions of people on the Earth came to view the Earth in a fundamentally different way, not just as the familiar day to- day backdrop for their lives, but as a small oasis suspended in the night sky above an alien landscape. It is this new view of the Earth that is the true gift of space exploration. Space exploration has at once given us a new perspective on the value of our world, and a new perspective from which to understand how it operates. It has shown us that the Earth is by far the most precious place in the solar system in terms of supporting human life, while revealing that other destinations may still be compelling. The exploration of space has at once become a challenge for humanity to overcome and a path to our common future. But for humanity to embark on this path, we need to understand ourselves in a new environment. As such, an understanding of the biological consequences of and opportunities in space flight is essential. In this, the first volume of a joint U.S./Russian series on space biology and medicine, we describe the current status of our understanding of space and present general information that will prove useful when reading subsequent volumes. Since we are witnesses to the beginning of a new era of interplanetary travel, a significant portion of the first volume will concentrate on the physical and ecological conditions that exist in near and outer space, as well as heavenly bodies from the smallest ones to the giant planets and stars. While space exploration is a comparatively recent endeavor, its foundations were laid much more than 30 years ago, and its history has been an eventful one. In the first part of this volume, Rauschenbach, Sokolskiy, and Gurjian address the "Historical Aspects of Space Exploration" from its beginnings to a present-day view of the events of the space age. The nature of space itself and its features is the focus of the second section of the volume. In the first chapter of the part, "Stars and Interstellar Space," the origin and evolution of stars, and the nature of the portions of space most distant from Earth are described by Galeev and Marochnik. In Chapter 2, Pisarenko, Logachev, and Kurt in "The Sun and Interplanetary Space" bring us to the vicinity of our own solar system and provide a description and discussion of the nearest star and its influence on the space environment that our Earth and the other planets inhabit. In our solar system there are many fascinating objects, remnants of the formation of a rather ordinary star in a rather obscure portion of the galaxy. Historical accident has caused us to be much more curious (and knowledgeable) about "The Inner Planets of the Solar System" than about any of these other objects. In Chapter 3, Marov describes the planets Mercury, Venus, Earth, and Mars, their history and origin, and their environmental conditions, and in Chapter 4 Owen provides similar information about Jupiter, Saturn, Uranus, Neptune, and Pluto, "The Outer Planets of the Solar System." Morrison provides a thorough discussion of "Asteroids, Comets, and Other Small Bodies" in Chapter 5. The understanding of these relics of the formation of the solar system may form the center of our ability to understand the origin of solar systems in general, and of the critical role that the beginning of the solar system had on the prospects for the origin of life and its continued survival and evolution in the face of their recurrent impacts on Earth. In Chapter 6, the first chapter of the third part, Rummel describes the area of "Exobiology," the study of the origin, evolution, and distribution of life in the context of the origin and evolution of the universe. The same processes that have given rise to life on Earth may have given rise to life elsewhere. In Chapter 7, the "Earth and the Biosphere," the nature and function of the Earth are discussed as a specific instance of planetary and biological evolution. The effects of biological processes on the Earth under the influence of human activities are also addressed by Moore and Bartlett in Chapter 7. The final chapter in this section concerns the prospects that life in the universe may be widespread; "SETI," the Search for Extraterrestrial Intelligence, by Billingham and Tarter, presents the arguments for conducting a search for evidence of life elsewhere in the galaxy, and describes the various methods proposed for conducting such a search. While SETI has a distinctly exploration al character, more direct means are available for exploring the solar system around us. The fourth part of the volume addresses this subject of space exploration. Considering the prospects for research on space biology and medicine, the means of providing "Access to Space" are described by Feoktistov and Briggs in Chapter 9. This chapter addresses carriers and launch systems, the unmanned and manned spacecraft that they loft into space, and the task of mission operations by which these precious vessels are monitored, navigated, and controlled. Despite the successes of the past and the capabilities of the present, it is clear that the study of space biology and medicine will be even more rewarding in the future than it has been to date. The work of the next few years that will be undertaken by the U.S. and Russia, both independently and jointly, will focus first on enabling greater capabilities in the exploration of space, and then on using the unique characteristics of the space environment to provide insight and greater understanding into biological systems, their behavior, development, and origin. The chapters of the first volume were written by leaders in their fields from the U.S. and Russia. The material presented summarizes our current understanding of space and its exploration. We understand that the first volume will be of interest not only to medical personnel and biologists, but also to general readers who want information about space beyond their own particular fields of expertise.

Nicogossian, Arnauld E.↗

Individual Global Navigation Satellite Systems in the Space Service Volume

Besides providing position, navigation, and timing (PNT) to terrestrial users, GPS is currently used to provide for precision orbit determination, precise time synchronization, real-time spacecraft navigation, and three-axis control of Earth orbiting satellites. With additional Global Navigation Satellite Systems (GNSS) coming into service (GLONASS, Beidou, and Galileo), it will be possible to provide these services by using other GNSS constellations. The paper, "GPS in the Space Service Volume," presented at the ION GNSS 19th International Technical Meeting in 2006 (Ref. 1), defined the Space Service Volume, and analyzed the performance of GPS out to 70,000 km. This paper will report a similar analysis of the performance of each of the additional GNSS and compare them with GPS alone. The Space Service Volume, defined as the volume between 3,000 km altitude and geosynchronous altitude, as compared with the Terrestrial Service Volume between the surface and 3,000 km. In the Terrestrial Service Volume, GNSS performance will be similar to performance on the Earth's surface. The GPS system has established signal requirements for the Space Service Volume. A separate paper presented at the conference covers the use of multiple GNSS in the Space Service Volume.

Beidou↗

MPCV Exercise Operational Volume Analysis

In order to minimize the loss of bone and muscle mass during spaceflight, the Multi-purpose Crew Vehicle (MPCV) will include an exercise device and enough free space within the cabin for astronauts to use the device effectively. The NASA Digital Astronaut Project (DAP) has been tasked with using computational modeling to aid in determining whether or not the available operational volume is sufficient for in-flight exercise.Motion capture data was acquired using a 12-camera Smart DX system (BTS Bioengineering, Brooklyn, NY), while exercisers performed 9 resistive exercises without volume restrictions in a 1g environment. Data were collected from two male subjects, one being in the 99th percentile of height and the other in the 50th percentile of height, using between 25 and 60 motion capture markers. Motion capture data was also recorded as a third subject, also near the 50th percentile in height, performed aerobic rowing during a parabolic flight. A motion capture system and algorithms developed previously and presented at last years HRP-IWS were utilized to collect and process the data from the parabolic flight [1]. These motions were applied to a scaled version of a biomechanical model within the biomechanical modeling software OpenSim [2], and the volume sweeps of the motions were visually assessed against an imported CAD model of the operational volume. Further numerical analysis was performed using Matlab (Mathworks, Natick, MA) and the OpenSim API. This analysis determined the location of every marker in space over the duration of the exercise motion, and the distance of each marker to the nearest surface of the volume. Containment of the exercise motions within the operational volume was determined on a per-exercise and per-subject basis. The orientation of the exerciser and the angle of the footplate were two important factors upon which containment was dependent. Regions where the exercise motion exceeds the bounds of the operational volume have been identified by determining which markers from the motion capture exceed the operational volume and by how much. A credibility assessment of this analysis was performed in accordance with NASA-STD-7009 prior to delivery to the MPCV program.

mathematical models↗

Network Scale Ubiquitous Volume Estimation Using Tree-Based Ensemble Learning Methods

Currently real-time, ubiquitous volume data for roadway networks remains the key missing dimension in traffic operations. Most volume data are average annual daily traffic (AADT) measures derived from the Highway Performance Monitoring System (HPMS). Although methods to factor the AADT to hourly averages for typical day of week exist, actual volume data is limited to a sparse collection of locations in which volumes are continuously recorded. This paper explores the use of state-of-art machine learning techniques to estimate accurate real-time volume measures that span the highway network providing ubiquitous coverage in space, and point-in-time measures for a specific date and time. Three tree-based ensemble learning models, random forest (RF), gradient boost machine (GBM), and extreme gradient boost (XGBoost), were tested for volume estimation by learning from combined dataset of commercial probe data provided by TomTom, the FHWA's Travel Monitoring Analysis System (TMAS) data, and other infrastructure attributes such as number of lanes, speed limit, and weather. The methods were tested on major corridors and freeways in the metropolitan area of Denver. All three machine learning methods were able to provide hourly volume estimates 24 hours a day, 7 days a week, and 365 days a year with around 18% mean absolute error to true volume and about 5% of error with respect to roadway capacity. The low error measures allow the potential application by transportation agencies.

33 ADVANCED PROPULSION SYSTEMS↗