Clean Indoor Air and Lower Environmental Impacts: Heat Recovery Ventilation in Cold Climates

Over half of Alaska homes are at risk of poor indoor air quality, which increases the risk of respiratory and other illnesses for people and animals. Heat recovery ventilators (HRVs) provide warm, fresh air to a building interior while minimizing energy use. They can be programmed to provide varying amounts of fresh air to ensure adequate ventilation for occupants and can be configured to filter air during wildfires or other events. In addition to improving the safety of indoor air and extending the life of a building, HRVs can improve surrounding outdoor air because they reduce the amount of fossil fuels needed to heat a building. Recent research by CCHRC has focused on lowering barriers to using HRVs in cold climates through laboratory evaluations and homeowner education. This poster will cover data on indoor air quality in Alaska, results of CCHRC research, and future research questions.

buildings↗

WIPP Safety Significant Confinement Ventilation System Design - 18490

A large exhaust ventilation system has been designed to provide continuous HEPA filtration of the exhaust from the Waste Isolation Pilot Plant (WIPP) underground while meeting the demand for expanded waste emplacement and mining operations over the next 40 years. The WIPP Safety Significant Confinement Ventilation System (SSCVS) design provides secondary confinement to mitigate the consequences of a postulated radiological release in the underground. The SSCVS design specifically addresses the radiological incident that occurred in 2014 by providing Safety Significant secondary confinement and continuous HEPA filtration over a wide range of operating and environmental conditions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WIPP Safety Significant Confinement Ventilation System (SSCVS) Quality Assurance Program - 20237

Construction and major equipment fabrication are underway for a new ventilation exhaust system at the Waste Isolation Pilot Plant (WIPP). The new system will provide continuous HEPA filtration of the exhaust from the WIPP underground while meeting the ventilation demands for expanded waste emplacement and mining operations over the next 40 years. The SSCVS project has proceeded with the awarding of CD-3A for Long Lead Procurements followed by CD-2/3 approval for the construction of the facilities. The SSCVS project team made the decision to increase the quality oversight throughout the complete project per the Project Quality Assurance Plan (PQAP) such that it can ensure the final products meet applicable NQA-1 requirements and general quality requirements, and that the project will proceed to operations without significant delays due to post installation quality concerns. The PQAP was established prior to approval of the project at the CD-2/3 milestone. The SSCVS project has 2 major long lead procurements which commenced with the awarding of CD-3A. These procurements include the HEPA filter housing assemblies and the Exhaust Fans. There are 22 HEPA filter assemblies for the SSCVS, which are designated Safety Significant for pressure boundary confinement, per the approved PDSA. The exhaust fans also have Safety Significant components to maintain the pressure confinement boundary. NWP made the decision to install resident Quality Inspectors at the fabrication facilities to ensure the documentation for each fabricated unit meets all the QA requirements as defined in the respective contract documents. For the construction of the SSCVS Salt Reduction Building (SRB) and New Filter Building (NFB), dedicated, on-site quality inspectors have been utilized to ensure that all work being performed will comply with quality requirements and the Special Inspections as defined in IBC-2015. At each stage of inspection, hold points are placed into the work packages to ensure NWP QA personnel are present to inspect and verify the installations are in accordance with the design specifications, codes and standards. With this level of oversight, NWP anticipates that the level of quality related issues, as seen on multiple other DOE complex site projects, will be avoided and that the commissioning, start-up and hot operations will progress in a timely fashion, as all documentation will be in place and approved prior to initiation of these activities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WIPP Safety Significant Confinement Ventilation System (SSCVS) HEPA Filtration System - 20165

Construction and major equipment fabrication are underway for a new ventilation exhaust system at the Waste Isolation Pilot Plant (WIPP). The new system will provide continuous High Efficiency Particulate Air (HEPA) filtration of the exhaust from the WIPP underground while meeting the ventilation demands for expanded waste emplacement and mining operations over the next 40 years. The integrated system design provides for reducing the salt, clay and diesel particulates from the exhaust airflow from the mine, prior to full filtration using Nuclear Safety Significant HEPA filters. The SSCVS design and equipment provides for continuous HEPA filtration over a wide range of operating and environmental conditions. The new exhaust system connects to the existing underground exhaust shaft, and the exhaust air flows from the underground through Salt Reduction Units (SRUs) to protect the final filter banks from excessive moisture and rapid salt/dust buildup. Each of the six (6) SRUs consists of a demister to remove entrained moisture, a dry salt remover unit to filter approximately 90% of the entrained salt/dust, and an automated water treatment system to periodically clean the demisters and to remove salt from the SRU filters. At the maximum expected exhaust flowrate of 540,000 Cubic Feet per Minute (CFM) / 255 Cubic Meters per Second (m{sup 3}/s), five (5) salt removal units will be in operation with one unit in standby or maintenance. An in-line variable frequency drive booster fan will offset pressure losses through each SRU and reduce the relative humidity of the air exiting the SRUs. In the event of a high radiation alarm from the underground Continuous Air Monitors (CAMs), the SRUs will be automatically bypassed, which places the SRS and building outside of the Safety Significant confinement boundary. From the SRUs, the exhaust is directed to the HEPA filter banks located in the New Filter Building. The exhaust system is designed to provide continuous HEPA filtration prior to release to the exhaust stack. There are 22 HEPA filter banks rated at 27,000 CFM / 12.75 m{sup 3}/s each. Each filter bank has two stages of pre-filters and two stages of HEPA filters. The filtered air from each of the 22 filter banks discharges into a common concrete plenum, which is maintained under a negative pressure by the main exhaust fans. Six 1,000 HP variable frequency drive exhaust fans are provided on the south side of the plenum. At the maximum expected exhaust flow of 540,000 CFM, four exhaust fans and twenty filter banks will be in operation. The fans discharge vertically to a separate concrete exhaust plenum. The filtered exhaust is routed from the exhaust plenum to a 125-foot-tall exhaust stack via a 13-foot diameter duct. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High-Frequency Jet Ventilation During Cryoablation of Small Renal Tumours

AimTo evaluate the effect of high-frequency jet ventilation (HFJV) in place of standard intermittent positive-pressure ventilation (IPPV) on procedure duration, patient radiation dose, complication rates, and outcomes during CT-guided cryoablation of small renal tumours.Materials and MethodsOne hundred consecutive CT-guided cryoablation procedures to treat small renal tumours under general anaesthesia were evaluated—50 with standard IPPV and 50 after the introduction of HFJV as standard practice. Anaesthesia and procedural times, ionising radiation dose, complications, and 1-month post-treatment outcomes were collected.ResultsHFJV was feasible and safe in all cases. Mean procedure time and total anaesthetic time were shorter with HFJV (p = <0.0001). The number of required CT acquisitions (p = 0.0002) and total procedure patient radiation dose (p = 0.0027) were also lower in the HFJV group compared with the IPPV group. There were a total of four complications of Clavien–Dindo classification 3 or above—three in the IPPV group and one in the HFJV group. At 1-month follow-up, two cases (both in the IPPV group) demonstrated subtotal treatment. Both cases were subsequently successfully retreated with cryoablation.ConclusionBy reducing target tumour motion during CT-guided renal cryoablation, HFJV can reduce procedure times and exposure to ionising radiation. HFJV provides an important adjunct to complex image-guided interventions, with potential to improve safety and treatment outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined Ventilation and Perfusion Imaging Correlates With the Dosimetric Parameters of Radiation Pneumonitis in Radiation Therapy Planning for Lung Cancer

Purpose: The purpose of this study was to prospectively investigate clinical correlations between dosimetric parameters associated with radiation pneumonitis (RP) and functional lung imaging. Methods and Materials: Functional lung imaging was performed using four-dimensional computed tomography (4D-CT) for ventilation imaging, single-photon emission computed tomography (SPECT) for perfusion imaging, or both (V/Q-matched region). Using 4D-CT, ventilation imaging was derived from a low attenuation area according to CT numbers below different thresholds (vent-860 and -910). Perfusion imaging at the 10th, 30th, 50th, and 70th percentile perfusion levels (F10-F70) were defined as the top 10%, 30%, 50%, and 70% hyperperfused normal lung, respectively. All imaging data were incorporated into a 3D planning system to evaluate correlations between RP dosimetric parameters (where fV20 is the percentage of functional lung volume irradiated with >20 Gy, or fMLD, the mean dose administered to functional lung) and the percentage of functional lung volume. Radiation pneumonitis was evaluated using Common Terminology Criteria for Adverse Events version 4.0. Statistical significance was defined as a P value of <.05. Results: Sixty patients who underwent curative radiation therapy were enrolled (48 patients for non-small cell lung cancer, and 12 patients for small cell lung cancer). Grades 1, 2, and ≥3 RP were observed in 16, 44, and 6 patients, respectively. Significant correlations were observed between the percentage of functional lung volume and fV20 (r=0.4475 in vent-860 and 0.3508 in F30) or fMLD (r=0.4701 in vent-860 and 0.3128 in F30) in patients with grade ≥2 RP. F30∩vent-860 results exhibited stronger correlations with fV20 and fMLD in patients with grade ≥2 (r=0.5509 in fV20 and 0.5320 in fMLD) and grade ≥3 RP (r=0.8770 in fV20 and 0.8518 in fMLD). Conclusions: RP dosimetric parameters correlated significantly with functional lung imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-149: Establishing the Relationship Between Pre-Treatment Lung Ventilation, Dose, and Toxicity Outcome

Purpose: Recently, there has been an interest in incorporating functional information in treatment planning especially in thoracic tumors. The rationale is that healthy lung regions need to be spared from radiation if possible to help achieve better control on toxicity. However, it is still unclear whether high functioning regions need to be spared or have more capacity to deal with the excessive radiation as compared to the compromised regions of the lung. Our goal with this work is to establish the tools by which we can establish a relationship between pre-treatment lung function, dose, and radiographic outcomes of lung toxicity. Methods: Treatment planning was performed using a single phase of a 4DCT scan, and follow-up anatomical CT scans were performed every 3 months for most patients. In this study, we developed the pipeline of tools needed to analyze such a large dataset, while trying to establish a relationship between function, dose, and outcome. Pre-treatment lung function was evaluated using a recently published technique that evaluates Fractional Regional Ventilation (FRV). All images including the FRV map and the individual follow-up anatomical CT images were all spatially matched to the planning CT using a diffusion based Demons image registration algorithm. Change in HU value was used as a metric to capture the effects of lung toxicity. To validate the findings, a radiologist evaluated the follow-up anatomical CT images and scored lung toxicity. Results: Initial experience in 1 patient shows a relationship between the pre-treatment lung function, dose and toxicity outcome. The results are also correlated to the findings by the radiologist who was blinded to the analysis or dose. Conclusion: The pipeline we have established to study this enables future studies in large retrospective studies. However, the tools are dependent on the fidelity of 4DCT reconstruction for accurate evaluation of regional ventilation. Patent Pending for the technique presented in this work to evaluate FRV incorporating mass correction.

60 APPLIED LIFE SCIENCES↗

TU-F-17A-09: Four-Dimensional Cone Beam CT Ventilation Imaging Can Detect Interfraction Lung Function Variations for Locally Advanced Lung Cancer Patients

Purpose: Four-dimensional cone beam CT ventilation imaging (4D-CBCT VI) is a novel functional lung imaging modality requiring validation. We hypothesize that 4D-CBCT VI satisfies a necessary condition for validity: that intrafraction variations (e.g. due to poor 4D-CBCT image quality) are substantially different to interfraction variations (e.g. due to changes in underlying function). We perform the first comparison of intrafraction (pre/post fraction) and interfraction (week-to-week) 4D-CBCT VIs for locally advanced non small cell lung cancer (LA NSCLC) patients undergoing radiation therapy. Methods: A total of 215 4D-CBCT scans were acquired for 19 LA NSCLC patients over 4-6 weeks of radiation therapy, including 75 pairs of pre-/post-fraction scans on the same day. 4D-CBCT VIs were obtained by applying state-of-the-art, B-spline deformable image registration to obtain the Jacobian determinant of deformation between the end-exhale and end-inhale phases. All VIs were deformably registered to the corresponding first day scan, normalized between the 10th and 90th percentile values and cropped to the ipsilateral lung only. Intrafraction variations were assessed by computing the mean and standard deviation of voxel-wise differences between all same-day pairs of pre-/post-fraction VIs. Interfraction differences were computed between first-day VIs and treatment weeks 2, 4 and 6 for all 19 patients. We tested the hypothesis by comparing cumulative distribution functions (CDFs) of intrafraction and interfraction ventilation differences using two-sided Kolmogorov-Smirnov goodness-of-fit tests. Results: The (mean ± std. dev.) of intrafraction differences was (−0.007 ± 0.079). Interfraction differences for weeks 2, 4 and 6 were (−0.035 ± 0.103), (−0.006 ± 0.094) and (−0.019 ± 0.127) respectively. For week 2, the changes in CDFs for intrafraction and interfraction differences approached statistical significance (p=0.099). Conclusion: We have shown that 4D-CBCT VI can satisfy a necessary condition for validity; intrafraction variations do not limit the ability to measure interfraction variations in LA NSCLC patients. This work is supported by a Cancer Institute NSW Early Career Fellowship, an NHMRC Australia Fellowship and NIH P01CA116602.

60 APPLIED LIFE SCIENCES↗

Surface-to-Interior Transport Timescales and Ventilation Patterns in a Time-Dependent Circulation Driven by Sustained Climate Warming

Abstract The effect of climate warming in response to rising atmospheric CO 2 on the ventilation of the ocean remains uncertain. Here we make theoretical advances in elucidating the relationship between ideal age and transit time distribution (TTD) in a time-dependent flow. Subsequently, we develop an offline tracer-transport model to characterize the ventilation patterns and time scales in the time-evolving circulation for the 1850–2300 period as simulated with the Community Earth System Model version 1 (CESMv1) under a business-as-usual warming scenario. We found that by 2300 2.1% less water originates from the high-latitude deep water formation regions (both hemispheres) compared to 1850. In compensation, there is an increase in the water originating from the subantarctic. We also found that slowing meridional overturning circulation causes a gradual increase in mean age during the 1850–2300 period, with a globally averaged mean-age increase of ∼110 years in 2300. Where and when the water will be re-exposed to the atmosphere depends on the post-2300 circulation. For example, if we assume that the circulation persists in its year-2300 state (scenario 1), the mean interior-to-surface transit time in year 1850 is ∼1140 years. In contrast, if we assume that the circulation abruptly recovers to its year-1850 state (scenario 2), the mean interior-to-surface transit time in 1850 is only ∼740 years. By 2300, these differences become even larger; in scenario 1, the mean interior-to-surface transit time increases by ∼200 years, whereas scenario 2 decreases by ∼80 years. The dependence of interior-to-surface transit time on the future ocean circulation produces an additional unavoidable uncertainty in the long-term durability of marine carbon dioxide removal strategies. Significance Statement The ocean’s circulation, when altered by climate warming, can affect its capacity to absorb heat and CO 2 , which are crucial for the global climate. In our study, we investigated how global warming, caused by rising CO 2 levels, might impact the ocean circulation—the way water moves from deep ocean to the surface and vice versa. We discovered that by 2300, if we continue on our current warming trajectory, the origins of water within the ocean will shift, with less coming from deep, cold zones near the poles and more from subantarctic regions. As a result, deep water will take longer time before it resurfaces than shallow water. How quickly this water travels from deep regions to the surface could change, depending on the state of future ocean circulation. If the circulation remains as predicted in 2300, this journey will take longer. Conversely, if it reverts to the pattern in 1850, the process will be quicker. This variability introduces added uncertainty to strategies aimed at mitigating climate change by storing CO 2 in the ocean. Our work highlights the intricate ways in which climate change can influence our oceans, potentially affecting our plans to mitigate global warming.

54 ENVIRONMENTAL SCIENCES↗

Assessing Air Velocity Distribution in Three Sizes of Commercial Broiler Houses During Tunnel Ventilation

Abstract. Convective cooling is a critical management strategy for maintaining an environment that promotes production efficiency, thermal comfort, and animal well-being in commercial broiler houses. Variations in house size, design, and equipment configuration contribute greatly to the air velocity distribution within the facility. This study assessed total airflow, air velocity distribution, and quantified the floor area in three facilities experiencing insufficient air velocity for maintenance of production efficiency, thermal comfort, and animal well-being. Test facility 1 was an 18.3 × 170.7 m solid side-wall broiler house, test facility 2 was a 15.24 × 144.8 m solid side-wall broiler house, and test facility 3 was a 12.19 × 121.9 m curtain side-wall broiler house. Total airflow of each facility, measured with a Fan Assessment and Numeration System, was 512,730, 389,495, and 329,270 m 3 h -1 for test facilities 1, 2, and 3, respectively. Air velocity distribution patterns were characterized in each house with a Scalable Environment Assessment System (SEAS) and spatial statistics. The air velocity distributions within the test facilities were variable, with notable maxima immediately downstream of the tunnel inlets, which serve as a well-defined vena contracta, and local minima near the leading end of the evaporative pads and the exhaust fans. Equipment within the facilities had an impact on the air velocity distribution by creating reduced cross-sectional areas that resulted in localized increases in air velocity. The percentage of total bird-level floor area in each facility experiencing air velocities below 1.5 m s -1 was 14.3%, 20.7%, and 10.0% for test facilities 1, 2, and 3, respectively. The effective design velocity (V ed ) was calculated from total airflow using the measured building cross-sectional area. The V ed measured 2.97, 2.45, and 2.34 m s -1 for test facilities 1, 2, and 3, respectively. Mean cross-sectional air velocity (V cs ) was calculated from SEAS data and normalized using each facility’s V ed to account for differences in building size for comparison. Test facility 1, the largest of the three houses, generated substantially higher V cs /V ed than test facilities 2 and 3. Test facilities 2 and 3 maintained a larger proportion of V cs above V ed than test facility 1. Test facility 1 showed 26.5% of the total house length below V ed , while test facilities 2 and 3 had only 20.8% and 17.5%, respectively, of the total house length below V ed . The lower-velocity regions were due to the length of the evaporative cooling pad inlet and the use of tunnel doors, and the exhaust fan placement on the side-walls in test facility 1 created an additional pronounced low-velocity area. Placement of tunnel ventilation fans on the end-wall of the facility, rather than the side-wall, eliminated the low-velocity region at the exhaust end of the facility. Modifications to current practices for broiler production facility construction and evaporative cooling pad inlet installation would be required to minimize the low-velocity region at the inlet end of these facilities. Consideration of house width and physical arrangement of the air inlets, tunnel fans, and internal equipment are critical for improving the uniformity of air velocity in commercial broiler houses. Keywords: Air velocity, Anemometer, Broiler house, FANS, Tunnel ventilation.

Agriculture↗

New Air Cleaning Strategies for Reduced Commercial Building Ventilation Energy - FY11 (Final Report)

The research carried out in this project focuses on developing novel volatile organic compounds (VOCs) air cleaning technologies needed to enable energy-saving reductions in ventilation rates. we targeted a VOC air cleaning system that could enable a 50% reduction in ventilation rates. In a typical commercial HVAC system that provides a mixture of recirculated and outdoor air, a VOC air cleaner in the supply airstream must have a 15% to 20% VOC removal efficiency to counteract a 50% reduction in outdoor air supply.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and Integrate Improved Systems for Nuclear Facility Ventilation and Exhaust Operations

Objective: The objective of this R&D project would complete the development of three new systems and integrate them into a single experimental effort. However, each of the three systems has stand-alone applicability across the DOE complex. At US DOE nuclear facilities, indoor air is filtered and ventilated for human occupancy, and exhaust air to the outdoor environment must be regulated and monitored. At least three technical standards address these functions, and the Los Alamos National Laboratory would complete an experimental facility to answer at least three questions: (1) Can the drag coefficient of a new Los Alamos air mixer be reduced for better operation in nuclear facility exhaust stacks? (2) Is it possible to verify the accuracy of a new dilution method for HEPA filter test facilities? (3) Is there a performance-based air flow metric (volumetric flow or mass flow) for operating HEPA filters? In summary, the three new systems are: a mixer, a diluter and a performance-based metric, respectively. The results of this project would be applicable to at least four technical standards: ANSI N13.1 Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities; ASTM F1471 Standard Test Method for Air Cleaning Performance of a High-Efficiency Particulate Air Filter System, ASME N511: In-Service Testing of Nuclear Air Treatment, Heating, Ventilating, and Air-Conditioning Systems, and ASME AG-1: Code On Nuclear Air And Gas Treatment. All of the three proposed new systems must be combined into a single experimental device (i.e. to develop a new function of the Los Alamos aerosol wind tunnel). Technical Approach: The Radiation Protection RP-SVS group at Los Alamos has an aerosol wind tunnel that was originally (2006) designed to evaluate small air samplers (cf. US EPA 40 CFR 53.42). In 2009, the tunnel was modified for exhaust stack verifications per the ANSI N13.1 standard. In 2010, modifications were started on the wind tunnel for testing HEPA filters (cf. ASTM F1471 and ASME N511). This project involves three systems that were developed for testing the 24*24*11 (inch) HEPA filters (i.e. the already mentioned mixer, diluter and metric). Prototypes of the mixer and the diluter have been built and individually tested on a preliminary basis. However, the third system (the HEPA metric method) has not been tested, since that requires complete operability of the aerosol wind tunnel device. (The experimental wind tunnel has test aerosol injection, control and measurement capabilities, and can be heated for temperature dependent measurements.) Benefits: US DOE facilities that use HEPA filters and/or require exhaust stacks from their nuclear facility buildings will benefit from access to the new hardware (mixer and diluter) and performance-based metric (for HEPA filter air flow).

61 RADIATION PROTECTION AND DOSIMETRY↗

Healthy Zero Energy Buildings (HZEB) Program Interim Report on Cross Sectional Study of Contaminant Levels, Source Strengths, and Ventilation Rates in Retail Stores

The HZEB research program aims to generate information needed to develop new science-based commercial building ventilation rate (VR) standards that balance the dual objectives of increasing energy efficiency and maintaining acceptable indoor air quality. This interim report describes the preliminary results from one HZEB field study on retail stores. The primary purpose of this study is to estimate the whole-building source strengths of contaminant of concerns (COCs). This information is needed to determine the VRs necessary to maintain indoor concentrations of COCs below applicable health guidelines.The goal of this study is to identify contaminants in retail stores that should be controlled via ventilation, and to determine the minimum VRs that would satisfy the occupant health and odor criteria.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating Ventilation Systems for Existing Homes

In an effort to improve housing options near Las Vegas, Nevada, the Clark County Community Resources Division (CCCRD) performs substantial renovations to foreclosed homes. After dramatic energy, aesthetic, and health and safety improvements are made, homes are rented or sold to qualified residents. This report describes the evaluation and selection of ventilation systems for these homes, including key considerations when selecting an ideal system. The report then describes CCCRD’s decision process with respect to ventilation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy and IAQ Implications of Alternative Minimum Ventilation Rates in California Retail and School Buildings

For a stand-alone retail building, a primary school, and a secondary school in each of the 16 California climate zones, the EnergyPlus building energy simulation model was used to estimate how minimum mechanical ventilation rates (VRs) affect energy use and indoor air concentrations of an indoor-generated contaminant. The modeling indicates large changes in heating energy use, but only moderate changes in total building energy use, as minimum VRs in the retail building are changed. For example, predicted state-wide heating energy consumption in the retail building decreases by more than 50% and total building energy consumption decreases by approximately 10% as the minimum VR decreases from the Title 24 requirement to no mechanical ventilation. The primary and secondary schools have notably higher internal heat gains than in the retail building models, resulting in significantly reduced demand for heating. The school heating energy use was correspondingly less sensitive to changes in the minimum VR. The modeling indicates that minimum VRs influence HVAC energy and total energy use in schools by only a few percent. For both the retail building and the school buildings, minimum VRs substantially affected the predicted annual-average indoor concentrations of an indoor generated contaminant, with larger effects in schools. The shape of the curves relating contaminant concentrations with VRs illustrate the importance of avoiding particularly low VRs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of Tank 22 Demister Solids Responsible for Preventing Adequate Purge Ventilation Flow (U)

In December 2020, about 2.5 grams of the solid material from the Tank 22 purge ventilation demister, responsible for preventing adequate purge ventilation flow, were delivered to Savannah River National Laboratory (SRNL) by Savannah River Remediation (SRR) for analysis to identify the chemical nature of the solids and possibly address why fresh water and caustic flushes with 50 wt. % sodium hydroxide solution are essentially ineffective in dissolving or dislodging the accumulated solids from the Tank 22 demister at low ambient temperature conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technology assessment to reduce aerosol transmission risk in naturally ventilated K12 classrooms (CRADA Final Report)

LBNL provided technical assistance to Oakland Unified School District (OUSD) through this project in their selection of technologies to support in-person instruction. OUSD considered different technologies to mitigate the aerosol transmission risks of COVID-19: a) Upgrade to higher efficiency air filters in buildings that are served by heating, ventilation, and air conditioning (HVAC) systems. b) Install portable air cleaners with HEPA (high efficiency particulate air) filters. c) Install ultraviolet germicidal irradiation (UVGI) systems. d) Install bipolar ionization air cleaning systems. LBNL met with OUSD facilities staff to discuss the pros and cons of options a) and c), and cited the lack of proven data on efficacy and discouraged option d). LBNL provided practical guidance on how to select portable air cleaners for classrooms. LBNL met with the boarder school communities to explain OUSD approach to ventilation and filtration, and produced FAQs to answer their questions about the science behind the selected approaches. In addition, LBNL helped OUSD facilities staff to acquire five indoor air quality (IAQ) monitors (AirVisual Pro by IQAir) for measuring carbon dioxide (CO2) and particulate matter (PM) concentrations. These monitors were installed in an elementary school in West Oakland.

60 APPLIED LIFE SCIENCES↗