Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VEIN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

High-Pressure Minerals in Meteorites: Constraints on Shock Conditions and Duration

The objective of this research was to better understand the conditions and duration of shock metamorphism in meteorites through microstructural and microanalytical characterization of high-pressure minerals. A) Continue to investigate the mineralogy and microstructures of melt-veins in a suite of chondritic samples ranging from shock grades S3 through S6 to determine how the mineral assemblages that crystallize at high-pressure and are related to shock grade. B) Investigate the chemical, mineralogical, and microstructural heterogeneities that occur across melt veins to interpret crystallization histories. C) Use static high-pressure experiments to simulate crystallization of melt veins for mineralogical and textural comparisons with the melt veins of naturally shocked samples. D) Characterize the compositions and defect microstructures of polycrystalline ringwoodite, wadsleyite, majorite, (Mg,Fe)Si03-ilmenite and (Mg,Fe)SiO3-perovskite in S6 samples to understand the mechanisms of phase transformations that occur during shock. These results will combined with kinetic data to constrain the time scales of kinetic processes. E) Investigate the transformations of metastable high-pressure minerals back to low- pressure forms to constrain post-shock temperatures and estimates of the peak shock pressure. Of these objectives, we have obtained publishable data on A, B and D. I am currently doing difficult high-pressure melting and quench experiments on an L chondrite known as Mbale. These experiments will provide additional constraints on the mineral assemblages that are produced during rapid quench of an L chondrite at pressures of 16 to 25 GPa. Results from published or nearly published research is presented below. Lists of theses, dissertations and publications are given below.

Sharp, Thomas G.↗

Atrial development in the human heart: an immunohistochemical study with emphasis on the role of mesenchymal tissues

The development of the atrial chambers in the human heart was investigated immunohistochemically using a set of previously described antibodies. This set included the monoclonal antibody 249-9G9, which enabled us to discriminate the endocardial cushion-derived mesenchymal tissues from those derived from extracardiac splanchnic mesoderm, and a monoclonal antibody recognizing the B isoform of creatine kinase, which allowed us to distinguish the right atrial myocardium from the left. The expression patterns obtained with these antibodies, combined with additional histological information derived from the serial sections, permitted us to describe in detail the morphogenetic events involved in the development of the primary atrial septum (septum primum) and the pulmonary vein in human embryos from Carnegie stage 14 onward. The level of expression of creatine kinase B (CK-B) was found to be consistently higher in the left atrial myocardium than in the right, with a sharp boundary between high and low expression located between the primary septum and the left venous valve indicating that the primary septum is part of the left atrial gene-expression domain. This expression pattern of CK-B is reminiscent of that of the homeobox gene Pitx2, which has recently been shown to be important for atrial septation in the mouse. This study also demonstrates a poorly appreciated role of the dorsal mesocardium in cardiac development. From the earliest stage investigated onward, the mesenchyme of the dorsal mesocardium protrudes into the dorsal wall of the primary atrial segment. This dorsal mesenchymal protrusion is continuous with a mesenchymal cap on the leading edge of the primary atrial septum. Neither the mesenchymal tissues of the dorsal protrusion nor the mesenchymal cap on the edge of the primary septum expressed the endocardial tissue antigen recognized by 249-9G9 at any of the stages investigated. The developing pulmonary vein uses the dorsal mesocardium as a conduit to reach the primary atrial segment. Initially, the pulmonary pit, which will becomes the portal of entry for the pulmonary vein, is located along the midline, flanked by two myocardial ridges. As development progresses, tissue remodeling results in the incorporation of the portal of entry of the pulmonary vein in left atrial myocardium, which is recognized because of its high level of creatine. Closure of the primary atrial foramen by the primary atrial septum occurs as a consequence of the fusion of these mesenchymal structures. Copyright 2000 Wiley-Liss, Inc.

NASA Discipline Cardiopulmonary↗

Role for Lower Extremity Interstitial Fluid Volume Changes in the Development of Orthostasis after Simulated Microgravity

Reentry orthostasis after exposure to the conditions of spaceflight is a persistent problem among astronauts. In a previous study, a computer model systems analysis was used to examine the physiologic mechanisms involved in this phenomenon. In this analysis, it was determined that an augmented capacitance of lower extremity veins due to a fluid volume contracture of the surrounding interstitial spaces during spaceflight results in an increase in sequestered blood volume upon standing and appears to be the initiating mechanism responsible for reentry orthostasis. In this study, we attempt to validate the central premise of this hypothesis using a ground-based spaceflight analog. 10 healthy subjects were placed at bed rest in a 6 head down tilt position for 60 days of bed rest. The impact of adaptations in interstitial fluid volume and venous capacitance in the lower extremities were then observed during a standard tilt test protocol performed before and after the confinement period. The interstitial thickness superficial to the calcaneous immediately below the lateral malleolus was measured using ultrasound with a 17-5 MHz linear array transducer. Measurements of the changes in anterior tibial vein diameter during tilt were obtained by similar methods. The measurements were taken while the subjects were supine and then during upright tilt (80') for thirty minutes, or until the subject had signs of presyncope. Additional measurements of the superficial left tibia interstitial thickness and stroke volume by standard echocardiographic methods were also recorded. In addition, calf compliance was measured over a pressure range of 10-60 mmHg, using plethysmography, in a subset of these subjects (n = 5). There was a average of 6% diminution in the size of the lower extremity interstitial space as compared to measurements acquired prior to bed rest. This contracture of the interstitial space coincided with a subsequent relative increase in the percentage change in tibial vein diameter and stroke volume upon tilting in contrast to the observations made before bed rest (54 vs 23% respectively). Compliance in the calf increased by an average of 36% by day 27 of bedrest. A systems analysis using a computer model of cardiovascular physiology suggests that microgravity induced interstitial volume depletion results in an accentuation of venous blood volume sequestration and is the initiating event in reentry orthostasis. This hypothesis was tested in volunteer subjects using a ground-based spaceflight analog model that simulated the body fluid redistribution induced by microgravity exposure. Measurements of changes in the interstitial spaces and observed responses of the anterior tibial vein with tilt, together with the increase in calf compliance, were consistent with our proposed mechanism for the initiation of postflight orthostasis often seen in astronauts.

Platts, Steven H.↗

Initial Observations by the Mars Exploration Rover Opportunity at Cape York, Meridiani Planum

Since the beginning of its mission, the MER rover Opportunity has visited a sequence of progressively larger impact craters in order to characterize rocks that represent an ever broader stratigraphic range. Endeavour Crater is by far the largest crater that this rover has visited, therefore the crater rim provides materials from strata that are much deeper and older than any materials yet sampled. Indeed, the Mars Reconnaissance Orbiter CRISM instrument detected spectral signatures of hydrated phyllosilicates in several rim segments, consistent with a Noachian provenance. In addition, the crater rim might have recorded the effects of the original impact as well as the thermal processes that occurred in its aftermath. This report summarizes initial observations of geologic structures and the fabrics, chemistry and mineralogy of rocks. Cape York is an N/NE - S/SW-trending segment of crater rim that is bounded by rim segments that are more deeply eroded, forming embayments. Opportunity drove onto the southwest margin of Cape York and has traversed across the Cape to a ridge near its northern end. The rim of Endeavour Crater was severely degraded and then on lapped by Meridiani sulfate-rich deposits, indicating that Cape York deposits experienced extensive erosion prior to the deposition of Meridiani Planum sulfate-rich sediments. Cape York consists of impact-uplifted rocks that are surrounded by a younger bedrock bench that might represent sediments shed from Cape York. The uplifted rock "Tisdale-2," located near the southern end of Cape York, is a polymict lithic breccia. Its elemental composition resembles a mixture of basalt plus bedrock encountered previously at Meridiani Planum, and it is relatively enriched in Ni, Zn, P, characteristic of hydrothermal fluids. "Chester Lake" and "Greeley Haven" are bedrock surfaces located near the southern and northern ends of Cape York, respectively, and they exhibit fabrics reminiscent of suevites. The rocks that were analyzed so far are quite different from any rocks previously encountered by Opportunity and Spirit. Several light-toned vein deposits (approx 1 cm) were discovered in the bench that borders the western flanks of Cape York. The vein "Homestake" is rich in Ca and S, and it exhibits a spectral feature near 1000 run caused by hydration, indicating that "Homestake" consists substantially of gypsum. The relationship(s) between these veins and the sulfate-rich layered deposits at Meridiani Planum remains uncertain. The veins might have been deposited by sulfate-rich fluids perhaps either in the immediate aftermath of the impact that formed Endeavour Crater or at some later time. Current uncertainties notwithstanding, the novel lithologies at Cape York are significantly older than the sulfate-rich sedimentary rocks at Meridiani Planum, and these lithologies have recorded episodes of aqueous activity from earlier epochs, perhaps during the Noachian. The author acknowledges the contributions of the Athena Science Team, the MER engineering team, JPL and NASA.

Marais, David J.↗

Smyer H-Chondrite Impact-Melt Breccia and Evidence for Sulfur Vaporization

Smyer is an H-chondrite impact-melt breccia containing approx.20 vol% 0.5- to 13-mm-thick silicate-rich melt veins surrounding unmelted subrounded chondritic clasts up to 7 cm in maximum dimension. At the interface between some of the melt veins and chondritic clasts, there are troilite-rich regions consisting of unmelted. crushed 0.2- to 140-micron-size angular silicate grains and chondrule fragments surrounded by troilite and transected by thin troilite veins. Troilite fills every available fracture in the silicates. including some as thin as 0.1 microns. Little metallic Fe-Ni is present in these regions: the FeS/Fe modal ratio ranges from -25: 1 to approx.500: 1, far higher than the eutectic weight ratio of 7.5: 1. The texture of these regions indicates that the sulfide formed from a fluid of very low viscosity. The moderately high viscosity (0.2 poise) and large surface tension of liquid FeS, its inability to wet silicate grain surfaces at low oxygen fugacities. and the supereutectic FeS/Fe ratios in the troilite-rich regions indicate that the fluid was a vapor. It seems likely that during the shock event that melted Smyer, many silicates adjacent to the melt veins were crushed. Upon release of shock pressure. some of the troilite evaporated and dissociated. Molecules of S2 were transported and condensed into fractures and around tiny silicate grains: there, they combined with Fe from small adjacent metallic Fe-Ni grains to form troilite. The Ni content at the edges of some of these metal grains increased significantly; Co from these Ni-rich grains diffused into nearby kamacite. Impact-induced S volatilization may have played a major role in depleting the surface of 433 Eros (and other chondritic asteroids) in S.

Rubin, Alan E.↗

Fluid Shifts

NASA is focusing on long-duration missions on the International Space Station (ISS) and future exploration-class missions beyond low Earth orbit. Visual acuity changes observed after short-duration missions were largely transient, but more than 30% of ISS astronauts experience more profound, chronic changes with objective structural and functional findings such as papilledema and choroidal folds. Globe flattening, optic nerve sheath dilation, and optic nerve tortuosity also are apparent. This pattern is referred to as the visual impairment and intracranial pressure (VIIP) syndrome. VIIP signs and symptoms, as well as postflight lumbar puncture data, suggest that elevated intracranial pressure (ICP) may be associated with the space flight-induced cephalad fluid shifts, but this hypothesis has not been tested. The purpose of this study is to characterize fluid distribution and compartmentalization associated with long-duration space flight, and to correlate these findings with vision changes and other elements of the VIIP syndrome. We also seek to determine whether the magnitude of fluid shifts during space flight, as well as the VIIP-related effects of those shifts, is predicted by the crewmember's pre-flight condition and responses to acute hemodynamic manipulations (such as head-down tilt). Lastly, we will evaluate the patterns of fluid distribution in ISS astronauts during acute reversal of fluid shifts through application of lower body negative pressure (LBNP) interventions to characterize and explain general and individual responses. We will examine a variety of physiologic variables in 10 long-duration ISS crewmembers using the test conditions and timeline presented in the Figure below. Measures include: (1) fluid compartmentalization (total body water by D2O, extracellular fluid by NaBr, intracellular fluid by calculation, plasma volume by CO rebreathe, interstitial fluid by calculation); (2) forehead/eyelids, tibia, calcaneus tissue thickness (by ultrasound); (3) vascular dimensions by ultrasound (jugular veins, cerebral and carotid arteries, vertebral arteries and veins, portal vein); (4) vascular dynamics by MRI (head/neck blood flow, cerebrospinal fluid pulsatility); (5) ocular measures (optical coherence tomography, intraocular pressure, 2-dimensional ultrasound including optic nerve sheath diameter, globe flattening, and retina-choroid thickness, Doppler ultrasound of ophthalmic and retinal arteries, and veins); (6) cardiac variables by ultrasound (inferior vena cava, tricuspid flow and tissue Doppler, pulmonic valve, stroke volume, right heart dimensions and function, four-chamber views); and (7) ICP measures (tympanic membrane displacement, distortion-product otoacoustic emissions, and ICP calculated by MRI). On the ground, acute head-down tilt will induce cephalad fluid shifts, whereas LBNP will oppose these shifts. Controlled Mueller maneuvers will manipulate cardiovascular variables. Through interventions applied before, during, and after flight, we intend to fully evaluate the relationship between fluid shifts and the VIIP syndrome. This study has been selected for flight implementation and is one of the candidate investigations being considered for the one year mission.

Stenger, Michael↗

Fluid Shifts

NASA is focusing on long-duration missions on the International Space Station (ISS) and future exploration-class missions beyond low-Earth orbit. Visual acuity changes observed after short-duration missions were largely transient, but more than 50% of ISS astronauts experienced more profound, chronic changes with objective structural and functional findings such as papilledema and choroidal folds. Globe flattening, optic nerve sheath dilation, and optic nerve tortuosity also are apparent. This pattern is referred to as the visual impairment and intracranial pressure (VIIP) syndrome. VIIP signs and symptoms, as well as postflight lumbar puncture data, suggest that elevated intracranial pressure (ICP) may be associated with the spaceflight-induced cephalad fluid shifts, but this hypothesis has not been tested. The purpose of this study is to characterize fluid distribution and compartmentalization associated with long-duration spaceflight, and to correlate these findings with vision changes and other elements of the VIIP syndrome. We also seek to determine whether the magnitude of fluid shifts during spaceflight, as well as the VIIP-related effects of those shifts, is predicted by the crewmember's preflight conditions and responses to acute hemodynamic manipulations (such as head-down tilt). Lastly, we will evaluate the patterns of fluid distribution in ISS astronauts during acute reversal of fluid shifts through application of lower body negative pressure (LBNP) interventions to characterize and explain general and individual responses. METHODS: We will examine a variety of physiologic variables in 10 long-duration ISS crewmembers using the test conditions and timeline presented in the Figure below. Measures include: (1) fluid compartmentalization (total body water by D2O, extracellular fluid by NaBr, intracellular fluid by calculation, plasma volume by CO rebreathe, interstitial fluid by calculation); (2) forehead/eyelids, tibia, calcaneus tissue thickness (by ultrasound); (3) vascular dimensions by ultrasound (jugular veins, cerebral and carotid arteries, vertebral arteries and veins, portal vein); (4) vascular dynamics by MRI (head/neck blood flow, cerebrospinal fluid pulsatility); (5) ocular measures (optical coherence tomography, intraocular pressure, 2-dimensional ultrasound including optic nerve sheath diameter, globe flattening, and retina-choroid thickness, Doppler ultrasound of ophthalmic and retinal arteries, and veins); (6) cardiac variables by ultrasound (inferior vena cava, tricuspid flow and tissue Doppler, pulmonic valve, stroke volume, right heart dimensions and function, four-chamber views); and (7) ICP measures (tympanic membrane displacement, distortion-product otoacoustic emissions, and ICP calculated by MRI). On the ground, acute head-down tilt will induce cephalad fluid shifts, whereas LBNP will oppose these shifts. Controlled Mueller maneuvers will manipulate cardiovascular variables. Through interventions applied before, during, and after flight, we intend to fully evaluate the relationship between fluid shifts and the VIIP syndrome.

Stenger, M.↗

Fluid Shifts

Introduction. NASA's Human Research Program is focused on addressing health risks associated with long-duration missions on the International Space Station (ISS) and future exploration-class missions beyond low Earth orbit. Visual acuity changes observed after short-duration missions were largely transient, but now more than 50 percent of ISS astronauts have experienced more profound, chronic changes with objective structural findings such as optic disc edema, globe flattening and choroidal folds. These structural and functional changes are referred to as the visual impairment and intracranial pressure (VIIP) syndrome. Development of VIIP symptoms may be related to elevated intracranial pressure (ICP) secondary to spaceflight-induced cephalad fluid shifts, but this hypothesis has not been tested. The purpose of this study is to characterize fluid distribution and compartmentalization associated with long-duration spaceflight and to determine if a relation exists with vision changes and other elements of the VIIP syndrome. We also seek to determine whether the magnitude of fluid shifts during spaceflight, as well as any VIIP-related effects of those shifts, are predicted by the crewmember's pre-flight status and responses to acute hemodynamic manipulations, specifically posture changes and lower body negative pressure. Methods. We will examine a variety of physiologic variables in 10 long-duration ISS crewmembers using the test conditions and timeline presented in the figure below. Measures include: (1) fluid compartmentalization (total body water by D2O, extracellular fluid by NaBr, intracellular fluid by calculation, plasma volume by CO rebreathe, interstitial fluid by calculation); (2) forehead/eyelids, tibia, and calcaneus tissue thickness (by ultrasound); (3) vascular dimensions by ultrasound (jugular veins, cerebral and carotid arteries, vertebral arteries and veins, portal vein); (4) vascular dynamics by MRI (head/neck blood flow, cerebrospinal fluid pulsatility); (5) ocular measures (optical coherence tomography; intraocular pressure; 2-dimensional ultrasound including optic nerve sheath diameter, globe flattening, and retina-choroid thickness; Doppler ultrasound of ophthalmic and retinal arteries and veins); (6) cardiac variables by ultrasound (inferior vena cava, tricuspid flow and tissue Doppler, pulmonic valve, stroke volume, right heart dimensions and function, four-chamber views); and (7) ICP measures (tympanic membrane displacement, otoacoustic emissions). Pre- and post-flight, acute head-down tilt will induce cephalad fluid shifts, whereas lower body negative pressure will oppose these shifts. Controlled Mueller maneuvers will manipulate cardiovascular variables. Through interventions applied before, during, and after flight, we intend to fully evaluate the relationship between fluid shifts and the VIIP syndrome. Discussion. Ten subjects have consented to participate in this experiment, including the recent One-Year Mission crewmembers, who have recently completed R plus180 testing; all other subjects have completed pre-flight testing. Preliminary results from the One-Year Mission crewmembers will be presented, including measures of ocular structure and function, vascular dimensions, fluid distribution, and non-invasive estimates of intracranial pressure.

Stenger, M. B.↗

Reader agreement and accuracy of ultrasound features for hepatic steatosis

Purpose: The purpose of the study is to assess the reader agreement and accuracy of eight ultrasound imaging features for classifying hepatic steatosis in adults with known or suspected hepatic steatosis. Methods: This was an IRB-approved, HIPAA-compliant prospective study of adult patients with known or suspected hepatic steatosis. All patients signed written informed consent. Ultrasound images (Siemens S3000, 6C1HD, and 4C1 transducers) were acquired by experienced sonographers following a standard protocol. Eight readers independently graded eight features and their overall impression of hepatic steatosis on ordinal scales using an electronic case report form. Duplicated images from the 6C1HD transducer were read twice to assess intra-reader agreement. Intra-reader, inter-transducer, and inter-reader agreement were assessed using intraclass correlation coefficients (ICC). Features with the highest intra-reader agreement were selected as predictors for dichotomized histological steatosis using Classification and Regression Tree (CART) analysis, and the accuracy of the decision rule was compared to the accuracy of the radiologists’ overall impression. Results: 45 patients (18 males, 27 females; mean age 56 ± 12 years) scanned from September 2015 to July 2016 were included. Mean intra-reader ICCs ranged from 0.430 to 0.777, inter-transducer ICCs ranged from 0.228 to 0.640, and inter-reader ICCs ranged from 0.014 to 0.561. The CART decision rule selected only large hepatic vein blurring and achieved similar accuracy to the overall impression (74% to 75% and 68% to 72%, respectively). Conclusions: Large hepatic vein blurring, liver–kidney contrast, and overall impression provided the highest reader agreement. Large hepatic vein blurring may provide the highest classification accuracy for dichotomized grading of hepatic steatosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Power-Pulse Thrombolysis and Stent Recanalization for Acute Post-Liver Transplant Iliocaval Venous Thrombosis

Postoperative inferior vena cava (IVC) thrombosis is a potentially lethal complication in a liver transplant recipient. We report the case of a 57-year-old liver transplant recipient, who developed acute, postoperative, markedly symptomatic complete IVC, ilial-femoral-caval, and left renal vein thrombosis. After treatment with power-pulse tissue plasminogen activator thrombolysis, thrombectomy, and stent placement, the IVC and iliac veins were successfully recanalized. At 2.5-year imaging and laboratory follow-up, the IVC, iliac, and renal veins remained patent and graft function was preserved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early and Late Retrieval of the ALN Removable Vena Cava Filter: Results from a Multicenter Study

Retrieval of removable inferior vena cava (IVC) filters in selected patients is widely practiced. The purpose of this multicenter study was to evaluate the feasibility and results of percutaneous removal of the ALN removable filter in a large patient cohort. Between November 2003 and June 2006, 123 consecutive patients were referred for percutaneous extraction of the ALN filter at three centers. The ALN filter is a removable filter that can be implanted through a femoral/jugular vein approach and extracted by the jugular vein approach. Filter removal was attempted after an implantation period of 93 {+-} 15 days (range, 6-722 days) through the right internal jugular vein approach using the dedicated extraction kit after control inferior vena cavography. Following filter removal, vena cavograms were obtained in all patients. Successful extraction was achieved in all but one case. Among these successful retrievals, additional manipulation using a femoral approach was needed when the apex of the filter was close to the IVC wall in two patients. No immediate IVC complications were observed according to the postimplantation cavography. Neither technical nor clinical differences between early and late filter retrieval were noticed. Our data confirm the safety of ALN filter retrieval up to 722 days after implantation. In infrequent cases, additional endovenous filter manipulation is needed to facilitate extraction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Catheter-Directed Thrombolysis for Treatment of Deep Venous Thrombosis in the Upper Extremities

Traditional anticoagulant treatment of deep venous thrombosis (DVT) in the upper extremities (UEDVT) is associated with a relatively high incidence of postthrombotic syndrome (PTS). Catheter-directed thrombolysis (CDT) for UEDVT would provide efficient thrombolysis with less subsequent PTS than during traditional anticoagulation. Primary efficacy, complications, and long-term results after CDT are reported in a retrospective cohort (2002-2007) of patients (n = 30) with DVT in the upper extremities. PTS was assessed by a modified Villalta scale. UEDVT was unprovoked in 11 (37%) cases and effort related in 9 (30%) cases. The median duration of symptoms prior to CDT was 7.0 days (range, 1-30); median duration of thrombolysis treatment, 70 h (range, 24-264 h); and the median amount of rt-PA infused during CDT, 52 mg (range, 19-225 mg). Major bleeding was registered in three (9%) patients, and CDT was stopped prematurely in three patients due to local hematoma. No intracerebral bleeding, clinical pulmonary embolism, or deaths occurred during treatment. Grade II (>50%) or III (>90%) lysis was present in 29 patients (97%) at the end of CDT. Bleeding complications increased by each day of delay from the debut of symptoms to the start of treatment (OR, 1.20; 95% CI, 1.01-1.42). At follow-up (n = 29; median, 21 months; range, 5-58 months), 11 (38%) patients had occluded veins, whereas 18 (62%) had patent veins. However, stenosis of varying severity was present in eight of those with a patent vein. No patients had severe PTS, whereas six (21%) experienced mild PTS. In conclusion, our retrospective cohort study of patients with UEDVT showed that treatment restored venous drainage, with a subsequent low frequency of mild PTS at follow-up. Early intervention with CDT prevented bleeding complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovenous Laser Ablation as a Treatment for Postsurgical Recurrent Saphenous Insufficiency

The purpose of this study was to investigate the safety and efficacy of endovenous laser ablation as a treatment for recurrent symptomatic saphenous insufficiency occurring after saphenous vein ligation and stripping. A single-center retrospective review of patients who received endovenous laser ablation as a treatment for recurrent symptomatic saphenous insufficiency after ligation and stripping between November 2003 and October 2006 was performed. Fifty-six insufficient saphenous systems were identified in 38 patients. Follow-up consisted of a clinical examination in all patients as well as selective lower-extremity duplex ultrasound as clinically indicated. All 38 patients demonstrated complete closure of the insufficient saphenous vein by clinical examination and/or duplex ultrasound evaluation. Preoperative symptoms resolved after treatment in all 38 patients. No major complications were identified. Endovenous laser ablation of recurrent symptomatic saphenous venous insufficiency is a safe and effective treatment in patients who develop recurrent symptoms after saphenous vein ligation and stripping.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Selective Embolectomy using a Fogarty Thru-Lumen Catheter for Pancreas Graft Thrombosis: A Case Report

A 57-year-old woman with a history of diabetes mellitus underwent simultaneous pancreas-kidney transplantation. The pancreaticoduodenal graft was implanted in the right iliac fossa. The donor's portal vein was anastomosed to the recipient's inferior vena cava (IVC). Seven days after the surgery, a thrombus was detected in the graft veins. Percutaneous thrombolysis was immediately performed; however, venous congestion was still present. We therefore attempted selective embolectomy using a Fogarty Thru-Lumen Catheter. Thrombi were directed from the graft veins toward the IVC and captured in the IVC filter with complete elimination of the thrombus without any major complications. We present our technique for the successful treatment of pancreas graft thrombosis within a short time period by percutaneous selective embolectomy using a Fogarty Thru-Lumen Catheter.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pull-Through Technique for Recanalization of Occluded Portosystemic Shunts (TIPS): Technical Note and Review of the Literature

Transjugular intrahepatic portosystemic shunt (TIPS) dysfunction is an important problem after creation of shunts. Most commonly, TIPS recanalization is performed via the jugular vein approach. Occasionally it is difficult to cross the occlusion. We describe a hybrid technique for TIPS revision via a direct transhepatic access combined with a transjugular approach. In two cases, bare metal stents or polytetrafluoroethylene (PTFE)-covered stent grafts had been placed in TIPS tract previously, and they were completely obstructed. The tracts were inaccessible via the jugular vein route alone. In each case, after fluoroscopy or computed tomography-guided transhepatic puncture of the stented segment of the TIPS, a wire was threaded through the shunt and snared into the right jugular vein. The TIPS was revised by balloon angioplasty and additional in-stent placement of PTFE-covered stent grafts. The patients were discharged without any complications. Doppler sonography 6 weeks after TIPS revision confirmed patency in the TIPS tract and the disappearance of ascites. We conclude that this technique is feasible and useful, even in patients with previous PTFE-covered stent graft placement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Venous Access Ports: Indications, Implantation Technique, Follow-Up, and Complications

The subcutaneous venous access device (SVAD or 'port') is a critical component in the care of patients with chronic disease. The modern SVAD provides reliable access for blood withdrawal and medication administration with minimal disruption to a patient's lifestyle. Because of improved materials and catheter technology, today's ports are lighter and stronger and capable of high-pressure injections of contrast for cross-sectional imaging. The majority of SVAD placement occurs in interventional radiology departments due to their ability to provide this service at lower costs, lower, complication rates, and greater volumes. Port-insertion techniques vary depending on the operator, but all consist of catheter placement in the central venous circulation followed by subcutaneous pocket creation and port attachment to the catheter with fixation and closure of the pocket. Venous access challenges occasionally occur in patients with central vein occlusions, necessitating catheterization of collateral veins or port placement in alternate locations. Complications of SVADs include those associated with the procedure as well as short- (<30 days) and long-term problems. Procedural and early complications are quite rare due to the near-universal use of real-time ultrasound guidance for vein puncture, but they can include hematoma, catheter malposition, arrhythmias, and pneumothorax. Late problems include both thrombotic complications (native venous or port-catheter thrombosis) and infections (tunnel or pocket infections or catheter-associated bloodstream infections). Most guidelines suggest that 0.3 infections/1000 catheter days is an appropriate upper threshold for the insertion of SVADs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Veno-Occlusive Behcet's Disease

Purpose: To retrospectively evaluate the outcome of endovascular treatments for patients with chronic veno-occlusive disease in different vascular beds secondary to Behcet's disease (BD). There are few case reports on the subject, and this is the largest study to date. Materials and Methods: From January 2001 through October 2009, chronic venous occlusions were treated in 10 patients (all male [age range 18-76 years]) with BD using percutaneous transluminal angioplasty and/or stent placement. All patients were symptomatic and had chronic iliofemoral deep venous thrombosis (DVT; n = 5), central venous occlusion (n = 3), or Budd-Chiari syndrome (BCS; n = 2). All patients met criteria of the International Study Group on Behcet's Disease. Results: Two of five patients with DVT had unsuccessful recanalization attempts. Three patients had successful recanalization with stent placement. All three veins were occluded within 1 month with unsuccessful reinterventions. Three patients with chronic central venous occlusion had successful recanalization with percutaneous transluminal angioplasty (n = 1) and stent placement (n = 2). Two patients had reocclusion with successful reintervention. Two BCS patients had successful treatment with stent placements. Overall technical success was 69%, and no procedural complications were encountered. None of the patients with chronic DVT had patent veins; however, all patients with central venous occlusion or BCS had patent veins on color Doppler ultrasonography at follow-up ranging from 3 to 48 months after intervention. Conclusion: Endovenous treatment for chronic iliofemoral DVT due to BD had a poor outcome. However, long-term outcome after endovenous treatment for upper-extremity central venous occlusion and BCS syndrome was good.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interventional Radiological Treatment of Perihepatic Vascular Stenosis or Occlusion in Pediatric Patients After Liver Transplantation

Purpose: Evaluation of the efficacy and safety of percutaneous treatment of vascular stenoses and occlusions in pediatric liver transplant recipients. Methods: Fifteen children (mean age 8.3 years) underwent interventional procedures for 18 vascular complications after liver transplantation. Patients had stenoses or occlusions of portal veins (n = 8), hepatic veins (n = 3), inferior vena cava (IVC; n = 2) or hepatic arteries (n = 5). Technical and clinical success rates were evaluated. Results: Stent angioplasty was performed in seven cases (portal vein, hepatic artery and IVC), and sole balloon angioplasty was performed in eight cases. One child underwent thrombolysis (hepatic artery). Clinical and technical success was achieved in 14 of 18 cases of vascular stenoses or occlusions (mean follow-up 710 days). Conclusion: Pediatric interventional radiology allows effective and safe treatment of vascular stenoses after pediatric liver transplantation (PLT). Individualized treatment with special concepts for each pediatric patient is necessary. The variety, the characteristics, and the individuality of interventional management of all kinds of possible vascular stenoses or occlusions after PLT are shown.

62 RADIOLOGY AND NUCLEAR MEDICINE↗