Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VAPORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

GEOS Constituent Data Assimilation Beyond Aura MLS: Assimilating NASA SAGE III/ISS Profiles of Stratospheric Water Vapor

Ozone and water vapor in the lower stratosphere are important trace gases for atmospheric chemistry and radiative budget. The Stratospheric Aerosol and Gas Experiment (SAGE) missions have been crucial in monitoring the stratospheric ozone loss and the subsequent recovery as well as the trends in water vapor linked to surface temperature trends. The SAGE III instrument aboard the International Space Station (ISS) continues the SAGE mission record, with high vertical resolution profiles of ozone and water vapor available since mid 2017. The NASA GEOS Earth system model has the new capability to assimilate multi-constituents from ground and space-based instruments using the GEOS Constituent Data Assimilation System (CoDAS). The recently released MERRA-2 Stratospheric Composition Reanalysis with Aura MLS (M2-SCREAM) assimilates version 4.2 MLS ozone, water vapor and other chemically-reactive species with the NASA GEOS model coupled to a stratospheric-only chemistry mechanism and transport constrained to the MERRA-2 reanalysis. While the number of solar occultation observations a day from SAGE III/ISS is about 1% of the total number of profiles observed globally by MLS, the chemical timescales of ozone and water vapor in the lower stratosphere are long enough that the SAGE III/ISS data may provide a useful constraint on the assimilated product. Using the same GEOS CoDAS configuration as M2-SCREAM, we will present a series of experiments to investigate if water vapor trends are consistent with the assimilation of SAGE observations with and without Aura retrievals, and to determine if the assimilation of SAGE observations produces a steady product for trend analysis, especially as the end of the Aura mission nears. In our experiments, assimilating only SAGE III/ISS water vapor profiles results in water vapor fields more consistent with experiments that assimilate MLS v5; however, in the polar regions SAGE III/ISS observations are not available and the modelled values are unconstrained. We are encouraged by the positive benefit assimilating the less frequent SAGE III/ISS observations has on stratospheric composition. Sensitivity experiments such as these will allow us to assess the added value of SAGE data for continued monitoring of the stratospheric composition for climate and ozone recovery assessments.

K Emma Knowland↗

Coalescence-controlled and coalescence-free growth regimes during deposition of pulsed metal vapor fluxes on insulating surfaces

The morphology and physical properties of thin films deposited by vapor condensation on solid surfaces are predominantly set by the processes of island nucleation, growth, and coalescence. When deposition is performed using pulsed vapor fluxes, three distinct nucleation regimes are known to exist depending on the temporal profile of the flux. These regimes can be accessed by tuning deposition conditions; however, their effect on film microstructure becomes marginal when coalescence sets in and erases morphological features obtained during nucleation. By preventing coalescence from being completed, these nucleation regimes can be used to control microstructure evolution and thus access a larger palette of film morphological features. Recently, we derived the quantitative criterion to stop coalescence during continuous metal vapor flux deposition on insulating surfaces—which typically yields 3-dimensional growth—by describing analytically the competition between island growth by atomic incorporation and the coalescence rate of islands [Lü et al., Appl. Phys. Lett. 105, 163107 (2014)]. Here, we develop the analytical framework for entering a coalescence-free growth regime for metal vapor deposition on insulating substrates using pulsed vapor fluxes, showing that there exist three distinct criteria for suppressing coalescence that correspond to the three nucleation regimes of pulsed vapor flux deposition. The theoretical framework developed herein is substantiated by kinetic Monte Carlo growth simulations. Our findings highlight the possibility of using atomistic nucleation theory for pulsed vapor deposition to control morphology of thin films beyond the point of island density saturation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correction Technique for Raman Water Vapor Lidar Signal-Dependent Bias and Suitability for Water Wapor Trend Monitoring in the Upper Troposphere

The MOHAVE-2009 campaign brought together diverse instrumentation for measuring atmospheric water vapor. We report on the participation of the ALVICE (Atmospheric Laboratory for Validation, Interagency Collaboration and Education) mobile laboratory in the MOHAVE-2009 campaign. In appendices we also report on the performance of the corrected Vaisala RS92 radiosonde measurements during the campaign, on a new radiosonde based calibration algorithm that reduces the influence of atmospheric variability on the derived calibration constant, and on other results of the ALVICE deployment. The MOHAVE-2009 campaign permitted the Raman lidar systems participating to discover and address measurement biases in the upper troposphere and lower stratosphere. The ALVICE lidar system was found to possess a wet bias which was attributed to fluorescence of insect material that was deposited on the telescope early in the mission. Other sources of wet biases are discussed and data from other Raman lidar systems are investigated, revealing that wet biases in upper tropospheric (UT) and lower stratospheric (LS) water vapor measurements appear to be quite common in Raman lidar systems. Lower stratospheric climatology of water vapor is investigated both as a means to check for the existence of these wet biases in Raman lidar data and as a source of correction for the bias. A correction technique is derived and applied to the ALVICE lidar water vapor profiles. Good agreement is found between corrected ALVICE lidar measurments and those of RS92, frost point hygrometer and total column water. The correction is offered as a general method to both quality control Raman water vapor lidar data and to correct those data that have signal-dependent bias. The influence of the correction is shown to be small at regions in the upper troposphere where recent work indicates detection of trends in atmospheric water vapor may be most robust. The correction shown here holds promise for permitting useful upper tropospheric water vapor profiles to be consistently measured by Raman lidar within NDACC (Network for the Detection of Atmospheric Composition Change) and elsewhere, despite the prevalence of instrumental and atmospheric effects that can contaminate the very low signal to noise measurements in the UT.

MOHAVE-2009↗

Redefining fuel heating value for engines: Accounting for heat of vaporization

Defining a fuel's heating value (i.e., energy content) is fundamental for calculating engine efficiency and for life cycle analysis comparisons between different fuels. Traditional definitions of lower heating value and higher heating value account for the effect of water vapor versus liquid water in the exhaust, which is important when the fuel is used in a furnace or boiler. In an engine, it is equally important to properly account for the energy required to vaporize liquid fuel. Heat of vaporization has a small effect for common hydrocarbon fuels, typically less than 1% of lower heating value, but the effect is much larger for other important fuels such as ethanol (3.4% of lower heating value) and methanol (5.9% of lower heating value). This paper defines a new type of fuel heating value that more accurately reflects the useful fuel energy content for engines. Vaporized heating value is defined as the heating value when starting with a vaporized fuel instead of a liquid fuel. It can be calculated by adding the fuel's heat of vaporization to the traditional lower heating value. This paper illustrates the rationale and benefits of using vaporized heating value using data from the literature.

09 BIOMASS FUELS↗

The vapor pressures of explosives

The vapor pressures of many explosive compounds are extremely low and thus determining accurate values proves difficult. Many researchers, using a variety of methods, have measured and reported the vapor pressures of explosives compounds at single temperatures, or as a function of temperature using vapor pressure equations. There are large variations in reported vapor pressures for many of these compounds, and some errors exist within individual papers. This article provides a review of explosive vapor pressures and describes the methods used to determine them. We have compiled primary vapor pressure relationships traceable to the original citations and include the temperature ranges for which they have been determined. Corrected values are reported as needed and described in the text. In addition, after critically examining the available data, we calculate and tabulate vapor pressures at 25 °C.

explosive, vapor pressure, NG, TNT, PETN, RDX↗

Variability of Water Vapor in the Tropical Middle Atmosphere Observed From Satellites and Interpreted Using SD-WACCM Simulations

Water vapor in the middle atmosphere plays an essential role in global warming, ozone depletion, and the formation of polar stratospheric and mesospheric clouds. We show that tropical middle atmospheric water vapor simulated with the specified-dynamics version of the Whole Atmosphere Community Climate Model (SD-WACCM) is consistent with changes observed in a merged satellite data set, which encompasses the period 1993–2020. Consistent with previous work, we find no significant trend in the stratosphere in either the observations or the simulation; in the mesosphere, we find a long-term trend of 0.1 ppmv per decade, but only in the observations. We also analyze an SD-WACCM simulation for the longer period 1980–2019 to quantify the contribution of various factors to the decadal variation of middle atmospheric water vapor. Over 1980–1995, the simulated water vapor in the upper stratosphere and mesosphere, averaged zonally and over ±30° latitude, increases by 0.30 ppmv per decade due to increasing methane emissions. After 1995, a significant abrupt decrease of water vapor of 0.37 ppmv per decade and then a gradual increase of 0.33 ppmv per decade result from changes in stratospheric cold point temperature. The cold-point temperature is strongly influenced by the strength of the Brewer-Dobson circulation. The acceleration of the Brewer-Dobson circulation before about 2003 leads to a cooler tropical tropopause and a decrease of water vapor, and the deceleration thereafter leads to corresponding warming of the tropopause and an increase in water vapor.

54 ENVIRONMENTAL SCIENCES↗

A simplified lithium vapor box divertor

A detached divertor plasma is predicted to be necessary to mitigate the heat fluxes and ion energy, and so sputtering, at the divertor plate of a fusion power plant. It has proven difficult in current experiments, however, to prevent the detachment front, once formed, from running up to the main plasma resulting in deterioration of pedestal performance. The lithium vapor box divertor localizes a dense cloud of lithium vapor away from the main plasma, in order to induce detachment at a stable, distant location. The vapor localization is created by local evaporation and nearby condensation, a configuration inaccessible for non-condensing seed impurities. This paper provides simulations of lithium vapor flow using the SPARTA direct simulation Monte Carlo (DSMC) code, in which the lithium vapor dynamics are governed by Li–Li collisions that should dominate in regions with little plasma. Inertia is included in this code, permitting the formation of shocks. The plasma model implemented in SPARTA is based on UEDGE results for the location of ionization and recombination. We find that a simplified lithium vapor box configuration, without baffles, provides robust stabilization of the detachment front and acceptable lithium vapor flow to the main chamber. Lithium is evaporated from a capillary porous surface on the private-flux side of the divertor, distant from the main plasma, and is condensed on the other side walls of the divertor chamber. The condensed lithium flows back to the evaporator through 2 cm internal diameter pipes. The capillary pressure differential at the surface of the evaporator is capable of overcoming MHD back-force in the piping, with a great deal of margin if a sandwich flow channel insert is implemented. Very little lithium should be accumulated on the first wall of the main chamber if it is maintained at 600 °C, as expected for a power-producing fusion system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of Water Vapor Measurements by Airborne Sun Photometer and Diode Laser Hygrometer on the NASA DC-8

In January-February 2003 the 14-channel NASA Ames Airborne Tracking Sunphotometer 30 (AATS) and the NASA Langley/Ames Diode Laser Hygrometer (DLH) were flown on the NASA DC-8 aircraft. AATS measured column water vapor on the aircraft-to-sun path, while DLH measured local water vapor in the free stream between the aircraft fuselage and an outboard engine cowling. The AATS and DLH measurements were compared for two DC-8 vertical profiles by differentiating the AATS column measurement and/or integrating the DLH local measurement over the altitude range of each profile (7.7-10 km and 1.2-12.5 km). These comparisons extend, for the first time, tests of AATS water vapor retrievals to altitudes >~6 km and column contents <0.1 g cm-2. To our knowledge this is the first time suborbital spectroscopic water vapor measurements using the 940-nm band have been tested in conditions so high and dry. For both profiles layer water vapor (LWV) from AATS and DLH were highly correlated, with r2 0.998, rms difference 7.2% and bias (AATS minus DLH) 0.9%. For water vapor densities AATS and DLH had r2 0.968, rms difference 27.6%, and bias (AATS minus DLH) -4.2%. These results compare favorably with previous comparisons of AATS water vapor to in situ results for altitudes <~6 km, columns ~0.1 to 5 g cm-2 and densities ~0.1 to 17 g m-3.

47 OTHER INSTRUMENTATION↗

Water vapor isotopic composition during TRACER IOP

The TRACER-Iso project took place from June 1 to September 30, 2022 as part of the intensive observation period (IOP) of the Tracking Aerosol Convection Interactions (TRACER) project at the main project site at the La Porte, Texas, municipal airport. The project sought to use measurements of the stable isotopic composition of water vapor to better understand cloud-aerosol interactions in deep convection in a polluted urban setting. Water vapor isotopologue and humidity measurements were determined using a Picarro L2130 Water Vapor Isotope Analyzer. The instrument was deployed in the guest van and consists of three main components: a water vapor isotope analyzer, and a Los Gatos Research Water Vapor Isotope Standard Source (WVISS), and a Los Gatos Research Dry Air Source. Ambient air samples were collected through an inlet located about one meter above roof of the shipping container. Samples were then delivered to the analyzer through teflon tubing by use of an external pump to minimize the transport time between the inlet and analyzer. The inlet tubing was surrounded by a Briskheat heat trace and insulating material to ensure ambient air samples did not fall below the dew point and result in condensation. The analyzer uses cavity ringdown spectroscopy to report isotopic ratios of ambient air samples at a frequency of 1 Hz. The calibration unit of the instrument was used in conjunction with the dry air source to periodically measure the δ values of standard waters. It uses a nebulizer to push small water droplets into a hot chamber that vaporizes the water without fractionation. This vapor was then transported to the analyzer using a built-in compressor and the dry air source, which allows each standard with known δ values to be measured at a wide range of humidity values for post-measurement calibration of ambient air samples. There are multiple sources of uncertainty introduced at different stages during the data collection and processing. These include (1) instrument precision, (2) uncertainty in the secondary standards, (3) humidity-correction uncertainty, and (4) VSMOW-SLAP calibration uncertainty. Uncertainty from each step is propagated in quadrature to calculate a total uncertainty of each isotopologue. Uncertainty was determined to be 2.3‰ for δD and 0.4‰ for δ18O.

54 ENVIRONMENTAL SCIENCES↗

Heats of vaporization of room temperature ionic liquids by tunable vacuum ultraviolet photoionization

The heats of vaporization of the room temperature ionic liquids (RTILs) N-butyl-N-methylpyrrolidinium bistrifluorosulfonylimide, N-butyl-N-methylpyrrolidinium dicyanamide, and 1-butyl-3-methylimidazolium dicyanamide are determined using a heated effusive vapor source in conjunction with single photon ionization by a tunable vacuum ultraviolet synchrotron source. The relative gas phase ionic liquid vapor densities in the effusive beam are monitored by clearly distinguished dissociative photoionization processes via a time-of-flight mass spectrometer at a tunable vacuum ultraviolet beamline 9.0.2.3 (Chemical Dynamics Beamline) at the Advanced Light Source synchrotron facility. Resulting in relatively few assumptions, through the analysis of both parent cations and fragment cations, the heat of vaporization of N-butyl-N-methylpyrrolidinium bistrifluorosulfonylimide is determined to be Delta Hvap(298.15 K) = 195+-19 kJ mol-1. The observed heats of vaporization of 1-butyl-3-methylimidazolium dicyanamide (Delta Hvap(298.15 K) = 174+-12 kJ mol-1) and N-butyl-N-methylpyrrolidinium dicyanamide (Delta Hvap(298.15 K) = 171+-12 kJ mol-1) are consistent with reported experimental values using electron impact ionization. The tunable vacuum ultraviolet source has enabled accurate measurement of photoion appearance energies. These appearance energies are in good agreement with MP2 calculations for dissociative photoionization of the ion pair. These experimental heats of vaporization, photoion appearance energies, and ab initio calculations corroborate vaporization of these RTILs as intact cation-anion ion pairs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Retrieval of water vapor column abundance and aerosol properties from ChemCam passive sky spectroscopy

In this work, we derive water vapor column abundances and aerosol properties from Mars Science Laboratory (MSL) ChemCam passive mode observations of scattered sky light. This paper covers the methodology and initial results for water vapor and also provides preliminary results for aerosols. The data set presented here includes the results of 113 observations spanning from Mars Year 31 L s = 291° (March 30, 2013) to Mars Year 33 L s = 127° (March 24, 2016). Each ChemCam passive sky observation acquires spectra at two different elevation angles. We fit these spectra with a discrete-ordinates multiple scattering radiative transfer model, using the correlated-k approximation for gas absorption bands. The retrieval proceeds by first fitting the continuum of the ratio of the two elevation angles to solve for aerosol properties, and then fitting the continuum-removed ratio to solve for gas abundances. The final step of the retrieval makes use of the observed CO 2 absorptions and the known CO 2 abundance to correct the retrieved water vapor abundance for the effects of the vertical distribution of scattering aerosols and to derive an aerosol scale height parameter. Our water vapor results give water vapor column abundance with a precision of ±0.6 precipitable microns and systematic errors no larger than ±0.3 precipitable microns, assuming uniform vertical mixing. The ChemCam-retrieved water abundances show, with only a few exceptions, the same seasonal behavior and the same timing of seasonal minima and maxima as the TES, CRISM, and REMS-H data sets that we compare them to. However ChemCam-retrieved water abundances are generally lower than zonal and regional scale from-orbit water vapor data, while at the same time being significantly larger than pre-dawn REMS-H abundances. Pending further analysis of REMS-H volume mixing ratio uncertainties, the differences between ChemCam and REMS-H pre-dawn mixing ratios appear to be much too large to be explained by large scale circulations and thus they tend to support the hypothesis of substantial diurnal interactions of water vapor with the surface. Our preliminary aerosol results, meanwhile, show the expected seasonal pattern in dust particle size but also indicate a surprising interannual increase in water–ice cloud opacities.

79 ASTRONOMY AND ASTROPHYSICS↗

Growth behavior of LiMn{sub 2}O{sub 4} particles formed by solid-state reactions in air and water vapor

Morphology control of particles formed during conventional solid-state reactions without any additives is a challenging task. Here, we propose a new strategy to control the morphology of LiMn{sub 2}O{sub 4} particles based on water vapor-induced growth of particles during solid-state reactions. We have investigated the synthesis and microstructural evolution of LiMn{sub 2}O{sub 4} particles in air and water vapor atmospheres as model reactions; LiMn{sub 2}O{sub 4} is used as a low-cost cathode material for lithium-ion batteries. By using spherical MnCO{sub 3} precursor impregnated with LiOH, LiMn{sub 2}O{sub 4} spheres with a hollow structure were obtained in air, while angulated particles with micrometer sizes were formed in water vapor. The pore structure of the particles synthesized in water vapor was found to be affected at temperatures below 700 °C. We also show that the solid-state reaction in water vapor is a simple and valuable method for the large-scale production of particles, where the shape, size, and microstructure can be controlled. - Graphical abstract: This study has demonstrated a new strategy towards achieving morphology control without the use of additives during conventional solid-state reactions by exploiting water vapor-induced particle growth. - Highlights: • A new strategy to control the morphology of LiMn{sub 2}O{sub 4} particles is proposed. • Water vapor-induced particle growth is exploited in solid-state reactions. • The microstructural evolution of LiMn{sub 2}O{sub 4} particles is investigated. • The shape, size and microstructure can be controlled by solid-state reactions.

36 MATERIALS SCIENCE↗

Marine Boundary Layer Decoupling and the Stable Isotopic Composition of Water Vapor

Decoupling of the subcloud layer in stratocumulus-topped marine boundary layers (STMBL) influences low-cloud cover by limiting the supply of water vapor from the surface. However, the relative importance of mixing between surface fluxes and other reservoirs of water vapor as a function of the degree of decoupling is poorly understood. Water vapor transport within the STMBL and its response to decoupling is explored using surface measurements of water vapor isotopic composition that were obtained from Graciosa Island, Azores, during the summer and fall of 2018. The data show an inverse relationship between the decoupling metric, Δq, and the degree of drying from an isotopically depleted water vapor source. The isotopic data require some degree of drying with an isotopically depleted source for coupled conditions, and likely require a small amount of mixing even for strongly decoupled conditions. The data are consistent with mixing between purely local reservoirs of water vapor, subjected to a small amount of condensation and fractionation, and do not require the invocation of large-scale transport of water vapor aloft or additional cloud-formation effects aloft.

54 ENVIRONMENTAL SCIENCES↗

Molecular dynamics study on condensation/evaporation coefficients of chain molecules at liquid–vapor interface

The structure and thermodynamic properties of the liquid–vapor interface are of fundamental interest for numerous technological implications. For simple molecules, e.g., argon and water, the molecular condensation/evaporation behavior depends strongly on their translational motion and the system temperature. Existing molecular dynamics (MD) results are consistent with the theoretical predictions based on the assumption that the liquid and vapor states in the vicinity of the liquid–vapor interface are isotropic. Additionally, similar molecular condensation/evaporation characteristics have been found for long-chain molecules, e.g., dodecane. It is unclear, however, whether the isotropic assumption is valid and whether the molecular orientation or the chain length of the molecules affects the condensation/evaporation behavior at the liquid–vapor interface. In this study, MD simulations were performed to study the molecular condensation/evaporation behavior of the straight-chain alkanes, i.e., butane, octane, and dodecane, at the liquid–vapor interface, and the effects of the molecular orientation and chain length were investigated in equilibrium systems. The results showed that the condensation/evaporation behavior of chain molecules primarily depends on the molecular translational energy and the surface temperature and is independent of the molecular chain length. Furthermore, the orientation at the liquid–vapor interface was disordered when the surface temperature was sufficiently higher than the triple point and had no significant effect on the molecular condensation/evaporation behavior. The validity of the isotropic assumption was confirmed, and we conclude that the condensation/evaporation coefficients can be predicted by the liquid-to-vapor translational length ratio, even for chain molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The lithium vapor box divertor

It has long been recognized that volumetric dissipation of the plasma heat flux from a fusion power system is preferable to its localized impingement on a material surface. Volumetric dissipation mitigates both the anticipated very high heat flux and intense particle-induced damage due to sputtering. Our recent projections to a tokamak demonstration power plant suggest an immense upstream parallel heat flux, of order 20 GW m -2 , implying that fully detached operation may be a requirement for the success of fusion power. Building on pioneering work on the use of lithium by Nagayama et al and by Ono et al as well as earlier work on the gas box divertor by Watkins and Rebut, we present here a concept for a lithium vapor box divertor, in which lithium vapor extracts momentum and energy from a fusion-power-plant divertor plasma, using fully volumetric processes. Furthermore, at the high powers and pressures that are projected this requires a high density of lithium vapor, which must be isolated from the main plasma in order to avoid lithium build-up on the chamber walls or in the plasma. Isolation is achieved through a powerful multi-box differential pumping scheme available only for condensable vapors. The preliminary box-wise calculations are encouraging, but much more work is required in order to demonstrate the practical viability of this scheme, taking into account at least 2D plasma and vapor flows within and between the vapor boxes and out of the vapor boxes to the main plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Final work plan : supplemental upward vapor intrusion investigation at the former CCC/USDA grain storage facility in Hanover, Kansas.

The Commodity Credit Corporation (CCC), an agency of the U.S. Department of Agriculture (USDA), operated a grain storage facility at the northeastern edge of the city of Hanover, Kansas, from 1950 until the early 1970s. During this time, commercial grain fumigants containing carbon tetrachloride were in common use by the grain storage industry to preserve grain in their facilities. In February 1998, trace to low levels of carbon tetrachloride (below the maximum contaminant level [MCL] of 5.0 {micro}g/L) were detected in two private wells near the former grain storage facility at Hanover, as part of a statewide USDA private well sampling program that was implemented by the Kansas Department of Health and Environment (KDHE) near former CCC/USDA facilities. In 2007, the CCC/USDA conducted near-surface soil sampling at 61 locations and also sampled indoor air at nine residences on or adjacent to its former Hanover facility to address the residents concerns regarding vapor intrusion. Low levels of carbon tetrachloride were detected at four of the nine homes. The results were submitted to the KDHE in October 2007 (Argonne 2007). On the basis of the results, the KDHE requested sub-slab sampling and/or indoor air sampling (KDHE 2007). This Work Plan describes, in detail, the proposed additional scope of work requested by the KDHE and has been developed as a supplement to the comprehensive site investigation work plan that is pending (Argonne 2008). Indoor air samples collected previously from four homes at Hanover were shown to contain the carbon tetrachloride at low concentrations (Table 2.1). It cannot be concluded from these previous data that the source of the detected carbon tetrachloride is vapor intrusion attributable to former grain storage operations of the CCC/USDA at Hanover. The technical objective of the vapor intrusion investigation described here is to assess the risk to human health due to the potential for upward migration of carbon tetrachloride and chloroform into four homes located on or adjacent to the former CCC/USDA facility. The technical objective will be accomplished by collecting sub-slab vapor samples. The preliminary data collected during the July 2007 investigation did not fully address the source of or migration pathway for the carbon tetrachloride detected in the four homes. The scope of work proposed here will generate additional data needed to help evaluate whether the source of the detected carbon tetrachloride is vapor intrusion attributable to activities of the CCC/USDA. The additional vapor sampling at Hanover will be performed, on behalf of the CCC/USDA, by the Environmental Science Division of Argonne National Laboratory and H&P Mobile Geochemistry of San Diego (http://www.handpmg.com). Argonne is a nonprofit, multidisciplinary research center operated by UChicago Argonne, LLC, for the U.S. Department of Energy (DOE). The CCC/USDA has entered into an interagency agreement with DOE, under which Argonne provides technical assistance to the CCC/USDA with environmental site characterization and remediation at its former grain storage facilities. The professional staff members of H&P Mobile Geochemistry are nationally leading experts in soil gas sampling and vapor intrusion investigations.

54 ENVIRONMENTAL SCIENCES↗

Chemical Species in the Vapor Phase of Hanford Double-Shell Tanks: Potential Impacts on Waste Tank Corrosion Processes

The presence of corrosive and inhibiting chemicals on the tank walls in the vapor space, arising from the waste supernatant, dictate the type and degree of corrosion that occurs there. An understanding of how waste chemicals are transported to the walls and the affect on vapor species from changing supernatant chemistry (e.g., pH, etc.), are basic to the evaluation of risks and impacts of waste changes on vapor space corrosion (VSC). In order to address these issues the expert panel workshop on double-shell tank (DST) vapor space corrosion testing (RPP-RPT-31129) participants made several recommendations on the future data and modeling needs in the area of DST corrosion. In particular, the drying of vapor phase condensates or supernatants can form salt or other deposits at the carbon steel interface resulting in a chemical composition at the near surface substantially different from that observed directly in the condensates or the supernatants. As a result, over the past three years chemical modeling and experimental studies have been performed on DST supernatants and condensates to predict the changes in chemical composition that might occur as condensates or supernatants equilibrate with the vapor space species and dry at the carbon steel surface. The experimental studies included research on both the chemical changes that occurred as the supernatants dried as well as research on how these chemical changes impact the corrosion of tank steels. The chemical modeling and associated experimental studies were performed at the Pacific Northwest National Laboratory (PNNL) and the research on tank steel corrosion at the Savannah River National Laboratory (SRNL). This report presents a summary of the research conducted at PNNL with special emphasis on the most recent studies conducted in FY10. An overall summary of the project results as well as their broader implications for vapor space corrosion of the DST’s is given at the end of this report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of particle and vapor wall-loss effects on controlled wood-smoke smog-chamber experiments

Here, smog chambers are extensively used to study processes that drive gas and particle evolution in the atmosphere. A limitation of these experiments is that particles and gas-phase species may be lost to chamber walls on shorter timescales than the timescales of the atmospheric processes being studied in the chamber experiments. These particle and vapor wall losses have been investigated in recent studies of secondary organic aerosol (SOA) formation, but they have not been systematically investigated in experiments of primary emissions from combustion. The semi-volatile nature of combustion emissions (e.g. from wood smoke) may complicate the behavior of particle and vapor wall deposition in the chamber over the course of the experiments due to the competition between gas/particle and gas/wall partitioning. Losses of vapors to the walls may impact particle evaporation in these experiments, and potential precursors for SOA formation from combustion may be lost to the walls, causing underestimations of aerosol yields. Here, we conduct simulations to determine how particle and gas-phase wall losses contributed to the observed evolution of the aerosol during experiments in the third Fire Lab At Missoula Experiment (FLAME III). We use the TwO-Moment Aerosol Sectional (TOMAS) microphysics algorithm coupled with the organic volatility basis set (VBS) and wall-loss formulations to examine the predicted extent of particle and vapor wall losses. We limit the scope of our study to the dark periods in the chamber before photo-oxidation to simplify the aerosol system for this initial study. Our model simulations suggest that over one-third of the initial particle-phase organic mass (41 %) was lost during the experiments, and over half of this particle-organic mass loss was from direct particle wall loss (65 % of the loss) with the remainder from evaporation of the particles driven by vapor losses to the walls (35 % of the loss). We perform a series of sensitivity tests to understand uncertainties in our simulations. Uncertainty in the initial wood-smoke volatility distribution contributes 18 % uncertainty to the final particle-organic mass remaining in the chamber (relative to base-assumption simulation). We show that the total mass loss may depend on the effective saturation concentration of vapor with respect to the walls as these values currently vary widely in the literature. The details of smoke dilution during the filling of smog chambers may influence the mass loss to the walls, and a dilution of ~ 25:1 during the experiments increased particle-organic mass loss by 33 % compared to a simulation where we assume the particles and vapors are initially in equilibrium in the chamber. Finally, we discuss how our findings may influence interpretations of emission factors and SOA production in wood-smoke smog-chamber experiments.

54 ENVIRONMENTAL SCIENCES↗