Composite fan exit guide vanes for high bypass ratio gas turbine engines

Various composite materials were identified for reduced weight applications as fan exit guide vanes in high bypass ratio gas turbine engines. Candidate materials, airfoil geometry and ply orientation were evaluated using NASTRAN finite element analysis. A vane core and shell design approach utilizing several different fiber orientation concepts was selected and variations in bending and torsional stiffness were documented. Material suppliers and airfoil fabricators were selected to provide panels and airfoils which were inspected, environmentally conditioned and tested. Static and dynamic airfoil tests established durability characteristics for a range of composite material/design approaches.

Blecherman, S. S.↗

Laser anemometer measurements in an annular cascade of core turbine vanes and comparison with theory

Laser measurements were made in an annular cascade of stator vanes operating at an exit critical velocity ratio of 0.78. Velocity and flow angles in the blade to blade plane were obtained at every 10 percent of axial chord within the passage and at 1/2 axial chord downstream of the vanes for radial positions near the hub, mean and tip. Results are presented in both plot and tabulated form and are compared with calculations from an inviscid, quasi three dimensional computer program. The experimental measurements generally agreed well with these theoretical calculations, an indication of the usefulness of this analytic approach.

Goldman, L. J.↗

Thermal and flow analysis of a convection, air-cooled ceramic coated porous metal concept for turbine vanes

Analysis was made of the heat transfer and pressure drop through turbine vanes made of a sintered, porous metal coated with a thin layer of ceramic and convection cooled by spanwise flow of cooling air. The analysis was made to determine the feasibility of using this concept for cooling very small turbines, primarily for short duration applications such as in missile engines. The analysis was made for gas conditions of approximately 10 and 40 atm and 1644 K and with turbine vanes made of felt-type porous metals with relative densities from 0.2 and 0.6 and ceramic coating thicknesses of 0.076 to 0.254 mm.

Stepka, F. S.↗

The performance of an annular vane swirler

In connection with the desirability of optimizing the design of a gas turbine combustion chamber, there exists a need for a more complete understanding of the fluid dynamics of the flow in such chambers. In order to satisfy this need, experimental and theoretical research is being conducted with the objective to study two-dimensional axisymmetric geometries under low speed, nonreacting, turbulent, swirling flow conditions. The flow enters the test section and proceeds into a larger chamber. Inlet swirl vanes are adjustable to a variety of vane angles. The present investigation concentrates on the time-mean flow characteristics which are generated by the upstream annular swirler. The investigation makes use of a five-hole pitot probe technique. A theoretical analysis of swirl numbers associated with several idealized exit velocity profiles is included, and values of the ratio of maximum swirl velocity to maximum axial velocity at different swirl strengths are given for each case.

Lilley, D. G.↗

Design and performance of a fixed, nonaccelerating, guide vane cascade that operates over an inlet flow angle range of 60 deg

A unique set of wind tunnel guide vanes are designed with an inverse design code and analyzed with a panel method and an integral boundary layer code developed at the NASA Lewis Research Center. The fixed guide vanes, 80 feet long with 6-foot chord length, were designed for the NASA Ames 40 x 80/80 x 120 ft Wind Tunnel. Low subsonic flow is accepted over a 60 deg range of inlet angle from either the 40 x 80 leg or the 80 x 120 leg of the wind tunnel, and directed axially into the main leg of the tunnel where drive fans are located. Experimental tests of 1/10-scale models were conducted to verify design calculations.

Sanz, J. M.↗

Design and performance of a fixed, nonaccelerating guide vane cascade that operates over an inlet flow angle range of 60 deg

A unique set of wind tunnel guide vanes are designed with an inverse design code and analyzed with a panel method and an integral boundary layer code developed at the NASA Lewis Research Center. The fixed guide vanes, 80 feet long with 6-foot chord length, were designed for the NASA Ames 40 x 80/80 x 120 ft Wind Tunnel. Low subsonic flow is accepted over a 60 deg range of inlet angle from either the 40 x 80 leg or the 80 x 120 leg of the wind tunnel, and directed axially into the main leg of the tunnel where drive fans are located. Experimental tests of 1/10-scale models were conducted to verify design calculations.

Sanz, J. M.↗

Reduction of background noise induced by wind tunnel jet exit vanes

The NASA-Langley 4 x 7 m wind tunnel develops low frequency flow pulsations at certain velocity ranges during open throat mode operation, affecting the aerodynamics of the flow and degrading the resulting model test data. Triangular vanes attached to the trailing edge of flat steel rails, mounted 10 cm from the inside of the jet exit walls, have been used to reduce this effect; attention is presently given to methods used to reduce the inherent noise generation of the vanes while retaining their pulsation reduction features.

Martin, R. M.↗

Turbine Vane External Heat Transfer. Volume 1: Analytical and Experimental Evaluation of Surface Heat Transfer Distributions with Leading Edge Showerhead Film Cooling

Progress in predictive design capabilities for external heat transfer to turbine vanes was summarized. A two dimensional linear cascade (previously used to obtain vane surface heat transfer distributions on nonfilm cooled airfoils) was used to examine the effect of leading edge shower head film cooling on downstream heat transfer. The data were used to develop and evaluate analytical models. Modifications to the two dimensional boundary layer model are described. The results were used to formulate and test an effective viscosity model capable of predicting heat transfer phenomena downstream of the leading edge film cooling array on both the suction and pressure surfaces, with and without mass injection.

Turner, E. R.↗

The noncavitating performance and life of a small vane-type positive displacement pump in liquid hydrogen

The low flow rate and high head rise requirements of hydrogen/oxygen auxiliary propulsion systems make the application of centrifugal pumps difficult. Positive displacement pumps are well-suited for these flow conditions, but little is known about their performance and life characteristics in liquid hydrogen. An experimental and analytical investigation was conducted to determine the performance and life characteristics of a vane-type, positive displacement pump. In the experimental part of this effort, mass flow rate and shaft torque were determined as functions of shaft speed and pump pressure rise. Since liquid hydrogen offers little lubrication in a rubbing situation, pump life is an issue. During the life test, the pump was operated intermittently for 10 hr at the steady-state point of 0.074 lbm/sec (0.03 kg/sec) flow rate, 3000 psid (2.07 MPa) pressure rise, and 8000 rpm (838 rad/sec) shaft speed. Pump performance was monitored during the life test series and the results indicated no loss in performance. Material loss from the vanes was recorded and wear of the other components was documented. In the analytical part of this effort, a comprehensive pump performance analysis computer code, developed in-house, was used to predict pump performance. The results of the experimental investigation are presented and compared with the results of the analysis. Results of the life test are also presented.

Ulbricht, T. E.↗

Effect of port corner geometry on the internal performance of a rotating-vane-type thrust reverser

An investigation has been conducted in the static-test facility of the Langley 16-Foot Transonic Tunnel to determine the effects of reverser port geometry on the internal performance of a nonaxisymmetric rotating-vane-type thrust reverser. Thrust reverser vane positions representing a spoiled-trust (partially deployed) position and a full-reverse-thrust (fully deployed) position were tested with each port geometry variable. The effects of upstream port corner radius and wall angle on internal performance were determined. In addition, the effect of the length of a simulated cooling liner (blunt-base step) near the reverser port entrance was investigated; five different lengths were tested. All tests were conducted with no external flows, and nozzle pressure ratio was varied from 1.2 to 5.0.

Berrier, B. L.↗

The noncavitating performance and life of a small vane-type positive displacement pump in liquid hydrogen

The low flow rate and high head rise requirements of hydrogen/oxygen auxiliary propulsion systems make the application of centrifugal pumps difficult. Positive displacement pumps are well-suited for these flow conditions, but little is known about their performance and life characteristics in liquid hydrogen. An experimental and analytical investigation was conducted to determine the performance and life characteristics of a vane-type, positive displacement pump. In the experimental part of this effort, mass flow rate and shaft torque were determined as functions of shaft speed and pump pressure rise. Since liquid hydrogen offers little lubrication in a rubbing situation, pump life is an issue. During the life test, the pump was operated intermittently for 10 hr at the steady-state point of 0.074 lbm/sec (0.03 kg/sec) flow rate, 3000 psid (2.07 MPa) pressure rise, and 9000 rpm (938 rad/sec) shaft speed. Pump performance was monitored during the life test series and the results indicated no loss in performance. Material loss from the vanes was recorded and wear of the other components was documented. In the analytical part of this effort, a comprehensive pump performance analysis computer code, developed in-house, was used to predict pump performance. The results of the experimental investigation are presented and compared with the results of the analysis. Results of the life test are also presented.

Ulbricht, T. E.↗

Effects of the installation and operation of jet-exhaust yaw vanes on the longitudinal and lateral-directional characteristics of the F-14 airplane

A wind tunnel investigation was conducted in the Langley 16-Foot Transonic Tunnel to determine the effects of the installation and use of jet exhaust yaw vanes on the longitudinal and lateral-directional characteristics of the F-14 aircraft. The model was tested at Mach numbers from 0.70 to 1.25 at angles of attack from 0 deg to 4.3 deg. Compressed air was used to simulate nozzle exhaust flow from jet off up to a nozzle pressure ratio of 8. The results of the investigation show that the yaw vanes can augment the rudders to provide directional control, but further investigation will be necessary to optimize the deflection schedule associated with the various nozzle power settings.

Reubush, David E.↗

A free-trailing vane flow direction indicator employing a linear output Hall effect transducer

The Hall effect vane (HEV) was developed to measure flow angularity in the NASA 40-by-80-foot and 80-by-120-foot wind tunnels. This indicator is capable of sensing flow direction at air speeds from 5 to 300 knots and over a + or - 40 deg angle range with a resolution of 0.1 deg. A free-trailing vane configuration employing a linear output Hall effect transducer as a shaft angle resolver was used. The current configuration of the HEV is designed primarily for wind tunnel calibration testing; however, other potential applications include atmospheric, flight or ground research testing. The HEV met initial design requirements.

Zell, Peter T.↗

An experimental study of turbine vane heat transfer with leading edge and downstream film cooling

This paper presents the effects of downstream film cooling, with and without leading edge showerhead film cooling, on turbine-vane external heat transfer. Steady-state experimental measurements were made in a three-vane linear two-dimensional cascade. The principal independent parameters were maintained over ranges consistent with actual engine conditions. The test matrix was structured to provide an assessment of the independent influence of parameters of interest, namely, exit Mach number, exit Reynolds number, coolant-to-gas temperature ratio, and coolant-to-gas pressure ratio. The data obtained indicate that considerable cooling benefits can be achieved by utilizing downstream film cooling. The downstream film cooling process was shown to be a complex interaction of two competing mechanisms. The thermal dilution effect, associated with the injection of relatively cold fluid, results in a decrease in the heat transfer to the airfoil. Conversely, the turbulence augmentation, produced by the injection process, results in increased heat transfer to the airfoil.

Nirmalan, V.↗

Aircraft ground test and subscale model results of axial thrust loss caused by thrust vectoring using turning vanes

The NASA-Dryden F/A-18 high alpha research vehicle was modified to incorporate three independently controlled turning vanes located aft of the primary nozzle of each engine to vector thrust for pitch and yaw control. Ground measured axial thrust losses were compared with the results from a 14.25 pct. cold jet model for single and dual vanes inserted up to 25 degs into the engine exhaust. Data are presented for nozzle pressure ratios of 2.0 and 3.0 and nozzle exit areas of 253 and 348 sq in. The results indicate that subscale nozzle test results properly predict trends but underpredict the full scale results by approx. 1 to 4.5 pct. in thrust loss.

Johnson, Steven A.↗

Comparative Performance of a Powerplus Vane-type Supercharger and an N.A.C.A. Roots-type Supercharger

This report presents the results of tests of a Power plus supercharger and a comparison of its performance with the performance previously obtained with an N.A.C.A. Roots-type supercharger. The Powerplus supercharger is a positive displacement blower of the vane type having mechanically operated vanes, the movement of which is controlled by slots and eccentrics. The supercharger was tested at a range of pressure differences from 0 to 15 inches of mercury and at speeds from 500 to 2,500 r.p.m. The pressure difference across the supercharger was obtained by throttling the intake of a depression tank which was interposed in the air duct between the supercharger and the Durley orifice box used for measuring the air. The results of these tests show that at low pressure differences and at all speeds the power required by the Powerplus supercharger to compress a definite quantity of air per second is considerably higher than that required by the Roots. At pressure differences from 10 to 14 inches of mercury and at speeds over 2,000 r.p.m. the power requirements of the two superchargers are practically the same. At a pressure difference of 15 inches of mercury or greater and at a speed of 2,500 r.p.m. or greater the performance of the Powerplus supercharger is slightly better than that of the Roots. Because the Powerplus supercharger cannot be operated at a speed greater than 3,000 r.p.m. as compared with 7,000 r.p.m. for the Roots, its capacity is approximately one-half that of the Roots for the same bulk. The Powerplus supercharger is more complicated and less reliable than the Roots supercharger.

Schey, Oscar W↗

Secondary flows in annular cascades and effects on flow in inlet guide vanes

Qualitative discussion is presented of the general nature of secondary flows in stationary annular cascades with thin wall boundary layers and radial design variation of circulation. Deviations from ideal mean outlet flows (based on blade-element performance) exist in potential-flow region of vanes because of conditions imposed by end-wall boundaries, displacement of wall boundary layers toward blade suction surfaces, and irrotationality requirement. As a consequence of existence of nonuniform radial flow across blade spacing, it may not generally be possible to obtain an arbitrarily specified design variation of the turning angle along the radial height of a blade row. Quantitative turning angle corrections due to effects of secondary flows in axial-flow compressor inlet guide vanes were obtained from induced deflections of a superimposed vortex system in conjunction with an empirically determined correlation factor.

CASCADES, EXPERIMENT↗

Effect of variable-position inlet guide vanes and interstage bleed on compressor performance of a high-pressure-ratio turbojet engine

Increased guide-vane turning resulted in poorer overall performance, the decrease being greatest at the highest rotor speed. Rotating stall originating at the tips of the first stage correlated with the knee in the stall-limit line. Increasing guide-vane turning shifted the first-stage stall-free performance and the knee in the stall-limit line to a lower engine speed. Opening the interstage bleed reduced the minimum rotor speed at which stall-free performance of the first stage was possible and tended to eliminate the knee in the stall-limit line.

Huntley, S C↗