Development of respiration-rate transducers for aircraft environments
Development and evaluation of respiration rate transducers for aircraft environments
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Development and evaluation of respiration rate transducers for aircraft environments
Environment and function testing of pressure transducer used for hydraulic accumulator pressure indicator
Rectangular to cylindrical waveguide transducer which couples dominant rectangular and cylindrical transverse electromagnetic modes
Silicon semiconductor combustion pressure transducer for high temperature HF pressure measurements within liquid rocket motor chambers
Piezoelectric pressure transducer, discussing design, material used and performance
Temperature gradient and thermal effects on ceramic transducer sensors used on spacecraft for cosmic dust experiments
A series of displacement transducers have been demonstrated which are based on the detection of electrons that quantum-mechanically tunnel across a narrow gap between electrodes.
The task of my two-months internship was to test different materials to be used to build an high temperature transducer, to develop some prototypes and to test their performance, to assess the reliability of commercial product rated for such a temperature, as well as to collaborate in developing the signal processing code to measure the condensed water levels.
Transducing materials are being used in many aspects of our daily life serving as actuators, sensors, displays, communications and other components of commercial mechanisms. At JPL, such materials are being used to enable novel space and terrestrial applications. This effort involves mostly the use of piezoelectric, electroactive polymers (EAP), and shape memory alloys (SMA). The piezoelectric based devices and mechanisms that were developed include ultrasonic motors, piezopump, ultrasonic/sonic drilledcorer (USDC), and ferrosource. Further, the electroactive polymers were used to demonstrate a gripper, wiper, lifter and haptic interfaces. The research and develop tasks consists of analytical modeling, experimental corroboration, material characterization as well as devices and mechanisms design, construction and demonstration.
Exercise provides a robust physiological stimulus that evokes cross-talk between a wide range of tissues via hormonal, cellular and molecular signals that when repeated regularly over time (i.e., training) improves physiological capacity, benefits numerous organ systems and decreases the risk for premature mortality. In spite of its fundamental importance, a gap remains in identifying the detailed molecular signals and responses to exercise and its benefits for health and disease prevention. To further knowledge in this emerging area, the Molecular Transducers of Physical Activity Consortium (MoTrPAC) was established to generate a molecular map of the effects of acute and chronic exercise. MoTrPAC investigators are conducting preclinical and clinical studies to better understand the systemic effects of exercise across multiple tissues. The preclinical studies were performed on more than 700 rats with the analysis of twenty or more organs per rat. The clinical study involves a large cohort of ~2600 individuals with a range of ages and fitness levels (untrained, trained, highly trained) who will be evaluated physiologically and by molecular probing of blood, muscle and adipose tissues before and after acute and chronic endurance or resistance exercise. Multi-omic analyses (genomics, epigenomics, transcriptomics, proteomics and metabolomics/lipidomics) will be performed followed by state-of-the-art bioinformatics to create a molecular map of exercise. This mapping project will provide a public database that is expected to enhance our understanding of the health benefits of physical activity in many organ systems and potentially provide insight into mitigating diseases through activity.
UV/vis absorption spectroscopy affords indirect structural information about the photochemistry and photophysics of molecules by inferring types of electronic transitions from spectral features. Direct structural information would become available, though, if light-induced crystal structures could be mapped against changes in optical absorption spectra as a photochemical process evolves. We present a series of light-induced crystal structures that track real-time changes in solid-state optical absorption spectra of a crystalline nanooptomechanical transducer, while the transduction process unfolds within its crystal lattice at 100 K. Results afford a combined structural and spectral mapping of its solid-state optical absorption, from which the operational mechanism of nanooptomechanical transduction is revealed. Metal-to-ligand and metal-centered charge-transfer bands are assigned to optical absorption peaks directly from their 3-D light-induced crystal structures. This approach could be used to characterize many solid-state optoelectronic materials.
In this study, the Raman biaxial stress coefficients K II and strain-free phonon frequencies ω 0 have been determined for the E 2 (low), E 2 (high), and A 1 (LO) phonon modes of aluminum nitride, AlN, using both experimental and theoretical approaches. The E 2 (high) mode of AlN is recommended for the residual stress analysis of AlN due to its high sensitivity and the largest signal-to-noise ratio among the studied modes. The E 2 (high) Raman biaxial stress coefficient of ₋3.8 cm₋1/GPa and strain-free phonon frequency of 656.68 cm ₋1 were then applied to perform both macroscopic and microscopic stress mappings. For macroscopic stress evaluation, the spatial variation of residual stress was measured across an AlN-on-Si wafer prepared by sputter deposition. A cross-wafer variation in residual stress of ~150 MPa was observed regardless of the average stress state of the film. Microscopic stress evaluation was performed on AlN piezoelectric micromachined ultrasonic transducers (pMUTs) with submicrometer spatial resolution. These measurements were used to assess the effect of device fabrication on residual stress distribution in an individual pMUT and the effect of residual stress on the resonance frequency. At ~20 μm directly outside the outer edge of the pMUT electrode, a large lateral spatial variation in residual stress of ~100 MPa was measured, highlighting the impact of metallization structures on residual stress in the AlN film.
While regular physical activity is a cornerstone of health, wellness, and vitality, the impact of endurance exercise training on molecular signaling within and across tissues remains to be delineated. The Molecular Transducers of Physical Activity Consortium (MoTrPAC) was established to characterize molecular networks underlying the adaptive response to exercise. Here, we describe the endurance exercise training studies undertaken by the Preclinical Animal Sites Studies component of MoTrPAC, in which we sought to develop and implement a standardized endurance exercise protocol in a large cohort of rats. To this end, Adult (6-mo) and Aged (18-mo) female (n = 151) and male (n = 143) Fischer 344 rats were subjected to progressive treadmill training (5 d/wk, ~70%–75% VO 2 max) for 1, 2, 4, or 8 wk; sedentary rats were studied as the control group. A total of 18 solid tissues, as well as blood, plasma, and feces, were collected to establish a publicly accessible biorepository and for extensive omics-based analyses by MoTrPAC. Treadmill training was highly effective, with robust improvements in skeletal muscle citrate synthase activity in as little as 1–2 wk and improvements in maximum run speed and maximal oxygen uptake by 4–8 wk. For body mass and composition, notable age- and sex-dependent responses were observed. This work in mature, treadmill-trained rats represents the most comprehensive and publicly accessible tissue biorepository, to date, and provides an unprecedented resource for studying temporal-, sex-, and age-specific responses to endurance exercise training in a preclinical rat model.
We propose the use of the Earth as a transducer for ultralight dark-matter detection. In particular, we point out a novel signal of kinetically mixed dark-photon dark matter: a monochromatic oscillating magnetic field generated at the surface of the Earth. Similar to the signal in a laboratory experiment in a shielded box (or cavity), this signal arises because the lower atmosphere is a low-conductivity air gap sandwiched between the highly conductive interior of the Earth below and ionosphere or interplanetary medium above. At low masses (frequencies) the signal in a laboratory detector is usually suppressed by the size of the detector multiplied by the dark-matter mass. Crucially, in our case the suppression is by the radius of the Earth, and not by the (much smaller) height of the atmosphere. We compute the size and global vectorial pattern of our magnetic field signal, which enables sensitive searches for this signal using unshielded magnetometers dispersed over the surface of the Earth. In principle, the signal we compute exists for any dark photon in the mass range 10 –21 eV ≲ m A' ≲ 3 × 10 –14 eV . We summarize the results of our companion paper [M. A. Fedderke et al., Search for dark-photon dark matter in the SuperMAG geomagnetic field dataset, arXiv:2108.08852], in which we detail such a search using a publicly available dataset from the SuperMAG Collaboration: we report no robust signal candidates and so place constraints in the (more limited) dark-photon dark-matter mass range 2 × 10 –18 eV ≲ m A' ≲ 7 × 10 –17 eV (corresponding to frequencies 6 × 10 –4 Hz ≲ f ≲ 2 × 10 –2 Hz). These constraints are complementary to existing astrophysical bounds. Future searches for this signal may improve the sensitivity over a wide range of ultralight dark-matter candidates and masses.
Coherent microwave-optical photon conversion is a key enabling technology for the Quantum Internet, since it allows entanglement distribution among superconducting-based network nodes. A high-efficiency electro-optic transducer based on three-dimensional superconducting radio-frequency (SRF) technology has recently been proposed at Fermilab. In this paper, we evaluate the impact of Fermilab's transduction hardware on the entanglement generation probability and the entanglement rate, which are two critical metrics from a communication engineering perspective. Furthermore, we provide some guidelines to increase the direct entanglement rate, i.e., the rate before any entanglement purification process. Our analysis shows that, through high-efficiency transduction, it is possible to reduce the network overhead. This preliminary work paves the way toward distantly interconnected superconducting quantum processors.
We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. We have developed an initial design for proof-of-principle testing of the flow sensor performance in microwave K-band. A cylindrical resonator prototype was fabricated from brass for initial tests in water. The cavity size is matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed, consisting of a piping Tee with bulkhead WR-42 microwave waveguide installed in leak-proof design. In the test article, the cylindrical cavity is positioned in the center of the pipe. A microwave waveguide circulator was installed in the setup to suppress microwave reflections at the cavity entrance. Preliminary spectral characterization of cavity spectral response was performed with microwave VNA. Applying mechanical pressure to cavity membrane showed a measurable shift in the microwave resonant frequency. We also investigate mechanical integrity of the flowmeter’s membrane through computer simulations. By calculating the stress on the plate due to deflection and, comparing the stress to the material ultimate tensile strength and yield strength, it can be estimated if the plate will fail. The stress on the plate was calculated with an analytic closed form solution model, and with COMSOL Structural Mechanics Module which does not involve any approximations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure.
The Department of Energy’s Advanced Sensors and Instrumentation program seeks to develop and qualify advanced sensors for the nuclear industry. Reliable high temperature and high radiation sensors for detection and characterization of structural flaws in pipes, vessels, and structurally critical components is a weakness for both conventional light water reactors with coolant T-hot approaching 350oC, and for advanced reactors with T-hot temperatures in excess of 500 to 800oC. Magnetostrictive Electromagnetic Acoustic Transducers using a cold spray cobalt coating have been proposed as a sensor design that can withstand these kinds of temperatures and radiation levels to serve as online sensors to detect flaws before cracks, pits, or erosion/corrosion flaws progress to through-wall failures. This report tests cold spray cobalt as part of a magnetostrictive EMAT for high temperature service. Cobalt is known to have strong magnetostrictive properties however the effect of cold spray application is not well studied. This program was surprised to discover that cold sprayed cobalt exhibited little or no magnetostrictive behavior until it was thermally annealed. Following annealing to 650oC however, cold spray cobalt did exhibit a magnetostrictive response. Work to date prior to this milestone report publication showed that magnetostrictive EMAT was successfully tested to 400oC with an alnico permanent magnet. The program plans to extend testing with an electromagnet to higher temperatures. This follow-on work will be reported under subsequent publications or as a revision to this report.
Tubular structures are critical components in infrastructure such as power plants. Throughout their life, they are subjected to extreme conditions or suffer from defects such as corrosion and cracks. Although regular inspection of these components is necessary, such inspection is limited by safety-related risks and limited access for human inspection. Robots can provide a solution for automatic inspection. The main challenge, however, lies in integrating sensors for nondestructive evaluation with robotic platforms. As part of developing a versatile lizard-inspired tube inspector robot, in this study the authors propose to integrate electromagnetic acoustic transducers into a modular robotic gripper for use in automated ultrasonic inspection. In particular, spiral coils with cylindrical magnets are integrated into a novel friction-based gripper to excite Lamb waves in thin cylindrical structures. To evaluate the performance of the integrated sensors, the gripper was attached to a robotic arm manipulator and tested on pipes of different outer diameters. Two sets of tests were carried out on both defect-free pipes and pipes with simulated defects, including surface partial cracking and corrosion. The inspection results indicated that transmitted and received signals could be acquired with an acceptable signal-to-noise ratio in the time domain. Moreover, the simulated defects could be successfully detected using the integrated robotic sensing system.