Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tracking Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

BEAM ACCELERATION BY A MULTICELL RF CAVITY STRUCTURE PROPOSED FOR AN IMPROVED YIELD IN HYDROFORMING

We study the accelerating properties of a new multicell cavity structure with irises forming a rectangular aperture between the cavity cells. We are interested in this structure because, from a mechanical point of view, it may be possible to manufacture with high quality using a hydroforming process. RF analysis shows that the rectangular iris shape provides some asymmetric transverse focusing per half RF period, particularly for low beam energies. If the horizontal and vertical rectangular irises are interleaved, the net transverse focusing could be increased. Here we present studies of the acceleration and transport properties of these cavities by tracking particles using the ORBIT Code through time-dependent 3D cavity fields taken from CST MWS.

43 PARTICLE ACCELERATORS↗

The impact of absorption coefficient on polarimetric determination of Berry phase based depth resolved characterization of biomedical scattering samples: a polarized Monte Carlo investigation

The modulation of the state of polarization of photons due to scatter generates associated geometric phase that is being investigated as a means for decreasing the degree of uncertainty in back-projecting the paths traversed by photons detected in backscattered geometry. In our previous work, we established that polarimetrically detected Berry phase correlates with the mean photon penetration depth of the backscattered photons collected for image formation. In this work, we report on the impact of state-of-linear-polarization (SOLP) filtering on both the magnitude and population distributions of image forming detected photons as a function of the absorption coefficient of the scattering sample. The results, based on Berry phase tracking implemented Polarized Monte Carlo Code, indicate that sample absorption plays a significant role in the mean depth attained by the image forming backscattered detected photons.

backscattered Mueller matrix↗

Microwave Instability Simulations for NSLS-II

Potential-well distortion and the microwave instability in the NSLS-II storage ring are investigated. The longitudinal wakepotential is calculated as a sum of the contributions due to vacuum chamber components distributed around the ring. An approximation to the wakepotential for a 0.05-mm charge distribution length, much shorter than the 4.5-mm length of the unperturbed circulating bunch, is used as a pseudo-Green's function for beam dynamics simulations. Comparison of particle tracking simulations using the TRANFT code with the Haissinski solution shows good agreement below the instability threshold current. Above threshold two regimes are observed: (1) energy spread and bunch length are time-dependent (saw tooth behavior); (2) both are time-independent.

43 PARTICLE ACCELERATORS↗

Improving the Field Portability of Neutron and Gamma Counting Techniques

Savannah River National Laboratory (SRNL) puts science to work by developing techniques that better meet customers needs for in-situ measurements. There is high demand for laboratory quality measurements in field situations, improving the cost and speed for first responders and environmental monitoring. This work focused on two improvements (1) reading a signal from a neutron detector using a Raspberry Pi (2) testing the Peak-to-Valley method for determining the depth of a source in soil contamination measurements. A Raspberry Pi is a cheap, compact computer. This affordable, compact computer is able to do simple tasks that a desktop computer is able to do, like spreadsheets, browse the internet, play games and even program a simple robot. Additionally, a Raspberry Pi can run off of a battery, so it could be deployed for long term measurements in adverse conditions like neutron monitors deployed in a shipping port. Using the Raspberry Pi and libraries easily accessible on the internet, a code was written in Python that allows the Pi to keep track of how many times a button is pushed. This work will be used with the future goal of creating low power-budget neutron detectors. 1) Make sure Python was correctly installed on the Raspberry Pi. 2) Write a code that will keep track of how many times a button connected to the Pi is pressed. A code was written to use the Raspberry Pi to count the number of times the button was pushed. Moving forward the Raspberry Pi will be tested with a neutron counter. Ideally, each signal from the neutron pulse will be equivalent of 'push the button' and be counted. In the characterization of a soil contamination area both the location and the depth of the source is important. Attenuation of the source by the soil can make determining its depth challenging, particularly for monoenergetic radionuclides like Cs-137. To address this issue, a method of calculating the 'peak-to-valley' ratio of the gamma count spectra is implemented to help calculate the known depth of the source. 1) Determine the 'peak-to-valley' ratio of a Cs-137 source at different depths. 2) Find an appropriate function to serve as a model for the peak-to-valley ratio as a function of depth. Several Petri dishes, filled with sand, were stacked with one containing a Cs-137 source. The individual Petri dishes allowed for the source to be placed at different depths. A bucket was placed over the sand and source, to keep the detector at a consistent height. A Petri dish containing a Eu-155 source, which acted as an internal calibration standard, was placed on top of the bucket. A NaI detector was place on top of the Eu-155 source and the assembly was surrounded by a tungsten shield. Count times were 20 minutes and the data was analyzed using PeakEasy. Data was recorded for Cs-137 at a series of depths in sand. Both exponential and logarithmic functions provided a reasonable fit to the data. The experimental data showed a decreasing 'peak-to-valley' ratio as the depth was increased. The next steps for this project involves determining the optimum fit function and combining the results from sand to different soil types to get a better representation of the soil found at SRS. Eventually, the peak-to-valley ratio will be used to estimate the depth of contamination in field measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Teaching Software Sustainability for High Performance Computing at ATPESC

The Argonne Training Program in Extreme Scale Computing (ATPESC) was started by Argonne National Laboratory with the objective of expanding the ranks of better-prepared users of high-performance computing (HPC) machines. One of the unique aspects of the program was inclusion of a track on software engineering and community codes. The inclusion was motivated by the observation that the projects with good software processes were better able to meet their scientific goals. Over the years, with greater awareness of software sustainability issues in the community, the track has evolved into a software productivity and sustainability track. In this paper we present our experience in choosing and disseminating the content related to the topic of software engineering in high performance computing science from the beginning of the program until now. We discuss the motivations and the reception of the tracks. We also document the evolution of the track over the years based on student feedback and also the growth of awareness about software productivity in high performance computing.

Dubey, Anshu↗

Prototype Distributed Ledger Technology of UF 6 Cylinder Tracking in Ethereum

We have created a demonstration permissioned Distributed Ledger Technology (DLT) datastore for the UF 6 cylinder tracking safeguards use-case utilizing the Ethereum DLT framework and using Solidity for smart contract code. Our demonstration creates a simulated dataset representing tracking of 75,000 UF 6 cylinders across 11 example nuclear facilities worldwide. Our DLT system allows for easy input and reading of shipping and receiving data, including a Graphical User Interface (GUI). Sandia’s Emulytics capability was leveraged to help create the DLT node network and assess performance. We find that our DLT prototype can easily handle to ~150,000 UF 6 cylinder shipments per year worldwide, without any excessive computational or storage burden on the IAEA or Member States. Next steps could include a demonstration to the IAEA and potentially demonstrating integration with TradeLens, a DLT in use by a consortium of international shipping companies representing over half of world shipping trade.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Graphics processing unit accelerated three-dimensional model for the simulation of pulsed low-temperature plasmas

A 3-dimensional particle-in-cell/Monte Carlo collision simulation that is fully implemented on a graphics processing unit (GPU) is described and used to determine low-temperature plasma characteristics at high reduced electric field, E/n, in nitrogen gas. Details of implementation on the GPU using the NVIDIA Compute Unified Device Architecture framework are discussed with respect to efficient code execution. The software is capable of tracking around 10 × 10{sup 6} particles with dynamic weighting and a total mesh size larger than 10{sup 8} cells. Verification of the simulation is performed by comparing the electron energy distribution function and plasma transport parameters to known Boltzmann Equation (BE) solvers. Under the assumption of a uniform electric field and neglecting the build-up of positive ion space charge, the simulation agrees well with the BE solvers. The model is utilized to calculate plasma characteristics of a pulsed, parallel plate discharge. A photoionization model provides the simulation with additional electrons after the initial seeded electron density has drifted towards the anode. Comparison of the performance benefits between the GPU-implementation versus a CPU-implementation is considered, and a speed-up factor of 13 for a 3D relaxation Poisson solver is obtained. Furthermore, a factor 60 speed-up is realized for parallelization of the electron processes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neural Algorithms for Low Power Implementation of Partial Differential Equations

The rise of low-power neuromorphic hardware has the potential to change high-performance computing; however much of the focus on brain-inspired hardware has been on machine learning applications. A low-power solution for solving partial differential equations could radically change how we approach large-scale computing in the future. The random walk is a fundamental stochastic process that underlies many numerical tasks in scientific computing applications. We consider here two neural algorithms that can be used to efficiently implement random walks on spiking neuromorphic hardware. The first method tracks the positions of individual walkers independently by using a modular code inspired by grid cells in the brain. The second method tracks the densities of random walkers at each spatial location directly. We present the scaling complexity of each of these methods and illustrate their ability to model random walkers under different probabilistic conditions. Finally, we present implementations of these algorithms on neuromorphic hardware.

97 MATHEMATICS AND COMPUTING↗

WE-H-BRA-08: A Monte Carlo Cell Nucleus Model for Assessing Cell Survival Probability Based On Particle Track Structure Analysis

Purpose: To correlate the damage produced by particles of different types and qualities to cell survival on the basis of nanodosimetric analysis and advanced DNA structures in the cell nucleus. Methods: A Monte Carlo code was developed to simulate subnuclear DNA chromatin fibers (CFs) of 30nm utilizing a mean-free-path approach common to radiation transport. The cell nucleus was modeled as a spherical region containing 6000 chromatin-dense domains (CDs) of 400nm diameter, with additional CFs modeled in a sparser interchromatin region. The Geant4-DNA code was utilized to produce a particle track database representing various particles at different energies and dose quantities. These tracks were used to stochastically position the DNA structures based on their mean free path to interaction with CFs. Excitation and ionization events intersecting CFs were analyzed using the DBSCAN clustering algorithm for assessment of the likelihood of producing DSBs. Simulated DSBs were then assessed based on their proximity to one another for a probability of inducing cell death. Results: Variations in energy deposition to chromatin fibers match expectations based on differences in particle track structure. The quality of damage to CFs based on different particle types indicate more severe damage by high-LET radiation than low-LET radiation of identical particles. In addition, the model indicates more severe damage by protons than of alpha particles of same LET, which is consistent with differences in their track structure. Cell survival curves have been produced showing the L-Q behavior of sparsely ionizing radiation. Conclusion: Initial results indicate the feasibility of producing cell survival curves based on the Monte Carlo cell nucleus method. Accurate correlation between simulated DNA damage to cell survival on the basis of nanodosimetric analysis can provide insight into the biological responses to various radiation types. Current efforts are directed at producing cell survival curves for high-LET radiation.

60 APPLIED LIFE SCIENCES↗

Nuclear signal simulation applied to gas ionizing chambers

Particle transport codes used in detector simulation allow the calculation of the energy deposited by charged particles produced following an interaction. The pulses temporal shaping is more and more used in nuclear measurement into pulse shape analysis techniques. A model is proposed in this paper to simulate the pulse temporal shaping and the associated noise level thanks to the output track file PTRAC provides by Monte-Carlo particle transport codes. The model has been dedicated to ion chambers and more especially for High Pressure Xenon chambers HPXe where the pulse shape analysis can resolve some issues regarding with this technology as the ballistic deficit phenomenon. The model is fully described and an example is presented as a validation of such full detector simulation. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-scale approach to the modeling of fission gas discharge during hypothetical loss-of-flow accident in gen-IV sodium fast reactor

The required technological and safety standards for future Gen IV Reactors can only be achieved if advanced simulation capabilities become available, which combine high performance computing with the necessary level of modeling detail and high accuracy of predictions. The purpose of this paper is to present new results of multi-scale three-dimensional (3D) simulations of the inter-related phenomena, which occur as a result of fuel element heat-up and cladding failure, including the injection of a jet of gaseous fission products into a partially blocked Sodium Fast Reactor (SFR) coolant channel, and gas/molten sodium transport along the coolant channels. The computational approach to the analysis of the overall accident scenario is based on using two different inter-communicating computational multiphase fluid dynamics (CMFD) codes: a CFD code, PHASTA, and a RANS code, NPHASE-CMFD. Using the geometry and time history of cladding failure and the gas injection rate, direct numerical simulations (DNS), combined with the Level Set method, of two-phase turbulent flow have been performed by the PHASTA code. The model allows one to track the evolution of gas/liquid interfaces at a centimeter scale. The simulated phenomena include the formation and breakup of the jet of fission products injected into the liquid sodium coolant. The PHASTA outflow has been averaged over time to obtain mean phasic velocities and volumetric concentrations, as well as the liquid turbulent kinetic energy and turbulence dissipation rate, all of which have served as the input to the core-scale simulations using the NPHASE-CMFD code. A sliding window time averaging has been used to capture mean flow parameters for transient cases. The results presented in the paper include testing and validation of the proposed models, as well the predictions of fission-gas/liquid-sodium transport along a multi-rod fuel assembly of SFR during a partial loss-of-flow accident. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Boron-10 Lined Proportional Counter Model Validation

The decreasing supply of 3He is stimulating a search for alternative neutron detectors; one potential 3He replacement is 10B-lined proportional counters. Simulations are being performed to predict the performance of systems designed with 10B-lined tubes. Boron-10-lined tubes are challenging to model accurately because the neutron capture material is not the same as the signal generating material. Thus, to simulate the efficiency, the neutron capture reaction products that escape the lining and enter the signal generating fill gas must be tracked. The tube lining thickness and composition are typically proprietary vendor information, and therefore add additional variables to the system simulation. The modeling methodologies used to predict the neutron detection efficiency of 10B-lined proportional counters were validated by comparing simulated to measured results. The measurements were made with a 252Cf source positioned at several distances from a moderated 2.54-cm diameter 10B-lined tube. Models were constructed of the experimental configurations using the Monte Carlo transport code MCNPX, which is capable of tracking the reaction products from the (n,10B) reaction. Several different lining thicknesses and compositions were simulated for comparison with the measured data. This paper presents the results of the evaluation of the experimental and simulated data, and a summary of how the different linings affect the performance of a coincidence counter configuration designed with 10B-lined proportional counters.

Lintereur, Azaree T.↗

Recent Improvements to CHEF, a Framework for Accelerator Computations

CHEF is body of software dedicated to accelerator related computations. It consists of a hierarchical set of libraries and a stand-alone application based on the latter. The implementation language is C++; the code makes extensive use of templates and modern idioms such as iterators, smart pointers and generalized function objects. CHEF has been described in a few contributions at previous conferences. In this paper, we provide an overview and discuss recent improvements. Formally, CHEF refers to two distinct but related things: (1) a set of class libraries; and (2) a stand-alone application based on these libraries. The application makes use of and exposes a subset of the capabilities provided by the libraries. CHEF has its ancestry in efforts started in the early nineties. At that time, A. Dragt, E. Forest [2] and others showed that ring dynamics can be formulated in a way that puts maps rather than Hamiltonians, into a central role. Automatic differentiation (AD) techniques, which were just coming of age, were a natural fit in a context where maps are represented by their Taylor approximations. The initial vision, which CHEF carried over, was to develop a code that (1) concurrently supports conventional tracking, linear and non-linear map-based techniques (2) avoids 'hardwired' approximations that are not under user control (3) provides building blocks for applications. C++ was adopted as the implementation language because of its comprehensive support for operator overloading and the equal status it confers to built-in and user-defined data types. It should be mentioned that acceptance of AD techniques in accelerator science owes much to the pioneering work of Berz [1] who implemented--in fortran--the first production quality AD engine (the foundation for the code COSY). Nowadays other engines are available, but few are native C++ implementations. Although AD engines and map based techniques are making their way into more traditional codes e.g. [5], it is also probably fair to say that map-oriented codes are still perceived as a specialized niche.

43 PARTICLE ACCELERATORS↗

Analysis of the track- and dose-averaged LET and LET spectra in proton therapy using the GEANT4 Monte Carlo code

Purpose: The motivation of this study was to find and eliminate the cause of errors in dose-averaged linear energy transfer (LET) calculations from therapeutic protons in small targets, such as biological cell layers, calculated using the GEANT 4 Monte Carlo code. Furthermore, the purpose was also to provide a recommendation to select an appropriate LET quantity from GEANT 4 simulations to correlate with biological effectiveness of therapeutic protons. Methods: The authors developed a particle tracking step based strategy to calculate the average LET quantities (track-averaged LET, LET{sub t} and dose-averaged LET, LET{sub d}) using GEANT 4 for different tracking step size limits. A step size limit refers to the maximally allowable tracking step length. The authors investigated how the tracking step size limit influenced the calculated LET{sub t} and LET{sub d} of protons with six different step limits ranging from 1 to 500 μm in a water phantom irradiated by a 79.7-MeV clinical proton beam. In addition, the authors analyzed the detailed stochastic energy deposition information including fluence spectra and dose spectra of the energy-deposition-per-step of protons. As a reference, the authors also calculated the averaged LET and analyzed the LET spectra combining the Monte Carlo method and the deterministic method. Relative biological effectiveness (RBE) calculations were performed to illustrate the impact of different LET calculation methods on the RBE-weighted dose. Results: Simulation results showed that the step limit effect was small for LET{sub t} but significant for LET{sub d}. This resulted from differences in the energy-deposition-per-step between the fluence spectra and dose spectra at different depths in the phantom. Using the Monte Carlo particle tracking method in GEANT 4 can result in incorrect LET{sub d} calculation results in the dose plateau region for small step limits. The erroneous LET{sub d} results can be attributed to the algorithm to determine fluctuations in energy deposition along the tracking step in GEANT 4. The incorrect LET{sub d} values lead to substantial differences in the calculated RBE. Conclusions: When the GEANT 4 particle tracking method is used to calculate the average LET values within targets with a small step limit, such as smaller than 500 μm, the authors recommend the use of LET{sub t} in the dose plateau region and LET{sub d} around the Bragg peak. For a large step limit, i.e., 500 μm, LET{sub d} is recommended along the whole Bragg curve. The transition point depends on beam parameters and can be found by determining the location where the gradient of the ratio of LET{sub d} and LET{sub t} becomes positive.

60 APPLIED LIFE SCIENCES↗

The History of MCNP and about 20 Related Programs

The history of the MCNP code is a long and complicated one that touches a huge number of other software packages over the decades. This document will attempt to place the direct lineage of the MCNP code into a single document and track the people who worked on and around the software. This report is necessarily incomplete. The author only has access to the LANL archives, which have gaps in key areas. Speculation will be used to fill gaps where necessary. It is hoped that future revisions will have more detail than this report, especially as others come forward with their knowledge. The history will be broken into a few segments. Sec. 1 will go through the low-energy history from MCS to MCNP version 4. In Sec. 2, the history of high-energy physics from Oak Ridge’s NTC to MCNP version 6 will be discussed. Sec. 3 will go through some important notes to complete this history. Finally, Sec. 4 contains a chart of the lineage of the code.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-570: New Quality Assurance Method Using Motion Tracking for 6D Robotic Couches

Purpose: To accommodate geometrically accurate patient positioning, a robotic couch that is capable of 6-degrees of freedom has been introduced. However, conventional couch QA methods are not sufficient to enable the necessary accuracy of tests. Therefore, we have developed a camera based motion detection and geometry calibration system for couch QA. Methods: Employing a Visual-Tracking System (VTS, BonitaB10, Vicon, UK) which tracks infrared reflective(IR) markers, camera calibration was conducted using a 5.7 × 5.7 × 5.7 cm{sup 3} cube attached with IR markers at each corner. After positioning a robotic-couch at the origin with the cube on the table top, 3D coordinates of the cube’s eight corners were acquired by VTS in the VTS coordinate system. Next, positions in reference coordinates (roomcoordinates) were assigned using the known relation between each point. Finally, camera calibration was completed by finding a transformation matrix between VTS and reference coordinate systems and by applying a pseudo inverse matrix method. After the calibration, the accuracy of linear and rotational motions as well as couch sagging could be measured by analyzing the continuously acquired data of the cube while the couch moves to a designated position. Accuracy of the developed software was verified through comparison with measurement data when using a Laser tracker (FARO, Lake Mary, USA) for a robotic-couch installed for proton therapy. Results: VTS system could track couch motion accurately and measured position in room-coordinates. The VTS measurements and Laser tracker data agreed within 1% of difference for linear and rotational motions. Also because the program analyzes motion in 3-Dimension, it can compute couch sagging. Conclusion: Developed QA system provides submillimeter/ degree accuracy which fulfills the high-end couch QA. This work was supported by the National Research Foundation of Korea funded by Ministry of Science, ICT & Future Planning. (2013M2A2A7043507 and 2012M3A9B6055201)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-81: Comparison of Microdosimetric Quantities Calculated Using the Track Structure Monte Carlo Algorithms Geant4-DNA and NOREC

Purpose: Microdosimetric quantities, such as the lineal energy, have been shown to correlate with the biological response to radiation and the relative biological effect of different radiation types. Track-structure Monte Carlo simulations are an important tool for investigating these responses and for developing mechanistic models to explain them. However, some of the cross-sectional data used in these algorithms has large uncertainties; thus, it is important to investigate how the implementation of the different codes affects the quantities of interest. Methods: Two of the most widely-used publicly available track-structure Monte Carlo codes, Geant4-DNA and NOREC, were used generate electron tracks for two particle sources. One source was a mono-energetic parallel beam of electrons with energies from 5 to 500-keV, and the lineal energy for each track was calculated in 1-mm-spheres arranged in planar arrays at multiple distances from the source. The second source was mono-energetic, uniformly-distributed, and isotropic source, and the lineal energy was scored in a single 30-mm-sphere for energies between 300-eV and 5-keV. Results: The dose-mean lineal energy for the parallel-beam simulations almost all agreed within 5%. For the uniformly-distributed source, at the lowest energies there was strong agreement between the algorithms, but the Geant4-DNA simulations showed slightly more high-energy events for more energetic electrons, but the dose-mean lineal energy agreed to within 4% for all energies. Conclusion: While there were slight differences in the results between the codes, these were consistent with previous studies of the stopping power and angular scattering distributions. Importantly, the computation time for Geant4-DNA was larger than for NOREC, largely due to approximations used in the NOREC for energies below 10-eV. This study shows that these approximation does not have a major impact on the microdosimetry on the energy and length scales investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coupled neutronics and species transport simulation of the Molten Salt Reactor Experiment

This paper presents the development of coupling between the molten salt reactor species transport code Mole and the reactor physics code Griffin. Here, in this study, tracking of delayed neutron precursors was investigated in the Molten-Salt Reactor Experiment (MSRE), accounting for changes in fuel flow velocity as a function of position in the primary loop. The neutron transport calculations in Griffin were performed using 11 energy groups, and the species advection calculations in Mole used 6 delayed neutron precursor groups to predict spatial distribution of the neutron flux and neutron precursors in the MSRE. Mole–Griffin was used to calculate $k$ eff and $β$ eff in the reactor as a function of different volumetric flow rates.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗