Design and implementation of the cosmic ray tagger system for the ICARUS detector at FNAL

The ICARUS-T600 Liquid Argon Time Projection Chamber is operating at Fermilab at shallow depth and thus exposed to a high flux of cosmic rays that can fake neutrino interactions. A cosmic ray tagging (CRT) system (∼ 1100 m 2 ), surrounding the cryostat with two layers of fiber embedded plastic scintillators, was developed to mitigate the cosmic ray induced background. Using nanosecond-level timing information, the CRT can distinguish incoming cosmic rays from outgoing particles from neutrino interactions in the TPC. In this paper an overview of the CRT system, its installation and commissioning at Fermilab, and its performance are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstruction for Liquid Argon TPC Neutrino Detectors Using Parallel Architectures.

Neutrinos are particles that interact rarely, so identifying them re-quires large detectors which produce lots of data. Processing this data with thecomputing power available is becoming more dicult as the detectors increasein size to reach their physics goals. In liquid argon time projection chambers(TPCs) the charged particles from neutrino interactions produce ionization elec-trons which drift in an electric field towards a series of collection wires, and thesignal on the wires is used to reconstruct the interaction. The MicroBooNEdetector currently collecting data at Fermilab has 8000 wires, and planned fu-ture experiments like DUNE will have 100 times more, which means that thetime required to reconstruct an event will scale accordingly. Modernization ofliquid argon TPC reconstruction code, including vectorization, parallelizationand code portability to GPUs, will help to mitigate these challenges. The liquidargon TPC hit finding algorithm within theLArSoftframework used acrossmultiple experiments has been vectorized and parallelized. This increases thespeed of the algorithm on the order of ten times within a standalone version onIntel architectures. This new version has been incorporated back intoLArSoftso that it can be generally used. These methods will also be applied to otherlow-level reconstruction algorithms of the wire signals such as the deconvolu-tion. The applications and performance of this modernized liquid argon TPCwire reconstruction will be presented.

Berkman, Sophie↗

Physics prospects with MeV neutrino-argon charged current interactions using enhanced photon detection in future LArTPCs

Here, we investigate MeV-scale electron neutrino charged current interactions in a liquid argon time projection chamber (LArTPC) equipped with an enhanced photon detection system. Using simulations of deposited energy in charge and light calorimetry, we explore the potential for dual calorimetric neutrino energy reconstruction. We found energy reconstruction based on light-only calorimetry has a better resolution than combined charge and light calorimetry when hadrons are produced in these events. Meanwhile, enhanced light detection offers improved nanosecond timing resolution and broad optical coverage, enabling neutron tagging and identification of delayed low-energy gamma emissions. These advancements open new avenues in low-energy neutrino physics in next-generation LArTPCs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Light Yield Calibration in MicroBooNE

The MicroBooNE detector is a Liquid Argon Time Projection Chamber (LArTPC) located along the Booster Neutrino Beam (BNB) at Fermilab. Its primary physics goal is to contribute to addressing the elusive short-baseline MiniBooNE low energy excess. MicroBooNE records and utilises both the ionisation charge and scintillation light produced inside the TPC to select and reconstruct neutrino interactions. The scintillation light collected using a plane of PhotoMultiplier Tubes (PMTs) is also used for accurate event timing and cosmic muon rejection with the latter being an important background for detectors, such as MicroBooNE, located on the surface. A good understanding of light modeling and its related systematic uncertainties is crucial to evaluate their impact on physics analyses. The experience acquired from MicroBooNE regarding how the stability of the scintillation light behaves and evolves during the 5 years of the primary physics run will be discussed as well as the calibration method used. This experience will help with understanding the physics of scintillation light in LArTPCs for the future long-running Short-Baseline Neutrino (SBN) and Deep Underground Neutrino Experiment (DUNE) programs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Xenon doping of liquid argon in ProtoDUNE single phase

The Deep Underground Neutrino Experiment (DUNE) will be the next generation long-baseline neutrino experiment. The far detector is designed as a complex of four LAr-TPC (Liquid Argon Time Projection Chamber) modules with 17 kt of liquid argon each. The development and validation of the first far detector technology is pursued through ProtoDUNE Single Phase (ProtoDUNE-SP), a 770 t LAr-TPC at CERN Neutrino Platform. Crucial in DUNE is the photon detection system that will ensure the trigger of non-beam events — proton decay, supernova neutrino burst and BSM searches — and will improve the timing and calorimetry for neutrino beam events. Doping liquid argon with xenon is a known technique to shift the light emitted by argon (128 nm) to a longer wavelength (178 nm) to ease its detection. The largest xenon doping test ever performed in a LAr-TPC was carried out in ProtoDUNE-SP. From February to May 2020, a gradually increasing amount of xenon was injected to also compensate for the light loss due to air contamination. The response of such a large TPC has been studied using the ProtoDUNE-SP Photon Detection System (PDS) and a dedicated setup installed before the run. With the first it was possible to study the light collection efficiency with respect to the track position, while with the second it was possible to distinguish the xenon light (178 nm) from the LAr light (128 nm). The light shifting mechanism proved to be highly efficient even at small xenon concentrations (<20 ppm in mass) furthermore it allowed recovering the light quenched by pollutants. The light collection improved far from the detection plane, enhancing the photon detector response uniformity along the drift direction and confirming a longer Rayleigh scattering length for 178 nm photons, with respect to 128 nm ones. The charge collection by the TPC was monitored proving that xenon up to 20 ppm does not impact its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ICARUS light detection system (Fermilab Italian summer student program 2023)

The ICARUS T600 detector is the largest Liquid Argon Time Projection Chamber ever used on a neutrino beam, and it acts as the far detector of the Short Baseline Neutrino program at Fermilab. Its purpose is the study of the possibility of the existence of a fourth sterile neutrino in the O(eV2) mass range that could take part in the neutrino oscillations. The light detection system of the ICARUS detector plays the role of localising in space and time the neutrino interactions taking place inside the detector, collecting the argon scintillation photons generated when an event occurs. This light detection system also has a crucial role in the trigger system and the rejection of the huge amount of background cosmic events, working together with the trigger request signals sent by the beam complex. In August 2023 part of the cables that are used to carry the signals from the photomultipliers to the electronics were replaced with a new model, because a deterioration of the quality of the signal inside the cables had previously been observed. An analysis of the performance of the new cables was carried out, comparing laser run data collected before and after the change of the cable model, and it was proved that the introduction of the new cables lead to a general improvement of the quality of the signals reaching the electronics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Studies on the scintillation light detection in the ProtoDUNE Dual Phase liquid-argon TPC and its capability for the supernova trigger in DUNE

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment that aims at addressing key questions in neutrino physics in the next decades. Its scientific program includes the detection of the neutrino flux from a core-collapse supernova. The DUNE far detector will have four 17-kt mass liquid-argon (LAr) time-projection chamber (TPC) modules. ProtoDUNE Dual Phase (DP), a dual-phase LAr TPC with 300 t of active mass and 6 m of drift distance, was operated with cosmic muons in 2019-2020 as part of an R&D program at the CERN Neutrino Platform to demonstrate the feasibility of the technology at such a large scale. In a LAr TPC, the photon detection system (PDS) provides fundamental timing information and trigger capabilities. The PDS of ProtoDUNE-DP, which consisted of 36 photomultiplier tubes (PMTs), counted on a dedicated light calibration system (LCS) to monitor the PMT response. In this dissertation, the characterization and validation of the ProtoDUNE-DP PDS and LCS components before their installation will be reviewed, highlighting the results of general interest for experiments that use liquid noble gasses as target medium. The results from the stable performance of both systems in the detector during 15 months will be presented next as well as the studies on the scintillation light detection in ProtoDUNE-DP, where the collection of light produced in LAr at 7 m from the photosensors has been achieved for the first time. It is worth pointing out that the excellent LAr purity and the large size of the detector have enabled to develop a unique data-driven investigation on aspects that are critical for LAr-based experiments but that are not completely understood. The analyses cover the characterization of the low-energy background detected by the PDS, the quantification of the electric field impact on the light yield, the evaluation of the Rayleigh scattering affecting the light propagation, and the analysis of the PMT detection efficiency. The effect of the VUV reflectivity of the detector materials will be also discussed. In addition, the estimation of the cosmic muon flux crossing the TPC and the study of the observed light yield by the PDS will be reported. Finally, the results from the simulation-based study of the supernova burst trigger capability with the PDS of a 12.1-kt active mass dual-phase LAr TPC as the one proposed for DUNE will be summarized. Several configurations of reflective foils installed in the TPC to enhance the light collection will be compared.

Gallego Ros, Ana↗

Studies on the scintillation light detection in the ProtoDUNE Dual Phase liquid-argon TPC and its capability for the supernova trigger in DUNE

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment that aims at addressing key questions in neutrino physics in the next decades. Its scientific program includes the detection of the neutrino flux from a core-collapse supernova. The DUNE far detector will have four 17-kt mass liquid-argon (LAr) time-projection chamber (TPC) modules. ProtoDUNE Dual Phase (DP), a dual-phase LAr TPC with 300 t of active mass and 6 m of drift distance, was operated with cosmic muons in 2019-2020 as part of an R&D program at the CERN Neutrino Platform to demonstrate the feasibility of the technology at such a large scale. In a LAr TPC, the photon detection system (PDS) provides fun- damental timing information and trigger capabilities. The PDS of ProtoDUNE-DP, which consisted of 36 photomultiplier tubes (PMTs), counted on a dedicated light calibration system (LCS) to monitor the PMT response. In this dissertation, the characterization and validation of the ProtoDUNE-DP PDS and LCS components before their installation will be reviewed, highlighting the results of general interest for experiments that use liquid noble gasses as target medium. The results from the stable performance of both systems in the detector during 15 months will be presented next as well as the studies on the scintillation light detection in ProtoDUNE-DP, where the collection of light produced in LAr at 7 m from the photosensors has been achieved for the first time. It is worth pointing out that the excellent LAr purity and the large size of the detector have enabled to develop a unique data-driven investigation on aspects that are critical for LAr- based experiments but that are not completely understood. The analyses cover the characterization of the low-energy background detected by the PDS, the quantification of the electric field impact on the light yield, the evaluation of the Rayleigh scattering affecting the light propagation, and the analysis of the PMT detection efficiency. The effect of the VUV reflectivity of the detector materials will be also discussed. In addition, the estimation of the cosmic muon flux crossing the TPC and the study of the observed light yield by the PDS will be reported. Finally, the results from the simulation-based study of the supernova burst trigger capability with the PDS of a 12.1-kt active mass dual-phase LAr TPC as the one proposed for DUNE will be summarized. Several configurations of reflective foils installed in the TPC to enhance the light collection will be compared

Gallego-Ros, Ana↗

The Trigger System of ICARUS-T600 Detector at Fermilab

The ICARUS-T600 liquid argon (LAr) time projection chamber (TPC) detector is currently deployed as a far detector of the Short Baseline Neutrino (SBN) program at Fermilab (USA) to search for a possible LSND-like sterile neutrino signal at $\Deltam^2 \approx 1eV^2$ with the Booster (BNB) and Main Injector (NuMI) Neutrino Beams. A global physical event rate of $\approx 0.6$ Hz, including the genuine neutrino interactions in LAr, beam halos and cosmic interactions inside the proton pulse time windows, is expected, roughly corresponding to $\approx 4$ PB of data for the total 6.6 $10^{20}$ pot exposure if the full ICARUS-T600 detector is readout ($\approx 200$ MB event size). The designed trigger system described here will collect the genuine neutrino interactions with a $\approx 95$\% expected efficiency.

Copello, S. [INFN, Pavia]↗

Towards searches for heavy neutral leptons with the Short-Baseline Near Detector experiment

Heavy Neutral Leptons (HNLs) are hypothetical long-lived particles that extend the Standard Model and provide a natural explanation for the origin of neutrino masses, the generation of the baryon asymmetry through leptogenesis, and the nature of dark matter. The Short-Baseline Near Detector (SBND) is a 112-ton liquid argon time projection chamber located 110 m away from the Booster Neutrino Beam (BNB) target at Fermilab (Illinois, USA). The close location to the BNB origin makes the experiment sensitive to HNLs produced from meson decays in the beam. These heavy particles arrive at the detector later than neutrinos and decay into observable final states such as 𝜈e+e- or 𝜈π0, generating isolated electromagnetic showers. Thanks to SBND’s advanced scintillation light detection system, a timing resolution at the nanosecond level further boosts the experiment capabilities. In this poster, we present ongoing reconstruction efforts towards HNLs as well as expected sensitivities factoring in the reconstruction improvements.

Romeo Araujo, Jorge [Madrid, CIEMAT]↗

Performance of the ICARUS Trigger System at the Booster and NuMI Neutrino Beams †

The ICARUS-T600 liquid argon time projection chamber detector takes data at a shallow depth as the far detector of the Short Baseline Neutrino program at Fermilab, searching for sterile neutrinos with the Booster and Main Injector neutrino beams. The ICARUS trigger system exploits the temporal coincidence of the beams with scintillation light signals detected by 360 photo-multiplier tubes in limited TPC regions. The trigger efficiency measurement leverages cosmic rays collected without any scintillation light requirement, with timing from an external cosmic ray tagger system. The efficiency measured with stopping muons roughly saturates at ∼300 MeV, covering most of the expected energy range of charged-current neutrino interactions. For the latest ICARUS physics runs, special “adder” boards performing the analog sum of light signals were introduced as a complementary trigger to possibly recover low-energy neutrino interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Data analysis in the ICARUS (SBN FD) Cosmic Ray Tagging system

When a cosmic ray particle collides with the upper atmosphere, it creates a shower of particles that transverse down to the Earth’s surface. These cosmogenic particles provide a challenging background in neutrino experiments. The Short Baseline Neutrino (SBN) Program is composed of three Liquid Argon Time Projection Chambers (LArTPCs) that will help us understand the elusive neutrino. Together with a Cosmic Ray Tagger (CRT) system, the ICARUS detector serves as the Far Detector in the SBN Program. The CRT surrounds the detector medium and tags incoming particles allowing us to combat the high flux of comic rays we experience at ICARUS. In this poster, I will show some of the first data analyses done with the fully commissioned CRT system, including studies using CRT timing information and CRT hit reconstruction.

43 PARTICLE ACCELERATORS↗

Cosmic Background Rejection of the ICARUS experiment at Fermilab

The Short Baseline Neutrino program at Fermilab aims to explore significant regions of parameter space, applicable to sterile neutrinos at the eV mass scale, as suggested by existing experimental anomalies. To this purpose it exploits Liquid Argon Time Projection Chamber detectors located along the Booster Neutrino Beamline to measure both νe appearance and νµ disappearance: the Short Baseline Neutrino Detector and the ICARUS-T600 detector at 110 and 600 m from the neutrino source, respectively. The ICARUS T-600 Far Detector, located at shallow depth, is surrounded by a Cosmic Ray Tagger system to mitigate the cosmic ray background. On average ~ 11 muon tracks are expected to cross the detector during the ~ 1 ms drift time. The cosmic ray tagger is composed of plastic scintillator bars, ensuring near 4π coverage of the detector aiming at tagging cosmic muons and thus reject 𝛾s produced by muon interactions in the surrounding materials that can generate an electromagnetic showers mimicking a νe signal. The system allows one to disentangle cosmic rays from particles originated in a neutrino interaction inside the detector by measuring their position and crossing time. A synchronization of the cosmic ray tagger with the ICARUS photon detection system with a nanosecond accuracy allows one to reject cosmic particles recorded during the beam spill and thus select an enriched sample of neutrino triggered events ahead of the event reconstruction. An overview of the cosmic ray tagger system as well as its role in the neutrino events identification and cosmic background rejection will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cryogenic Front-End ASICs for Low-Noise Readout of Charge Signals

This paper presents design details and measurement results of LArASIC, a front-end application specific integrated circuit (ASIC) designed for low-noise readout of charge signals generated in neutrino study experiments within liquid argon time projection chambers. LArASIC comprises of 16-channels of programmable charge amplification and pulse shaping stages that provide a voltage readout proportional to the input charge and was optimized for operation at liquid argon temperature, i.e., 89 K. The chip was fabricated in a 180 nm CMOS process. Measurements at liquid nitrogen temperature, i.e., 77 K, indicate that the channel outputs have high linearity (INL < 0.1%) within the operating range, an equivalent noise charge of 534 electrons for a peaking time of 1 µs and a detector capacitance of 150 pF, and a worst-case inter-channel cross-talk of 0.35%. The paper also presents design choices made in the process of migrating LArASIC to CHARMS, an ASIC to be fabricated in a 65 nm process that includes all features provided by LArASIC, along with additional digital programmability for improved robustness and flexibility. CHARMS is intended for use in future high-energy physics experiments that require high-resolution charge or light readout with shorter pulse peaking times.

47 OTHER INSTRUMENTATION↗

First Search for Neutral Current Coherent Single-Photon Production in MicroBooNE

This article presents the first search for neutrino-induced neutral current coherent single-photon production (NC coherent 1$\gamma$). The search makes use of data from the MicroBooNE 85-tonne active volume liquid argon time projection chamber detector, situated in the Fermilab Booster Neutrino Beam (BNB), with an average neutrino energy of $\langle E_{\nu}\rangle \sim 0.8$ GeV. A targeted selection of candidate neutrino interactions with a single photon-like electromagnetic shower in the final state and no visible vertex activity was developed to search for the NC coherent 1$\gamma$ process, along with two auxiliary selections used to constrain the dominant background from NC$\pi^0$ production. With an integrated exposure of $6.87 \times 10^{20}$ protons on target delivered by the BNB, we set the world's first limit for this rare process, corresponding to an upper limit on the flux-averaged cross section of $\sigma<1.49 \times 10^{-41}\text{cm}^2$ at 90% C.L.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Topological background discrimination in the PandaX-III neutrinoless double beta decay experiment

The PandaX-III experiment plans to search for neutrinoless double beta decay (0ν ββ ) of 136 Xe in the China JinPing underground Laboratory (CJPL). The experiment will use a high pressure gaseous time projection chamber (TPC) to register both the energy and the electron track topology of an event. This article is devoted to demonstrate our particular detector setup capabilities for the identification of 0ν ββ and the consequent background reduction. As software tool we use REST, a framework developed for the reconstruction and simulation of TPC-based detector systems. We study the potential for background reduction by introducing appropriate parameters based on the properties of 0ν ββ events. We exploit for the first time not only the energy density of the electron track-ends, but also the electron scattering angles produced by an electron near the end of its trajectory. To implement this, we have added new algorithms for detector signal and track processing inside REST. Their assessment shows that background can be reduced by about 7 orders of magnitude while keeping 0ν ββ efficiency above 20% for the PandaX-III baseline readout scheme, a two-dimensional 3 mm pitch stripped readout. More generally, we use the potential of REST to handle 2D/3D data to assess the impact on signal-to-background significance at different detector granularities, and to validate the PandaX-III baseline choice. Finally, we demonstrate the additional potential to discriminate surface background events generated at the readout plane in the absence of to, by making use of event parameters related with the diffusion of electrons.

Majorana↗

Measuring Electron Diffusion and Constraining the Neutral Current $\pi^0$ Background for Single-Photon Events in MicroBooNE

Liquid Argon Time Projection Chambers (LArTPCs) are a rising technology in the field of experimental neutrino physics. LArTPCs use ionization electrons and scintillation light to reconstruct neutrino interactions with exceptional calorimetric and position resolution capabilities. Here, I present two analyses conducted in the MicroBooNE LArTPC at Fermilab: a measurement of the longitudinal electron diffusion coefficient, $D_L$, in the MicroBooNE detector and a constraint of the systematic uncertainty on MicroBooNE's single-photon analysis due to the dominant neutral current (NC) \piz{} background. Longitudinal electron diffusion modifies the spatial and timing resolution of the detector, and measuring it will help correct for these effects. Furthermore, current measurements of $D_L$ in liquid argon are sparse and in tension with one another, making the MicroBooNE measurement especially valuable. We report a measurement of $3.74^{+0.28}_{-0.29}$ cm$^2$/s. MicroBooNE is searchin g for si ngle-photon events as a potential explanation for the MiniBooNE low-energy excess (LEE) of electron neutrino-like events, which has been interpreted as evidence for low-mass sterile neutrinos. However, this search is overwhelmed by a large NC \piz{} background. By performing a sideband selection of NC \piz{} events, we apply a data-driven rate constraint to the single-photon analysis to reduce the systematic uncertainties. At present, this constraint improves the single-photon analysis' median sensitivity to the LEE-like signal from 0.9$\sigma$ to $1.5\sigma$. This sensitivity is expected to improve significantly as more data become available. Both of these measurements will not only benefit MicroBooNE, but also inform future LArTPC experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The forward TPC system of the NA61/SHINE experiment at CERN: a tandem TPC concept

This paper presents the Forward Time Projection Chamber (FTPC) system of the NA61/SHINE experiment at the CERN SPS accelerator. This TPC system applies a novel tandem-TPC design to reduce the background originating from particle tracks not synchronous with the event trigger. The FTPC system is composed of three chambers with alternating drift field directions. The chambers were installed directly along the beamline region of the NA61/SHINE detector in a medium- to high-intensity (10-100 kHz) hadron or ion beam. The tandem TPC system has proved to be capable of rejecting out-of-time background tracks not associated with a primary interaction. In addition, the system performs tracking and inclusive dE/dx particle identification for particles at and near the beam momentum. This shows that a tandem-TPC-based chamber design may be used also in other experimental applications with a demand for low material budget, tracking capability, and the need for dE/dx particle identification, all while in the presence of a relatively high particle flux.