At least 271 records · Page 15

Large area, low cost space solar cells with optional wraparound contacts

Design parameters for two large area, low cost solar cells are presented, and electron irradiation testing, thermal alpha testing, and cell processing are discussed. The devices are a 2 ohm-cm base resistivity silicon cell with an evaporated aluminum reflector produced in a dielectric wraparound cell, and a 10 ohm-cm silicon cell with the BSF/BSR combination and a conventional contact system. Both cells are 5.9 x 5.9 cm and require 200 micron thick silicon material due to mission weight constraints. Normalized values for open circuit voltage, short circuit current, and maximum power calculations derived from electron radiation testing are given. In addition, thermal alpha testing values of absorptivity and emittance are included. A pilot cell processing run produced cells averaging 14.4% efficiencies at AMO 28 C. Manufacturing for such cells will be on a mechanized process line, and the area of coverslide application technology must be considered in order to achieve cost effective production.

Michaels, D.↗

Utilization fo the Satellite Test Assistant Robot (STAR) for Visual and Thermal Analysis for Articles in the Thermal Vacuum Test Environment

An innovative new telerobotic inspection system called STAR has been developed to asist engineers in the visual and thermal analysis fo flight hardware being tested in a simulated space environment. This paper describes the architecture of the STAR mechanical and control systems and discusses some uses of STAR to date.

STAR satellite test assistant robot space simulati↗

WF/PC internal molecular contamination during system thermal-vacuum test

During the recent system thermal vacuum test of the Wide-Field/Planetary Camera (WF/PC), instrumentation was added to the WF/PC to characterize the internal molecular contamination and verify the instrument throughput down to 1470 angstroms. Analysis of data elements revealed two contaminants affecting the far-ultraviolet (FUV) performance of the WF/PC. The one contaminant (heavy volatile) is correlated with the electronic and housing temperature, and the contamination is significantly reduced when the electronics are operated below plus 8 degrees to plus 10 degrees C. The other contaminant (light volatile) is controlled by the heat pipe temperature, and the contamination is significantly reduced when the Thermal Electric Cooler (TEC) hot-junction temperature is below minus 40 degrees to minus 50 degrees C. The utility of contamination sensors located behind instruments during system tests was demonstrated.

Taylor, Daniel M.↗

Demonstration Test Report: Vacuum Thermal Desorption (VTD) Testing to Support West Area Waste Feed Test 2

Approximately 54 million gallons of radioactive and hazardous waste are stored in underground storage tanks at the U.S. Department of Energy’s (DOE’s) Hanford Site in southeastern Washington State. The Hanford Waste Treatment and Immobilization Plant (WTP) is being constructed to immobilize the waste in glass waste forms. The baseline configuration of the WTP includes a Pretreatment Facility to separate the wastes into a small volume of high-level waste (HLW) containing most of the radioactivity and a larger volume of low-activity waste (LAW) containing most of the non-radioactive chemicals. The HLW will be converted to glass in the HLW vitrification facility for ultimate disposal at a federal repository.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal-vacuum test report for the ultraviolet spectrometer thermal model

Early design studies showed that the UV spectrometer thermal design margins were very small so that an experimental confirmation of the analytical model would be desirable. At that time the prototype unit was scheduled too far downstream to be of value, so a separate thermal model was built for use in verifying the analytical model.

Wingate, C. A., Jr.↗

Apparent-Strain Correction for Combined Thermal and Mechanical Testing

Combined thermal and mechanical testing requires that the total strain be corrected for the coefficient of thermal expansion mismatch between the strain gage and the specimen or apparent strain when the temperature varies while a mechanical load is being applied. Collecting data for an apparent strain test becomes problematic as the specimen size increases. If the test specimen cannot be placed in a variable temperature test chamber to generate apparent strain data with no mechanical loads, coupons can be used to generate the required data. The coupons, however, must have the same strain gage type, coefficient of thermal expansion, and constraints as the specimen to be useful. Obtaining apparent-strain data at temperatures lower than -320 F is challenging due to the difficulty to maintain steady-state and uniform temperatures on a given specimen. Equations to correct for apparent strain in a real-time fashion and data from apparent-strain tests for composite and metallic specimens over a temperature range from -450 F to +250 F are presented in this paper. Three approaches to extrapolate apparent-strain data from -320 F to -430 F are presented and compared to the measured apparent-strain data. The first two approaches use a subset of the apparent-strain curves between -320 F and 100 F to extrapolate to -430 F, while the third approach extrapolates the apparent-strain curve over the temperature range of -320 F to +250 F to -430 F. The first two approaches are superior to the third approach but the use of either of the first two approaches is contingent upon the degree of non-linearity of the apparent-strain curve.

Johnson, Theodore F.↗

Spacecraft thermal vacuum testing

An approach for developing a general thermal vacuum test program philosophy is discussed. Guidelines are established that will assist the project engineer in relating the risk associated with flying any spacecraft to its test program. Computerized techniques can be used to help ascertain these guidelines, which relate the risk to the level of test (component, subsystem, etc), as well as to the type of test (development, qualification, etc). The interrelationship between the test program and the analytical effort is also discussed. The Skylab Apollo telescope mount general thermal vacuum test program, including test schedules, instrumentation, and test results is also discussed.

Elam, B. F.↗

Short xEMU Pressure Garment Thermal Vacuum Test Results

NASA performed a thermal-vacuum test of the Exploration Extravehicular Mobility Unit (xEMU) to demonstrate the performance of the government reference design in a relevant space-like environment. One of the spacesuit test articles was configurated as a Short-xEMU (SxEMU). This unmanned configuration provided an excellent test to evaluate the Exploration Portable Life Support System (xPLSS), however it posed some challenges with the Exploration Pressure Garment (xPGS) components involved due to the lack of a human wearing a Liquid Cooling and Ventilation Garment (LCVG), which significantly contributes to the thermal performance of the suit. This paper provides an overview of the pressure garment components that made up this portion of the test article, the test configuration, test results, and lessons learned from this very unique spacesuit test.

xemu↗

Thermal Hydraulic Experimental Test Article - Report of THETA Commissioning for METL Testing

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, [1], further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned before installing into METL test vessel #4. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Contact thermal shock test of ceramics

A novel quantitative thermal shock test of ceramics is described. The technique employs contact between a metal-cooling rod and hot disk-shaped specimen. In contrast with traditional techniques, the well-defined thermal boundary condition allows for accurate analyses of heat transfer, stress, and fracture. Uniform equibiaxial tensile stresses are induced in the center of the test specimen. Transient specimen temperature and acoustic emission are monitored continuously during the thermal stress cycle. The technique is demonstrated with soda-lime glass specimens. Experimental results are compared with theoretical predictions based on a finite-element method thermal stress analysis combined with a statistical model of fracture. Material strength parameters are determined using concentric ring flexure tests. Good agreement is found between experimental results and theoretical predictions of failure probability as a function of time and initial specimen temperature.

Rogers, W. P.↗

Multipurpose Thermal Insulation Test Apparatus

A multi-purpose thermal insulation test apparatus is used for testing insulation materials, or other components. The test apparatus is a fluid boil-off calorimeter system for calibrated measurement of the apparent thermal conductivity (k-value) of a specimen material at a fixed vacuum level. The apparatus includes an inner vessel for receiving a fluid with a normal boiling point below ambient temperature, such as liquid nitrogen, enclosed within a vacuum chamber. A cold mass assembly, including the inner vessel and thermal guards, is suspended from the top of the vacuum chamber. Handling tools attach to the cold mass assembly for convenient manipulation of the assembly and for the installation or wrapping of insulation test materials. Liquid nitrogen is typically supplied to the inner vessel using a fill tube with funnel. A single port through the top of the vacuum chamber facilitates both filling and venting. Aerogel composite stacks with reflective films are fastened to the top and the bottom of the inner vessel as thermal guards. The comparative k-value of the insulation material is determined by measuring the boil-off flow rate of gas, the temperature differential across the insulation thickness, and the dimensions (length and diameters) of the test specimen.

Fesmire, James E.↗

Thermal Vacuum Testing of a Helium Loop Heat Pipe for Large Area Cryocooling

Future NASA space telescopes and exploration missions require cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks. One device that can potentially be used to provide closed-loop cryocooling is the cryogenic loop heat pipe (CLHP). A CLHP has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A helium CLHP has been tested extensively in a thermal vacuum chamber using a cryocooler as the heat sink to characterize its transient and steady performance and to verify its ability to cool large areas or components in the 3 degrees Kelvin temperature range. The helium CLHP thermal performance test included cool-down from the ambient temperature, startup, capillary limit, heat removal capability, rapid power changes, and long duration steady state operation. The helium CLHP demonstrated robust operation under steady state and transient conditions. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully by simply applying power to both the capillary pump and the evaporator plate without pre-conditioning. It could adapt to a rapid heat load change and quickly reach a new steady state. Heat removal between 10 megawatts and 140 megawatts was demonstrated, yielding a power turn down ratio of 14. When the CLHP capillary limit was exceeded, the loop could resume its normal function by reducing the power to the capillary pump. Steady state operations up to 17 hours at several heat loads were demonstrated. The ability of the helium CLHP to cool large areas was therefore successfully verified.

Thermal Control Systems↗

Mechanical and Thermal Prototype Testing for a Rotatable Collimator for the LHC Phase II Collimation Upgrade

The Phase II upgrade to the LHC collimation system calls for complementing the robust Phase I graphite collimators with high Z, low impedance Phase II collimators. The design for the collimation upgrade has not been finalized. One option is to use metallic rotatable collimators and testing of this design will be discussed here. The Phase II collimators must be robust in various operating conditions and accident scenarios. A prototype collimator jaw has been tested for both mechanical and thermal compliance with the design goals. Thermal expansion bench-top tests are compared to ANSYS simulation results.

43 PARTICLE ACCELERATORS↗