Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature checks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

A Quantitative Evaluation of Dissolved Oxygen Instrumentation

The implications of the presence of dissolved oxygen in water are discussed in terms of its deleterious or beneficial effects, depending on the functional consequences to those affected, e.g., the industrialist, the oceanographer, and the ecologist. The paper is devoted primarily to an examination of the performance of five commercially available dissolved oxygen meters. The design of each is briefly reviewed and ease or difficulty of use in the field described. Specifically, the evaluation program treated a number of parameters and user considerations including an initial check and trial calibration for each instrument and a discussion of the measurement methodology employed. Detailed test results are given relating to the effects of primary power variation, water-flow sensitivity, response time, relative accuracy of dissolved-oxygen readout, temperature accuracy (for those instruments which included this feature), error and repeatability, stability, pressure and other environmental effects, and test results obtained in the field. Overall instrument performance is summarized comparatively by chart.

Pijanowski, Barbara S.↗

Yield and PDV Measurements of the Godiva-IV Critical Assembly (Preliminary Report)

A high dynamic range, scinillator based detector, the MHD-240, was used to measure the gamma and neutron flux of several prompt critical bursts of the Godiva-IV assembly. The measurements provided the alpha and FWHM for several different burst temperatures. Calibrations of the MHD240 gamma and neutron sensitivity along with MCNP based simulation of the Godiva-IV assembly will allow us to also determine the total fission yield of the burst integrated over approximately 5 ms. Work is ongoing to check the calibrations of the MHD-240, and improve the MCNP simulations. This is a preliminary report, and the fission yields reported here are not final and are likely inaccurate. The measured alpha and FWHM are not impacted by the calibration issues and are considered final.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Shuttle era - A challenge to the earth scientist

Satellite observations of large-scale earth features and phenomena, with either instruments or astronauts, are discussed on the basis of earlier experience (mainly Skylab). Off-nadir views and photographs by astronauts have provided valuable supplements to instrument nadir views, providing cross-checks through remote sensing at different angles, different altitudes, and in different seasons. New information on plate tectonics, global cooling/drying trends, global oceanographic data (changing positions of major ocean current patterns, evolution of warm and cold eddies and their relation to sea temperatures and concentrations of marine fauna, location of internal sea waves, interactions between ocean currents and atmosphere, plankton blooms), storm development, snow cover patterns, lake and sea ice growth, sand-dune patterns, desert storms blown out to sea, effects of grazing and swidden agriculture, and other earth features and phenomena are surveyed.

Muehlberger, W. R.↗

DC Performance Testing of MgB2 Superconducting Straight Wire Samples

To enable turboelectric aircraft that utilize fully superconducting motors and generators, testing of high-current, low-AC-loss superconducting wires and coils must be performed. A preliminary investigation was conducted on the critical current capabilityof a magnesium diboride sample and on the complications that arise from testing the sample with a cryocooler. While a cryocooler provides the benefit of a wide and continuous operating temperature range, cooling a sample by conduction through solid media without a heat-exchange gas is difficult. This paper outlines the hardware and software used to conduct the first DC performance tests on magnesium diboride superconducting samples, along with several check-out tests and mitigation steps needed to produce quality superconducting data using a cryocooler rather than a cryogen

Superconductor↗

Laser speckle technique for burner liner strain measurements

Thermal and mechanical strains were measured on samples of a common material used in jet engine burner liners, which were heated from room temperature to 870 C and cooled back to 220 C, in a laboratory furnance. The physical geometry of the sample surface was recorded at selected temperatures by a set of 12 single exposure speckle-grams. Sequential pairs of specklegrams were compared in a heterodyne interferometer which give high precision measurement of differential displacements. Good speckle correlation between the first and last specklegrams is noted which allows a check on accumulate errors.

Stetson, K. A.↗

Investigative techniques used to locate the liquid hydrogen leakage on the Space Shuttle Main Propulsion System

Standard leak detection methods at ambient temperature have been developed in order to prevent excessive leakage from the Space Shuttle liquid oxygen and liquid hydrogen Main Propulsion System. Unacceptable hydrogen leakage was encountered on the Columbia and Atlantis flight vehicles in the summer of 1990 after the standard leak check requirements had been satisfied. The leakage was only detectable when the fuel system was exposed to subcooled liquid hydrogen during External Tank loading operations. Special instrumentation and analytical tools were utilized during a series of propellant tanking tests in order to identify the sources of the hydrogen leakage. After the leaks were located and corrected, the physical characteristics of the leak sources were analyzed in an effort to understand how the discrepancies were introduced and why the leakage had evaded the standard leak detection methods. As a result of the post-leak analysis, corrective actions and leak detection improvements have been implemented in order to preclude a similar incident.

Hammock, William R., Jr.↗

The cross correlation of the ABS and ACT maps

One of the most important checks for systematic errors in CMB studies is the cross correlation of maps made by independent experiments. In this study we report on the cross correlation between maps from the Atacama B-mode Search (ABS) and Atacama Cosmology Telescope (ACT) experiments in both temperature and polarization. These completely different measurements have a clear correlation with each other and with the Planck satellite in both the EE and TE spectra at ℓ<400 over the roughly 0110 deg 2 common to all three. The TB, EB, and BB cross spectra are consistent with noise. Exploiting such cross-correlations will be important for future experiments operating in Chile that aim to probe the 30<ℓ<8,000 range.

79 ASTRONOMY AND ASTROPHYSICS↗

Production Facility Simulations for Annular LEU Targets

Eden Radioisotopes, LLC is designing a new molybdenum-99 (Mo-99) production facility based on a TRIGA-sized reactor with a core composed of low enriched uranium (LEU) targets. Reactor production is designed to exceed U.S. demand for Mo-99 using the fission processes. The nominal operational power is 1.8MW (less than 2.0MW, to satisfy the “non-power” reactor requirement) and desired irradiation scenarios include 7, 14, or 21 days of the irradiation for each target element. Safety limits for reactor operating margins are associated with such physical phenomena as fission gas release, fuel swelling, and stress cracking. As shown in the literature, one of the critical parameters defining safety margins for metallic uranium fuel is swelling. In its turn the fuel operational temperature is the main parameter impacting the swelling rate. This report documents the results of consecutive studies of reactor criticality, fission energy depositions, and cooling conditions for the target. The maximum temperature calculated for the LEU targets allows us to choose appropriate modeling approximation of the swelling. All obtained results refer to the preliminary targets and core designs provided by Eden. A criticality analysis was performed, and the results are listed mainly to cross-check Eden’s safety report and assume maximal neutron field disturbance for maximal reactivity. A brief description of the metallic uranium swelling model is provided in the Appendix.

07 ISOTOPE AND RADIATION SOURCES↗

The Cross Correlation of the ABS and ACT Maps

One of the most important checks for systematic errors in CMB studies is the cross correlation of maps made by independent experiments. In this paper, we report on the cross correlation between maps from the Atacama B-mode Search (ABS) and Atacama Cosmology Telescope (ACT) experiments in both temperature and polarization. These completely different measurements have a clear correlation with each other and with the Planck satellite in both the EE and TE spectra at l < 400 over the roughly 1100 deg(exp 2) common to all three. The TB, EB, and BB cross spectra are consistent with noise. Exploiting such cross-correlations will be important for future experiments operating in Chile that aim to probe the 30 < l < 8,000 range.

CMBR experiments↗

Groundwater table elevation and temperature from 2015 to 2024 at the Lower Montane site in the East River Watershed, Colorado.

This groundwater level elevation and temperature data package is aimed at improving the predictive understanding of hydro-biogeochemical processes at the lower montane site in the East River Watershed, Colorado. The dataset is obtained using pressure transducers placed in shallow wells in the floodplain. This dataset contains data from wells with Location ID's ER-DOW (alias DO1West), ER-DOE (alias DO2East), ER-MBA1 (alias M1Bend1), ER-MBA2 (alias M1Bend2), ER-UPW (alias UP1West), ER-UPM (alias UP2), ER-UPE (alias UP3East). Another dataset contains the data from wells with Location ID's ER-CPA1 to ER-CPA6. Each file contains the water level elevation and the water temperature. Water level elevation has been obtained using the barometric pressure from the pressure transducer (Hobos sensor) in the well, barometric pressure from a sensor in air located at the same site (lower montane), depth from top-of-casing (TOC) to sensor measurement point, and TOC elevation. Data have been checked with a few measurements of water table depths. A real-time kinematic (RTK) global positioning system (GPS) has been used to survey the TOC (data in file Well_Location.csv). The water level elevation is given in UTM13N Geoid2012AB. While depth to water level is not present in the data files, it can be easily calculated with the TOC and distance to ground provided in the GPS coordinate file. The dataset quality is discussed in Collection/Analysis section of the methods. Time-series of measurements were initially added to the archive for the period 2015 to 2019, and later updated with time-series until 2024 (end of data collection). The dataset contains 8 *.csv data files, and 3 *.csv metadata files. Feel free to contact the author with any questions or collaboration interests. The publication year was updated from "2020" to "2025" to reflect the revised version of this dataset.

54 ENVIRONMENTAL SCIENCES↗

Groundwater table elevation and temperature from 2015 to 2024 across Meander C at the Lower Montane site in the East River Watershed, Colorado.

This groundwater level elevation and temperature data package is aimed at improving the predictive understanding of hydro-biogeochemical processes at the lower montane site in the East River Watershed, Colorado. The dataset is obtained using pressure transducers placed in shallow wells in the floodplain. This dataset contains data from wells ER-CPA1 to ER-CPA6. Another dataset contains the data from wells at nearby Locations. Each file contains the water level elevation and the water temperature. Water level elevation has been obtained using the barometric pressure from the pressure transducer (Hobos sensor) in the well, barometric pressure from a sensor in air located at the same site (lower montane), depth from top-of-casing (TOC) to sensor measurement point, and TOC elevation. Data have been checked with a few measurements of water table depths. A real-time kinematic (RTK) global positioning system (GPS) has been used to survey the TOC (data in file Well_Location.csv). The water level elevation is given in UTM13N Geoid2012AB. While depth to water level is not present in the data files, it can be easily calculated with the TOC and distance to ground provided in the GPS coordinate file. The dataset quality is discussed in Collection/Analysis section of the methods. Time-series of measurements were initially added to the archive for the period 2015 to 2019, and later updated with time-series until 2024 (end of data collection). The dataset contains 7 *.csv data files, and 3 *.csv metadata files. Feel free to contact the author with any questions or collaboration interests. The publication year was updated from "2020" to "2025" to reflect the revised version of this dataset.

54 ENVIRONMENTAL SCIENCES↗

Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Performance Verification Report: METSAT Phase Locked Oscillator Assembly, P/N 1334360-1, S/N's F03 and F04

Two Flight Model AMSU-A Phase Locked Oscillators (P/N 1348360-1, S/Ns F03 and F04) have been tested per AES Test Procedure AE-26758. The tests included vibration testing, thermal cycle testing, AM/FM Noise testing, and full functional testing. EMI/REO 2 Testing was not performed. (See test data for S/N F01). Both AMSU-A Phase Locked Oscillators satisfactorily passed all performance requirements of the AE-26633 Product specification. During thermal cycling of PLO serial number F03, the oven and data logger momentarily lost power, including a loss of data. The unit did not experience any thermal stress. TAR 003134 describes the corrective action. Prior to testing PLO serial number FO4, power was applied to the unit. (+15v,-15v) the unit did not display the proper phase lock. Upon test equipment check out a connector was found to be defective. TAR 003133 describes the corrective action. After completion of testing of PLO serial number F04 was installed into Receiver Assembly F02. Upon testing F02 Receiver Assembly the unit was found not to phase lock at ambient temperature. Removal of PLO Assembly F04 was required. R2 was the real issue. Solithane was secondary. Troubleshooting revealed excessive solithane on inner PLL Assembly cover inhibiting optimum grounding. Also, R2 was reselected which increased the lock range from -30 C to +60 C. TAR 002737 describes the corrective action.

Pines, D.↗

CO2 Insulation for Thermal Control of the Mars Science Laboratory

The National Aeronautics and Space Administration (NASA) is sending a large (>850 kg) rover as part of the Mars Science Laboratory (MSL) mission to Mars in 2011. The rover's primary power source is a Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) that generates roughly 2000 W of heat, which is converted to approximately 110 W of electrical power for use by the rover electronics, science instruments, and mechanism-actuators. The large rover size and extreme thermal environments (cold and hot) for which the rover is designed for led to a sophisticated thermal control system to keep it within allowable temperature limits. The pre-existing Martian atmosphere of low thermal conductivity CO2 gas (8 Torr) is used to thermally protect the rover and its components from the extremely cold Martian environment (temperatures as low as -130 deg C). Conventional vacuum based insulation like Multi Layer Insulation (MLI) is not effective in a gaseous atmosphere, so engineered gaps between the warm rover internal components and the cold rover external structure were employed to implement this thermal isolation. Large gaps would lead to more thermal isolation, but would also require more of the precious volume available within the rover. Therefore, a balance of the degree of thermal isolation achieved vs. the volume of rover utilized is required to reach an acceptable design. The temperature differences between the controlled components and the rover structure vary from location to location so each gap has to be evaluated on a case-by-case basis to arrive at an optimal thickness. For every configuration and temperature difference, there is a critical thickness below which the heat transfer mechanism is dominated by simple gaseous thermal conduction. For larger gaps, the mechanism is dominated by natural convection. In general, convection leads to a poorer level of thermal isolation as compared to conduction. All these considerations play important roles in the optimization process. A three-step process was utilized to design this insulation. The first step is to come up with a simple, textbook based, closed-form equation assessment of gap thickness vs. resultant thermal isolation achieved. The second step is a more sophisticated numerical assessment using Computational Fluid Dynamics (CFD) software to investigate the effect of complicated geometries and temperature contours along them to arrive at the effective thermal isolation in a CO2 atmosphere. The third step is to test samples of representative geometries in a CO2 filled chamber to measure the thermal isolation achieved. The results of these assessments along with the consistency checks across these methods leads to the formulation of design-guidelines for gap implementation within the rover geometry. Finally, based on the geometric and functional constraints within the real rover system, a detailed design that accommodates all these factors is arrived at. This paper will describe in detail this entire process, the results of these assessments and the final design that was implemented.

CO2↗

Identification and Study of Validation Level Test Cases for Computational Modeling of Non-Charring Ablators

Computational modeling of Thermal Protection System (TPS) materials, used for aerospace applications, provides numerous advantages in preliminary selection and design of a heatshield material and shape for atmospheric entry vehicles. However, to serve as a reliable tool for prediction of material thermal and ablative behavior, the modeling approach needs to be validated against real experimental and flight data, preferably at a range of applied conditions. The validation study is typically very complex as it requires reliable measured data not only for the material thermal response and surface recession, but also well characterized environmental conditions. The validation problem becomes even more complex when the material thermal response is dictated by multi-physics effects such as solid conduction, in-depth thermal decomposition, pyrolysis gas flow and chemical reactions. The multi-physics effects complicate not only the modeling effort, but also the experimental measurement for validation of various aspects of the highly coupled problem. In this study, an attempt is made to identify suitable experimental data that could serve as a source for validation of material thermal response modeling tools. To reduce the computational complexity, this study focuses only on non-charring ablators, where the material thermal response could be modeled with a single governing equation for solid conduction and the ablation is limited only to the surface of the material. With a well characterized and publicly available experimental data being sparse, the study is limited in presenting test cases for only three materials: camphor, graphite and FiberForm® in the sequence of increased modeling complexity. Graphite is a commonly used TPS material for aerospace applications, both for leading edges of high-speed vehicles and internal insulation of solid rocket motors. FiberForm® is a porous carbon pre-form used in preparation of the well known PICA material Tran et al. [1996]. Inclusion of camphor into the list is conditioned with the relative simplicity in modeling the material thermal and chemical response and the low-enthalpy flow environment. In addition, camphor has been used as a simple test material for study of flow transition behavior by Stock and Ginoux [1973] and assessment of a heatshield shape change at flight relevant conditions by Rotondi et al. [2022]. In this work, the identified experimental data was extracted from the public literature and test cases that yet have been published. As it was found from the review, not a single test case contains an exhaustive set of data that would validate every aspect of the material physics. However, in the data collected, various aspects of the material behavior can be still validated, such as surface and in-depth temperature, amount of recession and a shape change. The identified experimental data for each case is accompanied with a characterized flow environment and simulated boundary conditions predicted by a Data-Parallel Line Relaxation (DPLR) code Wright et al. [1998]. In addition, material thermal response numerical simulations in each test case are performed with Kentucky Aerothermodynamics and Thermal Response System (KATS-MR) Zibitsker et al. [2022] providing a comparative study and a sanity check for the proposed validation data. Sample results from the performed numerical study are shown below. Figure 1 shows distribution of surface heat flux and pressure values on a hemi-cylinder model made of FiberForm® and tested in HyMETS arc-jet facility. The results are shown for the high pressure condition among the two tests. Flow simulation was performed with DPLR code on a quarter of original geometry. In the figure, the quarter shape was mirrored across zx and xy planes to show the complete distribution. Figure 2 shows the material response results for the high pressure case (7500 Pa), simulated with KATS-MR and a comparison to the experimental data for the surface temperature and shape shape. The simulation was performed on a 2-D slice, extracted in the xy plane at the middle of the sample. Figure 3 shows the material response simulation for the low pressure case (3500 Pa) and a comparison to the experimental data for surface temperature and shape change.

ablation↗

Determination of elastic stresses in gas-turbine disks

A method is presented for the calculation of elastic stresses in symmetrical disks typical of those of a high-temperature gas turbine. The method is essentially a finite-difference solution of the equilibrium and compatibility equations for elastic stresses in a symmetrical disk. Account can be taken of point-to-point variations in disk thickness, in temperature, in elastic modulus, in coefficient of thermal expansion, in material density, and in Poisson's ratio. No numerical integration or trial-and-error procedures are involved and the computations can be performed in rapid and routine fashion by nontechnical computers with little engineering supervision. Checks on problems for which exact mathematical solutions are known indicate that the method yields results of high accuracy. Illustrative examples are presented to show the manner of treating solid disks, disks with central holes, and disks constructed either of a single material or two or more welded materials. The effect of shrink fitting is taken into account by a very simple device.

Manson, S S↗

In-line, High-Throughput Quality Monitoring for Fuel Cell and Electrolyzer Components Based on Transmission and Reflection Imaging

During the manufacturing of fuel cell and electrolyzer membranes and membrane electrode assemblies (MEAs), real-time, in-line, high-throughput optical-based quality monitoring methods are essential for detecting defects and monitoring thickness variations, thus improving the performance and increasing the durability of fuel cell and electrolyzer in the hydrogen industry. For the MEAs with very opaque coatings, optical transmission-based imaging has been developed and applied in the Roll-to-Roll system using a flashlight and a high-sensitivity CCD camera. We observed high signal-to-noise ratio images while the Roll-to-Roll system ran at 5 ft/min. The entire sample image could quickly be recovered from the discrete frames using customized Python codes for automatic frame cropping and stitching. We detected significant non-uniformities in our experimental MEAs specimen. For fuel cell and low-temperature electrolysis (LTE) transparent membranes, we used optical reflectance hyperspectral imaging with interference fringe-based thickness mapping. We set up a hyperspectral camera to measure various rolls of commercial membranes. The measurement results are analyzed to find the thickness distribution of each roll and to check for defects. Transmission and reflection imaging-based quality monitoring techniques demonstrated in this project can be widely used in the mass production environment to improve the production yield and performance of hydrogen devices.

DIRECT ENERGY CONVERSION,ENGINEERING↗

Measurement of gravitational lensing of the cosmic microwave background using SPT-3G 2018 data

We present a measurement of gravitational lensing over 1500 deg 2 of the Southern sky using SPT-3G temperature data at 95 GHz and 150 GHz taken in 2018. The lensing amplitude relative to a fiducial Planck 2018 Lambda cold dark matter ( Λ CDM ) cosmology is found to be 1.020 ± 0.060 , excluding instrumental and astrophysical systematic uncertainties. We conduct extensive systematic and null tests to check the robustness of the lensing measurements, and report a minimum-variance combined lensing power spectrum over angular multipoles of 50 < L < 2000 , which we use to constrain cosmological models. When analyzed alone and jointly with primary cosmic microwave background (CMB) spectra within the Λ CDM model, our lensing amplitude measurements are consistent with measurements from SPT-SZ, SPTpol, ACT, and Planck. Incorporating loose priors on the baryon density and other parameters including uncertainties on a foreground bias template, we obtain a 1 σ constraint on σ 8 Ω m 0.25 = 0.595 ± 0.026 using the SPT-3G 2018 lensing data alone, where σ 8 is a common measure of the amplitude of structure today and Ω m is the matter density parameter. Combining SPT-3G 2018 lensing measurements with baryon acoustic oscillation (BAO) data, we derive parameter constraints of σ 8 = 0.810 ± 0.033 , S 8 ≡ σ 8 ( Ω m / 0.3 ) 0.5 = 0.836 ± 0.039 , and Hubble constant H 0 = 68.8 - 1.6 + 1.3 km s - 1 Mpc - 1 . Our preferred S 8 value is higher by 1.6 to 1.8 σ compared to cosmic shear measurements from DES-Y3, HSC-Y3, and KiDS-1000 at lower redshift and smaller scales. We combine our lensing data with CMB anisotropy measurements from both SPT-3G and Planck to constrain extensions of Λ CDM . Using CMB anisotropy and lensing measurements from SPT-3G only, we provide independent constraints on the spatial curvature of Ω K = 0.01 4 - 0.026 + 0.023 (95% C.L.) and the dark energy density of Ω Λ = 0.72 2 - 0.026 + 0.031 (68% C.L.). When combining SPT-3G lensing data with SPT-3G CMB anisotropy and BAO data, we find an upper limit on the sum of the neutrino masses of ∑ m ν < 0.30 eV (95% C.L.). Due to the different combination of angular scales and sky area, this lensing analysis provides an independent check on lensing measurements by ACT and Planck.

79 ASTRONOMY AND ASTROPHYSICS↗

Computation of Jupiter interior models from gravitational inversion theory

Spacecraft measurements of Jupiter have provided the mass, standard pressure level radius, rotation law, internal mass distribution multipole moments, and internal composition and temperature distribution constraints, for the present implementation of a method for deriving planetary interior models that exactly satisfy a set of N gravitational constraints by means of appropriate iteration. The models are not forced to fit the more indirectly derived constraints, which are instead used as conistency checks. In the case of an He mass fraction in the envelope Y of 0.2, the inferred pressure at a mass density of about 0.2 g/cu cm is about a factor of 2 higher than would be indicated by experimental H compression data in the relevant pressure range of 100,000 to one million bar. The inferred pressure distribution is in better agreement with the shock data for a nominal Y value of 0.3 + or - 0.05.

Hubbard, W. B.↗