The Probability of False Go/No-Go Determined by GOES Proton Flux: Proposed Launch Constraints for Avoiding Damaging Solar Energetic Particle Events

The space environment is full of harmful radiation and high energy particles that can cause damage to materials and affect computer systems by e.g., single event effects (SEEs), total ionizing dose (TID), etc. There are three main sources of high energy particles: Trapped radiation in Earth's Van Allen belts (electrons and protons); Solar energetic particles (SEPs) (protons and heavy ions); Galactic cosmic rays (GCRs) (protons and heavy ions). In this study, we focus on the SEPs and their time series and energy spectrum to quantify probabilities of launch go/no-go. The SEPs originate from solar particle events (SPEs) that are associated with a solar flare and/or a coronal mass ejection (CME). These events are difficult to predict. Recent work has been done on these prediction techniques. The Geostarionary Operational Environmental Satellite (GOES) has been observing SEPs for decades. The greater than 10 megaelectronvolt proton flux is shown in Figure 2 since 1986. The SEPs are influenced by the 11-year solar cycle and typically come from active regions on the Sun.

DeStefano, Anthony M.↗

Radiation Hardness Study on SiC Power MOSFETs

As an emerging technology, silicon carbide (SiC) power MOSFETs are showing great potential for higher temperature/power rating, higher efficiency, and reduction in size and weight, which makes this technology ideal for high temperature, harsh environment applications such as downhole, medical, avionic, or even space applications. Radiation tolerance therefore becomes a critical aspect of the device performance in such environments. In this work, we explored radiation hardness of SiC devices to total ionizing dose (TID), neutron-induced single-event burnout (SEB), and heavy-ion induced single-event effects (SEE).

SiC↗

Total Ionizing Dose Response of SDRAM, DDR2 and DDR3 Memories

Total Ionizing Dose response (ID) of SDRAM (Synchronous Dynamic Random Access Memory), DDR2 (Double Data Rate2) and DDR3 (Double Data Rate3) memories is reported in static bias, and auto refresh modes. Data analysis reveals some types of memory have significant increases in stuck bits during TID exposure when refreshed.

Amrbar, Mehran↗

High Density Packaging Technologies for RF Electronics in Small Spacecraft

This paper will describe a few high density packaging technologies which we are currently exploring for use in current and future small spacecraft applications. The three categories of technologies include organic multichip modules (MCMs), ceramic leadless surface mount technology (SMT) and 3D printed waveguide structures. There are many other packaging technologies that currently exist but these three were selected in part due to their long heritage in various commercial, military and space applications along with each having a relatively clear path to flight. For each of these technologies, detailed examples will be included in which hardware has been fabricated and tested for use in RF electronics for spacecraft transponders. The organic MCM example will be described in most detail and it utilizes a packaging technology by the name of CoreEZ which is a trademark of i3 Electronics. This MCM has shrunk a portion of our electronics down to 1/8th of its previous area. The CoreEZ technology has been shown to be rad hard beyond a total ionizing dose (TID) of 300kRad and the MCM which was fabricated has gone through thermal cycling and shown to have no degradation in performance. The ceramic leadless package examples include packages from high reliability manufactures by the name of KCB solutions and Barry Industries. In the case of KCB solutions, we have multiple products that will be described including a hermetic ceramic carrier which houses three microwave monolithic integrated circuits (MMICs) along with small discrete components. Finally, we will discuss the results of our search for a 3D printing process that allows us to reduce the cost and volume of our waveguide filters and diplexers for low cost small satellite applications. We have fabricated a few prototypes using direct metal laser sintering (DMLS) and metal coated plastics. Each of these packaging technology discussions will have a brief overview of its current and future use.

Aquirre, Fernando↗

Goddard Modular SmallSat Architecture (GMSA) Hardware Presentation

In today's rapidly advancing technology roadmap for space applications there is an emphasis on completing missions faster and cheaper than previous large-scale missions at the National Aeronautics and Space Administration (NASA) such as the Magnetospheric Multiscale (MMS) mission. As part of this effort, focus has shifted from using mostly radiation-tolerant or radiation-hardened parts to more commercial-off-the-shelf (COTS) components for missions that can last at least one year in orbit. However, there are some portions of a spacecraft's avionics, such as the command and data handling (C&DH) system and the Electrical Power Systems (EPS) that need to have some level of predictable reliability that goes beyond the capabilities of currently available COTS parts. While there are a number of COTS components that can withstand a total ionizing dose (TID) of tens or hundreds of kilorads, there is still a great deal of concern about tolerance to and mitigation of single-event effects (SEE).

Fraction, James↗

Total Ionizing Dose Test of Silicon Switching Transistors JANTXV2N2222AUB

Semicoa's silicon switching transistors, JANTXV2N2222AUB was tested for total ionizing dose (TID) response beginning on November 4, 2019. This test served as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) could be determined.

Campola, M.↗

Total Ionizing Dose Test of Analog Devices’ AD654 Voltage to Frequency Converter

Analog Devices’ AD654 was tested for total ionizing dose (TID) response beginning on February 13, 2017. This device has the Radiation Effects and Analysis Group Identification (REAG ID) number 16-036. This test served as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) could be determined.

B. Freeman↗

A CubeSat-Payload Radiation-Reliability Assurance Case using Goal Structuring Notation

CubeSats have become an attractive platform for universities, industry, and government space missions because they are cheaper and quicker to develop than full-scale satellites. One way CubeSats keep costs low is by using commercial off-the-shelf parts (COTS) instead of space-qualified parts. Space-qualified parts are often costlier, larger, and consume more power than their commercial counterparts precluding their use within the CubeSat form-factor. Given typical power budgets, monetary budgets, and timelines for CubeSat missions, conventional radiation hardness assurance, like the use of space-qualified parts and radiation testing campaigns of COTS parts, is not practical. Instead, a system-level approach to radiation effects mitigation is needed. In this paper an assurance case for a system-level approach to mitigate radiation effects of a CubeSat science experiment is expressed using Goal Structuring Notation (GSN), a graphical argument standard. The case specifically looks at three main mitigation strategies for the radiation environment: total ionizing dose (TID) screening of parts, detection and recovery from single-event latch-ups (SEL) and single-event functional interrupts (SEFI). The graphical assurance case presented makes a qualitative argument for the radiation reliability of the CubeSat experiment using part and system-level mitigation strategies.

COTS↗

AD8065 Voltage Feedback Amplifier’s Total Ionizing Dose Characterization Report

The purpose of this testing was to characterize Analog Devices’ AD8065 FastFET amplifier for low-dose rate (LDR) total ionizing dose (TID) response based on the Lucy project requirements and will be used on the L’ORRI instrument being built by Johns Hopkins University Applied Physics Lab. The AD8065 is a voltage feedback amplifier with FET inputs developed with the proprietary eXtra Fast Complementary Bipolar (XFCB) process. The amplifier boasts low noise operation and very high input impedance with a wide supply voltage range.

Megan Casey↗

Guideline for ground radiation testing of microprocessors in the space radiation environment

The goal of this work is to develop a guideline that is applicable to processors that are potentially useful in space. Thus, the guideline does not consider very high performance processors that are intended for server or high-performance applications where very large amounts of power are tolerated to gain performance because it would be impractical to use such high-power devices in typical space applications. This guide is intended to support insertion of these microprocessors into spaceflight applications and to recommend ground test protocols. The first guideline principle that should be followed is a serious concurrent engineering approach for down selecting space-qualified microprocessors. This requires that the design engineer seek the support of a radiation effects expert who understands total ionizing dose (TID) and single-event effects (SEEs) issues for microprocessors as applied to the system in question.

Irom, Farokh↗

Radiation tests of highly scaled high density commercial nonvolatile NAND flash memories update 2009

Heavy ion single-event measurements on a variety of high density commercial NAND flash memories are reported. Three single event effect (SEE) phenomena are examined: single effect upsets (SEUs), single event functional interrupts (SEFIs), and catastrophic loss of ability to erase and program the device. Also, radiation results of multilevel flash technology are compared with results from single-level flash technology. These commercial high density memories appear to be much less susceptible to SEE and have better TID response compared to older generations of flash memories. The single-level devices are less sensitive to SEUs than multi-level devices. The charge pump in this study survived up to 600 krads. A new high current phenomenon in high density NAND flash memories is also discussed.

Nguyen, Duc N.↗

Radiation tests of highly scaled, high-density, commercial, nonvolatile NAND flash memories— update 2012

The space radiation environment poses a certain risk to all electronic components on Earth-orbiting and planetary mission spacecraft. In recent years, there has been increased interest in the use of high-density, commercial, nonvolatile flash memories in space because of ever-increasing data volumes and strict power requirements. They are used in a wide variety of spacecraft subsystems. At one end of the spectrum, flash memories are used to store small amounts of mission-critical data such as boot code or configuration files and, at the other end, they are used to construct multi-gigabyte data recorders that record mission science data. This report examines single-event effect (SEE) and total ionizing dose (TID) response in single-level cell (SLC) 32-Gb, multi-level cell (MLC) 64-Gb, and Triple-level (TLC) 64-Gb NAND flash memories manufactured by Micron Technology with feature size of 25 nm.

Allen, Gregory R.↗

High Density Packaging Technologies for RF Electronics in Small Spacecraft

This paper will describe a few high density packaging technologies which we are currently exploring for use in current and future small spacecraft applications. The three categories of technologies include organic multichip modules (MCMs), ceramic leadless surface mount technology (SMT) and 3D printed waveguide structures. There are many other packaging technologies that currently exist but these three were selected in part due to their long heritage in various commercial, military and space applications along with each having a relatively clear path to flight. For each of these technologies, detailed examples will be included in which hardware has been fabricated and tested for use in RF electronics for spacecraft transponders. The organic MCM example will be described in most detail and it utilizes a packaging technology by the name of CoreEZ which is a trademark of i3 Electronics. This MCM has shrunk a portion of our electronics down to 1/8th of its previous area. The CoreEZ technology has been shown to be rad hard beyond a total ionizing dose (TID) of 300kRad and the MCM which was fabricated has gone through thermal cycling and shown to have no degradation in performance. The ceramic leadless package examples include packages from high reliability manufactures by the name of KCB solutions and Barry Industries. In the case of KCB solutions, we have multiple products that will be described including a hermetic ceramic carrier which houses three microwave monolithic integrated circuits (MMICs) along with small discrete components. Finally, we will discuss the results of our search for a 3D printing process that allows us to reduce the cost and volume of our waveguide filters and diplexers for low cost small satellite applications. We have fabricated a few prototypes using direct metal laser sintering (DMLS) and metal coated plastics. Each of these packaging technology discussions will have a brief overview of its current and future use.

Schatzel, Donald↗

Characterization of the Teledyne CHROMA HgCdTe Detector for Imaging Spectrometers

Imaging spectroscopy places high demands upon detector performance. The dynamic range, linearity, and sensitivity must be maintained at high frame rates, and artifacts must be minimized across large focal plane array (FPA) formats. In this contribution, we discuss the Teledyne CHROMA HgCdTe FPA in the context of imaging spectrometer applications. The FPA was characterized in a laboratory thermal-vacuum chamber that allowed the read noise, dark current, well capacity, linearity, and crosstalk to be measured. Results are presented across a range of operating temperatures and pixel clock rates. Additionally, the outcomes of radiation testing to 100 krad TID are discussed. The results of these characterizations are critical to the designs and performance predictions of future imaging spectrometers utilizing the HgCdTe CHROMA FPA.

Green, Robert↗

Options for Radiation Tolerant High-Performance Memory

Memory technologies were reviewed for radiation effects performance in order to determine the most cost-efficient target for a possible memory investment targeted at creating a memory component of general applicability for space use. TID and SEL trends that had indicated improvement in intrinsic performance based on scaling cannot be trusted. SEE hardening of memory arrays is prohibitive in terms of cell-level power and area requirements. Radiation-hardened cells and custom controllers are recommended for future memory developments.

Some, Raphael↗

Iris Deep-Space Transponder for SLS EM-1 CubeSat Missions

Several key design upgrades have been recently made to the Iris Deep-Space Transponder baselined to be used on secondary payload missions of the upcoming Space Launch System Exploration Mission One (SLS EM-1). The Iris Transponder is a reconfigurable software-defined radio (SDR) designed for missions requiring interoperability with NASA's Deep Space Network (DSN) on X-band frequencies (7.2 GHz uplink, 8.4 GHz downlink). The transponder provides radiometric tracking support with the DSN to provide navigational products for precise orbit determination while performing standard uplink and downlink communications in a CubeSat/SmallSat-applicable package size. The recent hardware changes include a volume reduction of 30% from previous models, with the main transponder unit weighing less than 1.0 kg, while maintaining total ionizing dose (TID) radiation tolerance of >23 krads (Si) for deep-space missions. Lab tests indicate maximum downlink rates of up to 6.25 Msps can be supported by the transponder in conventional BPSK modulation, but most SLS EM-1 CubeSat missions are link-performance limited to less than 256 kbps. A prototype unit of the flight production units has been assembled and various performance and characterization tests are underway. This talk discusses the key design aspects and specifications of the Iris Transponder and presents preliminary results from early testing of the assembled transponder.

Kobayashi, M. Michael↗

Linear Systems LSK389 and LSK489 Dual N-Channel JFET Amplifier Total Ionizing Dose and Single-Event Effects Test Report

The purpose of these tests was to characterize the susceptibility of the LSK389 and LSK489 Dual N-Channel JFET from Linear Systems to Single-Event Latchup due to heavy ions and to Total Ionizing Dose (TID) degradation at -65 °C and intermediate dose rate. The test was carried out to assess suitability of the amplifiers for the Ocean Color instrument (OCI) on the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) spacecraft.

Ray Ladbury↗