Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THROTTLING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Layer-structured triple-conducting electrocatalyst for water-splitting in protonic ceramic electrolysis cells: Conductivities vs. activity

Electron, proton and oxygen-triple-conducting materials are becoming the dominant steam electrode candidate to break the rate limit on the water-splitting reaction that throttles the performance of protonic ceramic electrolysis cells (PCECs). In this study, based on Pr 2 NiO 4+δ Ruddlesden-Popper phase, we manipulate these conductivities by Pr-site Ba substitution to probe the correlation of each conductivity with the kinetics of the elementary reaction steps. It is found that the proton conductivity is vital to sustain an extended active surface area for faster adsorption of reactants and desorption of products. The effect of oxygen conductivity is surprisingly found insignificant in the water-splitting reaction. On the contrary, surface oxygen removal is discovered as the most rate-limiting process. The electronic conductivity is not a direct limiting factor. However, an electron transfer process between the current collector and the electrode junction could introduce extra resistance that is perceptible at a high operating temperature range. The best water-splitting activity is obtained on a proton conductivity/oxygen surface desorption capability well-balanced sample after Ba substitution. As a result, a water-splitting reaction resistance of 0.022 Ωcm 2 , a current density of 1.96 A/cm 2 at 700 °C is achieved on Pr 1.7 Ba 0.3 NiO 4+δ , one of the best performances for PCECs.

25 ENERGY STORAGE↗

Assessing the impact of substrate-level enzyme regulations limiting ethanol titer in Clostridium thermocellum using a core kinetic model

Clostridium thermocellum is a promising candidate for consolidated bioprocessing because it can directly ferment cellulose to ethanol. Despite significant efforts, achieved yields and titers fall below industrially relevant targets. This implies that there still exist unknown enzymatic, regulatory, and/or possibly thermodynamic bottlenecks that can throttle back metabolic flow. By (i) elucidating internal metabolic fluxes in wild-type C. thermocellum grown on cellobiose via 13 C-metabolic flux analysis ( 13 C-MFA), (ii) parameterizing a core kinetic model, and (iii) subsequently deploying an ensemble-docking workflow for discovering substrate-level regulations, this paper aims to reveal some of these factors and expand our knowledgebase governing C. thermocellum metabolism. Generated 13 C labeling data were used with 13 C-MFA to generate a wild-type flux distribution for the metabolic network. Notably, flux elucidation through MFA alluded to serine generation via the mercaptopyruvate pathway. Using the elucidated flux distributions in conjunction with batch fermentation process yield data for various mutant strains, we constructed a kinetic model of C. thermocellum core metabolism (i.e. k-ctherm138). Subsequently, we used the parameterized kinetic model to explore the effect of removing substrate-level regulations on ethanol yield and titer. Upon exploring all possible simultaneous (up to four) regulation removals we identified combinations that lead to many-fold model predicted improvement in ethanol titer. In addition, by coupling a systematic method for identifying putative competitive inhibitory mechanisms using K-FIT kinetic parameterization with the ensemble-docking workflow, we flagged 67 putative substrate-level inhibition mechanisms across central carbon metabolism supported by both kinetic formalism and docking analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Operational Modes of a 2.0 MWth Chloride Molten-Salt Pilot-Scale System

The limit of traditional solar-salt thermal stability is around 600 °C with ambient air as the cover gas. Nitrate molten salt concentrating solar power (CSP) systems are currently deployed globally and are considered to be state-of the art heat transfer fluids (HTFs) for present day high-temperature operation. However, decomposition challenges occur with these salts for operation beyond 600 C. Although slightly higher limits may be possible with solar salt, to fully realize SunShot efficiency goals of $15/kWhth HTFs and an LCOE of 6¢/kWh, molten-salt technologies working at higher temperatures (e.g., 650 °C to 750 °C) will require an alternative salt chemistry composition, such as chlorides. In this investigation a 2.0MWth Pilot-scale CSP plant design is developed to assess thermodynamic performance potential for operation up to 720 C. Here, an Engineering Equation Solver (EES) model is developed with respect to 14 state-points from the base of a solar tower at the Sandia National Laboratories, National Solar Thermal Test Facility (NSTTF), to solar receiver mounted 120 ft. above the ground. The system design considers a ternary chloride ternary chloride (20%NaCl/40%MgCl/40%KCl by mol%) salt as the HTF, with 6 hrs. of storage and a 1 MWth primary salt to sCO2 heat exchanger. Preliminary system modelling results indicate a minimum non-dimensional Cv of 60 required for both cold and hot-side throttle recirculation valves for the operational pump operating between speeds of 1800 and 2400 RPM. Further receiver comparison study results suggest that the ternary salt requires an average 15.2% higher receiver flux with a slightly lower calculated receiver efficiency when compared to a binary carnelite salt to achieve a 2.0 MWth desired input power design.

associated liquids↗

X-ray phase contrast and absorption imaging for the quantification of transient cavitation in high-speed nozzle flows

In this work, high-flux synchrotron radiation has been employed in a time-resolved manner to characterise the distinct topology features and dynamics of different cavitation regimes arising in a throttle orifice with an abrupt flow-entry contraction. Radiographs obtained though both X-ray phase- contrast and absorption imaging have been captured at 67,890 frames per second. The flow lied in the turbulent regime (Re=35,500), while moderate (CN=2.0) to well-established (CN=6.0) cavitation conditions were examined encompassing the cloud and vortical cavitation regimes with pertinent transient features, such as cloud-cavity shedding. X-ray Phase-Contrast Imaging (XPCI), exploiting the shift in the X-ray wave phase during interactions with matter, offers sharp-refractive index gradients in the interface region. Hence, it is suitable for capturing fine morphological fluctuations of transient cavitation structures. Nevertheless, the technique cannot provide information on the quantity of vapour within the orifice. Such data have been obtained utilising absorption imaging, where beam attenuation is not associated with scattering and refraction events, and hence can be explicitly correlated with the projected vapour thickness in line-of-sight measurements. A combination of the two methods is proposed, as it has been found is capable of quantifying the vapour content arising in the complex nozzle flow, while also faithfully illustrating the dynamics of the highly-transient cavitation features.

42 ENGINEERING↗

SQUARE: Strategic Quantum Ancilla Reuse for Modular Quantum Programs via Cost-Effective Uncomputation

Compiling high-level quantum programs to machines that are size constrained (i.e. limited number of quantum bits) and time constrained (i.e. limited number of quantum operations) is challenging. In this paper, we present SQUARE (Strategic QUantum Ancilla REuse), a compilation infrastructure that tackles allocation and reclamation of scratch qubits (called ancilla) in modular quantum programs. At its core, SQUARE strategically performs uncomputation to create opportunities for qubit reuse. Current Noisy Intermediate-Scale Quantum (NISQ) computers and forward-looking Fault-Tolerant (FT) quantum computers have fundamentally different constraints such as data locality, instruction parallelism, and communication overhead. Our heuristic-based ancilla-reuse algorithm balances these considerations and fits computations into resource-constrained NISQ or FT quantum machines, throttling parallelism when necessary. To precisely capture the workload of a program, we propose an improved metric, the "active quantum volume," and use this metric to evaluate the effectiveness of our algorithm. Furthermore, our results show that SQUARE improves the average success rate of NISQ applications by 1.47X. Surprisingly, the additional gates for uncomputation create ancilla with better locality, and result in substantially fewer swap gates and less gate noise overall. SQUARE also achieves an average reduction of 1.5X (and up to 9.6X) in active quantum volume for FT machines.

compiler optimization↗

Design and Optimization of a Fast-Switching Electromagnetic Valve Actuator for Off-highway Vehicle Hydraulic Systems

Electrification of off-highway vehicles offers improved efficiency and reduction in greenhouse gas emissions. However, the extremely low power densities of electric machines relative to the hydraulics used in conventional off-highway vehicles makes electrification challenging. Although the recently proposed Hybrid Hydraulic Electric Architecture (HHEA) can overcome this limitation, it requires frequent switching between the pressure rails using switching valves resulting in losses. Fast switching minimizes the switching losses in these valves, which otherwise significantly reduce the overall efficiency of the system. The primary contribution of this paper is the design and optimization of a linear electromagnetic actuator for a fast-switching valve. This paper identifies the actuator requirements to enable fast switching and presents a design and optimization technique to realize actuators that meet the design objectives. In addition, a multi-physics approach is proposed to model the performance of the complete switching valve by considering the electromagnetic, fluidic, and mechanical physics. An optimal actuator design is obtained using the developed optimization framework, and the multi-physics model demonstrates that the selected design achieves a 30% reduction in throttling-related switching losses by switching 70 % faster than comparable commercial valve designs.

Linear actuators, off-highway vehicle electrificat↗

Optimal Control of the Energy-Saving Hybrid Hydraulic-Electric Architecture (HHEA) for Off-Highway Mobile Machines

Most off-highway constructions and agriculture equipment use hydraulics, which has unmatched power density, for power transmission and throttling as a means for control. A novel hybrid hydraulic-electric architecture (HHEA) has recently been proposed to improve efficiency for high-power machines that would have been cost-prohibitive to electrify directly. HHEA uses a set of common pressure rails (CPRs) to transmit the majority of power hydraulically and small electric motor drives to modulate that power and to achieve precise control. This article proposes a computationally efficient Lagrange multiplier method (LMM) for computing the optimal sequence of pressure rail selections to minimize energy use. This is needed to evaluate HHEA's energy-saving potential and for iterative architecture design and sizing. An interesting complication is that the cost function is not fully defined until the candidate control sequence is fully specified. This issue is dealt with by decomposing the original problem into a set of sub-problems with additional constraints that can be solved efficiently. Computational effort can be further reduced if actuators are optimized individually instead of together. However, additional steps are required to prevent the constraint functions from becoming discontinuous with respect to the Lagrange multipliers, which is necessary for meeting the constraints. Lastly, a case study of a construction machine demonstrates the efficacy of the method and shows that the HHEA reduces energy consumption by 68%-73% compared to the baseline load-sensing architecture.

Lagrange multiplier↗

Cell-Edge Detection via Selective Cooperation and Generalized Canonical Correlation

Improving the uplink quality of service for users located around the boundaries between cells is a key challenge in cellular systems. Existing approaches relying on power control throttle the rates of cell-center users, while multi-user detection requires accurate channel estimates for the cell-edge users, which is another challenge due to their low received signal-to-noise ratio (SNR). Utilizing the fact that cell-edge user signals are weak but common (received at roughly equal power) at different base stations (BSs), this paper establishes a connection between cell-edge user detection and generalized canonical correlation analysis (GCCA). It puts forth a GCCA-based method that leverages selective BS cooperation to recover the cell-edge user signal subspace even at low SNR. The cell-edge user signals can then be extracted from the resulting mixture via algebraic signal processing techniques. The paper includes theoretical analysis showing why GCCA recovers the correct subspace containing the cell-edge user signals under mild conditions. The proposed method can also identify the number of cell-edge users in the system, i.e., the common subspace dimension. Simulations reveal significant performance improvement relative to various multiuser detection techniques. Cell-edge detection performance is further studied as a function of how many / which BSs are selected, and it is shown that using the closest three BS is always the best choice.

base station cooperation↗

Investigations into EGR dilution tolerance in a pre-chamber ignited GDI engine

EGR is a useful means to improve fuel economy in spark-ignited gasoline engines, especially under part-load conditions by means of reducing throttling losses. There is also a significant reduction in NOx emissions due to the reduced peak cylinder temperatures. However, the ability of conventional spark ignition systems to reliably ignite dilute mixtures limits the dilution tolerance due to the onset of combustion instability. In this study, an active pre-chamber system was evaluated at part load condition with various EGR rates using a regular grade full boiling range gasoline. A premixed air-fuel mixture was supplied to the pre-chamber, which assists in scavenging the residual mass fractions to enable reliable ignition of EGR dilute mixtures in the main combustion chamber. A range of pre-chamber injection, air-fuel mixture formulation, and ignition timing strategies were evaluated during the EGR sweeps. In addition, 0-D and 1-D simulations were conducted in GT-Power to assess the thermodynamic state and composition in the pre-chamber, as well as estimate the jet momentum at the various dilution rates. The active pre-chamber extended the EGR dilution limit from 20% for conventional SI to above 30%, with a higher pre-chamber flow rate (more scavenging) resulting in increased combustion stability. A tradeoff between the jet momentum and spark timing was observed when analyzing the GT-Power simulations and the pre-chamber jet momentum was found to decrease with increasing EGR rate. At unstable high EGR operation, no relation could be found between the pre-chamber indicated data and main chamber combustion stability.

33 ADVANCED PROPULSION SYSTEMS↗

The influence of intake flow and coolant temperature on gasoline spray morphology during early-injection DISI engine operation

Multi-hole gasoline injectors operating at conditions spanning throttled early-intake stroke operation produce spray plumes that either remained separated or merge and collapse due to flash boiling. Flash boiling occurs due to the sudden expansion of gas bubbles in the liquid fuel at high fuel temperature and low ambient pressure. This study records high-speed images of spray-morphology changes due to in-cylinder flow, thereby revealing operating conditions that do and do not affect the self-induced morphology observed in quiescent vessels. Specifically, in a central-injection, four-valve, high-tumble engine, where the thermodynamic state and in-cylinder cross flow are dynamic. Motivated by cold start and hot restart operation, the fuel pressure, coolant temperature, in-cylinder air pressure, and engine rpm were systematically varied over relevant operating conditions, which bracketed the range from non- to flash-boiling sprays. The results reveal the operating conditions at which the in-cylinder cross flow disrupts the spray morphology as well as the extent of the disruption. At 650 rpm, the spray morphology was similar to that observed in quiescent vessels at nominally equivalent fuel temperature and in-cylinder pressure, indicating that the spray’s self-induced entrainment flow dominated the in-cylinder flow. However, for fuel temperature and ambient pressure near the transition between non- and flash-boiling, the intake cross flow at higher engine speed (1950 rpm) significantly disrupted the spray morphology. The high cross-flow velocity appears to induce plume merging and collapse, whereas none was evident at low rpm (650 rpm). This study led to the postulate that the spray merging and collapse are governed by the rate of atomization near the nozzle exit, presumed to be controlled by either or both aerodynamic atomization and flash-boiling intensity. It would then follow that spray modeling in CFD requires atomization models that blend the effects of both physical processes.

42 ENGINEERING↗

Physically-based control-oriented modeling for turbocharged stoichiometric spark-ignited engine with cooled EGR and flexible VVT systems

Accurate estimation and prediction of engine gas exchange system and in-cylinder conditions are critical for spark-ignited engine control and diagnostic algorithm development. In this paper, a physically-based, control-oriented model for a 2.8 l turbocharged, variable valve timing (VVT) and low pressure (LP) exhaust gas recirculation (EGR)-utilizing SI engine was developed. The model includes the impact of modulation to any combination of 10 actuators, including the throttle valve, compressor bypass valve, fueling rate, waste-gate, LP EGR valve, number of deactivated cylinders, intake valve open (IVO) timing, intake valve close (IVC) timing, exhaust valve open (EVO) timing and exhaust valve close (EVC) timing. The accuracy of the model in capturing engine dynamics was demonstrated by validating it against high-fidelity engine GT-Power simulation results for various drive cycles, particularly emphasizing elevated loads. In comparison to the open literature, novel contributions of the effort described in this paper includes in-cylinder gas composition modeling and turbine-out pressure estimation.

Zhang, Xu↗

High BMEP and High Efficiency Micro-Pilot Ignition Natural Gas Engine (Final Project Report)

The project objectives were to develop demonstrate a high-efficiency high-output natural gas diesel micro-pilot stoichiometric engine operating with diesel pilot contribution of less than 5% on a medium duty engine. The program’s outcomes achieve in a partnership between Michigan Technological University and Westport Power Inc. were very successful. The engine platform was a 6.7L I6 engine with a compression ratio of 15:1 and achieved 24 bar BMEP and 41% brake thermal efficiency at lambda. Simulation and modeling with an improved turbocharger and combustion chamber improvements demonstrated a clear path to 43% BTE. The operational stoichiometric range was from 5 to 24 bar with minimal throttling. Diesel contribution over the cycle was 4.6%. The results achieved in this program are well above the best in-class baseline natural gas spark ignition engines of 19.5 bar BMEP and 40% BTE.

33 ADVANCED PROPULSION SYSTEMS↗

Integrated Optimization and Control of a Hybrid Gas Turbine/sCO 2 Power System

During phase-I, the project team led by Echogen Power Systems (EPS) had two primary objectives based on investigating the application of gas turbines with supercritical carbon dioxide (sCO 2 ) power cycles. The first objective was to improve the overall efficiency and performance of a hybrid gas turbine/sCO 2 power system through a joint optimization of the two subsystems (gas turbine and sCO 2 power cycle) using non-linear optimization techniques that simultaneously evaluate thermal performance of the combined cycle. The hybrid power system included several points of interaction, including (but not limited to) gas turbine exhaust, fuel heating, inlet chilling and turbine cooling. The second objective was to establish a baseline transient response model of the hybrid power system and a notional microgrid and begin steps to integrate the control systems of the three major elements (gas turbine, sCO 2 cycle and grid controller). The project team established a baseline performance for a combined cycle power plant using a production gas turbine and scaled sCO 2 power cycle only utilizing exhaust heat recovery. Echogen’s non-linear techno-economic optimization code was extended by adding gas turbine component models derived from a in-house developed gas turbine design code. With the two cycles coupled by the gas turbine exhaust, design parameters of both cycles were allowed to vary simultaneously to determine performance opportunity versus isolated designs. Returning to the baseline gas turbine/sCO 2 power cycle transient models: Echogen had in-house developed sCO 2 cycle transient model in GT-Suite system simulation software, and had partnered with Siemens Finspång for gas turbine transient model, and Siemens PTI group to provide micro-grid load profile as well as hybrid power cycle generated load (power and frequency) analysis. The transient model for the SGT-750 Siemens gas turbine was a “black-box” functional mock-up interface (FMI) model developed by Siemens Industrial Turbomachinery in Finspång, Sweden. The SGT-750 is a twin-shaft gas turbine that produces 40 MW electricity with an efficiency of about 40% at ISO conditions. At 100% gas turbine throttle (load), the SGT-750 has average exhaust conditions of 114.6 kg/s and 469.8°C. The transient model for sCO 2 power cycle was developed by Echogen in GT-SUITE 1D system simulation software platform. The basic CO 2 flow circuit has single-shaft turbomachinery with net 11.5 MW electrical power output at design conditions. The power turbine has a double-ended shaft with one end connected to synchronous generator through a fixed-ratio gearbox. The other end of power turbine is connected to the compressor through a continuously variable transmission. The major components of the sCO 2 power cycle modeled include air cooled condenser/cooler, CO 2 compressor, recuperator, two waste heat exchanger coils, power turbine, continuous variable transmission, gearbox and generator. Integration of SGT-750 transient model and sCO 2 power cycle transient model was done in Matlab Simulink. In the integrated model, the gas turbine and sCO 2 power cycle interacted at two points, first one being the gas turbine exhaust gas flow rate and temperature, which were inputs to sCO 2 power cycle model. The second point was the distribution of micro-grid load demand signal between the SGT-750 generator and sCO 2 cycle generator. For a given combined-cycle load demand, the gas turbine load demand was equal to the total demand minus the sCO 2 cycle power generated. In the present study the integrated model was simulated for two cases of grid load demand: (i) for a step change, both positive-step and negative-step, in grid load demand (ii) for a micro-grid load demand curve provided by Siemens PTI group. Finally, the time series plots representing load demand versus integrated system response were presented including the sCO 2 power cycle control system performance plots. The actual generated power and frequency of both the generators, gas turbine and sCO 2 power cycle, was supplied to Siemens PTI group for dynamic grid assessment, results of which are provided in appendices.

03 NATURAL GAS↗

Connecting the Radiative Influences of Aerosol upon the Mass Flux Profiles of Shallow Cumuli across the Southeast Atlantic Ocean Basin and its Boundaries (Final Report)

The Atlantic Ocean covers approximately 25% of Earth’s surface and the atmosphere above it is home to a complex array of clouds and aerosols that have important influences on regional and global weather and climate. These influences must be accurately depicted in short range, medium range, seasonal, and climate forecast models. Conditions over the tropical Atlantic are particularly complex due to continental scale plumes of dust from the Sahara Desert and smoke from agricultural burning in Africa that drift across the Atlantic Ocean basin toward the Americas. These plumes are often found meandering in the lower atmosphere above shallow tropical clouds that form above the ocean surface, presumably mingling with these clouds on occasion due to convective mixing processes. Elevated dust and smoke particles absorb incoming sunlight and substantially warm the marine atmosphere in the layer in which they are present. This warming may alter the thermal stability of the marine atmosphere and may throttle or enhance the development of clouds, change their internal structure and the rate at which they precipitate. Alternatively, it may isolate the lower atmosphere from drier layers above enabling water vapor to accumulate near the ocean surface potentially leading to the development of deeper convection. Our study was organized around the principal concept of determining the impact of African smoke and dust plumes upon cloud development at ASI and understanding how a popular shallow convection parameterization used in models responds to the presence of this aerosol. We analyzed observations collected during the US Department of Energy (DOE) Layered Atlantic Smoke Interactions with Clouds (LASIC) campaign using the Atmospheric Radiation Measurement Program’s Mobile Facility #1 (AMF-1), which was deployed to Ascension Island (ASI) in Southeastern Atlantic for a one-year period. Ascension Island is immediately downwind from an African source of these plumes, but far enough removed to enable the lower atmosphere to have reacted to their presence. A main goal of our study was to compute radiative heating rate profiles over Ascension Island and along the trajectory from the biomass burning regions along coastal Africa to Ascension Island. To compute the radiative heating rate due to aerosols and clouds, we employed observed profiles of temperature, humidity, and clouds from LASIC alongside aerosol optical properties from the Modern-era Retrospective analysis for Research and Applications Version 2 (MERRA-2), as input for the Rapid Radiation Transfer Model (RRTM). Radiative heating was also assessed across the southeast Atlantic Ocean using an ensemble of back trajectories from the Hybrid Single Particle Lagrangian Integrated Trajectory (HYSPLIT) model. We were successful in this effort and the resulting publication is already being cited despite its relatively short lifetime in the literature. The second part of our study involved the process-level representation of the clouds observed over the Southeastern Atlantic in models. Our initial task, upon which the balance of this portion of the study depended, was to evaluate the representativeness of the clouds observed by AMF-1. What orographic influence did Ascension Island have on the measured cloud structure? We set out to answer this question by trying to separate observations that were clearly indicative of orographic forcing from those that were representative of open ocean. The siting of AMF-1, which was 340-m above sea-level on the slope of a steep escarpment, proved demonstrably problematic for cloud process measurements. Despite considerable effort using multiple approaches including artificial intelligence (AI), we were unable to successfully compensate for the orographic forcing present at the AMF-1 site on ASI and, hence, produce process-level summaries of the convective mass flux representative of open ocean over the Southeastern Atlantic. Even though the project has officially ended, we are making a final attempt using two new types of clustering algorithm (i.e., AI) on the recommendation of a former student, who is an expert in this area. Since we have only recently begun to test these new AI schemes, the recommendations from the second part of our project outlined below are based on our experience at the time of this report.

54 ENVIRONMENTAL SCIENCES↗

FY22 Progress on Computational Modeling of the Water-Based NSTF

This report summarizes the system-level modeling effort by Argonne National Laboratory (Argonne) of the Natural convection Shutdown heat removal Test Facility (NSTF) in FY22. As an extension of the effort from FY21, this year’s work focuses primarily on the two-phase modeling of the NSTF using RELAP5-3D, particularly with the inclusion of the cavity model. The results from simulations were used to compare against experimental data for benchmarking purposes of the RELAP5 deck. Additionally, RELAP5 was used as a predictive tool to guide planned test operations and identify expected system behaviors. In the first part of this report, details are provided of the cavity omitted model where heat flux is applied directly as a boundary condition to the risers. The general trend predicted by the RELAP5 model matches that from the experimental data when a single-phase natural circulation flow is first established, followed by an oscillatory two-phase period and finally a stable two-phase flow. However, the onset of oscillations is predicted early by the model due to the smaller thermal mixing region in the tank. However, by expanding the simulated thermal mixing region in the tank, the onset of oscillations predicted by the model is able to match that from the experiment. These oscillations where studied in depth and are deduced to be flashing-induced instability. The model was then modified to simulate an accident scenario case where a representative heat load based on the full-scale Framatome’s 625 MW t SC-HTGR was applied directly to the riser channels. The simulated initial and boundary conditions were identical to those performed experimentally, facilitating direct comparisons between the predicted and experimental results. It was determined that the results showed some discrepancies remain, likely due to the overprediction of vapor generation rate by the computer model. In the second part of this report, the cavity model is re-introduced where it is observed that the RELAP5 prediction is now able to capture the major trends of the observed flow commonly observed during two-phase conditions. However, the onset of oscillations is once again predicted early by the model, possibly caused by the underprediction of heat loss from the heater and cavity. This is likely due to the omission of support structures in the cavity that can act as additional pathways for heat to escape to the environment. To overcome the underprediction of heat loss, part of the insulation surrounding the cavity side panels and the back of the heaters are removed to allow heat to escape directly to the environment, which then improves the RELAP5 prediction. Parametric studies are also performed to investigate the effects of heater power, tank inventory level, and tank gas space pressure on flow behaviors, also in direct comparison to conditions tested experimentally. User option-61 in the RELAP5-3D input deck, which changes the heat transfer coefficient correlations used for calculating the vapor generation, is also investigated where it is found that by enabling the option, the overall duration of oscillations is increased and matches that from the experiment better. The RELAP5 model is further benchmarked with a header inlet- throttling case where it is observed that the prediction from the model fails to capture some major features observed in the experiment. By using a modified loss coefficient curve for the valve, the accuracy of the prediction is improved where most of the major features observed in the experiment are predicted by the model. Lastly, the model is benchmarked with an inventory depletion scenario where it is observed that despite the modeling limitation of RELAP5, the prediction shows good agreement with the experimental data where major trends and features are captured by the model. Future work will see continued development of the current RELAP5-3D input deck of the NSTF to both improve the accuracy of the model’s predictive capability and continuing serving the experimental program. The mutually beneficial relationship between analysis and experimental efforts has become integral to the parent NSTF program, and the greater objective to fully understand and accurately predict the heat removal performance of a full scale RCCS concept.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Bio-fuel effects and seasonal fuel property variations related to abnormal combustion occurrences observed in the field

Since 2015, the automotive industry has regularly observed sharp increases in customer complaints of poor driveability and increased warranty claims during the months of September and October. These persistent seasonal complaint increases have been tracked to occur from increased abnormal combustion events that coincide with the seasonal transition from summer to winter fuel volatility, beginning on September 15th annually. The Reid Vapor Pressure (RVP) of gasoline during this seasonal transition has been found to be the primary property attributed to this annual issue. It’s hypothesized that an increase in volatile butanes and pentanes from advanced petroleum recovery techniques and hydrofracking production has hastened the transition from summer to winter fuel volatility in the marketplace, rather than the gradual increase of the RVP over time as historically intended. At worst, mid-winter fuel, with an RVP ranging from 12 to 16 psi, depending on location in the U.S., enters the market while ambient temperatures can still be above average for the winter season. This combination of high volatility fuel with unseasonably warm weather will increase fuel system flash boiling, injector spray cavitation, and spray collapse inside the engine’s combustion chamber, ultimately linking fuel property variations to abnormal engine combustion processes. This CRADA program will investigate these known knowledge gaps by coupling with two national laboratories, Oak Ridge National Laboratory, and the National Renewable Energy Laboratory to employ both unique tools and expertise throughout the industry to provide the insight, knowledge, and data critical to understand the observed interactions. Overall findings of this work are that fuel wall retention increased SPI proportionally, and fuels with an increased distillation (i.e. energy fraction) above the wall temperature increased fuel retention. Likewise fuels with increased enthalpy of vaporization (HoV) increased fuel retention proportional to the temperature reduction from the HoV (~13K reduction in this work). Thus, fuel with increased HoV and increased fuel distillation above the linear temperature also exhibited increased SPI rates. Fuel with high RVP did exhibit increased fuel spray collapse form spray imaging measurements, but in SPI testing the high volatility of these fuels at the tested conditions did not necessarily increase SPI rates despite exhibiting increased spray collapse in injector imaging and increased spray-wall impingement measured in fired engine testing. It was also found that spray imaging showed collapse was possible at throttled conditions, but this was not relevant to high boost pressures relevant to SPI conditions, however, under transient load and or speed encountered in real-world operation fuel spray collapse could affect fuel retention and real-world SPI that were not probed in the automated high load test sequence of this work.

09 BIOMASS FUELS↗

JIRIAF: JLAB Integrated Research Infrastructure Acros Facilities

The JIRIAF project aims to combine geographically diverse computing facilities into an integrated science infrastructure. This project starts by dynamically evaluating temporarily unallocated or idled compute resources from multiple providers. These resources are integrated to handle additional workloads without affecting local running jobs. This paper describes our approach to launch best-effort batch tasks which exploit these underutilized resources. Our system measures the real-time behavior of jobs running on a machine and learns to distinguish typical performance from outliers. Unsupervised ML techniques are used to analyze hardware-level performance measures, followed by a real-time cross-correlation analysis to determine which applications cause performance degradation. We then ameliorate bad behavior by throttling these processes. We demonstrate that problematic performance interference can be detected and acted on, which makes it possible to continue to share resources between applications and simultaneously maintain high utilization levels in a computing cluster. We relocate the CLAS12 data processing workflow to a remote data center for a case study, preventing file migration and temporal data persistency.

Lawrence, David↗

Modifications to Solar Titan-130 Combustion Systems for Efficient, High Turndown Operation

The project team of Southwest Research Institute® (SwRI®), Solar Turbines Incorporated (Solar), the Electric Power Research Institute (EPRI), the University of California, Irvine (UCI), and the Georgia Institute of Technology (Georgia Tech) investigated methods to allow higher efficiency part-load operation of a Solar Titan 130 gas turbine. The objective was to develop a low-emission combustion system capable of sustaining combustion and avoiding lean blowout during high turndown operation, which would allow the gas turbine to operate as efficiently as possible at part load. Currently, electric utility markets are beginning to experience substantial increases in renewable energy generation. Some of these renewable energy sources have highly variable output in an uncontrolled manner. In order to maintain grid stability, there is a need for power plants to ramp up power to the grid rapidly to make up for drops in renewable generation. This is often termed spinning reserve, but the size of this reserve may need to increase as renewable penetration into the electric utility market increases. Small combined heat and power (CHP) power plants provide a promising option for meeting this spinning reserve requirement. In order to operate in spinning reserve while still meeting the heat requirements for the CHP, the gas turbine needs to operate efficiently at very low loads. Efficient, high turndown operations in this engine are limited by the lean flammability limit of the premixed combustion system. This project sought enhance the lean operability range of the Titan 130 combustor. First, the project team participated in a brainstorming activity and ultimately selected two concepts to explore: fuel augmentation with hydrogen (H2) to improve the stability at lean operating conditions and modifications to the fuel nozzle to improve the emissions performance at lean operating conditions. Analytical and laboratory investigations were accomplished by UCI to investigate the efficacy of H2 addition at improving lean blow out (LBO) limits and the resulting emissions. These investigations used a variety of chemical reactor network (CRN) and CFD models, validated against laboratory data, to model the impact of H 2 and inform the experimental efforts accomplished by SwRI and Solar. Ultimately, both the CRN and CFD models yielded generally good agreement with the experimental data below a particular temperature threshold. Atmospheric tests of a full-scale T130 annular combustor were performed at SwRI facilities in San Antonio, Texas, to investigate the use of H 2 addition. For these tests, the T130 combustion system remained largely unchanged; minor modifications were performed to the fuel ducting to allow for the safe use of H 2 . The test ultimately demonstrated that the addition of H 2 to the fuel mixture significantly increased the AFR ratio at which the combustor could operate. This improvement to the LBO limit should allow for less use of compressor bleed and less throttling needed by the inlet guide vanes (IGV). This in turn could result in more efficient operation of the gas turbine at lower load points. The second modification explored in this work was a direct modification to the T130 injector. The project team hypothesized that modifications to the pilot of the T130 injector could provide lower emissions at high turn-down operations. These modifications were manufactured and explored by the team at Solar. High pressure rig tests, originally slated to occur at SwRI, were ultimately accomplished by Solar to maintain overall project budget and mitigate cost growth attributable to supply chain issues and inflation. The pressurized rig tests ultimately showed that the SwRI Project No. 18.24153 - DE-EE0008415 Page 2 Final Technical Report January 24, 2024 modifications did not significantly alter the performance of the combustion system at the high turn-down conditions; both the modified injectors and the baseline configuration exhibited elevated emissions comparted to the full-load operating condition. A final set of studies performed by EPRI investigated the benefit-cost of flexible CHP as well as a grid interconnection study for the California Independent System Operator (CAISO) grid. These studies considered: traditional CHP with no spinning reserve available for on-demand grid support, 50% flexible CHP where 50% of the machine’s capacity is consumed by on-site baseload operations while providing an additional 50% capacity for on-demand grid support, and 70% flexible CHP where 70% of capacity is consumed on-site by baseload operations and 30% is available for on-demand grid support. In all cases, the analyses showed a benefit-to-cost ratio greater than unity implying a positive net present value for all configurations. However, the traditional CHP showed the most economic benefit. These results are sensitive to several factors, many of which are not fully known and may vary over time. Thus site owners must be convinced that taking up the increased costs and risks from flexible CHP would be worth implementing. As the grid in California and across the country transition to incorporate larger renewable energy generation, flexible CHP can provide much needed operating reserves and dispatchability. Alternative fuel options, such as hydrogen blending and biofuels, may also lower carbon intensities of CHP. Flexible CHP should be examined in the evolving market to understand innovative business models, changes market rules and services, and new technologies.

20 FOSSIL-FUELED POWER PLANTS↗