Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEMPERATURE PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Technique for temperature compensation of eddy-current proximity probes

Eddy-current proximity probes are used in turbomachinery evaluation testing and operation to measure distances, primarily vibration, deflection, or displacment of shafts, bearings and seals. Measurements of steady-state conditions made with standard eddy-current proximity probes are susceptible to error caused by temperature variations during normal operation of the component under investigation. Errors resulting from temperature effects for the specific probes used in this study were approximately 1.016 x 10 to the -3 mm/deg C over the temperature range of -252 to 100 C. This report examines temperature caused changes on the eddy-current proximity probe measurement system, establishes their origin, and discusses what may be done to minimize their effect on the output signal. In addition, recommendations are made for the installation and operation of the electronic components associated with an eddy-current proximity probe. Several techniques are described that provide active on-line error compensation for over 95 percent of the temperature effects.

Masters, Robert M.↗

Low-temperature oxidation pathways are critical to thermal incineration of PFAS-laden materials

With growing desire to destroy per- and poly-fluoroalkyl substances (PFAS) now known to be detrimental to human health, a sound understanding of fluorocarbon combustion chemistry is important to efficient thermal destruction within incinerators. While most fluorocarbon combustion models and the sets of reactions contained within them were originally developed for the high temperatures encountered in flame suppression applications, they have often been used to assess PFAS destruction in incinerators, which emphasize a lower range of temperatures. We present results that demonstrate that low-temperature fluorocarbon oxidation pathways—not yet known to play a role in fluorocarbon combustion—impact key incinerator performance metrics, including: PFAS surrogate mole fractions, products of incomplete destruction, and waste destruction efficiencies. The results further point to the utility of NO as a potential additive. The present results show the influence of these pathways for CF 3 O 2 , for which some data are available, but analogous pathways would also occur for other fluoroalkylperoxy radicals, for which little is known. Furthermore, the results demonstrate the need for future work to identify and characterize low-temperature pathways more generally, consider such pathways in kinetic model development, and experimentally probe intermediate temperature conditions to better understand, design, and control thermal destruction technologies for improved PFAS management.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cleavable quaternary oxychlorides with high magnetic ordering temperatures

Quaternary oxychlorides derived from Ruddlesden–Popper 3d transition metal oxides offer a route to cleavable crystals with bulk antiferromagnetic ordering temperatures reaching at least 550 K. Here, we study the magnetic, optical, and mechanical behavior of Sr 2 FeO 3 Cl, Ca 2 FeO 3 Cl, Ca 3 Fe 2 O 5 Cl 2 , and Sr 3 Fe 2 O 5 Cl 2 . Through optical absorption measurements, we show that these antiferromagnetic semiconductors have optical band gaps of ≈2.1(1) eV. The magnetic ordering symmetries and temperatures were probed by neutron powder diffraction and Mössbauer spectroscopy on polycrystalline samples, demonstrating Néel temperatures (T N ) near room temperature in the single layer Sr 2 FeO 3 Cl (T N ≈ 311 K) and Ca 2 FeO 3 Cl (T N ≈ 360 K), and the double-layer compound Sr 3 Fe 2 O 5 Cl 2 has T N ≈ 545 K. The high-spin moments of Fe 3+ lie within the basal plane and the magnetic structures are compensated within each magnetic layer and characterized by magnetic propagation vectors k = ($\frac{1}{2}$ $\frac{1}{2}$ 0). Magnetization results demonstrate the quasi-2D nature of the magnetism, with a broad maximum in the susceptibility near 2T N for Sr 2 FeO 3 Cl. Scotch tape tests and mechanical exfoliation onto SiO 2 confirm the micaceous nature of these crystals with cleavage down to a single unit cell (two magnetic layers) achieved for Sr 3 Fe 2 O 5 Cl 2 . In conclusion, this paper highlights strong antiferromagnetic interactions, semiconducting band gaps, and cleavability of quaternary Fe-based oxychlorides and motivates future work on crystals and exfoliated flakes of these and related oxyhalide systems.

36 MATERIALS SCIENCE↗

Evaluation of liquid-phase thermometry in impinging jet sprays using synchrotron x-ray scattering

Liquid thermometry during primary and secondary breakup of liquid sprays is challenging due to the presence of highly dynamic, optically complex flow features. This work evaluates the use of x-ray scattering from a focused, monochromatic beam of the Advanced Photon Source at Argonne National Laboratory for the measurement of liquid temperatures within the mixing zone of an impinging jet spray. The measured scattering profiles are converted to temperature through a previously developed two-component partial least squares (PLS) regression model. Transmitive mixing during jet merging is inferred through spatial mapping of temperatures within the impingement region. In this work, the technique exhibits uncertainties of ±2K in temperature and 2% in capturing the correct scattering profile, showing its potential utility for probing liquid temperature distributions in multiphase flows.

42 ENGINEERING↗

A statistical study of the subauroral electron temperature enhancement using dynamics Explorer 2 Langmuir probe observations

A statistical study of the subauroral electron temperature enhancement was undertaken using Langmuir probe observations during 488 traversals of the midlatitude plasmapause region by the DE-2 satellite. The subauroral electron temperature enhancement on the nightside is a quasi-permanent feature at all altitudes between 350 and 1000 km with an occurrence frequency that depends on altitude. The occurrence frequency of the subauroral electron temperature peak has a strong altitude dependence on the dayside. The position of the subauroral Te peak decreases with increasing magnetic activity in a manner similar to that of the equatorial plasmapause and other midlatitude plasmapause signatures.

Kozyra, J. U.↗

Temperature and pressure effects on capacitance probe cryogenic liquid level measurement accuracy

The inaccuracies of liquid nitrogen and liquid hydrogen level measurements by use of a coaxial capacitance probe were investigated as a function of fluid temperatures and pressures. Significant liquid level measurement errors were found to occur due to the changes in the fluids dielectric constants which develop over the operating temperature and pressure ranges of the cryogenic storage tanks. The level measurement inaccuracies can be reduced by using fluid dielectric correction factors based on measured fluid temperatures and pressures. The errors in the corrected liquid level measurements were estimated based on the reported calibration errors of the temperature and pressure measurement systems. Experimental liquid nitrogen (LN2) and liquid hydrogen (LH2) level measurements were obtained using the calibrated capacitance probe equations and also by the dielectric constant correction factor method. The liquid levels obtained by the capacitance probe for the two methods were compared with the liquid level estimated from the fluid temperature profiles. Results show that the dielectric constant corrected liquid levels agreed within 0.5 percent of the temperature profile estimated liquid level. The uncorrected dielectric constant capacitance liquid level measurements deviated from the temperature profile level by more than 5 percent. This paper identifies the magnitude of liquid level measurement error that can occur for LN2 and LH2 fluids due to temperature and pressure effects on the dielectric constants over the tank storage conditions from 5 to 40 psia. A method of reducing the level measurement errors by using dielectric constant correction factors based on fluid temperature and pressure measurements is derived. The improved accuracy by use of the correction factors is experimentally verified by comparing liquid levels derived from fluid temperature profiles.

Edwards, Lawrence G.↗

Method for determination of neutral atomic oxygen flux

A method for measuring atomic oxygen flux to a probe surface is presented which uses two probes. One is a glass probe enclosing a small ceramic resistor heater and a thermocouple for determining the ambient local temperature. Another probe has a silver tip and a thermocouple inside it. In an atomic oxygen environment, the silver probe will quickly develop a silver oxide coating which provides for atomic oxygen recombination. The use of the two probes allows a more accurate determination of the energy input into the catalytic silver oxide probe due to recombination.

Carruth, M. R., Jr.↗

Electronic clinical predictive thermometer using logarithm for temperature prediction

A thermometer that rapidly predicts body temperature based on the temperature signals received from a temperature sensing probe when it comes into contact with the body. The logarithms of the differences between the temperature signals in a selected time frame are determined. A line is fit through the logarithms and the slope of the line is used as a system time constant in predicting the final temperature of the body. The time constant in conjunction with predetermined additional constants are used to compute the predicted temperature. Data quality in the time frame is monitored and if unacceptable, a different time frame of temperature signals is selected for use in prediction. The processor switches to a monitor mode if data quality over a limited number of time frames is unacceptable. Determining the start time on which the measurement time frame for prediction is based is performed by summing the second derivatives of temperature signals over time frames. When the sum of second derivatives in a particular time frame exceeds a threshold, the start time is established.

Cambridge, Vivien J.↗

Acoustic Database for Turbofan Engine Core-Noise Sources: Volume - I

In this program, a database of dynamic temperature and dynamic pressure measurements were acquired inside the core of a TECH977 turbofan engine to support investigations of indirect combustion noise. Dynamic temperature and pressure measurements were recorded for engine gas dynamics up to temperatures of 3100 degrees Fahrenheit and transient responses as high as 1000 hertz. These measurements were made at the entrance of the high pressure turbine (HPT) and at the entrance and exit of the low pressure turbine (LPT). Measurements were made at two circumferential clocking positions. In the combustor and inter-turbine duct (ITD), measurements were made at two axial locations to enable the exploration of time delays. The dynamic temperature measurements were made using dual thin-wire thermocouple probes. The dynamic pressure measurements were made using semi-infinite probes. Prior to the engine test, a series of bench, oven, and combustor rig tests were conducted to characterize the performance of the dual wire temperature probes and to define and characterize the data acquisition systems. A measurement solution for acquiring dynamic temperature and pressure data on the engine was defined. A suite of hardware modifications were designed to incorporate the dynamic temperature and pressure instrumentation into the TECH977 engine. In particular, a probe actuation system was developed to protect the delicate temperature probes during engine startup and transients in order to maximize sensor life. A set of temperature probes was procured and the TECH977 engine was assembled with the suite of new and modified hardware. The engine was tested at four steady state operating speeds, with repeats. Dynamic pressure and temperature data were acquired at each condition for at least one minute. At the two highest power settings, temperature data could not be obtained at the forward probe locations since the mean temperatures exceeded the capability of the probes. The temperature data were processed using software that accounts for the effects of convective and conductive heat transfer. The software was developed under previous NASA sponsored programs. Compensated temperature spectra and compensated time histories corresponding to the dynamic temperature of the gas stream were generated. Auto-spectral and cross-spectral analyses of the data were performed to investigate spectral features, acoustic circumferential mode content, signal coherence, and time delays. The dynamic temperature data exhibit a wideband and fairly flat spectral content. The temperature spectra do not change substantially with operating speed. The pressure spectra in the combustor and ITD exhibit generally similar shapes and amplitudes, making it difficult to identify any features that suggest the presence of indirect combustion noise. Cross-spectral analysis reveal a strong correlation between pressure and temperature fluctuations in the ITD, but little correlation between temperature fluctuations at the entrance of the HPT and pressure fluctuations downstream of it. Temperature fluctuations at the entrance of the low pressure turbine were an order of magnitude smaller than those at the entrance to the high pressure turbine. Time delay analysis of the temperature fluctuations in the combustor was inconclusive, perhaps due to the substantial mixing that occurs between the upstream and downstream locations. Time delay analysis of the temperature fluctuations in the ITD indicate that they convect at the mean flow speed. Analysis of the data did not reveal any convincing indications of the presence of indirect combustion noise. However, this analysis has been preliminary and additional exploration of the data is recommended including the use of more sophisticated signal processing to explore subtle issues that have been revealed but which are not yet fully understood or explained.

Aeroacoustics↗

Water-Cooled Optical Thermometer

Water-cooled optical probe measures temperature of nearby radiating object. Intended primarily for use in silicon-growing furnace for measuring and controlling temperatures of silicon ribbon, meniscus, cartridge surfaces, heaters, or other parts. Cooling water and flushing gas cool fiber-optic probe and keep it clean. Fiber passes thermal radiation from observed surface to measuring instrument.

Menna, A. A.↗

An "Inefficient Fin" Non-Dimensional Parameter to Measure Gas Temperatures Efficiently

A gas containment vessel that is not in thermal equilibrium with the bulk gas can affect its temperature measurement. The physical nature of many gas dynamics experiments often makes the accurate measurement of temperature a challenge. The environment itself typically requires that the thermocouple be sheathed, both to protect the wires and hot junction of the instrument from their environment, and to provide a smooth, rigid surface for pressure sealing of the enclosure. However, that enclosure may also be much colder than the gas to be sensed, or vice-versa. Either way, the effect of such gradients is to potentially skew the temperature measurements themselves, since heat may then be conducted by the instrument. Thermocouple designers traditionally address this problem by insulating the sheath from the thermocouple leads and hot junction as much as possible. The thermocouple leads are typically packed in a ceramic powder inside the sheath, protecting them somewhat from temperature gradients along the sheath, but there is no effective mechanism to shield the sheath from the enclosure body itself. Standard practice dictates that thermocouples be used in installations that do not present large thermal gradients along the probe. If this conduction dominates heat transfer near the tip of the probe, then temperature measurements may be expected to be skewed. While the same problem may be experienced in the measurement of temperature at various points within a solid in a gradient, it tends to be aggravated in the measurements of gas temperature, since heat transfer dependent on convection is often less efficient than conduction along the thermocouple. The proposed solution is an inefficient fin thermocouple probe. Conventional wisdom suggests that in many experiments where gas flows through an enclosure (e.g., flow in pipe, manifold, nozzle, etc.), the thermocouple be introduced flush to the surface, so as not to interfere with the flow. In practice, however, many such experiments take place where the flow is already turbulent, so that a protruding thermocouple probe has a negligible effect on the flow characteristics. The key question then becomes just how far into the flow should a thermocouple protrude in order to properly sense the gas temperature at that point. Modeling the thermocouple as an "inefficient fin" directly addresses this question. The appropriate assumptions in this case are: one-dimensional conduction along the fin; steady-state, constant, and homogeneous thermal conductivity; negligible radiation; and a uniform, constant heat transfer coefficient over the probe surface. It is noted that the nature of the ceramic-filled probe makes the key assumption of homogeneous thermal conductivity that much more conservative.

Lemieux, Patrick↗

CFD modeling of natural circulation in LiCl-KCl molten salt closed loop

Characterizing flow within a molten salt closed-loop system is crucial for assessing system requirements, evaluating performance, and identifying potential flaws. Direct flow measurement using instrumentation is challenging due to extreme environmental conditions and the limitations associated with measuring molten salt flow under natural convection. Here, this study aims to provide comprehensive insights into the thermal-hydraulic behavior of a closed loop, with a particular focus on temperature distribution and velocity prediction. The Computational Fluid Dynamics (CFD) model demonstrated the capability to effectively simulate and predict both temperature distributions and flow velocities within the molten salt loop. The CFD model's predictive capability was validated by its ability to replicate temperature measurements under varying boundary conditions. The analysis revealed that the CFD model tends to underpredict temperatures in the cold leg and overpredict them in the hot leg, highlighting the need for continuous model refinement and acknowledging the limitations of using a steady-state approach. Furthermore, the potential of using external temperature measurements to estimate internal molten salt temperatures and predict flow velocity was explored, revealing that this approach could introduce up to a 5.5% error in flow velocity calculations. Line probes mapping temperature distributions across the tube's cross-section and molten salt provided valuable insights into temperature gradients, emphasizing the need for a thermal conductivity equation for molten salt with lower uncertainty to achieve more accurate temperature predictions of the system.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental Results on SS 304H and 2.25Cr-1Mo in Support of Developing Inelastic Constitutive Models

To address critical data gaps necessary for updating viscoplastic constitutive material models for Class A materials used in inelastic design analysis under the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, Section III, Division 5, High Temperature Reactors, Oak Ridge National Laboratory (ORNL) conducted experimental studies on stainless steel 304H (SS 304H) and 2¼Cr-1Mo steel (F22), to probe their temperature dependent deformation behaviors. These studies covered a range of temperatures up to the maximum limits specified in Division 5 and are intended to support the development of material models by collaborators at Argonne National Laboratory (ANL).

36 MATERIALS SCIENCE↗

Atmospheric Dynamics on Venus, Jupiter, and Saturn: An Observational and Analytical Study

Determining the static stability of Jupiter's atmosphere below the visible cloud levels is important for understanding the dynamical modes by which energy and momentum are transported through Jupiter's deep troposphere. The Galileo Probe Atmospheric Structure Investigation (ASI) employed pressure and temperature sensors to directly measure these state variables during the parachute-descent phase, which started at a pressure (p) of 0.4 bars and ended at p= 22 bars. The internal temperature of the probe underwent large temperature fluctuations which significantly exceeded design specifications. Corrections for these anomalous interior temperatures have been evaluated based on laboratory data acquired after the mission using the flight spare hardware. The corrections to the pressure sensor readings was particularly large and the uncertainties in the atmospheric pressures derived from the p sensor measurements may still be significant. We have sought to estimate the formal uncertainties in the static stability derived from the p and T sensor measurements directly and to devise means of assessing the static stability of Jupiter's atmosphere which do not rely on the p sensor data.

Bridger, Alison↗

A new method for in situ electron temperature determinations from plasma wave phenomena

A discrepancy has been reported between the values of the electron temperature t sub e deduced from satellite electrostatic probe measurements and ground based radar backscatter measurements. This discrepancy (radar backscatter temperature less than the probe temperature) is not present when the probe experiment is flown on a rocket to lower altitudes but reappears when the rocket probe attains higher altitudes. There is a need for an independent radio wave method for making in-situ t sub e measurements in order to help resolve this problem. A new method of determining t sub e from the satellite resonant phenomena is presented. It is based on the splitting (observed at high latitudes) of the diffuse resonance which occurs at the frequency f sub d1 between f sub h and 2 f sub h. The advantage of this method over the other methods involving ionospheric resonances is the simplicity of the required calculations. There is, however, the limitation of plasma conditions where the f sub d1 resonance can be observed and the limitation to mid-to-high latitudes where the splitting is observed.

Oya, H.↗

Plume characteristics of MPD thrusters: A preliminary examination

A diagnostics facility for MPD thruster plume measurements was built and is currently undergoing testing. The facility includes electrostatic probes for electron temperature and density measurements, Hall probes for magnetic field and current distribution mapping, and an imaging system to establish the global distribution of plasma species. Preliminary results for MPD thrusters operated at power levels between 30 and 60 kW with solenoidal applied magnetic fields show that the electron density decreases exponentially from 1x10(2) to 2x10(18)/cu m over the first 30 cm of the expansion, while the electron temperature distribution is relatively uniform, decreasing from approximately 2.5 eV to 1.5 eV over the same distance. The radiant intensity of the ArII 4879 A line emission also decays exponentially. Current distribution measurements indicate that a significant fraction of the discharge current is blown into the plume region, and that its distribution depends on the magnitudes of both the discharge current and the applied magnetic field.

Myers, Roger M.↗