Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Surgery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Real-time Focused Ultrasound Surgery (FUS) Monitoring Using Harmonic Motion Imaging (HMI)

Monitoring changes in tissue mechanical properties to optimally control thermal exposure is important in thermal therapies. The amplitude-modulated (AM) harmonic motion imaging (HMI) for focused ultrasound (HMIFU) technique is a radiation force technique, which has the capability of tracking tissue stiffness during application of an oscillatory force. The feasibility of HMIFU for assessing mechanical tissue properties has been previously demonstrated. In this paper, a confocal transducer, combining a 4.5 MHz FUS transducer and a 3.3 MHz phased array imaging transducer, was used. The FUS transducer was driven by AM wave at 15 Hz with an acoustic intensity (I{sub spta}) was equal to 1050 W/cm{sup 2}. A lowpass digital filter was used to remove the spectrum of the higher power beam prior to displacement estimation. The resulting axial tissue displacement was estimated using 1D cross-correlation with a correlation window of 2 mm and a 92.5% overlap. A thermocouple was also used to measure the temperature near the ablated region. 2D HMI-images from six-bovine-liver specimens indicated the onset of coagulation necrosis through changes in amplitude displacement after coagulation due to its simultaneous probing and heating capability. The HMI technique can thus be used to monitor temperature-related stiffness changes of tissues during thermal therapies in real-time, i.e., without interrupting or modifying the treatment protocol.

60 APPLIED LIFE SCIENCES↗

The possibility for use of venous flaps in plastic surgery

The use of venous flaps is controversial. The mechanism of perfusion of venous flaps is still not fully understood. The research was conducted on 56 white rats. In our experimental work we studied two different models of venous flaps: pedicled venous flap (PVF) and pedicled arterialized venous flap (PAVF). Our results showed that postoperative congestion was present in all flaps. However 66.7% of all pedicled venous flaps and 100% of all pedicled arterialized venous flaps eventually survived. Histological examination revealed that postoperatively the blood flow in the skin of the pedicled arterialized venous flap became «re-reversed» again; there were no differences between mechanism of survival of venous flaps and other flaps. On the 7-14th day in the skin of all flaps were processes of neoangiogenesis and proliferation. Hence the best scenario for the clinical use of venous flaps unfolds when both revascularization and skin coverage are required.

60 APPLIED LIFE SCIENCES↗

Structural properties of a bone-ceramic composite as a promising material in spinal surgery

The paper describes the results of in vitro tests of composite bone-ceramic implants and procedures for modifying implant surfaces to enhance osteogenesis. Analysis of CBCI ESs demonstrated that they have a porous structure with the mean longitudinal pore size of 70 µm and the mean transverse pore size of 46 µm; surface pores are open, while inner pores are closed. Elemental analysis of the CBCI surface demonstrates that CBCIs are composed of aluminum and zirconium oxides and contain HA inclusions. Profilometry of the CBCI ES surface revealed the following deviations: the maximum deviation of the profile in the sample center is 15 µm and 16 µm on the periphery, while the arithmetical mean and mean square deviations of the profile are 2.65 and 3.4 µm, respectively. In addition, CBCI biodegradation products were pre-examined; a 0.9% NaCl solution was used as a comparison group. Potentially toxic and tissue accumulated elements, such as cadmium, cobalt, mercury, and lead, are present only in trace amounts and have no statistically significant differences with the comparison group, which precludes their potential toxic effects on the macroorganism. Ceramic-based CBCI may be effective and useful in medicine for restoration of the anatomic integrity and functions of the bone tissue.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of silver additive on physicochemical properties of hydroxyapatite applied to reconstructive surgery

The effect of silver adding to hydroxyapatite (HA) in its solubility in physiological solution and biological activity was investigated. Samples of HA containing silver (AgHA) obtained by liquid-phase method in the conditions of microwave exposure. Solubility (C{sub Ca}{sup 2+}·10{sup 3}, mol/l) of the powders AgHA was determined by chemical methods according trilonometric titration of the calcium ions in physiological solution at 25 and 37 °C. To investigate the biological activity of the samples, a series of experiments on the formation of the calcium-phosphate layer on the surface of the SBF-solution at 37 °C for 28 days. Electronic micrographs of samples taken at the end of each 7 days of the experiment, indicate the formation of calcium-phosphate layer (CPL) in the samples, the kinetics of which is shown as a function of cumulative concentrations of calcium and magnesium ions from time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TU-CD-207-09: Analysis of the 3-D Shape of Patients’ Breast for Breast Imaging and Surgery Planning

Purpose: Develop a method to accurately capture the 3-D shape of patients’ external breast surface before and during breast compression for mammography/tomosynthesis. Methods: During this IRB-approved, HIPAA-compliant study, 50 women were recruited to undergo 3-D breast surface imaging during breast compression and imaging for the cranio-caudal (CC) view on a digital mammography/breast tomosynthesis system. Digital projectors and cameras mounted on tripods were used to acquire 3-D surface images of the breast, in three conditions: (a) positioned on the support paddle before compression, (b) during compression by the compression paddle and (c) the anterior-posterior view with the breast in its natural, unsupported position. The breast was compressed to standard full compression with the compression paddle and a tomosynthesis image was acquired simultaneously with the 3-D surface. The 3-D surface curvature and deformation with respect to the uncompressed surface was analyzed using contours. The 3-D surfaces were voxelized to capture breast shape in a format that can be manipulated for further analysis. Results: A protocol was developed to accurately capture the 3-D shape of patients’ breast before and during compression for mammography. Using a pair of 3-D scanners, the 50 patient breasts were scanned in three conditions, resulting in accurate representations of the breast surfaces. The surfaces were post processed, analyzed using contours and voxelized, with 1 mm{sup 3} voxels, converting the breast shape into a format that can be easily modified as required. Conclusion: Accurate characterization of the breast curvature and shape for the generation of 3-D models is possible. These models can be used for various applications such as improving breast dosimetry, accurate scatter estimation, conducting virtual clinical trials and validating compression algorithms. Ioannis Sechopoulos is consultant for Fuji Medical Systems USA.

60 APPLIED LIFE SCIENCES↗

Patient Selection for Clinical Trials Eliminating Surgery for HER2-Positive Breast Cancer Treated with Neoadjuvant Systemic Therapy

Background: Patients with epidermal growth factor receptor 2-positive (HER2+) breast cancer and pathologic complete response (pCR) after neoadjuvant systemic therapy (NST) may be candidates for nonoperative clinical trials if residual invasive and in situ disease are eradicated. Methods: This study analyzed 280 patients with clinical T1-2N0-1 HER2+ breast cancer who underwent NST followed by surgical resection to determine key characteristics of patients with pCR in the breast and lymph nodes compared with those with residual disease. Results: Of the 280 patients, 102 (36.4%) had pCR in the breast and lymph nodes after NST, and 50 patients (17.9%) had residual ductal carcinoma in situ (DCIS) in the breast only. For 129 patients (46.1%), DCIS was present on the pretreatment biopsy, and NST failed to eradicate the DCIS component in 64.3%. Patients with residual disease were more likely to have hormone receptor-positive (HR+) tumors than those with negative tumors (73.4% vs. 50.8%; p < 0.0001). Radiologic response (odds ratio [OR], 5.62; p = 0.002) and HR+ status (OR, 2.56; p < 0.0001) were predictive of residual disease. Combined imaging methods after NST had a sensitivity of 97.1% and a negative predictive value of 70.6% for detection of residual disease. Patients with invasive disease and DCIS shown on the pretreatment core biopsy were less likely than those without DCIS to achieve pCR in the breast (31% vs. 43%; p = 0.038). Conclusion: The study results delineate and identify unique characteristics associated with HER2+ breast cancers that are important in selecting patients for inclusion in clinical trials assessing nonoperative management after NST, and the low negative predictive value of imaging mandates image-guided biopsy for selection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Local Recurrence Risk Estimates After Breast-Conserving Surgery for DCIS: DCIS Nomogram Versus Refined Oncotype DX Breast DCIS Score

Background: A ductal carcinoma in situ (DCIS) Nomogram integrating 10 clinicopathologic/treatment factors and a Refined DCIS Score (RDS) that incorporates a genomic assay and three clinicopathologic factors (Oncotype DX DCIS Score) are available to estimate DCIS 10-year local recurrence risk (LRR). This study compared these estimates. Methods: Patients 50 years of age or older with DCIS size 2.5 cm or smaller and a genomic assay available were identified. An RDS within 1–2% of the range of Nomogram LRR estimates obtained by assuming use and non-use of endocrine therapy (Nomogram ± ET) was defined as concordant. Assuming a 10-year risk threshold of 10% for recommending radiation, Nomogram ± ET and RDS estimates were compared, and threshold concordance was determined. Results: For 54 (92%) of 59 patients, the RDS and Nomogram ± ET LRR estimates were concordant. For the remaining 5 (8%) of the 59 patients, the RDS LRR estimates were lower than the Nomogram + ET estimates, with an absolute difference of 3–8%, and thus were discordant. For these five patients, the RDS estimates of 10-year LRR were lower than 10% (range 5–8%) and the Nomogram + ET estimates were 10% or higher (range 11–14%). These five patients with both discordant and threshold-discordant estimates all had close margins (≤ 2 mm). Conclusions: Among 92% of women 50 years of age or older with DCIS size 2.5 cm or smaller, free-of-charge online Nomogram 10-year LRR estimates were concordant with those obtained using the commercially available RDS (> $4600). Among the 8% with discordant risk estimates, the RDS appeared to underestimate the LRR and may lead to inappropriate omission of radiotherapy. Unless other data show a clinically significant advantage of the RDS (Oncotype DX DCIS Score), the study data suggest that for women 50 years of age or older with DCIS size 2.5 cm or smaller, its use is not warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Trauma Pod: A Semi-Automated Robotic Surgery System

The Trauma Pod (TP) vision is to develop a rapidly deployable robotic system to perform critical acute stabilization and/or surgical procedures autonomously or in a teleoperative mode on wounded soldiers in the battlefield who might otherwise die before treatment in a combat hospital can be provided. In the first phase of a project pursuing this vision, a robotic TP system was developed and its capability demonstrated by performing select surgical procedures on a patient phantom. The system demonstrates the feasibility of performing acute stabilization procedures with the patient being the only human in the surgical cell. The teleoperated surgical robot is supported by autonomous arms that carry out scrub-nurse and circulating-nurse functions. Tool change and supply delivery are performed automatically and at least as fast as those performed manually by nurses. The TP system also includes tomographic X-ray facility for patient diagnosis and 2-D fluoroscopic data to support interventions. The vast amount of clinical protocols generated in the TP system are recorded automatically. These capabilities form the basis for a more comprehensive acute diagnostic and management platform that will provide life-saving care in environments where surgical personnel are not present.

42 ENGINEERING↗

Furthering Precision in Sentinel Node Navigational Surgery for Oral Cancer: a Novel Triple Targeting System

To describe an innovative sentinel lymph node (SLN) guidance approach using a radionuclide tracer, 3D augmented reality-guided imaging, and near infrared (NIR) fluorescence over-lay imaging with hand-held probes to optimize accuracy, efficiency, and precise navigation for sentinel node (SN) localization in head and neck cancer. In a cT1N0M0 squamous cell carcinoma of the tongue, pre-operative radionuclide lymphoscintigraphy was performed with a sentinel node-specific radiolabeled tracer. Intraoperatively, a 3D hand-held augmented reality (AR) scanning SPECT probe assessed concordance of the SN with pre-operative SPECT-CT images. The real-time optical video was linked to the SPECT-CT images for added precision. Final guidance to the SN was performed using ICG fluorescence imaging. Dynamic and SPECT-CT showed bilateral lymphatic drainage from the tumor. The 3D hand-held AR SPECT probe SN localization was concordant with pre-operative imaging. The optical video successfully demonstrated the lymphatic drainage in real-time through a unique overlay fluorescence image. The ICG localized to the same nodes identified by both the SPECT-CT and hand-held SPECT images. The use of dual radiation and fluorescence tracers improved SN detection, especially for SN close to the injection site. The hand-held probes allowed the surgeon to dissect continuously, without needing to change tools. The combination of augmented reality, nuclear medicine, and over-lay fluorescence imaging allowed greater accuracy for matching the preoperative imaging with intraoperative identification and precisely guiding the dissection. This method uniquely permitted the surgeon to efficiently dissect the SN with accurate visualization and optimal precision.

62 RADIOLOGY AND NUCLEAR MEDICINE↗