Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Super resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Performance of Flash Lidar with Real-time Image Enhancement Algorithm for Landing Hazard Avoidance

Performance of a 3-D imaging flash lidar employing a novel super-resolution algorithm is characterized by a series of static and dynamic tests. A gantry test of this lidar in which the lidar was placed in an instrumented moving basket above a calibrated hazard field proved an excellent demonstration of hazard avoidance capabilities. Results of the gantry test are reported and potential of flash lidar utilizing super-resolution algorithm for future landing missions are explained.

Hazard Detection↗

Heisenberg-limited interferometry with pair coherent states and parity measurements

After reviewing parity-measurement-based interferometry with twin Fock states, which allows for supersensitivity (Heisenberg limited) and super-resolution, we consider interferometry with two different superpositions of twin Fock states, namely, two-mode squeezed vacuum states and pair coherent states. This study is motivated by the experimental challenge of producing twin Fock states on opposite sides of a beam splitter. We find that input two-mode squeezed states, while allowing for Heisenberg-limited sensitivity, do not yield super-resolutions, whereas both are possible with input pair coherent states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Heralded Generation of an Atomic NOON State

We report the heralded generation of an atomic NOON state by observation of phase super resolution in a motion-sensitive spin-wave (SW) interferometer. The SW interferometer is implemented by generating a superposition of two SWs and observing the interference between them, where the interference fringe is sensitive to the atomic collective motion. By heralded generation of a second order NOON state in the SW interferometer, we observe the interference pattern which provides strong evidence of phase super resolution. The demonstrated SW interferometer can in principle be scaled up to a highly entangled state, and thus is of fundamental importance, and might be used as an inertial sensor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mapping Emission from Clusters of CdSe/ZnS Nanoparticles

In this paper, we have carried out correlated super-resolution and SEM imaging studies of clusters of CdSe/ZnS nanoparticles containing up to ten particles to explore how the fluorescence behavior of these clusters depends on the number of particles, the specific cluster geometry, the shell thickness, and the technique used to produce the clusters. The total emission yield was less than proportional to the number of particles in the clusters for both thick and thin shells. With super-resolution imaging, the emission center of the cluster could be spatially resolved at distance scales on the order of the cluster size. The intrinsic fluorescence intermittency of the nanoparticles altered the emission distribution across the cluster, which enabled the identification of relative emission intensities of individual particles or small groups of particles within the cluster. Finally, for clusters undergoing interparticle energy transfer, donor/acceptor pairs and regions where energy was funneled could be identified.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TH-CD-206-05: Machine-Learning Based Segmentation of Organs at Risks for Head and Neck Radiotherapy Planning

Purpose: Accurate and efficient delineation of tumor target and organs-at-risks is essential for the success of radiotherapy. In reality, despite of decades of intense research efforts, auto-segmentation has not yet become clinical practice. In this study, we present, for the first time, a deep learning-based classification algorithm for autonomous segmentation in head and neck (HaN) treatment planning. Methods: Fifteen HN datasets of CT, MR and PET images with manual annotation of organs-at-risk (OARs) including spinal cord, brainstem, optic nerves, chiasm, eyes, mandible, tongue, parotid glands were collected and saved in a library of plans. We also have ten super-resolution MR images of the tongue area, where the genioglossus and inferior longitudinalis tongue muscles are defined as organs of interest. We applied the concepts of random forest- and deep learning-based object classification for automated image annotation with the aim of using machine learning to facilitate head and neck radiotherapy planning process. In this new paradigm of segmentation, random forests were used for landmark-assisted segmentation of super-resolution MR images. Alternatively to auto-segmentation with random forest-based landmark detection, deep convolutional neural networks were developed for voxel-wise segmentation of OARs in single and multi-modal images. The network consisted of three pairs of convolution and pooing layer, one RuLU layer and a softmax layer. Results: We present a comprehensive study on using machine learning concepts for auto-segmentation of OARs and tongue muscles for the HaN radiotherapy planning. An accuracy of 81.8% in terms of Dice coefficient was achieved for segmentation of genioglossus and inferior longitudinalis tongue muscles. Preliminary results of OARs regimentation also indicate that deep-learning afforded an unprecedented opportunities to improve the accuracy and robustness of radiotherapy planning. Conclusion: A novel machine learning framework has been developed for image annotation and structure segmentation. Our results indicate the great potential of deep learning in radiotherapy treatment planning.

60 APPLIED LIFE SCIENCES↗

Cytoskeletal organization in microtentacles

Microtentacles are thin, flexible cell protrusions that have recently been described and whose presence enhances efficient attachment of circulating cells. They are found on circulating tumor cells and can be induced on a wide range of breast cancer cell lines, where they are promoted by factors that either stabilize microtubules or destabilize the actin cytoskeleton. Evidence suggests that they are relevant to the metastatic spread of cancer, so understanding their structure and formation may lead to useful therapies. Microtentacles are formed by microtubules and contain vimentin intermediate filaments, but beyond this, there is little information about their ultrastructure. We have used electron microscopy of high pressure frozen sections and tomography of cryo-prepared intact cells, along with super resolution fluorescence microscopy, to provide the first ultrastructural insights into microtubule and intermediate filament arrangement within microtentacles. By scanning electron microscopy it was seen that microtentacles form within minutes of addition of drugs that stabilize microtubules and destabilize actin filaments. Mature microtentacles were found to be well below one micrometer in diameter, tapering gradually to below 100 nm at the distal ends. They also contained frequent branches and bulges suggestive of heterogeneous internal structure. Super resolution fluorescence microscopy and examination of sectioned samples showed that the microtubules and intermediate filaments can occupy different areas within the microtentacles, rather than interacting intimately as had been expected. Cryo-electron tomography of thin regions of microtentacles revealed densely packed microtubules and absence of intermediate filaments. The number of microtubules ranged from several dozen in some areas to just a few in the thinnest regions, with none of the regular arrangement found in axonemes. Improved understanding of the mechanism of microtentacle formation, as well as the resultant structure, will be valuable in developing therapies against metastasis, if the hypothesized role of microtentacles in metastasis is confirmed. This work provides a significant step in this direction. - Highlights: • Microtentacles can form within minutes of the addition of inducing drugs. Microtentacle diameters are in the range of a tenth of a micrometer. • Microtubules are clearly resolved in microtentacles by cryo-electron tomography. • There is little microtubule-intermediate filament interaction in drug-induced microtentacles.

60 APPLIED LIFE SCIENCES↗

Large‐Area, High‐Numerical‐Aperture, Freeform Metasurfaces

Abstract Nanophotonic devices are optical platforms capable of unprecedented wavefront control. To push the limits of experimental device performance, scalable design methodologies that combine the simplicity and fabricability of conventional design paradigms with the extended capabilities of freeform optimization are required. A novel gradient‐based design framework for large‐area freeform metasurfaces is introduced in which nonlocal interactions between simply shaped nanostructures, placed on an irregular lattice, are tailored to produce high‐order hybridized modes that support customizable large‐angle scattering profiles. Utilizing this approach, multifunctional super‐dispersive metalenses are designed and experimentally demonstrated. The approach to high‐numerical‐aperture radial metalenses capable of diffraction limited focusing and the generation of donut‐shaped point spread functions is also extended. It is anticipated that these concepts will have utility in super‐resolution microscopy, particle trapping, additive manufacturing, and metrology applications that require ultra‐high numerical apertures.

Optics↗

Far-field speckle correlations as a function of object position for microscopically distinguishing objects hidden in a randomly scattering medium

Super-resolution optical sensing is of critical importance in science and technology and has required prior information about an imaging system or obtrusive near-field probing. Additionally, coherent imaging and sensing in heavily scattering media such as biological tissue has been challenging, and practical approaches have either been restricted to measuring the field transmission of a single point source, or to where the medium is thin. We present the concept of far-subwavelength spatial sensing with relative object motion in speckle as a means to coherently sense through heavy scatter. Experimental results demonstrate the ability to distinguish nominally identical objects with nanometer-scale translation while hidden in randomly scattering media, without the need for precise or known location and with imprecise replacement. The theory and supportive illustrations presented provide the basis for super-resolution sensing and the possibility of virtually unlimited spatial resolution, including through thick, heavily scattering media with relative motion of an object in a structured field. This work provides enabling opportunities for material inspection, security, and biological sensing.

Hastings, Ryan L. (ORCID:0009000095977807)↗

Dynamic heterogeneity of DNA methylation and hydroxymethylation in embryonic stem cell populations captured by single-cell 3D high-content analysis

Cell-surface markers and transcription factors are being used in the assessment of stem cell fate and therapeutic safety, but display significant variability in stem cell cultures. We assessed nuclear patterns of 5-hydroxymethylcytosine (5hmC, associated with pluripotency), a second important epigenetic mark, and its combination with 5-methylcytosine (5mC, associated with differentiation), also in comparison to more established markers of pluripotency (Oct-4) and endodermal differentiation (FoxA2, Sox17) in mouse embryonic stem cells (mESC) over a 10-day differentiation course in vitro: by means of confocal and super-resolution imaging together with 3D high-content analysis, an essential tool in single-cell screening. In summary: 1) We did not measure any significant correlation of putative markers with global 5mC or 5hmC. 2) While average Oct-4 levels stagnated on a cell-population base (0.015 lnIU/day), Sox17 and FoxA2 increased 22-fold and 3-fold faster, respectively (Sox17: 0.343 lnIU/day; FoxA2: 0.046 lnIU/day). In comparison, global DNA methylation levels increased 4-fold faster (0.068 lnIU/day), and global hydroxymethylation declined at 0.046 lnIU/day, both with a better explanation of the temporal profile. 3) This progression was concomitant with the occurrence of distinct nuclear codistribution patterns that represented a heterogeneous spectrum of states in differentiation; converging to three major coexisting 5mC/5hmC phenotypes by day 10: 5hmC{sup +}/5mC{sup −}, 5hmC{sup +}/5mC{sup +}, and 5hmC{sup −}/5mC{sup +} cells. 4) Using optical nanoscopy we could delineate the respective topologies of 5mC/5hmC colocalization in subregions of nuclear DNA: in the majority of 5hmC{sup +}/5mC{sup +} cells 5hmC and 5mC predominantly occupied mutually exclusive territories resembling euchromatic and heterochromatic regions, respectively. Simultaneously, in a smaller subset of cells we observed a tighter colocalization of the two cytosine variants, presumably delineating chromatin domains in remodeling. We conclude that 1) 5mC emerges as the most differential marker in our model system. 2) However, the combined enrollment of the two DNA modifications provided higher-definition screening and lead to the identification of cell subpopulations based on differential 5hmC/5mC phenotypes corresponding to different 5hmC/5mC ratios. The results encourage: a) assessing the regenerative potential of early-endodermal cells enriched for the three DNA methylation/hydroxymethylation categories, and b) exploring the universality of this type of epigenetic phenotyping across other lineage-specific differentiations. - Highlights: • First reported single-molecule super-resolution 3D-visualization of 5mC/5hmC sites in cells. • Identification of cells with differential 5mC/5hmC nuclear codistribution phenotypes. • Application of principle component and robust regression analyses for evaluation of 3D high-content-screening data. • Global 5mC constitutes a highly differential spatiotemporal in situ marker in early endodermal cell differentiation.

60 APPLIED LIFE SCIENCES↗

An Approach to Application of Multispectral Sensors, using AVIRIS Data

High spatial resolution multispectral/hyperspectral sensors are being developed by private industry with science/research customers as end users. With an increasingly wide range of sensor choices, it is important for the remote sensing science community and commercial community alike to understand the trade-offs between ground sample distance (GSD), spectral resolution, and signal-to-noise ratio (SNR) in selecting a sensor that will best meet their needs. High spatial resolution hyperspectral imagery and super resolution multispectral charge-coupled device imagery can be used to develop prototypes of proposed data acquisition systems without building new systems or collecting large sets of additional data. By using these datasets to emulate proposed and existing systems, imaging systems may be optimized to meet customer needs in a virtual environment. This approach also enables one to determine, a priori, whether an existing dataset will be useful for a given application.

Warner, Amanda↗

High Resolution Image Reconstruction from Projection of Low Resolution Images DIffering in Subpixel Shifts

In this paper, we demonstrate a simple algorithm that projects low resolution (LR) images differing in subpixel shifts on a high resolution (HR) also called super resolution (SR) grid. The algorithm is very effective in accuracy as well as time efficiency. A number of spatial interpolation techniques using nearest neighbor, inverse-distance weighted averages, Radial Basis Functions (RBF) etc. used in projection yield comparable results. For best accuracy of reconstructing SR image by a factor of two requires four LR images differing in four independent subpixel shifts. The algorithm has two steps: i) registration of low resolution images and (ii) shifting the low resolution images to align with reference image and projecting them on high resolution grid based on the shifts of each low resolution image using different interpolation techniques. Experiments are conducted by simulating low resolution images by subpixel shifts and subsampling of original high resolution image and the reconstructing the high resolution images from the simulated low resolution images. The results of accuracy of reconstruction are compared by using mean squared error measure between original high resolution image and reconstructed image. The algorithm was tested on remote sensing images and found to outperform previously proposed techniques such as Iterative Back Projection algorithm (IBP), Maximum Likelihood (ML), and Maximum a posterior (MAP) algorithms. The algorithm is robust and is not overly sensitive to the registration inaccuracies.

Quantifying the Impact of Charge Rate and Number of Cycles on Structural Degeneration of Li-Ion Battery Electrodes

A quantitative link between crack evolution in lithium-ion positive electrodes and the degrading performance on cells is not yet well established nor is any single technique capable of doing so widely available. Here, we demonstrate a widely accessible high-throughput approach to quantifying crack evolution within electrodes. The approach applies super-resolution scanning electron microscopy (SEM) imaging of cross-sectioned NMC532 electrodes, followed by segmentation and quantification of crack features. Crack properties such as crack intensity, crack width and length are quantified as a function of charge rate (1C, 6C, and 9C) and cycle number (25, 225, and 600 cycles). Hundreds of particles are characterized for statistical confidence in the quantitative crack measurements. The data on crack evolution is compared to electrochemical data from full cells and half cells with the NMC532 positive electrodes. We show that while crack evolution strongly correlates with capacity fade in the first 25 cycles, it does not correlate well for the following hundreds of cycles indicating that cracking may not be the dominant cause of capacity fade throughout the cycle-life of cells.

25 ENERGY STORAGE↗

Photoabsorption Imaging at Nanometer Scales Using Secondary Electron Analysis

Optical imaging with nanometer resolution offers fundamental insights into light–matter interactions. Traditional optical techniques are diffraction limited with a spatial resolution >100 nm. Optical super-resolution and cathodoluminescence techniques have higher spatial resolutions, but these approaches require the sample to fluoresce, which many materials lack. Here, we introduce photoabsorption microscopy using electron analysis, which involves spectrally specific photoabsorption that is locally probed using a scanning electron microscope, whereby a photoabsorption-induced surface photovoltage modulates the secondary electron emission. We demonstrate spectrally specific photoabsorption imaging with sub-20 nm spatial resolution using silicon, germanium, and gold nanoparticles. Theoretical analysis and Monte Carlo simulations are used to explain the basic trends of the photoabsorption-induced secondary electron signal. Based on our current experiments and this analysis, we expect that the spatial resolution can be further improved to a few nanometers, thereby offering a general approach for nanometer-scale optical spectroscopic imaging and material characterization.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Improving Imaging Instrument Spatial Resolution Using Software

In order to overcome spatial resolution limitations associated with physical sensor limitations when using smallsats and cubesats, we utilize an image processing technology referred to as Super-Resolution (SR). In general, software approaches are increasingly considered in connection with smaller satellites for which size, mass and power constraints limit the sensor capabilities. Being able to perform hardware vs. software trades might enable more capabilities for a lower cost. This paper describes recent experiments conducted to optimize the spatial enhancement of acquired observations using multiple sub-pixel shifted low resolution image.

Image Processing↗

Improving the Spatial Resolution of Imaging Instruments Using Software

In order to overcome spatial resolution limitations associated with physical sensor limitations when using smallsats and cubesats, we utilize an image processing technology referred to as Super-Resolution (SR). In general, software approaches are increasingly considered in connection with smaller satellites for which size, mass and power constraints limit the sensor capabilities. Being able to perform hardware vs. software trades might enable more capabilities for a lower cost. This paper describes recent experiments conducted to optimize the spatial enhancement of acquired observations using multiple sub-pixel shifted low resolution image.

Image Processing↗

Removal of Homogeneous Broadening from 1 H-Detected Multidimensional Solid-State NMR Spectra

1 H-detected magic-angle spinning (MAS) NMR experiments have revolutionized the NMR studies of biological and inorganic solids by providing unparalleled sensitivity and resolution. Despite these gains, homogeneous broadening, originating from the incomplete removal of homonuclear dipolar interactions under fast MAS, remains highly prevalent and limits the achievable resolution. In direct analogy to super-resolution microscopy methods, we show that resolution beyond that currently achievable by fast MAS alone can be obtained by experiment-driven deconvolution. Following the acquisition of a single 2D NMR spectrum to measure the frequency-dependent homogeneous lineshapes, any number of 1 H-detected spectra can be enhanced in resolution, yielding comparable spectra as obtained with twice the MAS frequency. In conclusion, the versatility of this approach is demonstrated in the enhancement of single- and double-quantum homonuclear correlation spectra, in addition to heteronuclear correlation spectra acquired on a surface organometallic complex and the protein GB1.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗