Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Statistical Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Discriminating Nuclear Threats from Benign Sources in Gamma-ray Spectra using a Spectral Comparison Ratio Method

This manuscript presents a method for categorizing gamma-ray spectra as benign or threatening. It is widely believed that the goal of segregating gamma-ray spectra into benign and threatening populations can achieved with fewer counts than are required for confident characterization of a spectrum’s isotopic composition, while still providing improvement over count-based algorithms. This has potentially important implications on the detection of radiological and nuclear threats, where decisions must be made from analysis of count-starved spectra that dominate the landscape of monitoring special nuclear material transport and lost-or-stolen source search. We report here the method of Spectral Comparison Ratios (SCRs) which is useful in the targeted detection of specific gamma-ray signatures or signature classes. SCRs discriminate between benign and target sources by comparing counts in broad, pre-defined energy bins that are pre-determined using statistical discrimination criteria. The integral component of the SCR algorithm is the location and interdependence of the energy bins, and we discuss the statistical methods used for choosing their locations along with the decision criteria that maximally separate targets from benign sources.

algorithm development↗

Applying compressive sensing to TEM video: A substantial frame rate increase on any camera

One of the main limitations of imaging at high spatial and temporal resolution during in-situ transmission electron microscopy (TEM) experiments is the frame rate of the camera being used to image the dynamic process. While the recent development of direct detectors has provided the hardware to achieve frame rates approaching 0.1 ms, the cameras are expensive and must replace existing detectors. In this paper, we examine the use of coded aperture compressive sensing (CS) methods to increase the frame rate of any camera with simple, low-cost hardware modifications. The coded aperture approach allows multiple sub-frames to be coded and integrated into a single camera frame during the acquisition process, and then extracted upon readout using statistical CS inversion. Here we describe the background of CS and statistical methods in depth and simulate the frame rates and efficiencies for in-situ TEM experiments. Depending on the resolution and signal/noise of the image, it should be possible to increase the speed of any camera by more than an order of magnitude using this approach.

36 MATERIALS SCIENCE↗

Topology for statistical modeling of petascale data.

This document presents current technical progress and dissemination of results for the Mathematics for Analysis of Petascale Data (MAPD) project titled 'Topology for Statistical Modeling of Petascale Data', funded by the Office of Science Advanced Scientific Computing Research (ASCR) Applied Math program. Many commonly used algorithms for mathematical analysis do not scale well enough to accommodate the size or complexity of petascale data produced by computational simulations. The primary goal of this project is thus to develop new mathematical tools that address both the petascale size and uncertain nature of current data. At a high level, our approach is based on the complementary techniques of combinatorial topology and statistical modeling. In particular, we use combinatorial topology to filter out spurious data that would otherwise skew statistical modeling techniques, and we employ advanced algorithms from algebraic statistics to efficiently find globally optimal fits to statistical models. This document summarizes the technical advances we have made to date that were made possible in whole or in part by MAPD funding. These technical contributions can be divided loosely into three categories: (1) advances in the field of combinatorial topology, (2) advances in statistical modeling, and (3) new integrated topological and statistical methods.

99 GENERAL AND MISCELLANEOUS↗

Two-dimensional signal reconstruction: The correlation sampling method

An accurate approach for reconstructing a time-dependent two-dimensional signal from non-synchronized time series recorded at points located on a grid is discussed. The method, denoted as correlation sampling, improves the standard conditional sampling approach commonly employed in the study of turbulence in magnetoplasma devices. Its implementation is illustrated in the case of an artificial time-dependent signal constructed using a fractal algorithm that simulates a fluctuating surface. A statistical method is also discussed for distinguishing coherent (i.e., collective) from purely random (noisy) behavior for such two-dimensional fluctuating phenomena.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tumor-Infiltrating Lymphocytes in a Contemporary Cohort of Women with Ductal Carcinoma In Situ (DCIS)

Background: Growing evidence suggests that the tumor immune microenvironment influences breast cancer development and prognosis. Density of tumor-infiltrating lymphocytes (TILs) within invasive breast cancer is correlated with response to therapy, especially in triple-negative disease. The clinical relevance and outcomes of TILs within ductal carcinoma in situ (DCIS) are less understood. Methods: Our institutional database of 668 patients with pure DCIS from 2010 to 2018 was queried. TILs were evaluated by International TILs Working Group guidelines. Percentage of TILs was assessed from the densest focus (hotspot) in one high-power field of stroma touching the basement membrane. Statistical methods included cluster analyses (to define sparse versus dense TILs), logistic, and Cox regression models. Results: Sixty-nine patients with DCIS and TILs were evaluated, of whom 54 (78%) were treated by breast-conserving surgery. Thirteen (19%) patients had ipsilateral recurrence. Each recurrence (n = 13) was matched to four controls (n = 56) based on date of surgery. Median follow-up was 6.7 years. TILs were defined as sparse (< 45%) or dense (≥ 45%). Dense TILs were associated with younger age (p = 0.045), larger tumor size (p < 0.001), high nuclear grade (p = 0.010), comedo histology (p = 0.033), necrosis (p = 0.027), estrogen receptor (ER) negativity (p = 0.037), and ipsilateral recurrence (p = 0.001). Nine patients with dense TILs had mean time to recurrence of 73.5 months compared with four patients with sparse TILs with mean time to recurrence of 97.9 months (p = 0.003). Conclusions: Dense TILs were significantly associated with age, tumor size, nuclear grade, comedo histology, necrosis, and ER status and was a significant predictor of recurrence in patients with pure DCIS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Resolution, Non-Invasive Imaging of Upper Vocal Tract Articulators Compatible with Human Brain Recordings

A complete neurobiological understanding of speech motor control requires determination of the relationship between simultaneously recorded neural activity and the kinematics of the lips, jaw, tongue, and larynx. Many speech articulators are internal to the vocal tract, and therefore simultaneously tracking the kinematics of all articulators is nontrivial-especially in the context of human electrophysiology recordings. Here, we describe a noninvasive, multi-modal imaging system to monitor vocal tract kinematics, demonstrate this system in six speakers during production of nine American English vowels, and provide new analysis of such data. Classification and regression analysis revealed considerable variability in the articulator-to-acoustic relationship across speakers. Non-negative matrix factorization extracted basis sets capturing vocal tract shapes allowing for higher vowel classification accuracy than traditional methods. Statistical speech synthesis generated speech from vocal tract measurements, and we demonstrate perceptual identification. We demonstrate the capacity to predict lip kinematics from ventral sensorimotor cortical activity. These results demonstrate a multi-modal system to non-invasively monitor articulator kinematics during speech production, describe novel analytic methods for relating kinematic data to speech acoustics, and provide the first decoding of speech kinematics from electrocorticography. These advances will be critical for understanding the cortical basis of speech production and the creation of vocal prosthetics.

60 APPLIED LIFE SCIENCES↗

TH-CD-207B-12: Quantification of Clinical Feedback On Image Quality Differences Between Two CT Scanner Models

Purpose: This work sought to quantify a radiology team’s assessment of image quality differences between two CT scanner models currently in clinical use, with emphasis on noise and low-contrast detectability (LCD). Methods: A water phantom and a Kagaku anthropomorphic body phantom were scanned on GE Discovery CT750 HD and LightSpeed VCT scanners (4 each) with identical scan parameters and reconstructed to 2.5mm/5.0mm thicknesses. Images of water phantom were analyzed at the scanner console with a built-in LCD tool that uses statistical methods to compute requisite CT-number contrast for 95% confidence in detection of a user-defined object size. LCD value was computed for 5mm, 3mm, and 1mm objects. Analysis of standard deviation and LCD values were performed on Kagaku phantom images within liver, stomach, and spleen. LCD value was computed for 4mm, 3mm, and 1mm objects using a benchmarked MATLAB implementation of the GE scanner-console tool. Results: Water LCD values were larger (poorer performance) for all HD scanners compared to VCT scanners. Mean scanner model difference in requisite CT-number contrast for 5mm, 3mm, and 1mm objects for 5.0mm/2.5mm images was 3.0%/3.4% (p=0.02/p=0.10), 5.3%/5.7% (0.00002/0.02), and 8.5%/8.2% (0.0004/0.002), respectively. Mean standard deviations within Kagaku phantom ROIs were greater in HD compared to VCT images, with mean differences for the liver, stomach, and spleen for 5.0mm/2.5mm of 16%/12% (p=0.04/0.10), 8%/12% (0.15/0.11), and 16%/15% (0.05/0.11), respectively. Mean LCD value difference between HD and VCT scanners over all ROIs for 4mm, 3m, and 1mm objects and 5.0mm/2.5mm was 34%/9%, 16%/8%, and 18%/10%, respectively. HD scanners outperformed VCT scanners only for the 4mm stomach object. Conclusion: Using both water and anthropomorphic phantoms, it was shown that HD scanners are outperformed by VCT scanners with respect to noise and LCD in a consistent and in most cases statistically significant manner. The relationship between statistical and clinical significance demands further work.

60 APPLIED LIFE SCIENCES↗

Model Independent Approach to the Single Photoelectron Calibration of Photomultiplier Tubes

The accurate calibration of photomultiplier tubes is critical in a wide variety of applications for which it is necessary to know the absolute number of detected photons or precisely determine the resolution of the signal. Conventional calibration methods rely on fitting the photomultiplier response to a low intensity light source with analytical approximations to the single photoelectron distribution. We show that this approach often leads to biased estimates due to an inability to model the full distribution accurately, especially at low charge values. We present a simple statistical method to extract the relevant single photoelectron calibration parameters (first two central moments) without making any assumptions about the underlying single photoelectron distribution. We illustrate the use of this method through the calibration of a Hamamatsu R11410 photomultiplier tube and study the accuracy and precision of the method using Monte Carlo simulations. The method is found to have significantly reduced bias compared to conventional methods and works under a wide range of light intensities, making it suitable for the simultaneous calibration of large arrays of photomultiplier tubes where uniform illumination may not be possible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Statistical Analysis and Modeling of Occupancy Patterns in Open-Plan Offices using Measured Lighting-Switch Data

Occupancy profile is one of the driving factors behind discrepancies between the measured and simulated energy consumption of buildings. The frequencies of occupants leaving their offices and the corresponding durations of absences have significant impact on energy use and the operational controls of buildings. This study used statistical methods to analyze the occupancy status, based on measured lighting-switch data in five-minute intervals, for a total of 200 open-plan (cubicle) offices. Five typical occupancy patterns were identified based on the average daily 24-hour profiles of the presence of occupants in their cubicles. These statistical patterns were represented by a one-square curve, a one-valley curve, a two-valley curve, a variable curve, and a flat curve. The key parameters that define the occupancy model are the average occupancy profile together with probability distributions of absence duration, and the number of times an occupant is absent from the cubicle. The statistical results also reveal that the number of absence occurrences decreases as total daily presence hours decrease, and the duration of absence from the cubicle decreases as the frequency of absence increases. The developed occupancy model captures the stochastic nature of occupants moving in and out of cubicles, and can be used to generate a more realistic occupancy schedule. This is crucial for improving the evaluation of the energy saving potential of occupancy based technologies and controls using building simulations. Finally, to demonstrate the use of the occupancy model, weekday occupant schedules were generated and discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Determination of Critical Experiment Correlations Using the Sampler Sequence Within SCALE 6.2

The validation of neutron transport methods used in nuclear criticality safety analyses is required by consensus American National Standards Institute/American Nuclear Society (ANSI/ANS) standards. In the last decade, there has been an increased interest in correlations among critical experiments used in validation that have shared physical attributes and which impact the independence of each measurement. The statistical methods included in many of the frequently cited guidance documents on performing validation calculations incorporate the assumption that all individual measurements are independent, so little guidance is available to practitioners on the topic. Typical guidance includes recommendations to select experiments from multiple facilities and experiment series in an attempt to minimize the impact of correlations or common-cause errors in experiments. Recent efforts have been made both to determine the magnitude of such correlations between experiments and to develop and apply methods for adjusting the bias and bias uncertainty to account for the correlations. This paper describes recent work performed at Oak Ridge National Laboratory using the Sampler sequence from the SCALE code system to develop experimental correlations using a Monte Carlo sampling technique. Sampler will be available for the first time with the release of SCALE 6.2, and a brief introduction to the methods used to calculate experiment correlations within this new sequence is presented in this paper. Techniques to utilize these correlations in the establishment of upper subcritical limits are the subject of a companion paper and will not be discussed here. Example experimental uncertainties and correlation coefficients are presented for a variety of low-enriched uranium water-moderated lattice experiments selected for use in a benchmark exercise by the Working Party on Nuclear Criticality Safety Subgroup on Uncertainty Analysis in Criticality Safety Analyses. The results include studies on the effect of fuel rod pitch on the correlations, and some observations are also made regarding difficulties in determining experimental correlations using the Monte Carlo sampling technique.

42 ENGINEERING↗

Nuclear Forensics for Irradiated Materials using Kernel Regression Models

The ultimate purpose of nuclear forensics is to locate the origin of nuclear and other radioactive materials out of regulatory control used in nuclear security events such as classical forensics. For this purpose, some specific characteristics of interdicted materials (referred to as 'signatures') should be defined to compare the known sample database. In some cases, involved with irradiated material, the signatures could be specific amount of fission product inventory depending on reactor operational histories such as reactor type, initial enrichment, burn up rate of nuclear fuel and cooling period after irradiation in the reactor. In order to make inference model for irradiated material for nuclear forensics, we suggested 3 ways as follows; (i) analyzing ORIGEN produced nuclear substances for the fission product inventory, (ii) classifying the range of reactor type, (iii) predicting the operational history from the fission product inventory. In terms of nuclear substance analysis, the construction of spent fuel database has been internationally carried out since ITWG (Nuclear Smuggling International Technical Working Group) was established in 1995. However, enough sample data cannot be obtained in Korea to determine reactor type and operational histories because analyzing nuclear substances have been limited due to the international regulation. Thus, this study does not mention how to obtain mass or ratios of nuclides for the spent fuel. We just have generated simulation sample data as a fission product inventory using ORIGEN to construct spent fuel database. When unidentified radioactive materials are discovered, it is assumed that mass or ratios of the nuclides are analyzed by certain methods which are available in Korea as well as other countries. Then, a reactor type is determined, and finally, regression model can locate the origin or source of the radioactive materials by inferring operational histories using the fission product inventory. There are some studies on the classification of reactor type using statistical methods. As a part of predicting the operational history, this paper focuses on the development of spent fuel inference algorithm for nuclear forensics to estimate reactor operational histories that reflect characteristics of a reactor from the fission product inventory. The spent fuel inference algorithm for nuclear forensics has been developed on the basis of Kernel Regression (KR) which can conditionally generate the estimated output data by giving weight depending on geometric distance between sample data and input data. Also the KR which comprises Auto-Associative KR and Inferential KR have some benefits that can estimate only using data without assumption for specific physical model and re-learning process. Auto-associative KR (AAKR) was used to sort out outliers of input data and Inferential KR (IKR) was carried out to predict the operational histories for spent fuel. All of regression algorithms were performed in R programming tool. From the validation of both AAKR and IKR, it is expected that kernel regression has enough accuracy to be applied to nuclear forensics for spent fuel. Once the nuclear substance is measured to fill the fission product inventory with a certain reactor type, this kernel regression algorithm would predict the operational histories of spent fuel with high accuracy. Finally, this information is expected to be useful to find the origin of irradiated materials. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Determination of critical experiment correlations using the sampler sequence within scale 6.2 - 14602

The validation of neutron transport methods used in nuclear criticality safety analyses is required by consensus American National Standards Institute/American Nuclear Society (ANSI/ANS) standards. In the last decade, there has been an increased interest in correlations among critical experiments used in validation that have shared physical attributes and which impact the independence of each measurement. The statistical methods included in many of the frequently cited guidance documents on performing validation calculations incorporate the assumption that all individual measurements are independent, so little guidance is available to practitioners on the topic. Typical guidance includes recommendations to select experiments from multiple facilities and experiment series in an attempt to minimize the impact of correlations or common-cause errors in experiments. Recent efforts have been made both to determine the magnitude of such correlations between experiments and to develop and apply methods for adjusting the bias and bias uncertainty to account for the correlations. This paper describes recent work performed at Oak Ridge National Laboratory using the Sampler sequence from the SCALE code system to develop experimental correlations using a Monte Carlo sampling technique. Sampler will be available for the first time with the release of SCALE 6.2, and a brief introduction to the methods used to calculate experiment correlations within this new sequence is presented in this paper. Techniques to utilize these correlations in the establishment of upper subcritical limits are the subject of a companion paper and will not be discussed here. Example experimental uncertainties and correlation coefficients are presented for a variety of low-enriched uranium water-moderated lattice experiments selected for use in a benchmark exercise by the Working Party on Nuclear Criticality Safety Subgroup on Uncertainty Analysis in Criticality Safety Analyses. The results include studies on the effect of fuel rod pitch on the correlations, and some observations are also made regarding difficulties in determining experimental correlations using the Monte Carlo sampling technique. (authors)

42 ENGINEERING↗

TESTING TESTS ON ACTIVE GALACTIC NUCLEI MICROVARIABILITY

Literature on optical and infrared microvariability in active galactic nuclei (AGNs) reflects a diversity of statistical tests and strategies to detect tiny variations in the light curves of these sources. Comparison between the results obtained using different methodologies is difficult, and the pros and cons of each statistical method are often badly understood or even ignored. Even worse, improperly tested methodologies are becoming more and more common, and biased results may be misleading with regard to the origin of the AGN microvariability. This paper intends to point future research on AGN microvariability toward the use of powerful and well-tested statistical methodologies, providing a reference for choosing the best strategy to obtain unbiased results. Light curves monitoring has been simulated for quasars and for reference and comparison stars. Changes for the quasar light curves include both Gaussian fluctuations and linear variations. Simulated light curves have been analyzed using {chi}{sup 2} tests, F tests for variances, one-way analyses of variance and C-statistics. Statistical Type I and Type II errors, which indicate the robustness and the power of the tests, have been obtained in each case. One-way analyses of variance and {chi}{sup 2} prove to be powerful and robust estimators for microvariations, while the C-statistic is not a reliable methodology and its use should be avoided.

79 ASTRONOMY AND ASTROPHYSICS↗

Generating data ensembles over a model grid from sparse climate measurements.

Parameterizations in high-end climate models can be evaluated with observed climate and meteorological data. Often this evaluation is achieved by averaging measured quantities over time and space to match the spatial and temporal resolution of a gridded climate model without any regard for the statistical errors in doing so. We present a statistical method to interpolate sparsely located surface measurements into a uniform spatial grid representative of global and regional models of the atmosphere and climate. This method provides estimates of mean values over the entire domain containing the measurement sites as well as the uncertainty in the estimated quantities at the grid locations through multiple simulations to create 'data ensembles.' We demonstrate this method using measurements of surface sensible heat flux over the southern Great Plains region gathered through the Department of Energy's Atmospheric Radiation Measurement (ARM) program. Application to the numerous other climate variables measured through the ARM program and the development of a software tool to streamline data management and implementation of the statistical models is also discussed.

54 ENVIRONMENTAL SCIENCES↗

SU-E-J-248: Comparative Study of Two Image Registration for Image-Guided Radiation Therapy in Esophageal Cancer

Purpose: Image-guided radiation therapy (IGRT) is one of the major treatment of esophageal cancer. Gray value registration and bone registration are two kinds of image registration, the purpose of this work is to compare which one is more suitable for esophageal cancer patients. Methods: Twenty three esophageal patients were treated by Elekta Synergy, CBCT images were acquired and automatically registered to planning kilovoltage CT scans according to gray value or bone registration. The setup errors were measured in the X, Y and Z axis, respectively. Two kinds of setup errors were analysed by matching T test statistical method. Results: Four hundred and five groups of CBCT images were available and the systematic and random setup errors (cm) in X, Y, Z directions were 0.35, 0.63, 0.29 and 0.31, 0.53, 0.21 with gray value registration, while 0.37, 0.64, 0.26 and 0.32, 0.55, 0.20 with bone registration, respectively. Compared with bone registration and gray value registration, the setup errors in X and Z axis have significant differences. In Y axis, both measurement comparison results of T value is 0.256 (P value > 0.05); In X axis, the T value is 5.287(P value < 0.05); In Z axis, the T value is −5.138 (P value < 0.05). Conclusion: Gray value registration is recommended in image-guided radiotherapy for esophageal cancer and the other thoracic tumors. Manual registration could be applied when it is necessary. Bone registration is more suitable for the head tumor and pelvic tumor department where composed of redundant interconnected and immobile bone tissue.

60 APPLIED LIFE SCIENCES↗

Improved Subseasonal Forecasting of Extreme Polar Vortices Using Machine Learning

Our research was focused on forecasting the position and shape of the winter stratospheric polar vortex at a subseasonal timescale of 15 days in advance. To achieve this, we employed both statistical and neural network machine learning techniques. The analysis was performed on 42 winter seasons of reanalysis data provided by NASA giving us a total of 6,342 days of data. The state of the polar vortex for determined by using geometric moments to calculate the centroid latitude and the aspect ratio of an ellipse fit onto the vortex. Timeseries for thirty additional precursors were calculated to help improve the predictive capabilities of the algorithm. Feature importance of these precursors was performed using random forest to measure the predictive importance and the ideal number of precursors. Then, using the precursors identified as important, various statistical methods were tested for predictive accuracy with random forest and nearest neighbor performing the best. An echo state network, a type of recurrent neural network that features sparsely connected hidden layer and a reduced number of trainable parameters that allows for rapid training and testing, was also implemented for the forecasting problem. Hyperparameter tuning was performed for each methods using a subset of the training data. The algorithms were trained and tuned on the first 41 years of data, then tested for accuracy on the final year. In general, the centroid latitude of the polar vortex proved easier to predict than the aspect ratio across all algorithms. Random forest outperformed other statistical forecasting algorithms overall but struggled to predict extreme values. Forecasting from echo state network suggested a strong predictive capability past 15 days, but further work is required to fully realize the potential of recurrent neural network approaches.

54 ENVIRONMENTAL SCIENCES↗

TU-F-12A-09: GLCM Texture Analysis for Normal-Tissue Toxicity: A Prospective Ultrasound Study of Acute Toxicity in Breast-Cancer Radiotherapy

Purpose: To evaluate the morphologic and structural integrity of the breast glands using sonographic textural analysis, and identify potential early imaging signatures for radiation toxicity following breast-cancer radiotherapy (RT). Methods: Thirty-eight patients receiving breast RT participated in a prospective ultrasound imaging study. Each participant received 3 ultrasound scans: 1 week before RT (baseline), and at 6-week and 3-month follow-ups. Patients were imaged with a 10-MHz ultrasound on the four quadrant of the breast. A second order statistical method of texture analysis, called gray level co-occurrence matrix (GLCM), was employed to assess RT-induced breast-tissue toxicity. The region of interest (ROI) was 28 mm × 10 mm in size at a 10 mm depth under the skin. Twenty GLCM sonographic features, ratios of the irradiated breast and the contralateral breast, were used to quantify breast-tissue toxicity. Clinical assessment of acute toxicity was conducted using the RTOG toxicity scheme. Results: Ninety-seven ultrasound studies (776 images) were analyzed; and 5 out of 20 sonographic features showed significant differences (p < 0.05) among the baseline scans, the acute toxicity grade 1 and 2 groups. These sonographic features quantified the degree of tissue damage through homogeneity, heterogeneity, randomness, and symmetry. Energy ratio value decreased from 108±0.05 (normal) to 0.99±0.05 (Grade 1) and 0.84±0.04 (Grade 2); Entropy ratio value increased from 1.01±0.01 to 1.02±0.01 and 1.04±0.01; Contrast ratio value increased from 1.03±0.03 to 1.07±0.06 and 1.21±0.09; Variance ratio value increased from 1.06±0.03 to 1.20±0.04 and 1.42±0.10; Cluster Prominence ratio value increased from 0.98±0.02 to 1.01±0.04 and 1.25±0.07. Conclusion: This work has demonstrated that the sonographic features may serve as imaging signatures to assess radiation-induced normal tissue damage. While these findings need to be validated in a larger cohort, they suggest that ultrasound imaging may be used to improve early detection of normal-tissue toxicity in breast-cancer RT.

60 APPLIED LIFE SCIENCES↗