Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Static Electricity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

270 records · Page 15

In-situ monitoring for liquid metal jetting using a millimeter-wave impedance diagnostic

Abstract This article presents a millimeter-wave diagnostic for the in-situ monitoring of liquid metal jetting additive manufacturing systems. The diagnostic leverages a T-junction waveguide device to monitor impedance changes due to jetted metal droplets in real time. An analytical formulation for the time-domain T-junction operation is presented and supported with a quasi-static full-wave electromagnetic simulation model. The approach is evaluated experimentally with metallic spheres of known diameters ranging from 0.79 to 3.18 mm. It is then demonstrated in a custom drop-on-demand liquid metal jetting system where effective droplet diameters ranging from 0.8 to 1.6 mm are detected. Experimental results demonstrate that this approach can provide information about droplet size, timing, and motion by monitoring a single parameter, the reflection coefficient amplitude at the input port. These results show the promise of the impedance diagnostic as a reliable in-situ characterization method for metal droplets in an advanced manufacturing system.

42 ENGINEERING↗

Poly(vinylferrocene) as an Ionomer and Sulfur-Confining Additive for Lithium–Sulfur Batteries

Lithium-sulfur (Li-S) batteries are promising owing to their high energy density, environmental benignity, and low cost. Most of the commonly used binders in Li-S battery cathodes are inert and have no significant effect on the challenges of sulfur as a cathode material, such as the polysulfide shuttle effect, low ionic/electronic conductivity, and a sluggish redox reaction. In this work, we demonstrate the use of poly(vinylferrocene) (PvFc) as a binder additive that can effectively increase the ionic conductivity of the cathode and act as a sulfide confining agent. Electrochemical tests performed with PvFc as part of the binder mixture used to cast the cathodes demonstrate an increase in rate capability and cycle life when compared to the baseline samples. Ionic conductivity measurements and X-ray photoelectron spectroscopy suggest that the π-cation molecular interaction between the cyclopentadienyl rings from ferrocene and Li + act like an ion couple with ferrocene acting as a static, covalently bound acceptor of Li + ions that enhances their mobility through the cathode. This coupled with the affinity between the ferrocenyl cations and the Li salt anions, which provides more distribution of counterions for Li + movement and improves accessibility to the cathode S reservoir, make PvFc a promising ionomer for Li-S batteries. In addition, the π-cation bonds between cyclopentadienyl and lithium polysulfides produce a sulfide confining effect that mitigates capacity fade through polysulfide dissolution. Furthermore, this work demonstrates an expansion in the utility of PvFc as a component in Li-ion batteries, which so far is mostly limited to use as an active material in organometallic batteries.

25 ENERGY STORAGE↗

High Yield nTOF Spec A and NP Filter Holders Static and Seismic Analysis

The Neutron Time-of-Flight (nTOF) detectors located in the Alcove and at the North Pole (Spec A and Spec NP respectively) need filtering in the beam path to enable them to take data at NIF yields above 5MJ. The filtering consists of 12cm of filter material divided into four, 3cm thick “pucks.” The pucks are 7cm in diameter. Each puck is mounted into a rotatable stage, also called a Filter Flipper, that can bring it into and out of the beam path, see Figure 1-1. These stages are bolted onto a plate that connects the filter stages to the mounting hardware used to position them in the NIF Target Bay. The top-level filter mount assemblies will be permanently mounted in the facility; removal is possible if needed for NIF maintenance, but the design intent is for the assemblies to remain in their locations after alignment is completed.

42 ENGINEERING↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Shunt-Connected FACTS and Synchronous Condensers

In recent years, the electric-transmission system has undergone a significant transformation marked by a greater integration of renewable-energy sources like wind and solar, the phasing out of thermal generation plants, and a concerted effort towards electrifying energy consumption. To keep pace with the integration of renewable-energy sources and the escalating demands of industries and households, it is imperative to expand and modernize the existing power infrastructure. These upgrades are essential to maintain grid stability, enhance power delivery, and boost overall efficiency of the system. However, challenges have emerged with the growing complexity of power grids, particularly in the realms of voltage control, transient stability, and power-quality management.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Probing topological phases in a perturbed Kane-Mele model via RKKY interaction: Application to monolayer jacutingaite Pt 2 ⁢HgSe 3

Quantum spin Hall insulators (QSHIs) leverage strong spin-orbit coupling (SOC) for efficient spin manipulation, making them promising for spintronics. Here, in this study, we investigate the noncollinear Ruderman-Kittel-Kasuya-Yosida (RKKY) interaction between two magnetic impurities in a perturbed Kane-Mele model with strong SOC, relevant to monolayer jacutingaite Pt 2 ⁢HgSe 3 as a prominent QSHI. Following the previous studies that mainly focused on the model and its general applications, we provide a systematic examination of the effects of various perturbations and strong spin-orbit hybridizations, which drive phase transitions that have not been extensively explored before. By incorporating these perturbations into the model and accurately accounting for spin-orbit hybridizations through spin-space Green's functions and the RKKY interactions, we uncover distinct, relative (rather than absolute) signatures of different phase transitions. These phase transitions are induced by both static and dynamic perturbations on the magnetic impurities. Notably, we identify additional phases emerging from the interplay with the magnetic substrate. All these influence the switching between ferromagnetic and antiferromagnetic, as well as clockwise and counterclockwise magnetic interactions. Our results provide a practical way to track topological phases through magnetic properties, offering new insights into phase control and spin manipulation in QSHIs.

Kane-Mele model↗

Effect of organic electroactive crystallites in a dielectric matrix on the electrical properties of a polymer dielectric

In this work, the effects of inserting chargeable α-quaterthiophene (α4T) crystallites in polystyrene (PS) multilayers used as a transistor gate and capacitor dielectric were investigated. X-ray diffraction (XRD), scanning electron microscopy with energy dispersive x-ray spectroscopy (SEM/EDS), and confocal microscopy indicated the formation of α4T crystallites in the PS matrix. A modified saturation-regime current voltage relationship was used to estimate organic field-effect transistor (OFET) threshold voltage V TH shifting, and in turn the quantities of stored charge that were observed as a result of dielectric charging. The crystallites increased the maximum charge storage capacity as well as the charge retention capability of the dielectrics. Kelvin probe force microscopy (KPFM) showed that charges were localized near the α4T crystallites upon charging. Trilayer experiments validated the charge retention improvement of α4T crystallite-embedded PS dielectrics. The crystallites also improved breakdown characteristics in PS used as a capacitor dielectric, suggesting their application to storage capacitors in addition to OFET logic.

25 ENERGY STORAGE↗

Signature Analysis Utilizing a Dynamic Molten Salt Reactor Model for MC&A

Moving from traditional fixed fuel nuclear reactor systems to a mobile, dynamic fuel system that has dissolved special nuclear material in a molten salt is a paradigm shift in several respects. One major consideration is how to develop effective nuclear material controls and accounting for these novel reactor systems. The Molten Salt Reactor Experiment is one example of a critical molten salt system and provided a significant reference library based on the documented effort. But it was low thermal power that was not intended to reflect a commercial scale electricity production design. Therefore, to facilitate and assist vendors with domestic licensing considerations, research is underway to identify methods that could be used for domestic safeguards approaches for these novel reactor systems. This research presents the results of a signature analysis of data generated from three simulated scenarios using the molten salt demonstration reactor model defined in the Transient Simulation Framework of Reconfigurable Modules. Each scenario provides 1 hour isotope inventories over a 180 day period. The scenarios investigated provide test cases to examine if direct gamma-ray spectroscopy of the fuel can be used to identify changes comparing a base case (no reactivity control and fixed fission contribution) to an insertion of reactivity (10 pcm no change in fission composition) and a change in fission composition. The analysis demonstrates that monitoring the total count rate in a highly collimated high-resolution photon energy spectrum is sensitive to perturbations imposed into the reactor model. The total photon count rate changes ≈2% for the fission composition change and ≈4.5% for the reactivity insertion compared to the base case. However, both scenarios show an increase in the total photon count rate. The total photon count rate can be used to identify changes due to power (number of fissions) but not due to a change in the material undergoing fission. To distinguish between the two cases of increased power, the photon spectrum would require an intensive analysis technique. A photon peak count rate ratio analysis could be used to identify changes in the fissile material fission generation in the core through identification of a static peak that shows little variation to the source of fission and a highly varying peak. The photon peak strength will ultimately be determined by the isotope’s fission yield. A preliminary analysis investigating the coupling of the isotope’s fission yield and its concentration in the fuel salt derived from the modeling has been performed. A ratio analysis of the photon peak count rates of 140 La to 99 Mo demonstrated that the reactivity insertion creates a distinct difference in the ratio compared to the fission composition change scenario.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Benchmarking the Suitability of Novec$^{\mathrm{TM}}$ 4710 for Application in Flux Compression Generators

Here, an experimental study evaluated the feasibility of replacing traditional insulating gases such as SF 6 with C 4 F 7 N (3M TM , Novec 4710) in flux compression generator (FCG) applications. Currently available data indicate that Novec 4710 could offer certain performance benefits over SF 6 . However, the available literature is focused on low frequency (50–60 Hz) and dc at static pressures. To evaluate the performance of Novec 4710 under the pulsed dynamic pressure and temperature conditions found in an FCG, we report a performance comparison between three sets of identical FCGs using air, SF 6 , and Novec 4710 as the insulating gas. The generators used in this study had a single stage, directly seeded design with an armature diameter of 25 mm and a stator diameter of 46 mm. To highlight the performance of the different gases rather than any wire insulation, the stator was constructed with uninsulated wire. Furthermore, the generators were seeded aggressively, making the performance difference between the different gases more apparent. The performance was monitored with a pair of differential Rogowski coils that captured the generators’ di / dt while also using high-speed videography to capture possible gaseous breakdown signatures. The data gathered during this study indicate that Novec 4710 performs at least as well as SF 6 in FCG applications, if not significantly better.

42 ENGINEERING↗

Digital Twin for Hydropower System Object Modeling: Alder Dam (FY2023)

Hydropower is the world's largest source of renewable electricity, and hydropower plants are distributed all over the world. Typical major components of a hydropower plant are the governor, excitation, generator, thrust bearing, hydraulic turbine, transformer, the main lead, metering and control, tailwater depression, and dissolved oxygen. For each component, various measures are taken. The measurements are acquired by various heterogeneous systems, including standalone sensors, programmable logic controllers (PLC), Supervisory control and data acquisition (SCADA), Internet of Things (IoT), and data acquisition and integration platforms such as OSI/PI. The measured data are often archived within the plant by a data management platform, and many institutions have cloud-based archive systems, such as Hydropower Research Institution (HRI), U.S. Army Corps of Engineers (USACE), and Columbia River Data Access in Real Time (DART). Object Modeling is a general framework for designing information systems. It focuses on objects, the actions they perform, and the messages they send to one another to cause those actions to be taken. The major differences among object modeling, network modeling, data modeling, and process modeling are that in the first we focus on the actions in response to information, objects which form the system, the actions they perform, and how they pass information to one another, while in the second we concentrate on where, when and how much information is moved, while in the third we focus on what information is moved and where it is moved, while in the last we focus on how it is moved and when it is moved. Object modeling was developed basically as a method to develop object-oriented systems and to support object-oriented programming. It describes the static structure of the system. The object Modeling Technique is easy to draw and use. That is why we choose object modeling to connect physical hydropower plants to Digital Twin. It recognizes the objects and the relationship between them. It identifies the attributes and functions of each class. Dynamic Modeling: It explains how objects respond to events. Functional Modeling indicates the processes executed in an object and how data changes when it moves to objects. It has been used in many applications like telecommunication, transportation, etc.

13 HYDRO ENERGY↗

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects (Final Technical Report)

The number of commercial coal, gas, and nuclear projects built over the past 100 years number in the thousands. As such, there is a large database, available to a wide range of commercial engineering contractors, on proven designs. In essence, unsuccessful designs have, through generations of iterations, been identified and then deleted from further consideration. In contrast, the number of commercial parabolic trough projects using nitrate salt for the thermal storage media is perhaps 60. Further, the number of commercial central receiver projects using nitrate salt as the working fluid is on the order of 20, including estimates for China. Given the relative immaturity of salt technology, and commercial pressures to successfully bid new solar projects into a mature electricity market, solar projects often promise more than has been delivered. The Design Basis Document / Owner’s Technical Specification is a first step in the iteration process. The report describes the successful features of commercial projects, outlines a range equipment and system failures in projects that didn’t operate as intended, and provides a draft set of design changes intended to correct the known problems. The product of the study is 3 volumes of technical material; one volume is on parabolic trough technologies; a second is on central receiver technologies, and the third is on potential design changes to parabolic trough and central receiver projects. The 3 volumes, which total some 590 pages, can be found at https://www.solardynllc.com/csp-plant-technologies. One of the principal topics in the report is the use of functional or prescriptive specifications. Functional specifications describe what the equipment needs to do, consistent with the minimum legal requirements of the local jurisdictions. The details of how this is to be accomplished is developed by the engineering contractor. Prescriptive specifications, which are developed by the Owner, prescribe to the engineering contractor how the functional requirements are to be met. This arrangement ensures that the favorable experience from a previous project is repeated. One example is the design code for the hot salt tank in central receiver projects. The closest design basis is API Standard 650 Welded Steel Tanks for Oil Storage. However, the maximum design temperature in API 650 is 260 °C. As such, solar projects have typically adopted a hybrid Code approach, in which allowable material stresses are taken from ASME Section II Materials. Further, since the tanks experience daily changes in temperature and in (static) pressure, and since portions of the tank can operate at stresses beyond the elastic range, the low cycle fatigue life of the tank is conducted using the rules of Section VIII Division 2. However, in a recent study by NREL, the principal damage mechanism was identified as creep rather than fatigue. Further, design stresses permitted under Section VIII Division 2, corresponding to a fatigue life of 30 years, result in projected creep lifetimes of only 2 to 5 years. An alternate design approach, prescribed by the Owner, would be based on Code sections intended for high temperature service in the creep regime. A candidate is Section III Division 5. Granted, this is a nuclear code section, and it’s use would not likely be mandated by local jurisdictions. However, the effects of creep have been deemed to be of sufficient importance that one nuclear project developer, and one central receiver project developer, have stipulated in the tank design specification that the equipment be designed to the requirements of Section III Division 5.

14 SOLAR ENERGY↗

Distinguishing the gapped and Weyl semimetal scenario in ZrTe 5 : insights from an effective two-band model

In this work, we study the static and dynamic transport properties of a low-energy two-band model proposed previously in Martino et al. [PRL 122, 217402 (2019)], with an anisotropic in-plane linear momentum dependence and a parabolic out-of-plane dispersion. The model is extended to include a negative band gap, which leads to the emergence of a Weyl semimetal (WSM) state, as opposed to the gapped semimetal (GSM) state when the band gap is positive. Furthermore, we calculate and compare the zero- and finite-frequency transport properties of the GSM and WSM cases. The DC properties that are calculated for the GSM and WSM cases are Drude spectral weight, mobility, and resistivity. We determine their dependence on the Fermi energy and crystal direction. The in- and out-of-plane optical conductivities are calculated in the limit of the vanishing interband relaxation rate for both semimetals. The main common features are an ω 1/2 in-plane and ω 3/2 out-of-plane frequency dependence of the optical conductivity. We seek particular features related to the charge transport that could unambiguously point to one ground state over the other, based on the comparison with the experiment. Differences between the WSM and GSM are in principle possible only at extremely low carrier concentrations and at low temperatures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tri-Level Scheduling Model Considering Residential Demand Flexibility of Aggregated HVACs and EVs Under Distribution LMP

Residential loads, especially heating, ventilation and air conditioners (HVACs) and electric vehicles (EVs), have great potentials to provide demand flexibility which is an attribute of grid-interactive efficient buildings (GEB). Under this new paradigm, first, EV and HVAC aggregator models are developed in this paper to represent the fleet of GEBs, in which the aggregated parameters are obtained based on a new approach of data generation and least squares parameter estimation (DG-LSPE), which can deal with heterogeneous HVACs. Then, a tri-level bidding and dispatching framework is established based on competitive distribution operation with distribution locational marginal price (DLMP). Furthermore, the first two levels form a bilevel model to optimize the aggregators’ payment and to represent the interdependency between load aggregators and the distribution system operator (DSO) using DLMP, and the third level is to dispatch the optimal load aggregation to all residents by the proposed priority list-based demand dispatching algorithm. Finally, case studies on a modified IEEE 33-Bus system illustrate three main technical reasons of payment reduction due to demand flexibility: load shift, DLMP step changes, and power losses. They can be used as general guidelines for better decision-making for future planning and operation of demand response programs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wind Loading on Parabolic Trough Collectors: Wind and Structural Loads Measurements at an Operational Powerplant

Concentrated Solar Power (CSP) is a promising method for using solar power for electricity generation with thermal energy storage for industrial applications. Solar collectors constitute almost 1/3 of the total cost of the power plant. One of the primary drivers of unrealiability of these collectors is wind-driven loading of mirrors, support structures, and drives. To date, the design of the solar collector structures has relied on data from wind tunnels that do not adequately capture the dynamic effects observed at scale. NREL initiated a field measurement campaign at the operational Nevada Solar One (NSO) parabolic trough powerplant. At this plant, parabolic trough solar collectors track the sun from east to west in the course of a day and face varying wind loads depending on the wind properties and the angle of the troughs. The aim of the project is a detailed characterization of prevailing wind and turbulence conditions and resulting operational loads on parabolic troughs, providing insights into structural dynamic response, and generating a comprehensive wind-loading dataset for validating simulations of wind loading on collector structures. The measurements at NSO consist of sonic anemometers on masts at different heights to characterize the incoming flow and conditions at four trough rows at the edge of the trough field. In addition, a Doppler Lidar scans the horizontal plane above the troughs. The wind measurements at NSO have been continuously collecting data since October 2021 and are combined with structural load measurements that started in November 2022. The load measurements were installed on the same four outermost trough rows and include support structure bending moments, drive torque moments, dynamic accelerations of the spaceframe, mirror displacement, and tilt angles. Measurements are planned to continue until May 2023, providing a first-of-a-kind, high-resolution multi-month dataset of combined wind and load measurements. In this presentation, we show first results of the measurement campaign. Based on the measurements, we identified three main factors altering the flow over the parabolic troughs: Wind speed, wind direction, and the angle of the parabolic troughs. Most interactions between incoming wind and the trough field are observed when the wind blows perpendicular to the trough rows. In this case, the first rows experience the highest wind speed and block the downwind rows, creating conditions with decreased wind speed and enhanced turbulence within the trough field. Also, turbulent length scales are smaller after the first row. This leads to the highest static loads (bending and torque moments) at the first row but potentially increased dynamic loads within the field. We illustrate our findings with case studies focused on different wind conditions and will present fatigue analysis to highlight the impact of wind-driven loads on collector structures.

CSP collectors↗

Investigating Electron Conductivity Regimes in the Bacterial Cytochrome Wire OmcS

The anaerobic bacterium Geobacter sulfurreducens produces extracellular, electronically conductive cytochrome polymer wires that are conductive over micron length scales. Structure models from cryo-electron microscopy data show OmcS wires form a linear chain of hemes along the protein wire axis, which is proposed as the structural basis supporting their electronic properties. However, the mechanism by which this heme arrangement supports long-range electronic conduction remains unknown. Structure models from cryo-electron microscopy data show these wires form a linear chain of hemes along the protein wire axis, which is proposed as the structural basis supporting their electronic properties. Existing computational models using static heme redox potentials and coupling energies fail to explain experimental observations, predicting conductances 10,000 to 100,000 times lower than measured values. Here, we investigate how dynamic disorder affects site energies, interheme coupling, and long-range electronic conductivity within these cytochrome wires. We introduce an approach to extract charge carrier site information directly from Kohn–Sham density functional theory, without employing projector schemes, and show that site and coupling energies are highly sensitive to changes in interheme geometry and the surrounding electrostatic environment. Unlike models that incorporate dynamic disorder as a thermally averaged quantity, our quantum charge carrier model incorporates proxies for dynamic disorder through decoherence corrections, yielding predicted diffusion coefficient closer to what is expected from experiment and comparable with other organic-based electronic materials. Based on these simulations, we propose that the instantaneous fluctuations of the local electrostatic environment can transiently lift energy degeneracies and delocalize charge carriers. Furthermore, these studies reveal how incorporating dynamic fluctuations associated with the environment resolves the discrepancy between theory and experiment in microbial cytochrome wires and highlight design principles for bioinspired, heme-based conductive materials.

Bioinorganic chemistry↗

Advanced Transmission Technologies – GETs and HPCs Session 2: Advanced Power Flow Control and Transmission Topology Optimization

The INL TADA GETs Cohort Session 2, held on November 7, 2025, conducted in collaboration with ScottMadden, focused on two core Advanced Transmission Technologies (ATTs): Advanced Power Flow Control (APFC) and Transmission Topology Optimization (TTO). These technologies are pivotal in enhancing grid flexibility, reliability, and cybersecurity resilience. APFC, particularly through modular FACTS devices like Modular Static Synchronous Series Compensators (M-SSSCs), enables dynamic voltage injection to reroute power flows. The session highlighted the deployment benefits of APFC, such as rapid installation, minimal civil works, and re-deployability. Regulatory drivers like FERC Order 2023 mandate the inclusion of Grid-Enhancing Technologies (GETs) in interconnection studies. Case studies from Central Hudson, CAISO, and National Grid (UK) demonstrated APFC’s effectiveness in congestion relief and cost savings. The session also addressed cybersecurity concerns, including firmware vulnerabilities, SCADA integration risks, and supply chain dependencies. Participants engaged in interactive exercises to rank cybersecurity and supply chain risks, emphasizing the need for robust digital assurance strategies. TTO involves software-based reconfiguration of transmission networks to optimize power flow without new infrastructure. The session showcased its operational value, with examples from SPP, PJM, and MISO showing significant congestion cost reductions. Cybersecurity vulnerabilities were discussed, particularly in API security and software supply chains, referencing incidents like SolarWinds and attacks on Danish utilities. Digital assurance exercises explored worst-case scenarios, attack paths, and mitigation responsibilities between vendors and utilities. Reliability challenges such as algorithm stability, vendor dependency, and operator trust were also examined. Cross-cutting themes emphasized the importance of digital assurance tools, including Software Bills of Materials (SBOMs) and hardware-in-loop testing. Human performance, training, and operational confidence were identified as critical enablers of technology adoption. The session concluded with a preview of Session 3, which will focus on High Performance Conductors (HPCs) and risk-based cybersecurity tools. Session 2 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Importance of finite-size corrections for accurate ab initio modeling of carrier capture at semiconductor defects: A case study of substitutional C N in GaN

In ab initio studies of carrier-capture processes in defective semiconductor materials, the single-effective-mode formalism and the static-coupling approximation have become the predominant theoretical approaches for determining carrier-capture coefficients. The single-mode formalism relies on accurate nonequilibrium defect energies obtained from density-functional theory (DFT), where required inputs are a series of configurationally displaced, defect-containing supercells obtained using an interpolative ansatz, and where the DFT outputs are corresponding total energies that have traditionally been postprocessed using a long-established ground-state formulation of finite-size corrections and defect-formation energies. This formulation remains commonly used even though the defects that form a configuration-coordinate (CC) diagram typically exist as structures that are displaced from the ground state. To remedy this inconsistency, Kumagai has recently proposed novel methods for implementing finite-size corrections specifically intended for DFT calculations of the defect energies used to construct CC diagrams and implement the single-mode formalism [Y. Kumagai, Phys. Rev. B 107, L220101 (2023)]. Kumagai's approach builds on the latest finite-size-correction methods introduced to describe vertical charge-state transitions for charge-localizing point defects in semiconductors and insulators [T. Gake et al., Phys. Rev. B 101, 020102 (2020); S. Falletta et al., Phys. Rev. B 102, 041115 (2020)]. The newly identified finite-size artifact treated in these studies is the polarization charge induced on a configurationally frozen defect and its subsequent interaction with a vertical transition in charge state. In this work, we evaluate Kumagai's proposed methodology by applying it in a high-precision DFT study of carrier capture by substitutional C N in GaN, a well-characterized and technologically relevant defect and material. We have rigorously calculated C N defect energies across various supercell sizes for each defect configuration and charge state on the hole-capture CC diagram of C N (𝑞=−1), enabling a direct comparison of the slopes of the defect energies versus inverse cell size with those predicted by Kumagai. The most consequential prediction of Kumagai's method is that these slopes distinctly vary as the square of the linear-interpolation parameter used to construct the nonequilibrium defect configurations. Our results quantitatively support this prediction. Moreover, with these new finite-size corrections and multiple-cell-size DFT calculations in place, we find that the classical energy barrier for hole capture by C N (𝑞=−1) in GaN decreases to 0.092–0.127 eV. This finding confirms the recent ≈ 0.1 eV prediction of Reshchikov based on the weak temperature dependence for hole capture observed in photoluminescence experiments [M. A. Reshchikov, J. Appl. Phys. 129, 121101 (2021)]. These results stand in stark contrast to previously calculated barriers of 0.486 and 0.73 eV, which also used the single-mode formalism but were obtained by instead using ground-state-based finite-size corrections. Our reduced classical barrier for capture increases the temperature-dependent hole-capture coefficient of a C N (𝑞=−1) defect by more than two to four orders of magnitude for temperatures of 100–600 K, compared to the previous 0.486 eV results. While other defects may not be as dramatically affected as here, we suggest that incorporating proper finite-size corrections for the vertical-transition-like states embedded within CC diagrams is an essential, yet previously unrecognized, component of accurate modeling of carrier-capture when using the single-effective-mode formalism.

dielectric properties↗