Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Quantitative x-ray magnetic circular dichroism mapping with high spatial resolution full-field magnetic transmission soft x-ray spectro-microscopy

The spectroscopic analysis of X-ray magnetic circular dichroism (XMCD), which serves as strong and element-specific magnetic contrast in full-field magnetic transmission soft x-ray microscopy, is shown to provide information on the local distribution of spin (S) and orbital (L) magnetic moments down to a spatial resolution of 25 nm limited by the x-ray optics used in the x-ray microscope. The spatially resolved L/S ratio observed in a multilayered (Co 0.3 nm/Pt 0.5 nm) × 30 thin film exhibiting a strong perpendicular magnetic anisotropy decreases significantly in the vicinity of domain walls, indicating a non-uniform spin configuration in the vertical profile of a domain wall across the thin film. Quantitative XMCD mapping with x-ray spectro-microscopy will become an important characterization tool for systems with topological or engineered magnetization inhomogeneities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Final Technical Report for DE-FG02-06ER15835: Chemical Imaging with 100nm Spatial Resolution: Combining High Resolution Flurosecence Microscopy and Ion Mobility Mass Spectrometry

We have combined, in a single instrument, high spatial resolution optical microscopy with the chemical specificity and conformational selectivity of ion mobility mass spectrometry. We discuss the design and construction of this apparatus as well as our efforts in applying this technique to thin films of molecular semiconductor materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computer-based classification accuracy due to the spatial resolution using per-point versus per-field classification techniques

Data sets simulating three different spatial resolutions (SR's) are computed from data with a 15-m nominal SR that were obtained with NASA's Thermatic Mapper Simulator from an altitude of about 6 km. The classification accuracies (CA's) achieved with the data of each of the four different SR's using a per-point Gaussian maximum likelihood classifier (GMLC) are intercompared. The CA's obtained using simulated 30-m SR data with the per-point GMLC are compared with the CA's achieved with a per-field classifier. It is found that: (1) the use of successively higher SR data resulted in lower overall CA's for classifications with the per-point GMLC, especially in cover classes associated with relatively higher spectral variability across adjacent pixels; (2) higher CA's were achieved using the per-field classifier with 30-m SR data than were achieved with the per-point GMLC; and (3) the largest increases in CA's were achieved with the per-field classifier in cover classes associated with relatively high levels of spectral variability across adjacent pixels.

Latty, R. S.↗

High-Spatial-Resolution OH and CH2O PLIF Visualization in a Dual-Mode Scramjet Combustor

A high-spatial-resolution planar laser-induced fluorescence (PLIF) imaging system was constructed and used to image a cavity-stabilized, premixed ethylene-air flame. The flame was created within a continuous flow, electrically-heated supersonic combustion facility consisting of a Mach 2 nozzle, an isolator with flush-wall fuel injectors, a combustor with a cavity flameholder of height 9 mm and optical access, and an extender. Tests were conducted at total temperature 1200 K, total pressure 300 kPa, equivalence ratio near 0.4 in the combustor, and Mach number near 0.6 in the combustor. A frequency-doubled Nd:YAG laser pumped a dye laser, which produced light at 283.55 nm. The beam was shaped into a light sheet with full width half-maximum 25 microns, which illuminated a streamwise plane that bisected the cavity. An intensified camera system imaged OH in this plane with a square 6.67 mm field of view and in-plane resolution 39 microns. Images were taken between the backward-facing step and 120 mm downstream of the step. OH structures as small as 110 microns were observed. CH2O was excited using 352.48 nm light; the smallest observed CH2O structures were approximately 200 microns wide. Approximately 15,000 images per species were processed and used to compute composite images.

Geipel, Clayton M.↗

Monitoring and Modeling the Rapid Evolution of Earth's Newest Volcanic Island: Hunga Tonga Hunga Ha'apai (Tonga) Using High Spatial Resolution Satellite Observations

We have monitored a newly erupted volcanic island in the Kingdom of Tonga, unofficially known as Hunga Tonga Hunga Ha'apai, by means of relatively frequent high spatial resolution (~50 cm) satellite observations. The new ~1.8 km 2(exp) island formed as a tuff cone over the course of a month‐long hydromagmatic eruption in early 2015 in the Tonga‐Kermadec volcanic arc. Such ash‐dominated eruptions usually produce fragile subaerial landscapes that wash away rapidly due to marine erosion, as occurred nearby in 2009. Our measured rates of erosion are ~0.00256 km 3(exp) / year from derived digital topographic models. Preliminary measurements of the topographic expression of the primary tuff cone over ~30 months suggest a lifetime of ~19 years (and potentially up to 42 years). The ability to measure details of a young island's landscape evolution using satellite remote sensing has not previously been possible at these spatial and temporal resolutions.

Garvin, J. B.↗

Monitoring and Modeling the Rapid Evolution of Earth's Newest Volcanic Island: Hunga Tonga Hunga Ha'apai (Tonga) Using High Spatial Resolution Satellite Observations

We have monitored a newly erupted volcanic island in the Kingdom of Tonga, unofficially known as Hunga Tonga Hunga Ha'apai , by means of relatively frequent high spatial resolution (~50 cm) satellite observations. The new ~1.8 km 2 island formed as a tuff cone over the course of a month-long hydromagmatic eruption in early 2015 in the Tonga-Kermadec volcanic arc. Such ash-dominated eruptions usually produce fragile subaerial landscapes that wash away rapidly due to marine erosion, as occurred nearby in 2009. Our measured rates of erosion are ~0.00256 km 3 /year from derived digital topographic models. Preliminary measurements of the topographic expression of the primary tuff cone over ~30 months suggest a lifetime of ~19 years (and potentially up to 42 years). The ability to measure details of a young island's landscape evolution using satellite remote sensing has not previously been possible at these spatial and temporal resolutions.

47 OTHER INSTRUMENTATION↗

Low-Z target optimization for spatial resolution improvement in megavoltage imaging

Purpose: Recently, several authors have shown contrast improvements in megavoltage portal imaging and cone-beam computed tomography using low atomic number (Z) targets. This work compliments previous studies by investigating the effects of varying different beam production parameters including target atomic number, target thickness, and incident electron energy on spatial resolution. Methods: Target materials of beryllium, aluminum, and tungsten were investigated over a range of thicknesses between 10% and 100% of the continuous slowing down approximation range of electrons. Incident electron kinetic energies of 4.5 and 7.0 MeV were used, in conjunction with custom targets installed above the carousel of a modern radiotherapy linear accelerator. Monte Carlo simulations of the accelerator were constructed and compared to the experimental results. Results: The results showed that thinner targets, as well higher incident electron energies, generally produce more favorable modulation transfer function (MTF) curves. Due to an MTF dependence of the detector system on the photon energy, the experimental results showed that low-Z targets produced superior MTF curves. Simulations showed 14.5% and 21.5% increases in f{sub 50} for the 7.0 and 4.5 MeV targets (Al; 60%R{sub %CSDA}), respectively, when moved from the carousel to the location of the clinical target. f{sub 50} values for the custom targets were compared to the clinical 6 MV beam and were found to be between 10.4% lower (4.5 MeV/W) and 15.5% higher (7.0 MeV/Be). Conclusions: Integration of low-Z external targets into the treatment head of a medical linear was achieved with only minor modifications. It was shown that reasonably high resolution images on par or better than those acquired with the clinical 6 MV beam can be achieved using external low-Z targets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Spatial Resolution Mid-IR Imaging of V838 Monocerotis: Evidence of New Circumstellar Dust Creation

We report high spatial resolution 11.2 and 18.1 mm imaging of V838 Monocerotis obtained with Gemini Observatory's Michelle instrument in 2007 March. Strong emission is observed from the unresolved stellar core of V838 Mon in our Gemini imagery and is confirmed by Spitzer MIPS 24 micron imaging obtained in 2007 April. The 2007 flux density of the unresolved mid-infrared emission component is approx.2 times brighter than that observed in 2004. No clear change in the net amount of 24 mm extended emission is observed between the 2004 and 2007 epoch Spitzer imagery. We interpret these data as evidence that V838 Mon has experienced a new circumstellar dust creation event. We suggest that this newly created dust has condensed from the expanding ejecta produced from V838 Mon's 2002 outburst events and is most likely clumpy. We speculate that one (or more) of these clumps might have passed through the line of sight in late 2006, producing the brief multiwavelength photometric event reported by H. Bond in 2006 and U. Munari et al. in 2007b. We detect no evidence of extended emission above a level of approx.1 mJy at 11.2 microns and approx.7 mJy at 18.1 microns over radial distances of 1860-93,000 AU (0.3" - 15.0") from the central source. Using the simple assumption that ejecta material expands at a constant velocity of 300-500 km/s, this gap of thermal emission suggests that no significant prior circumstellar dust production events have occurred within the past approx.900-1500 yr.

Wisniewski, John P.↗

Visualization of High Resolution Spatial Mass Spectrometric Data during Acquisition

Mass Spectrometric Imaging (IMS) allows the generation of 2D ion density maps that help visualize molecules present in sections of tissues and cells. The combination of spatial and mass resolution results in large and complex data sets that require powerful and efficient analysis and interpretation. In this paper, a graphical user interface (GUI) that can visualize the large data during data acquisition itself is presented. The program also has the ability to perform processing and analysis of the dataset. The various functions of the GUI including visualization of mass spectra, generation of 2D maps for selected species, manipulation of the heat maps, and peak identification are also presented.

Thomas, Mathew↗

Matrix recrystallization for MALDI-MS imaging of maize lipids at high-spatial resolution

Matrix recrystallization is optimized and applied to improve lipid ion signals in maize embryos and leaves. A systematic study was performed varying solvent and incubation time. During this study, unexpected side reactions were found when methanol was used as a recrystallization solvent, resulting in the formation of a methyl ester of phosphatidic acid. Furthermore, using an optimum recrystallization condition with isopropanol, there is no apparent delocalization demonstrated with a transmission electron microscopy (TEM) pattern and maize leaf images obtained at 10 μm spatial resolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Validation of modelled imaging plates sensitivity to 1-100 keV x-rays and spatial resolution characterisation for diagnostics for the “PETawatt Aquitaine Laser”

Thanks to their high dynamic range and ability to withstand electromagnetic pulse, imaging plates (IPs) are commonly used as passive detectors in laser-plasma experiments. In the framework of the development of the diagnostics for the Petawatt Aquitaine Laser facility, we present an absolute calibration and spatial resolution study of five different available types of IP (namely, MS-SR-TR-MP-ND) performed by using laser-induced K-shell X-rays emitted by a solid silver target irradiated by the laser ECLIPSE at CEntre Lasers Intenses et Applications. In addition, IP sensitivity measurements were performed with a 160 kV X-ray generator at CEA DAM DIF, where the absolute response of IP SR and TR has been calibrated to X-rays in the energy range 8-75 keV with uncertainties of about 15%. Finally, the response functions have been modeled in Monte Carlo GEANT4 simulations in order to reproduce experimental data. Simulations enable extrapolation of the IP response functions to photon energies from 1 keV to 1 GeV, of interest, e.g., for laser-driven radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial resolution and downwash velocity corrections for multiple-hole pressure probes in complex flows

Correction schemes for finite spatial resolution and induced downwash velocity are presented which have application to the measurement of complex three-dimensional flow fields using five-hole angle-type pressure probes. In the study, induced downwash velocity is assumed to be proportional to the transverse gradients of streamwise velocity. The present correction schemes are validated by application to flows including vortices embedded within turbulent boundary layers and flows in a curved channel with 1.27-cm width, a 40-to-1 aspect ratio, and 59.7 cm of convex surface curvature.

Ligrani, P. M.↗

Seismic Study of the Subsurface Structure and Dynamics of the Solar Interior from High Spatial Resolution Observations

We have carried out the data reduction and analysis of Mt. Wilson 60' solar tower high spatial resolution observations. The reduction of the 100-day-long summer of 1990 observation campaign in terms of rotational splittings was completed leading to an excess of 600,000 splittings. The analysis of these splittings lead to a new inference of the solar internal rotation rate as a function of depth and latitude.

Korzennik, Sylvain G.↗

A new technique for X-ray spectroscopy of laser-plasmas with simultaneous 2D spatial resolution over a broad spectral range

Over the past few years, a new X-ray diagnostic technique has been developed by the group of the Intense Laser Irradiation Laboratory of the CNR in Pisa. Here we give a brief description of this new diagnostic tool, which basically allows X-ray spectroscopy of laser-produced plasmas to be performed over a broad photon energy range with a simultaneous 2D spatial resolution. An outline of recent results will be also given in order to assess the diagnostic capabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High spatial resolution X-ray and gamma ray imaging system using diffraction crystals

A method and a device for high spatial resolution imaging of a plurality of sources of x-ray and gamma-ray radiation are provided. The device comprises a plurality of arrays, with each array comprising a plurality of elements comprising a first collimator, a diffracting crystal, a second collimator, and a detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of total column water vapor in the atmosphere at high spatial resolution from AVIRIS data using spectral curve fitting and band ratioing techniques

Techniques are developed for quantitative retrievals of high spatial resolution column atmospheric water vapor that is largely contained in the lower portion of the troposphere. One method consists of curve fitting observed spectra with simulated spectra in the 1.14 microns or the 0.94 micron water vapor band absorption region. The other method is a simple band ratioing technique, which requires less computer time than the curve fitting method. The advantage of the technique over humidity sounding by IR emission measurements is that the retrieved column water vapor amounts over land surfaces have significantly higher precision.

Gao, Bo-Cai↗

Science with High Spatial Resolution Far-Infrared Data

The goal of this workshop was to discuss new science and techniques relevant to high spatial resolution processing of far-infrared data, with particular focus on high resolution processing of IRAS data. Users of the maximum correlation method, maximum entropy, and other resolution enhancement algorithms applicable to far-infrared data gathered at the Infrared Processing and Analysis Center (IPAC) for two days in June 1993 to compare techniques and discuss new results. During a special session on the third day, interested astronomers were introduced to IRAS HIRES processing, which is IPAC's implementation of the maximum correlation method to the IRAS data. Topics discussed during the workshop included: (1) image reconstruction; (2) random noise; (3) imagery; (4) interacting galaxies; (5) spiral galaxies; (6) galactic dust and elliptical galaxies; (7) star formation in Seyfert galaxies; (8) wavelet analysis; and (9) supernova remnants.

Terebey, Susan↗

Large area, high spatial resolution tracker for new generation of high luminosity experiments in Hall A at Jefferson Lab

In 2014 the CEBAF electron accelerator at Jefferson Lab (JLab) will deliver a longitudinally polarized (up to 85%), high intensity (up to 100 μA) beam with maximum energy of 12 GeV, twice the present value. To exploit the new opportunities that the energy upgrade will offer, a new spectrometer (Super BigBite - SBS) is under development, featuring very forward angle, large acceptance and ability to operate in high luminosity environment. The tracking system of SBS will consist of large area (40×150 cm2 and 50×200 cm2), high spatial resolution (better than 100 μm) chambers based on the GEM technology and 2 small (10×20 cm) Silicon Strip Detector planes. The design of the GEM chambers and its sub-components such as the readout electronics is resented here.

43 PARTICLE ACCELERATORS↗