Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spares”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Deterministic direct aperture optimization using multiphase piecewise constant segmentation

Purpose Direct aperture optimization (DAO) attempts to incorporate machine constraints in the inverse optimization to eliminate the post‐processing steps in fluence map optimization (FMO) that degrade plan quality. Current commercial DAO methods utilize a stochastic or greedy approach to search a small aperture solution space. In this study, we propose a novel deterministic direct aperture optimization that integrates the segmentation of fluence map in the optimization problem using the multiphase piecewise constant Mumford‐Shah formulation. Methods The Mumford‐Shah based direct aperture optimization problem was formulated to include an L2‐norm dose fidelity term to penalize differences between the projected dose and the prescribed dose, an anisotropic total variation term to promote piecewise continuity in the fluence maps, and the multiphase piecewise constant Mumford‐Shah function to partition the fluence into pairwise discrete segments. A proximal‐class, first‐order primal‐dual solver was implemented to solve the large scale optimization problem, and an alternating module strategy was implemented to update fluence and delivery segments. Three patients of varying complexity—one glioblastoma multiforme (GBM) patient, one lung (LNG) patient, and one bilateral head and neck (H&N) patient with 3 PTVs—were selected to test the new DAO method. For each patient, 20 non‐coplanar beams were first selected using column generation, followed by the Mumford‐Shah based DAO (DAO MS ). For comparison, a popular and successful approach to DAO known as simulated annealing—a stochastic approach—was replicated. The simulated annealing DAO (DAO SA ) plans were then created using the same beam angles and maximum number of segments per beam. PTV coverage, PTV homogeneity , and OAR sparing were assessed for each plan. In addition, high dose spillage, defined as the 50% isodose volume divided by the tumor volume, as well as conformity, defined as the van't Riet conformation number, were evaluated. Results DAO MS achieved essentially the same OAR doses compared with the DAO SA plans for the GBM case. The average difference of OAR D max and D mean between the two plans were within 0.05% of the plan prescription dose. The lung case showed slightly improved critical structure sparing using the DAO MS approach, where the average OAR D max and D mean were reduced by 3.67% and 1.08%, respectively, of the prescription dose. The DAO MS plan substantially improved OAR dose sparing for the H&N patient, where the average OAR D max and D mean were reduced by over 10% of the prescription dose. The DAO MS and DAO SA plans were comparable for the GBM and LNG PTV coverage, while the DAO MS plan substantially improved the H&N PTV coverage, increasing D99 by 6.98% of the prescription dose. For the GBM and LNG patients, the DAO MS and DAO SA plans had comparable high dose spillage but slightly worse conformity with the DAO MS approach. For the H&N plan, DAO MS was considerably superior in high dose spillage and conformity to the DAO SA . The deterministic approach is able to solve the DAO problem substantially faster than the simulated annealing approach, with a 9.5‐ to 40‐fold decrease in total solve time, depending on the patient case. Conclusions A novel deterministic direct aperture optimization formulation was developed and evaluated. It combines fluence map optimization and the multiphase piecewise constant Mumford‐Shah segmentation into a unified framework, and the resulting optimization problem can be solved efficiently. Compared to the widely and commercially used simulated annealing DAO approach, it showed comparable dosimetry behavior for simple plans, and substantially improved OAR sparing, PTV coverage, PTV homogeneity, high dose spillage, and conformity for the more complex head and neck plan.

Nguyen, Dan↗

Four-Dimensional Computed Tomography-Based Treatment Planning for Intensity-Modulated Radiation Therapy and Proton Therapy for Distal Esophageal Cancer

Purpose: To compare three-dimensional (3D) and four-dimensional (4D) computed tomography (CT)-based treatment plans for proton therapy or intensity-modulated radiation therapy (IMRT) for esophageal cancer in terms of doses to the lung, heart, and spinal cord and variations in target coverage and normal tissue sparing. Methods and Materials: The IMRT and proton plans for 15 patients with distal esophageal cancer were designed from the 3D average CT scans and then recalculated on 10 4D CT data sets. Dosimetric data were compared for tumor coverage and normal tissue sparing. Results: Compared with IMRT, median lung volumes exposed to 5, 10, and 20 Gy and mean lung dose were reduced by 35.6%, 20.5%, 5.8%, and 5.1 Gy for a two-beam proton plan and by 17.4%, 8.4%, 5%, and 2.9 Gy for a three-beam proton plan. The greater lung sparing in the two-beam proton plan was achieved at the expense of less conformity to the target (conformity index [CI], 1.99) and greater irradiation of the heart (heart-V40, 41.8%) compared with the IMRT plan(CI, 1.55, heart-V40, 35.7%) or the three-beam proton plan (CI, 1.46, heart-V40, 27.7%). Target coverage differed by more than 2% between the 3D and 4D plans for patients with substantial diaphragm motion in the three-beam proton and IMRT plans. The difference in spinal cord maximum dose between 3D and 4D plans could exceed 5 Gy for the proton plans partly owing to variations in stomach gas filling. Conclusions: Proton therapy provided significantly better sparing of lung than did IMRT. Diaphragm motion and stomach gas-filling must be considered in evaluating target coverage and cord doses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Helical Tomotherapy Versus Conventional Intensity-Modulated Radiation Therapy for Primary Chemoradiation in Cervical Cancer Patients: An Intraindividual Comparison

Purpose: To compare intensity-modulated radiotherapy (IMRT) delivered by helical tomotherapy (HT) with conventional IMRT for primary chemoradiation in cervical cancer patients. Methods and Materials: Twenty cervical cancer patients undergoing primary chemoradiation received radiation with HT; 10 patients underwent pelvic irradiation (PEL) and 10 extended-field irradiation (EXT). For treatment planning, the simultaneously integrated boost (SIB) concept was applied. Tumor, pelvic, with or without para-aortic lymph nodes were defined as planning target volume A (PTV-A) with a prescribed dose of 1.8/50.4 Gy (28 fractions). The SIB dose for the parametrium (PTV-B), was 2.12/59.36 Gy. The lower target constraints were 95% of the prescribed dose in 95% of the target volume, and the upper dose constraint was 107%. The irradiated small-bowel volumes were kept as low as possible. For every HT plan, a conventional IMRT plan was calculated and compared with regard to dose-volume histogram, conformity index and conformity number, and homogeneity index. Results: Both techniques allowed excellent target volume coverage and sufficient SB sparing. Conformity index and conformity number results for both PTV-A and PTV-B, homogeneity index for PTV-B, and SB sparing for V45, V50, Dmax, and D1% were significantly better with HT. SB sparing was significantly better for conventional IMRT at low doses (V10). Conclusions: Both HT and conventional IMRT provide optimal treatment of cervical cancer patients. The HT technique was significantly favored with regard to target conformity, homogeneity, and SB sparing. Randomized trials are needed to assess the oncological outcome, toxicity, and clinical relevance of these differences.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of a Knowledge-Based Planning Solution for Head and Neck Cancer

Purpose: Automated and knowledge-based planning techniques aim to reduce variations in plan quality. RapidPlan uses a library consisting of different patient plans to make a model that can predict achievable dose-volume histograms (DVHs) for new patients and uses those models for setting optimization objectives. We benchmarked RapidPlan versus clinical plans for 2 patient groups, using 3 different libraries. Methods and Materials: Volumetric modulated arc therapy plans of 60 recent head and neck cancer patients that included sparing of the salivary glands, swallowing muscles, and oral cavity were evenly divided between 2 models, Model{sub 30A} and Model{sub 30B}, and were combined in a third model, Model{sub 60}. Knowledge-based plans were created for 2 evaluation groups: evaluation group 1 (EG1), consisting of 15 recent patients, and evaluation group 2 (EG2), consisting of 15 older patients in whom only the salivary glands were spared. RapidPlan results were compared with clinical plans (CP) for boost and/or elective planning target volume homogeneity index, using HI{sub B}/HI{sub E} = 100 × (D2% − D98%)/D50%, and mean dose to composite salivary glands, swallowing muscles, and oral cavity (D{sub sal}, D{sub swal}, and D{sub oc}, respectively). Results: For EG1, RapidPlan improved HI{sub B} and HI{sub E} values compared with CP by 1.0% to 1.3% and 1.0% to 0.6%, respectively. Comparable D{sub sal} and D{sub swal} values were seen in Model{sub 30A}, Model{sub 30B}, and Model{sub 60}, decreasing by an average of 0.1, 1.0, and 0.8 Gy and 4.8, 3.7, and 4.4 Gy, respectively. However, differences were noted between individual organs at risk (OARs), with Model{sub 30B} increasing D{sub oc} by 0.1, 3.2, and 2.8 Gy compared with CP, Model{sub 30A}, and Model{sub 60}. Plan quality was less consistent when the patient was flagged as an outlier. For EG2, RapidPlan decreased D{sub sal} by 4.1 to 4.9 Gy on average, whereas HI{sub B} and HI{sub E} decreased by 1.1% to 1.5% and 2.3% to 1.9%, respectively. Conclusions: RapidPlan knowledge-based treatment plans were comparable to CP if the patient's OAR-planning target volume geometry was within the range of those included in the models. EG2 results showed that a model including swallowing-muscle and oral-cavity sparing can be applied to patients with only salivary gland sparing. This may allow model library sharing between institutes. Optimal detection of inadequate plans and population of model libraries requires further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Theoretical Benefits of Dynamic Collimation in Pencil Beam Scanning Proton Therapy for Brain Tumors: Dosimetric and Radiobiological Metrics

Purpose: To quantify the dosimetric benefit of using a dynamic collimation system (DCS) for penumbra reduction during the treatment of brain tumors by pencil beam scanning proton therapy (PBS PT). Methods and Materials: Collimated and uncollimated brain treatment plans were created for 5 patients previously treated with PBS PT and retrospectively enrolled in an institutional review board–approved study. The in-house treatment planning system, RDX, was used to generate the plans because it is capable of modeling both collimated and uncollimated beamlets. The clinically delivered plans were reproduced with uncollimated plans in terms of target coverage and organ at risk (OAR) sparing to ensure a clinically relevant starting point, and collimated plans were generated to improve the OAR sparing while maintaining target coverage. Physical and biological comparison metrics, such as dose distribution conformity, mean and maximum doses, normal tissue complication probability, and risk of secondary brain cancer, were used to evaluate the plans. Results: The DCS systematically improved the dose distribution conformity while preserving the target coverage. The average reduction of the mean dose to the 10-mm ring surrounding the target and the healthy brain were 13.7% (95% confidence interval [CI] 11.6%-15.7%; P<.0001) and 25.1% (95% CI 16.8%-33.4%; P<.001), respectively. This yielded an average reduction of 24.8% (95% CI 0.8%-48.8%; P<.05) for the brain necrosis normal tissue complication probability using the Flickinger model, and 25.1% (95% CI 16.8%-33.4%; P<.001) for the risk of secondary brain cancer. A general improvement of the OAR sparing was also observed. Conclusion: The lateral penumbra reduction afforded by the DCS increases the normal tissue sparing capabilities of PBS PT for brain cancer treatment while preserving target coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Potential of Proton Therapy to Reduce Acute Hematologic Toxicity in Concurrent Chemoradiation Therapy for Esophageal Cancer

Purpose: Radiation therapy dose escalation using a simultaneous integrated boost (SIB) is predicted to improve local tumor control in esophageal cancer; however, any increase in acute hematologic toxicity (HT) could limit the predicted improvement in patient outcomes. Proton therapy has been shown to significantly reduce HT in lung cancer patients receiving concurrent chemotherapy. Therefore, we investigated the potential of bone marrow sparing with protons for esophageal tumors. Methods and Materials: Twenty-one patients with mid-esophageal cancer who had undergone conformal radiation therapy (3D50) were selected. Two surrogates for bone marrow were created by outlining the thoracic bones (bone) and only the body of the thoracic vertebrae (TV) in Eclipse. The percentage of overlap of the TV with the planning treatment volume was recorded for each patient. Additional plans were created retrospectively, including a volumetric modulated arc therapy (VMAT) plan with the same dose as for 3D50; a VMAT SIB plan with a dose prescription of 62.5 Gy to the high-risk subregion within the planning treatment volume; a reoptimized TV-sparing VMAT plan; and a proton therapy plan with the same SIB dose prescription. The bone and TV dose metrics were recorded and compared across all plans and variations with respect to PTV and percentage of overlap for each patient. Results: The 3D50 plans showed the highest bone mean dose and TV percentage of volume receiving ≥30 Gy (V{sub 30Gy}) for each patient. The VMAT plans irradiated a larger bone V{sub 10Gy} than did the 3D50 plans. The reoptimized VMAT62.5 VT plans showed improved sparing of the TV volume, but only the proton plans showed significant sparing for bone V{sub 10Gy} and bone mean dose, especially for patients with a larger PTV. Conclusions: The results of the present study have shown that proton therapy can reduced bone marrow toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Review of the Poster 'Dosimetric Comparison of Gamma Knife Radiosurgery vs. {sup 125}I Plaque Brachytherapy in a Cohort of Choroidal Melanomas'

Historically, treatment for choroidal melanomas was surgical enucleation. Currently, treatment methods such as stereotactic radiosurgery and brachytherapy are being used to spare the eye. The poster 'Dosimetric Comparison of Gamma Knife Radiosurgery vs. I-125 Plaque Brachytherapy in a Cohort of Choroidal Melanomas' presented at ASTRO 2007 by Anderson et al. provides a comparison of these methods. The dose to disk, fovea and lens in 29 patients from a simulated I-125 treatment and a delivered Gamma Knife radiosurgery was compared. Thirty Gy was prescribed to the 50% Isodose line in the radiosurgery and 85 Gy was prescribed to the apex of the tumor in the I-125 simulation. It was found that the Gamma Knife spares the disk better in 59% of the tumors, including those {>=}6.5 mm in height; spares the fovea better in 69% of the tumors, including those {>=}5.5 mm; and spares lens better in only 30% of the tumors, with no distinction in size. Tumor location was not taken into account for this study, which could explain the variations in smaller tumors. For larger tumors, gamma knife will protect most organs at risk more effectively. This study shows how a tumor's parameters can be used in selecting treatment modality.

61 RADIATION PROTECTION AND DOSIMETRY↗

The use of RapidArc volumetric-modulated arc therapy to deliver stereotactic radiosurgery and stereotactic body radiotherapy to intracranial and extracranial targets

Twenty-three targets in 16 patients treated with stereotactic radiosurgery (SRS) or stereotactic body radiotherapy (SBRT) were analyzed in terms of dosimetric homogeneity, target conformity, organ-at-risk (OAR) sparing, monitor unit (MU) usage, and beam-on time per fraction using RapidArc volumetric-modulated arc therapy (VMAT) vs. multifield sliding-window intensity-modulated radiation therapy (IMRT). Patients underwent computed tomography simulation with site-specific immobilization. Magnetic resonance imaging fusion and optical tracking were incorporated as clinically indicated. Treatment planning was performed using Eclipse v8.6 to generate sliding-window IMRT and 1-arc and 2-arc RapidArc plans. Dosimetric parameters used for target analysis were RTOG conformity index (CI{sub RTOG}), homogeneity index (HI{sub RTOG}), inverse Paddick Conformity Index (PCI), D{sub mean} and D5-D95. OAR sparing was analyzed in terms of D{sub max} and D{sub mean}. Treatment delivery was evaluated based on measured beam-on times delivered on a Varian Trilogy linear accelerator and recorded MU values. Dosimetric conformity, homogeneity, and OAR sparing were comparable between IMRT, 1-arc RapidArc and 2-arc RapidArc plans. Mean beam-on times {+-} SD for IMRT and 1-arc and 2-arc treatments were 10.5 {+-} 7.3, 2.6 {+-} 1.6, and 3.0 {+-} 1.1 minutes, respectively. Mean MUs were 3041, 1774, and 1676 for IMRT, 1-, and 2-arc plans, respectively. Although dosimetric conformity, homogeneity, and OAR sparing were similar between these techniques, SRS and SBRT fractions treated with RapidArc were delivered with substantially less beam-on time and fewer MUs than IMRT. The rapid delivery of SRS and SBRT with RapidArc improved workflow on the linac with these otherwise time-consuming treatments and limited the potential for intrafraction organ and patient motion, which can cause significant dosimetric errors. These clinically important advantages make image-guided RapidArc useful in the delivery of SRS and SBRT to intracranial and extracranial targets.

61 RADIATION PROTECTION AND DOSIMETRY↗

Critical dose and toxicity index of organs at risk in radiotherapy: Analyzing the calculated effects of modified dose fractionation in non–small cell lung cancer

To increase the efficacy of radiotherapy for non–small cell lung cancer (NSCLC), many schemes of dose fractionation were assessed by a new “toxicity index” (I), which allows one to choose the fractionation schedules that produce less toxic treatments. Thirty-two patients affected by non resectable NSCLC were treated by standard 3-dimensional conformal radiotherapy (3DCRT) with a strategy of limited treated volume. Computed tomography datasets were employed to re plan by simultaneous integrated boost intensity-modulated radiotherapy (IMRT). The dose distributions from plans were used to test various schemes of dose fractionation, in 3DCRT as well as in IMRT, by transforming the dose-volume histogram (DVH) into a biological equivalent DVH (BDVH) and by varying the overall treatment time. The BDVHs were obtained through the toxicity index, which was defined for each of the organs at risk (OAR) by a linear quadratic model keeping an equivalent radiobiological effect on the target volume. The less toxic fractionation consisted in a severe/moderate hyper fractionation for the volume including the primary tumor and lymph nodes, followed by a hypofractionation for the reduced volume of the primary tumor. The 3DCRT and IMRT resulted, respectively, in 4.7% and 4.3% of dose sparing for the spinal cord, without significant changes for the combined-lungs toxicity (p < 0.001). Schedules with reduced overall treatment time (accelerated fractionations) led to a 12.5% dose sparing for the spinal cord (7.5% in IMRT), 8.3% dose sparing for V{sub 20} in the combined lungs (5.5% in IMRT), and also significant dose sparing for all the other OARs (p < 0.001). The toxicity index allows to choose fractionation schedules with reduced toxicity for all the OARs and equivalent radiobiological effect for the tumor in 3DCRT, as well as in IMRT, treatments of NSCLC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Technique for comprehensive head and neck irradiation using 3-dimensional conformal proton therapy

Owing to the technical and logistical complexities of matching photon and proton treatment modalities, we developed and implemented a technique of comprehensive head and neck radiation using 3-dimensional (3D) conformal proton therapy. A monoisocentric technique was used with a 30-cm snout. Cervical lymphatics were treated with 3 fields: a posterior-anterior field with a midline block and a right and a left posterior oblique field. The matchline of the 3 cervical nodal fields with the primary tumor site fields was staggered by 0.5 cm. Comparative intensity-modulated photon plans were later developed for 12 previously treated patients to provide equivalent target coverage, while matching or improving on the proton plans' sparing of organs at risk (OARs). Dosimetry to OARs was evaluated and compared by treatment modality. Comprehensive head and neck irradiation using proton therapy yielded treatment plans with significant dose avoidance of the oral cavity and midline neck structures. When compared with the generated intensity-modulated radiation therapy (IMRT) plans, the proton treatment plans yielded statistically significant reductions in the mean and integral radiation dose to the oral cavity, larynx, esophagus, and the maximally spared parotid gland. There was no significant difference in mean dose to the lesser-spared parotid gland by treatment modality or in mean or integral dose to the spared submandibular glands. A technique for cervical nodal irradiation using 3D conformal proton therapy with uniform scanning was developed and clinically implemented. Use of proton therapy for cervical nodal irradiation resulted in large volume of dose avoidance to the oral cavity and low dose exposure to midline structures of the larynx and the esophagus, with lower mean and integral dose to assessed OARs when compared with competing IMRT plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

IMRT planning and delivery incorporating daily dose from mega-voltage cone-beam computed tomography imaging

The technology of online mega-voltage cone-beam (CB) computed tomography (MV-CBCT) imaging is currently used in many institutions to generate a 3D anatomical dataset of a patient in treatment position. It utilizes an accelerator therapy beam, delivered with 200 deg. gantry rotation, and captured by an electronic portal imager to account for organ motion and setup variations. Although the patient dose exposure from a single volumetric MV-CBCT imaging procedure is comparable to that from standard double-exposure orthogonal portal images, daily image localization procedures can result in a significant dose increase to healthy tissue. A technique to incorporate the daily dose, from a MV-CBCT imaging procedure, in the IMRT treatment planning optimization process was developed. A composite IMRT plan incorporating the total dose from the CB was optimized with the objective of ensuring uniform target coverage while sparing the surrounding normal tissue. One head and neck cancer patient and four prostate cancer patients were planned and treated using this technique. Dosimetric results from the prostate IMRT plans optimized with or without CB showed similar target coverage and comparable sparing of bladder and rectum volumes. Average mean doses were higher by 1.6{+-}1.0 Gy for the bladder and comparable for the rectum (-0.3{+-}1.4 Gy). In addition, an average mean dose increase of 1.9{+-}0.8 Gy in the femoral heads and 1.7{+-}0.6 Gy in irradiated tissue was observed. However, the V{sub 65} and V{sub 70} values for bladder and rectum were lower by 2.3{+-}1.5% and 2.4{+-}2.1% indicating better volume sparing at high doses with the optimized plans incorporating CB. For the head and neck case, identical target coverage was achieved, while a comparable sparing of the brain stem, optic chiasm, and optic nerves was observed. The technique of optimized planning incorporating doses from daily online MV-CBCT procedures provides an alternative method for imaging IMRT patients. It allows for daily treatment modifications where other volumetric tomographic imaging techniques may not be feasible and/or available and where accurate patient localization with a high degree of precision is required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient geometry-driven information retrieval for IMRT treatment plan quality control

Purpose: Intensity modulated radiation therapy (IMRT) treatment plan quality depends on the planner's level of experience and the amount of time the planner invests in developing the plan. Planners often unwittingly accept plans when further sparing of the organs at risk (OARs) is possible. The authors propose a method of IMRT treatment plan quality control that helps planners to evaluate the doses of the OARs upon completion of a new plan. Methods: It is achieved by comparing the geometric configurations of the OARs and targets of a new patient with those of prior patients, whose plans are maintained in a database. They introduce the concept of a shape relationship descriptor and, specifically, the overlap volume histogram (OVH) to describe the spatial configuration of an OAR with respect to a target. The OVH provides a way to infer the likely DVHs of the OARs by comparing the relative spatial configurations between patients. A database of prior patients is built to serve as an external reference. At the conclusion of a new plan, planners search through the database and identify related patients by comparing the OAR-target geometric relationships of the new patient with those of prior patients. The treatment plans of these related patients are retrieved from the database and guide planners in determining whether lower doses delivered to the OARs in the new plan are feasible. Results: Preliminary evaluation is promising. In this evaluation, they applied the analysis to the parotid DVHs of 32 prior head-and-neck patients, whose plans are maintained in a database. Each parotid was queried against the other 63 parotids to determine whether a lower dose was possible. The 17 parotids that promised the greatest reduction in D{sub 50} (DVH dose at 50% volume) were flagged. These 17 parotids came from 13 patients. The method also indicated that the doses of the other nine parotids of the 13 patients could not be reduced, so they were included in the replanning process as controls. Replanning with an effort to reduce D{sub 50} was conducted on these 26 parotids. After replanning, the average reductions for D{sub 50} of the 17 flagged parotids and nine unflagged parotids were 6.6 and 1.9 Gy, respectively. These results demonstrate that the quality control method has accurately identified not only the parotids that require dose reductions but also those for which dose reductions are marginal. Originally, 11 of out the 17 flagged parotids did not meet the Radiation Therapy Oncology Group sparing goal of V(30 Gy)<50%. Replanning reduced them to three. Additionally, PTV coverage and OAR sparing of the original plans were compared to those of the replans by using pairwise Wilcoxon p test. The statistical comparisons show that replanning compromised neither PTV coverage nor OAR sparing. Conclusions: This method provides an effective quality control mechanism for evaluating the DVHs of the OARs. Adoption of such a method will advance the quality of current IMRT planning, providing better treatment plan consistency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A method for deriving a 4D-interpolated balanced planning target for mobile tumor radiotherapy

Purpose: Tumor control and normal tissue toxicity are strongly correlated to the tumor and normal tissue volumes receiving high prescribed dose levels in the course of radiotherapy. Planning target definition is, therefore, crucial to ensure favorable clinical outcomes. This is especially important for stereotactic body radiation therapy of lung cancers, characterized by high fractional doses and steep dose gradients. The shift in recent years from population-based to patient-specific treatment margins, as facilitated by the emergence of 4D medical imaging capabilities, is a major improvement. The commonly used motion-encompassing, or internal-target volume (ITV), target definition approach provides a high likelihood of coverage for the mobile tumor but inevitably exposes healthy tissue to high prescribed dose levels. The goal of this work was to generate an interpolated balanced planning target that takes into account both tumor coverage and normal tissue sparing from high prescribed dose levels, thereby improving on the ITV approach. Methods: For each 4DCT dataset, 4D deformable image registration was used to derive two bounding targets, namely, a 4D-intersection and a 4D-composite target which minimized normal tissue exposure to high prescribed dose levels and maximized tumor coverage, respectively. Through definition of an ''effective overlap volume histogram'' the authors derived an ''interpolated balanced planning target'' intended to balance normal tissue sparing from prescribed doses with tumor coverage. To demonstrate the dosimetric efficacy of the interpolated balanced planning target, the authors performed 4D treatment planning based on deformable image registration of 4D-CT data for five previously treated lung cancer patients. Two 4D plans were generated per patient, one based on the interpolated balanced planning target and the other based on the conventional ITV target. Plans were compared for tumor coverage and the degree of normal tissue sparing resulting from the new approach was quantified. Results: Analysis of the 4D dose distributions from all five patients showed that while achieving tumor coverage comparable to the ITV approach, the new planning target definition resulted in reductions of lung V{sub 10}, V{sub 20}, and V{sub 30} of 6.3% {+-} 1.7%, 10.6% {+-} 3.9%, and 12.9% {+-} 5.5%, respectively, as well as reductions in mean lung dose, mean dose to the GTV-ring and mean heart dose of 8.8% {+-} 2.5%, 7.2% {+-} 2.5%, and 10.6% {+-} 3.6%, respectively. Conclusions: The authors have developed a simple and systematic approach to generate a 4D-interpolated balanced planning target volume that implicitly incorporates the dynamics of respiratory-organ motion without requiring 4D-dose computation or optimization. Preliminary results based on 4D-CT data of five previously treated lung patients showed that this new planning target approach may improve normal tissue sparing without sacrificing tumor coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated generation of IMRT treatment plans for prostate cancer patients with metal hip prostheses: Comparison of different planning strategies

Purpose: To compare IMRT planning strategies for prostate cancer patients with metal hip prostheses.Methods: All plans were generated fully automatically (i.e., no human trial-and-error interactions) using iCycle, the authors' in-house developed algorithm for multicriterial selection of beam angles and optimization of fluence profiles, allowing objective comparison of planning strategies. For 18 prostate cancer patients (eight with bilateral hip prostheses, ten with a right-sided unilateral prosthesis), two planning strategies were evaluated: (i) full exclusion of beams containing beamlets that would deliver dose to the target after passing a prosthesis (IMRT{sub remove}) and (ii) exclusion of those beamlets only (IMRT{sub cut}). Plans with optimized coplanar and noncoplanar beam arrangements were generated. Differences in PTV coverage and sparing of organs at risk (OARs) were quantified. The impact of beam number on plan quality was evaluated.Results: Especially for patients with bilateral hip prostheses, IMRT{sub cut} significantly improved rectum and bladder sparing compared to IMRT{sub remove}. For 9-beam coplanar plans, rectum V{sub 60Gy} reduced by 17.5%{+-} 15.0% (maximum 37.4%, p= 0.036) and rectum D{sub mean} by 9.4%{+-} 7.8% (maximum 19.8%, p= 0.036). Further improvements in OAR sparing were achievable by using noncoplanar beam setups, reducing rectum V{sub 60Gy} by another 4.6%{+-} 4.9% (p= 0.012) for noncoplanar 9-beam IMRT{sub cut} plans. Large reductions in rectum dose delivery were also observed when increasing the number of beam directions in the plans. For bilateral implants, the rectum V{sub 60Gy} was 37.3%{+-} 12.1% for coplanar 7-beam plans and reduced on average by 13.5% (maximum 30.1%, p= 0.012) for 15 directions.Conclusions: iCycle was able to automatically generate high quality plans for prostate cancer patients with prostheses. Excluding only beamlets that passed through the prostheses (IMRT{sub cut} strategy) significantly improved OAR sparing. Noncoplanar beam arrangements and, to a larger extent, increasing the number of treatment beams further improved plan quality.

61 RADIATION PROTECTION AND DOSIMETRY↗

A stochastic model for tumor geometry evolution during radiation therapy in cervical cancer

Purpose: To develop mathematical models to predict the evolution of tumor geometry in cervical cancer undergoing radiation therapy. Methods: The authors develop two mathematical models to estimate tumor geometry change: a Markov model and an isomorphic shrinkage model. The Markov model describes tumor evolution by investigating the change in state (either tumor or nontumor) of voxels on the tumor surface. It assumes that the evolution follows a Markov process. Transition probabilities are obtained using maximum likelihood estimation and depend on the states of neighboring voxels. The isomorphic shrinkage model describes tumor shrinkage or growth in terms of layers of voxels on the tumor surface, instead of modeling individual voxels. The two proposed models were applied to data from 29 cervical cancer patients treated at Princess Margaret Cancer Centre and then compared to a constant volume approach. Model performance was measured using sensitivity and specificity. Results: The Markov model outperformed both the isomorphic shrinkage and constant volume models in terms of the trade-off between sensitivity (target coverage) and specificity (normal tissue sparing). Generally, the Markov model achieved a few percentage points in improvement in either sensitivity or specificity compared to the other models. The isomorphic shrinkage model was comparable to the Markov approach under certain parameter settings. Convex tumor shapes were easier to predict. Conclusions: By modeling tumor geometry change at the voxel level using a probabilistic model, improvements in target coverage and normal tissue sparing are possible. Our Markov model is flexible and has tunable parameters to adjust model performance to meet a range of criteria. Such a model may support the development of an adaptive paradigm for radiation therapy of cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-19A-06: The Effect of Beam Parameters On Very High-Energy Electron Radiotherapy: A Planning Study

Purpose: We evaluated the effect of very high-energy electron (VHEE) beam parameters on the planning of a lung cancer case by means of Monte Carlo simulations. Methods: We simulated VHEE radiotherapy plans using the EGSnrc/BEAMnrc-DOSXYZnrc code. We selected a lung cancer case that was treated with 6MV photon VMAT to be planned with VHEE. We studied the effect of beam energy (80 MeV, 100 MeV, and 120 MeV), number of equidistant beams (16 or 32), and beamlets sizes (3 mm, 5 mm or 7 mm) on PTV coverage, sparing of organs at risk (OARs) and dose conformity. Inverse-planning optimization was performed in a research version of RayStation (RaySearch Laboratories AB) using identical objective functions and constraints for all VHEE plans. Results: Similar PTV coverage and dose conformity was achieved by all the VHEE plans. The 100 MeV and 120 MeV VHEE plans were equivalent amongst them and were superior to the 80 MeV plan in terms of OARs sparing. The effect of using 16 or 32 equidistant beams was a mean difference in average dose of 2.4% (0%–7.7%) between the two plans. The use of 3 mm beamlet size systematically reduced the dose to all the OARs. Based on these results we selected the 100MeV-16beams-3mm-beamlet-size plan to compare it against VMAT. The selected VHEE plan was more conformal than VMAT and improved OAR sparing (heart and trachea received 125% and 177% lower dose, respectively) especially in the low-dose region. Conclusion: We determined the VHEE beam parameters that maximized the OAR dose sparing and dose conformity of the actually delivered VMAT plan of a lung cancer case. The selected parameters could be used for the planning of other treatment sites with similar size, shape, and location. For larger targets, a larger beamlet size might be used without significantly increasing the dose. B Palma: None. M Bazalova: None. B Hardemark: Employee, RaySearch Americas. E Hynning: Employee, RaySearch Americas. B Qu: None. B Loo Jr.: Research support, RaySearch, Varian. P Maxim: Research support, RaySearch, Varian.

60 APPLIED LIFE SCIENCES↗

WE-A-BRD-01: Innovation in Radiation Therapy Planning I: Knowledge Guided Treatment Planning

Intensity modulated radiation therapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT) offer the capability of normal tissues and organs sparing. However, the exact amount of sparing is often unknown until the plan is complete. This lack of prior guidance has led to the iterative, trial and-error approach in current planning practice. Even with this effort the search for patient-specific optimal organ sparing is still strongly influenced by planner's experience. While experience generally helps in maximizing the dosimetric advantages of IMRT/VMAT, there have been several reports showing unnecessarily high degree of plan quality variability at individual institutions and amongst different institutions, even with a large amount of experience and the best available tools. Further, when physician and physicist evaluate a plan, the dosimetric quality of the plan is often compared with a standard protocol that ignores individual patient anatomy and tumor characteristic variations. In recent years, developments of knowledge models for clinical IMRT/VMAT planning guidance have shown promising clinical potentials. These knowledge models extract past expert clinical experience into mathematical models that predict dose sparing references at patient-specific level. For physicians and planners, these references provide objective values that reflect best achievable dosimetric constraints. For quality assurance, applying patient-specific dosimetry requirements will enable more quantitative and objective assessment of protocol compliance for complex IMRT planning. Learning Objectives: Modeling and representation of knowledge for knowledge-guided treatment planning. Demonstrations of knowledge-guided treatment planning with a few clinical caanatomical sites. Validation and evaluation of knowledge models for cost and quality effective standardization of plan optimization.

60 APPLIED LIFE SCIENCES↗

TH-A-9A-02: BEST IN PHYSICS (THERAPY) - 4D IMRT Planning Using Highly- Parallelizable Particle Swarm Optimization

Purpose: We present a particle swarm optimization (PSO)-based 4D IMRT planning technique designed for dynamic MLC tracking delivery to lung tumors. The key idea is to utilize the temporal dimension as an additional degree of freedom rather than a constraint in order to achieve improved sparing of organs at risk (OARs). Methods: The target and normal structures were manually contoured on each of the ten phases of a 4DCT scan acquired from a lung SBRT patient who exhibited 1.5cm tumor motion despite the use of abdominal compression. Corresponding ten IMRT plans were generated using the Eclipse treatment planning system. These plans served as initial guess solutions for the PSO algorithm. Fluence weights were optimized over the entire solution space i.e., 10 phases × 12 beams × 166 control points. The size of the solution space motivated our choice of PSO, which is a highly parallelizable stochastic global optimization technique that is well-suited for such large problems. A summed fluence map was created using an in-house B-spline deformable image registration. Each plan was compared with a corresponding, internal target volume (ITV)-based IMRT plan. Results: The PSO 4D IMRT plan yielded comparable PTV coverage and significantly higher dose—sparing for parallel and serial OARs compared to the ITV-based plan. The dose-sparing achieved via PSO-4DIMRT was: lung Dmean = 28%; lung V20 = 90%; spinal cord Dmax = 23%; esophagus Dmax = 31%; heart Dmax = 51%; heart Dmean = 64%. Conclusion: Truly 4D IMRT that uses the temporal dimension as an additional degree of freedom can achieve significant dose sparing of serial and parallel OARs. Given the large solution space, PSO represents an attractive, parallelizable tool to achieve globally optimal solutions for such problems. This work was supported through funding from the National Institutes of Health and Varian Medical Systems. Amit Sawant has research funding from Varian Medical Systems, VisionRT Ltd. and Elekta.

60 APPLIED LIFE SCIENCES↗