Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spaceflight Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Use of Mechanical Heat Switch to Speed up TVAC Transitions on Flight Hardware Below 200K

Spaceflight hardware that operates at temperatures well below room temperature usually require being well isolated from their warmer environment in order to manage thermal parasitics adequately. This is especially true for spaceflight systems that rely on passive cooling such as a radiator. During ground testing, this design configuration can be problematic for TVAC cycling between operational temperature extremes, since the hardware temperatures may move extremely slowly and lengthen the duration of an already expensive and heavily staffed system-level TVAC campaign. One of the challenges of using an external means of speeding up temperature transitions is that a TVAC campaign usually also requires the simulation of flight-like environments to validate the design, and introducing a test feature to speed up transitions can disrupt the system such that flight-like environments are not achievable. Such an approach was used for the L’Ralph instrument level TVAC test. L’Ralph is a passively cooled instrument on the Lucy mission with planned flyby’s of the Trojan asteroids around 5.5 AU. The optics and visible detector are cooled below 190K, and the IR detector is cooled below 110K. During instrument TVAC qualification testing, a mechanical motor-controlled heat switch uses clamping pressure via a vise-grip mechanism to achieve faster temperature transitions by increasing the conduction to a cold sink. The heat switch system then disengages and employs zero-Q controls to achieve flight-like thermal environments for thermal balance plateaus. Results from stand-alone testing of the heat switch are discussed, including correlated on/off ratios and the expected conductance across its operational temperature range. Test data from an instrument level TVAC that successfully utilized the heat switch are also shown.

Daniel G Bae↗

Comparison of Orion Flywheel to Commercially Available Flywheel Device

INTRODUCTION: The chosen exercise device for the Orion Multi-purpose Crew Vehicle (MPCV) for Artemis missions is the Orion Flywheel (OFW), which was selected in 2017 from a pool of exercise devices. The Orion Flywheel is to be installed in the MPCV for its first use during the Artemis II mission and will be utilized for subsequent Artemis missions. The OFW provides the capability to perform both resistive and aerobic exercises while taking up a small volume and not requiring power. Aerobic exercise consists of rowing while resistive exercise includes the deadlift, harness squat, and deadlift high pull among others. The efficacy of the OFW as an exercise countermeasure to spaceflight deconditioning has not yet been fully evaluated. A future HRP-funded study using head-down tilt bed rest is planned to evaluate the efficacy of the OFW to mitigate aerobic and muscular deconditioning. The OFW, made by KBR, is a specialized device that poses high costs for purchase and maintenance. The aim of the study is to determine if a commercially available alternative could be used as a backup for the OFW during the bed rest study or as an alternative in other studies. This study seeks to compare the loading profile and mechanics of a commercial flywheel device (kBox Pro) with the three resistance settings of the OFW using a controlled, instrumented setup to validate its acceptability as a backup. METHODS: An experimental setup was designed to simulate human use of the OFW. Flywheel devices can have varied actuated inertial mass and strap length. The inertial mass refers to the flywheel itself or the object that spins as the result of the movement of the strap. The OFW has three gears actuated with a lever, with the low gear used for aerobic rowing and the medium and high gears used for resistance exercises. These gears correspond to increasing flywheel inertia, which corresponds to a certain number and sizes of inertial plates on a commercial flywheel. The kBox Pro has varied sizes of inertial discs that are installed to the external shaft of the device and can be configured to roughly match the inertia seen in the OFW per gear setting. The strap length can be adjusted to allow for different ranges of motion. The experimental setup allows for the simulation of rowing, harness squats, and deadlift high pulls with corresponding exercise strap lengths. All three OFW gears are to be tested, as well as multiple combinations of kBox discs. The setup was created using a system of pulleys and cables to minimize friction loss. The system is actuated through the dropping of a connected mass which, through the pulley system, pulls the strap of the exercise device upwards as if a human was exercising. A string potentiometer and tensile force transducer are used to measure strap displacement and strap force, respectively. The masses dropped are exercise chains that simulate the decrease in force observed throughout a typical exercise. As the chains are lowered to the ground, they begin to spool and therefore are no longer subjecting the exercise device’s strap to their load. This setup was designed to provide realistic loads and protect the OFW from damage, an important precaution because it’s the only available unit for research and ground operations. Data is to be collected across simulated exercises and with different strap lengths, with the same conditions collected on both the OFW and the kBox Pro. RESULTS: Data collection is ongoing for the kBox and the Orion Flywheel. CONCLUSIONS: Study results will inform if the OFW and a kBox Pro device can be deemed mechanically similar. Depending on the results, additional data collection may be required to assess the user experience between the devices. A key result of this study is a mechanical characterization of the OFW device, demonstrating the load and force profile using a repeatable test method. This data will guide next steps on potential kBox Pro modifications needed to produce a comparable exercise experience to the OFW.

Exercise↗

Plastid position in Arabidopsis columella cells is similar in microgravity and on a random-positioning machine

In order to study gravity effects on plant structure and function, it may become necessary to remove the g-stimulus. On Earth, various instruments such as clinostats have been used by biologists in an attempt to neutralize the effects of gravity. In this study, the position of amyloplasts was assayed in columella cells in the roots of Arabidopsis thaliana (L.) Heynh. seedlings grown in the following conditions: on Earth, on a two-dimensional clinostat at 1 rpm, on a three-dimensional clinostat (also called a random-positioning machine, or an RPM), and in space (true microgravity). In addition, the effects of these gravity treatments on columella cell area and plastid area also were measured. In terms of the parameters measured, only amyloplast position was affected by the gravity treatments. Plastid position was not significantly different between spaceflight and RPM conditions but was significantly different between spaceflight and the classical two-dimensional clinostat treatments. Flanking columella cells showed a greater susceptibility to changes in gravity compared to the central columella cells. In addition, columella cells of seedlings that were grown on the RPM did not exhibit deleterious effects in terms of their ultrastructure as has been reported previously for seedlings grown on a two-dimensional clinostat. This study supports the hypothesis that the RPM provides a useful simulation of weightlessness.

Non-NASA Center↗

Report on phase 2 of 1990 OSSA data census

The 1990 NASA Office of Space Science and Applications (OSSA) data census contributed significantly to a database intended to identify and briefly describe all archived data and potentially archive-desirable data from active and inactive NASA/OSSA spaceflight investigations. This database is being created at the National Space Science Data Center (NSSDC) and will be more comprehensive than the databases describing data held at individual sites such as NSSDC. Active investigations are defined as those flying on currently operational spacecraft or those that flew on recently operational spacecraft for which project-coordinated data archiving is continuing. Inactive investigations are those that flew on spacecraft that are no longer operational, and for which systematic archiving has ended. The principal purpose of this report is to describe phase two of the 1990 census. The previously reported phase one of this census, as well as a relevant 1981 census, are briefly discussed. The phase two survey instrument is described, those surveyed and respondents/reponses are identified, and data sets from inactive OSSA investigations discovered during the 1990 census (phase two) are briefly discussed individually.

King, Joseph H.↗

Bion-11 Spaceflight Mission

The Sensors 2000! Program, in support of the Space Life Sciences Payloads Office at NASA Ames Research Center developed a suite of bioinstrumentation hardware for use on the Joint US/Russian Bion I I Biosatellite Mission (December 24, 1996 - January 7, 1997). This spaceflight included 20 separate experiments that were organized into a complimentary and interrelated whole, and performed by teams of US, Russian, and French investigators. Over 40 separate parameters were recorded in-flight on both analog and digital recording media for later analysis. These parameters included; Electromyogram (7 ch), Electrogastrogram, Electrooculogram (2 ch), ECG/EKG, Electroencephlogram (2 ch), single fiber firing of Neurovestibular afferent nerves (7 ch), Tendon Force, Head Motion Velocity (pitch & yaw), P02 (in vivo & ambient), temperature (deep body, skin, & ambient), and multiple animal and spacecraft performance parameters for a total of 45 channels of recorded data. Building on the close cooperation of previous missions, US and Russian engineers jointly developed, integrated, and tested the physiologic instrumentation and data recording system. For the first time US developed hardware replaced elements of the Russian systems resulting in a US/Russian hybrid instrumentation and data system that functioned flawlessly during the 14 day mission.

Skidmore, M.↗

Bluetooth(Registered Trademark) Heart Rate Monitors for Spaceflight

Heart rate monitoring is required during exercise for crewmembers aboard the International Space Station (ISS) and will be for future exploration missions. The cardiovascular system must be sufficiently stressed throughout a mission to maintain the ability to perform nominal and contingency/emergency tasks. High quality heart rate data is required to accurately determine the intensity of exercise performed by the crewmembers and show maintenance of VO2max. The quality of the data collected on ISS is subject to multiple limitations and is insufficient to meet current requirements. PURPOSE: To evaluate the performance of commercially available Bluetooth® heart rate monitors (BT_HRM) and their ability to provide high quality heart rate data to monitor crew health on board ISS and during future exploration missions. METHODS: Nineteen subjects completed 30 data collection sessions of various intensities on the treadmill and/or cycle. Subjects wore several BT_HRM technologies for each testing session. One electrode-based chest strap (CS) was worn, while one or more optical sensors (OS) was worn. Subjects were instrumented with a 12-lead ECG to compare the heart rate data from the Bluetooth sensors. Each BT_RHM data set was time matched to the ECG data and a +/-5bpm threshold was applied to the difference between the two data sets. Percent error was calculated based on the number of data points outside the threshold and the total number of data points. REULTS: The electrode-based chest straps performed better than the optical sensors. The best performing CS was CS1 (1.6%error), followed by CS4 (3.3%error), CS3 (6.4%error), and CS2 (9.2%error). The OS resulted in 10.4% error for OS1 and 14.9% error for OS2. CONCLUSIONS: The highest quality data came from CS1, unfortunately it has been discontinued by the manufacturer. The optical sensors have not been ruled out for use, but more investigation is needed to determine how to get the best quality data. CS2 will be used in an ISS Bluetooth validation study, because it simultaneously transmits Magnetic Pulse which is integrated with existing exercise hardware on ISS. The simultaneous data streams allow for beat to beat comparison between the current ISS standard and CS2.Upon Bluetooth(Registered Trademark) validation aboard ISS, down select of a new BT_HRM for operational use will be made.

Buxton, Roxanne E.↗

Bluetooth Heart Rate Monitors For Spaceflight

Heart rate monitoring is required for crewmembers during exercise aboard the International Space Station (ISS) and will be for future exploration missions. The cardiovascular system must be sufficiently stressed throughout a mission to maintain the ability to perform nominal and contingency/emergency tasks. High quality heart rate data are required to accurately determine the intensity of exercise performed by the crewmembers and show maintenance of VO2max. The quality of the data collected on ISS is subject to multiple limitations and is insufficient to meet current requirements. PURPOSE: To evaluate the performance of commercially available Bluetooth heart rate monitors (BT_HRM) and their ability to provide high quality heart rate data to monitor crew health aboard the ISS and during future exploration missions. METHODS: Nineteen subjects completed 30 data collection sessions of various intensities on the treadmill and/or cycle. Subjects wore several BT_HRM technologies for each testing session. One electrode-based chest strap (CS) was worn, while one or more optical sensors (OS) were worn. Subjects were instrumented with a 12-lead ECG to compare the heart rate data from the Bluetooth sensors. Each BT_HRM data set was time matched to the ECG data and a +/-5bpm threshold was applied to the difference between the 2 data sets. Percent error was calculated based on the number of data points outside the threshold and the total number of data points. RESULTS: The electrode-based chest straps performed better than the optical sensors. The best performing CS was CS1 (1.6% error), followed by CS4 (3.3% error), CS3 (6.4% error), and CS2 (9.2% error). The OS resulted in 10.4% error for OS1 and 14.9% error for OS2. CONCLUSIONS: The highest quality data came from CS1, but unfortunately it has been discontinued by the manufacturer. The optical sensors have not been ruled out for use, but more investigation is needed to determine how to obtain the best quality data. CS2 will be used in an ISS Bluetooth validation study, because it simultaneously transmits magnetic pulse that is integrated with existing exercise hardware on ISS. The simultaneous data streams allow for beat-to-beat comparison between the current ISS standard and CS2. Upon Bluetooth validation aboard ISS, the research team will down select a new BT_HRM for operational use.

Buxton, R. E.↗

Kinetic Requirements for the Measurement of Mesospheric Water Vapor at 6.8 (microns) under Non-LTE Conditions

We present accuracy requirements for specific kinetic parameters used to calculate the populations and vibrational temperatures of the H2O(010) and H2O(020) states in the terrestrial mesosphere. The requirements are based on rigorous simulations of the retrieval of mesospheric water vapor profiles from measurements of water vapor infrared emission made by limb scanning instruments on orbiting satellites. Major improvements in the rate constants that describe vibration-to- vibration exchange between the H2O(010) and 02(1) states are required in addition to improved specification of the rate of quenching Of O2(1) by atomic oxygen (0). It is also necessary to more accurately determine the yield of vibrationally excited O2(l) resulting from ozone photolysis. A contemporary measurement of the rate of quenching of H2O(010) by N2 and O2 is also desirable. These rates are either highly uncertain or have never before been measured at atmospheric temperatures. The suggested improvements are necessary for the interpretation of water vapor emission measurements at 6.8 microns to be made from a new spaceflight experiment in less than 2 years. The approach to retrieving water vapor under non-LTE conditions is also presented.

Zhou, Daniel K.↗

SMD Technology Highlights

Six technology highlights from the Science Mission Directorate (SMD) Heliophysics, Astrophysics, Earth, and Biological and Physical Sciences divisions. Technologies featured include 1. the 1653 m2 Solar Cruiser Solar Sail Propulsion system to enable missions to reach novel and otherwise difficult or impossible destinations for observing the Sun. 2. Technology sponsored by NASA and developed by MIT Space Nanotechnology Lab is developing high-performance space instrumentation for more powerful future X-ray telescopes that will study the dynamics of the high-energy universe. 3. Active thermal control technology that will help enable large ultra-stable telescopes needed to detect and characterize Earth-like planets around other stars. 4. SMD sponsored high-performance infrared sensors with reduced requirements for cooling onboard satellites and these sensors could potentially be flown on small satellite platforms like CubeSats. 5. A new technology that will utilize electron beams/ultraviolet light to remove dust that could help protect future space assets and astronauts from dangerous effects that arise from Moon/Mars dust exposure. 6. Studies using model organisms on ISS to understand the impact of the spaceflight environment on organisms in preparation for long-duration missions.

solar sail↗

Legacy of Environmental Research During the Space Shuttle Program

The Space Shuttle Program provided many opportunities to study the role of spaceflight on human life for over the last 30 years and represents the longest and largest U.S. human spaceflight program. Risks to crewmembers were included in the research areas of nutrition, microbiology, toxicology, radiation, and sleep quality. To better understand the Shuttle environment, Crew Health Care System was developed. As part of this system, the Environmental Health Subsystem was developed to monitor the atmosphere for gaseous contaminants and microbial contamination levels and to monitor water quality and radiation. This program expended a great deal of effort in studying and mitigating risks related to contaminations due to food, water, air, surfaces, crewmembers, and payloads including those with animals. As the Shuttle had limited stowage space and food selection, the development of nutritional requirements for crewmembers was imperative. As the Shuttle was a reusable vehicle, microbial contamination was of great concern. The development of monitoring instruments that could withstand the space environment took several years and many variations to come up with a suitable instrument. Research with space radiation provided an improved understanding of the various sources of ionizing radiation and the development of monitoring instrumentation for space weather and the human exposure within the orbiter's cabin. Space toxicology matured to include the management of offgassing products that could pollute the crewmembers air quality. The Shuttle Program implemented a 5-level toxicity rating system and developed new monitoring instrumentation to detect toxic compounds. The environment of space caused circadian desynchrony, sleep deficiency, and fatigue leading to much research and major emphasis on countermeasures. Outcomes of the research in these areas were countermeasures, operational protocols, and hardware. Learning Objectives: This symposium will provide an overview of the major environmental lessons learned and the development of countermeasures, monitoring hardware, and procedures.

Lane, Helen W.↗

Virtual Reality as a Medium for Sensorimotor Adaptation Training and Spaceflight Countermeasures

With the upcoming shift to extra‐long duration missions (1 year) aboard the ISS, sensorimotor adaptations during transitory periods in‐and‐out of microgravity are more important to understand and prepare for. Advances in virtual reality technology enables everyday adoption of these tools for entertainment and use in training. Experiencing virtual environments (VE) allows for the manipulation of visual flow to elicit automatic motor behavior and produce sensorimotor adaptation (SA). Recently, the ability to train individuals using repeatable and varied exposures to SA challenges has shown success by improving performance during exposure to a novel environment (Batson 2011). This capacity to 'learn to learn' is referred to as sensorimotor adaptive generalizability and, through the use of treadmill training, represents an untapped potential for individualized countermeasures. The goal of this study is to determine the feasibility of present head mounted displays (HMDs) to produce compelling visual flow information and the expected adaptations for use in future SA treadmill‐based countermeasures. Participants experience infinite hallways providing congruent (baseline) or incongruent visual information (half or double speed) via HMD while walking on an instrumented treadmill at 1.1m/s. As gait performance approaches baseline levels, an adaptation time constant is derived to establish individual time‐to‐adapt (TTA). It is hypothesized that decreasing the TTA through SA treadmill training will facilitate sensorimotor adaptation during gravitational transitions. In this way, HMD technology represents a novel platform for SA training using off‐the‐shelf consumer products for greater training flexibility in astronaut and terrestrial applications alike.

Madansingh, S.↗

Lunar Atmosphere and Dust Environment Explorer Integration and Test

Integration and test (I&T) of the Lunar Atmosphere and Dust Environment Explorer (LADEE) is presented. A collaborative NASA project between Goddard Space Flight Center and Ames Research Center, LADEE's mission is to explore the low lunar orbit environment and exosphere for constituents. Its instruments include two spectrometers, a dust detector, and a laser communication technology demonstration. Although a relatively low-cost spacecraft, LADEE has I&T requirements typical of most planetary probes, such as prelaunch contamination control, sterilization, and instrument calibration. To lead to a successful mission, I&T at the spacecraft, instrument, and observatory level must include step-by-step and end-to-end functional, environmental, and performance testing. Due to its compressed development schedule, LADEE I&T planning requires adjusting test flows and sequences to account for long-lead critical-path items and limited spares. A protoflight test-level strategy is also baselined. However, the program benefits from having two independent but collaborative teams of engineers, managers, and technicians that have a wealth of flight project experience. This paper summarizes the LADEE I&T planning, flow, facilities, and probe-unique processes. Coordination of requirements and approaches to I&T when multiple organizations are involved is discussed. Also presented are cost-effective approaches to I&T that are transferable to most any spaceflight project I&T program.

Wright, Michael R.↗

IceCube: Demonstration of an 883 GHz Radiometer for Ice Cloud Remote Sensing

IceCube was a technology demonstration of an 883 GHz heterodyne radiometer on a 3U CubeSat for ice cloud characterization. The project was a collaboration between Goddard Space Flight Center, Virginia Diodes Inc., and Wallops Flight Facility. IceCube was launched to the International Space Station (ISS) in April 2017, and was deployed to the orbit in May 2017. The radiometer measured ice cloud emissions from an ISS orbit for over 15 months. IceCube generated the first 883 GHz cloud map over a large operation temperature range of (5 ºC—37 ºC). Cloud ice plays a major role in the cloud precipitation process and Earth’s energy budget. Ice clouds are used in global circulation models as tuning parameters to achieve model agreement with observation at the top of the atmosphere in the radiation budget and at the bottom for precipitation, however, due to a lack of accurate ice cloud measurements large uncertainties exist in these models. Submillimeter wave remote sensing is capable of addressing this issue by measuring cloud ice mass and microphysical properties in the middle-to-upper troposphere. This fills the sensitivity gap not covered by the visible/infrared and microwave sensors [1]. The goal of IceCube was to increase the TRL of a heterodyne 883 GHz radiometer (using commercial parts) from 5 to 7 by validating the performance in a relevant spaceflight environment. The design of the radiometer was driven by frequency of operation, bandwidth, calibration, available power, and thermal environment requirements. The design included a 15 mm aperture off-axis parabolic reflector with a Potter feed horn, an 883 GHz 2nd-harmonic mixer that is fed by a local oscillator chain with a 24.3 GHz dielectric resonator (MLA), followed by a 6 GHz bandwidth centered at 9 GHz intermediate frequency assembly (IFA), receiver interface card, and power distribution unit. The IFA included an internal noise diode calibration to separate the MLA performance from the rest of the system. For this the radiometer had four operational states: antenna, antenna + noise, reference, and reference + noise; each state’s duration was 10 ms. The total power dissipation of the instrument was 5.6 W. The spacecraft had spinning capabilities to provide a cold sky view for calibration. We present the instrument design, ground test results, challenges, and highlight some of the flight measurements.

N Ehsan↗

Radiation damage and annealing of three coaxial n-type germanium detectors: Preparation for spaceflight missions to asteroid 16 Psyche and Mars’ moon Phobos

Three n-type high-purity germanium (HPGe) detectors were irradiated with protons at solar and galactic cosmic ray energies, with fluences corresponding to 3 years of exposure to the interplanetary radiation environment. Following 1 GeV proton irradiations (8x10 8 protons cm –2 ), annealing of the detectors at 105° and 115 °C resulted in full energy resolution recovery after 240 and 140 h of annealing, respectively. A second irradiation, consisting of 7.25x10 9 protons cm –2 with a solar-proton-like energy spectrum, resulted in full recovery within <316 h of annealing at 105 °C. Prior spaceflight experience raised concerns about annealing-induced leakage currents. During this study, one of the three detectors was annealed for a cumulative time of 57 days, and there was no evidence for increased leakage currents. However, gamma-ray photopeak detection efficiency was found to be strongly anti-correlated with cumulative anneal time for all three detectors. The energy- and time-dependence of the efficiency loss is consistent with the loss of active volume at the inner borehole, which we attribute to thermal diffusion of the lithium contact during annealing. The data collected during this study validate aspects of the design of two in-development planetary gamma-ray spectrometers; one to the asteroid (16) Psyche and one to Mars’ moon Phobos. The annealing strategy and operations concepts for these two instruments are informed by the results of this study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of a Gas Chromatograph-Differential Mobility Spectrometer for Potential Water Monitoring on the International Space Station

Environmental monitoring for manned spaceflight has long depended on archival sampling, which was sufficient for short missions. However, the longer mission durations aboard the International Space Station (ISS) have shown that enhanced, real-time monitoring capabilities are necessary in order to protect both the crewmembers and the spacecraft systems. Over the past several years, a number of real-time environmental monitors have been deployed on the ISS. Currently, volatile organic compounds (VOCs) in the station air are monitored by the Air Quality Monitor (AQM), a small, lightweight gas chromatograph-differential mobility spectrometer. For water monitoring, real-time monitors are used for total organic carbon (TOC) and biocide analysis. No information on the actual makeup of the TOC is provided presently, however. An improvement to the current state of environmental monitoring could be realized by modifying a single instrument to analyze both air and water. As the AQM currently provides quantitative, compound-specific information for VOCs in air samples, this instrument provides a logical starting point to evaluate the feasibility of this approach. The major hurdle for this effort lies in the liberation of the target analytes from the water matrix. In this presentation, we will discuss our recent studies, in which an electro-thermal vaporization unit has been interfaced with the AQM to analyze target VOCs at the concentrations at which they are routinely detected in archival water samples from the ISS. We will compare the results of these studies with those obtained from the instrumentation routinely used to analyze archival water samples.

Wallace, William T.↗

Operational Aspects of Space Radiation Analysis

Minimizing astronaut's short and long-term medical risks arising from exposure to ionizing radiation during space missions is a major concern for NASA's manned spaceflight program, particularly exploration missions. For ethical and legal reasons, NASA follows the "as low as reasonably achievable" (ALARA) principal in managing astronaut's radiation exposures. One implementation of ALARA is the response to space weather events. Of particular concern are energetic solar particle events, and in low Earth orbit (LEO), electron belt enhancements. To properly respond to these events, NASA's Space Radiation Analysis Group (SRAG), in partnership with the NOAA Space Environment Center (SEC), provides continuous flight support during U.S. manned missions. In this partnership, SEC compiles space weather data from numerous ground and space based assets and makes it available in near real-time to SRAG (along with alerts and forecasts), who in turn uses these data as input to models to calculate estimates of the resulting exposure to astronauts. These calculations and vehicle instrument data form the basis for real-time recommendations to flight management. It is also important to implement ALARA during the design phase. In order to appropriately weigh the risks associated with various shielding and vehicle configuration concepts, the expected environment must be adequately characterized for nominal and worst case scenarios for that portion of the solar cycle and point in space. Even with the best shielding concepts and materials in place (unlikely), there will be numerous occasions where the crew is at greater risk due to being in a lower shielded environment (short term transit or lower shielded vehicles, EVAs), so that accurate space weather forecasts and nowcasts, of particles at the relevant energies, will be crucial to protecting crew health and safety.

Weyland, M. D.↗

Virtual Reality as a Medium for Sensorimotor Adaptation Training and Spaceflight Countermeasures

Astronauts experience a profound sensorimotor adaptation during transition to and from the microgravity environment of space. With the upcoming shift to extra‐long duration missions (upwards of 1 year) aboard the International Space Station, the immediate risks to astronauts during these transitory periods become more important than ever to understand and prepare for. Recent advances in virtual reality technology enable everyday adoption of these tools for entertainment and use in training. Embedding an individual in a virtual environment (VE) allows the ability to change the perception of visual flow, elicit automatic motor behavior and produce sensorimotor adaptation, not unlike those required during long duration microgravity exposure. The overall goal of this study is to determine the feasibility of present head mounted display technology (HMD) to produce reliable visual flow information and the expected adaptation associated with virtual environment manipulation to be used in future sensorimotor adaptability countermeasures. To further understand the influence of visual flow on gait adaptation during treadmill walking, a series of discordant visual flow manipulations in a virtual environment are proposed. Six healthy participants (3 male and 3 female) will observe visual flow information via HMD (Oculus Rift DK2) while walking on an instrumented treadmill at their preferred walking speed. Participants will be immersed in a series of VE's resembling infinite hallways with different visual characteristics: an office hallway, a hallway with pillars and the hallway of a fictional spacecraft. Participants will perform three trials of 10 min. each, which include walking on the treadmill while receiving congruent or incongruent visual information via the HMD. In the first trial, participants will experience congruent visual information (baseline) where the hallway is perceived to move at the same rate as their walking speed. The final two trials will be randomized among participants where the hallway is perceived to move at either half (0.5x) or twice (2.0x) their preferred walking speed. Participants will remain on the treadmill between trials and will not be warned of the upcoming change to visual flow to minimize preparatory adjustments. Stride length, step frequency and dual‐support time will be quantified during each trial. We hypothesize that participants will experience a rapid modification in gait performance during periods of adaptive change, expressed as a decrease in step length, an increase in step frequency and an increase in dual‐support time, followed by a period of adaptation where these movement parameters will return to near‐baseline levels. As stride length, step frequency and dual support times return to baseline values, an adaptation time constant will be derived to establish individual time‐to‐adapt (TTA). HMD technology represents a paradigm shift in sensorimotor adaptation training where gait adaptability can be stressed using off‐the‐shelf consumer products and minimal experimental equipment, allowing for greater training flexibility in astronaut and terrestrial applications alike.

Madansingh, S.↗

DEVELOPMENT OF AN INFLIGHT COUNTERMEASURE TO MITIGATE POSTFLIGHT GAIT DYSFUNCTION

Following spaceflight crewmembers experience gait and postural instabilities due to inflight adaptive alterations in sensorimotor function. These changes can pose a risk to crew safety if nominal or emergency vehicle egress is required immediately following long-duration spaceflight. At present, no operational countermeasure is available to mitigate postflight locomotor disturbances. Therefore, the goal of this study is to develop an inflight training regimen that facilitates the recovery of locomotor function after long-duration spaceflight. The countermeasure we are developing is based on the concept of variable practice. During this type of training the subject gains experience producing the appropriate adaptive motor behavior under a variety of sensory conditions and response constraints. This countermeasure is built around current ISS treadmill exercise activities. Crewmembers will conduct their nominal inflight treadmill exercise while being exposed to variations in visual flow patterns. These variations will challenge the postural and locomotor systems repeatedly, thereby promoting adaptive reorganization in locomotor behavior. As a result of this training a subject learns to solve a class of motor problems, rather than a specific motor solution to one problem, Le., the subject learns response generalizability or the ability to "learn to learn" under a variety of environmental constraints. We anticipate that this training will accelerate recovery of postural and locomotor function during readaptation to gravitational environments following spaceflight facilitating neural adaptation to unit (Earth) and partial (Mars) gravity after long-duration spaceflight. The study calls for one group of subjects to perform the inflight treadmill training regimen while a control group of subjects performs only the nominal exercise procedures. Locomotor function in both groups is assessed before and after spaceflight using two tests of gait function: The Integrated Treadmill Locomotion Test (ITLT) and the Functional Mobility Test (FMT). The ITLT characterizes alterations in the integrated function of multiple sensorimotor subsystems responsible for the control of locomotion. This test calls for subjects to walk on a motorized treadmill while we assess changes in dynamic postural stability, head-trunk coordination, short-latency head stabilization responses, dynamic visual acuity, lower limb coordination strategies and gait cycle timing. To make these assessments we measure the following parameters while subjects walk on the treadmill: 1) full body 3-dimensional kinematics using a motion capture system (Motion Analysis Corp., Santa Rosa, CA); 2) the shock-wave transmitted from heel-strike to the head using triaxial accelerometers placed on the tibia and head (Entran, Fairfield, NJ); 3) vertical forces using an instrumented treadmill (Kistler Instrument Corp., Amherst, NY); 4) Dynamic visual acuity using Landolt Cs presented on a laptop computer located 4m from the eyes and 5) Gait cycle timing using foot-switches (Motion Lab Systems, Inc., Baton Rouge, LA) attached to the plantar surface of each shoe at the heel and toe. The FMT evaluates a subject's ability to perform challenging locomotor maneuvers similar to those encountered during an egress from a space vehicle. Subjects step over and duck under obstacles along with negotiating a series of pylons set up on a base of 10 cm thick medium density foam. The dependent measures for the FMT are time to complete the course and the number of obstacles touched. To date, we have collected pre and postflight locomotion data from Expeditions 5-9 who will serve as part of the control group for this study. Preliminary results comparing the recovery rates in gait control sub-systems obtained from the ITLT and FMT performance showed two recovery patterns: 1) a concordant recovery trend between gait control parameters and FMT performance indicating a restitution pattern of recovery and 2) gait controecovery that lagged recovery in FMT performance suggesting that improvement in locomotor function was attained through a pattern of substitution. These data suggest that recovery of postflight locomotor function may occur through adaptive mechanisms that lead to either restitution or substitution of function. Understanding the modes of postflight readaptation has implications for countermeasure development and testing and in astronaut postflight rehabilitation.

Bloomberg, J. J.↗