Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Solar Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Performance Evaluation and Optimal Design Analysis of Continuous-Operation Solar-Driven Cooling Absorption Systems With Thermal Energy Storage

A solar absorption cooling system consisting of a flat plate collector, thermal energy storage tank, and absorption chiller is analyzed in this work. A dimensionless model is developed from the energy balance on each component and the chiller's characteristic performance curves. The model is used to determine the interaction and influence of different parameters such as tank size, solar collector area, chiller size, cooling load, cooling temperature, heat loss, and mass flow rates on the performance. From the analysis, smaller solar collector areas are required for lower cooling loads and smaller tank volumes. A specific cooling load of 1 x 10^-5 will require a specific solar collector area between two and six times larger, depending on the initial tank temperature, than the area required for a baseline system that considers typical commercial design and operation parameters. A similar behavior was observed for the specific tank volume. For the baseline system, the minimum specific area of the collector of 9.57 is achieved for an initial tank temperature of 1.19. For a cooling load of 1 x 10^-5, the optimum initial tank temperature will be 1.11 that results in a minimum specific solar collector area of 25.26. A specific tank volume of 4 x 10^-4 will also have an optimum initial tank temperature of 1.11 that minimizes the specific solar collector area to a value of 28.18. The approach and analysis in this work can be used to determine design parameters for solar absorption cooling systems based on a proper relation among system's dimensions to achieve optimum operation.

cooling load↗

THE EFFECT OF ELECTRON THERMAL PRESSURE ON THE OBSERVED MAGNETIC HELICITY IN THE SOLAR WIND

Statistical analysis of magnetic helicity spectra in the solar wind at 1 au is carried out. A large database of the solar wind intervals assembled from Wind spacecraft magnetic and plasma data is used. The effect of the electron thermal pressure on the wavenumber position of the helicity signature, i.e., the peak of the spectrum, is studied. The position shows a statistically significant dependence on both the electron and proton pressures. However, the strongest dependence is seen when the two pressures are summed. These findings confirm that the generation of the magnetic helicity is associated with an increasing compressibility of the turbulent fluctuations at smaller kinetic scales. It is argued that instrumental artifacts do not contribute to the helicity signature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sharing the Sun: Community Solar Deployment and Subscriptions (As of January 2026)

The community solar market analysis presented here is based primarily on data collected through Sharing the Sun, an initiative of the National Community Solar Partnership+ (NCSP+). Sharing the Sun data collection and analysis are conducted by the National Laboratory of the Rockies (NLR) as part of its support for implementation of NCSP+. NLR first released a dataset of community solar projects in 2018 and updates it biannually. The January 2026 dataset, data collection methodology, and all the previous datasets are available from NLR's Data Catalog: https://data.nlr.gov/submissions/244. The dataset presents project-level information including location, capacity, operating utility, and year of interconnection. The dataset is created from multiple data sources such as utility data, public utility commissions, project developer websites, media releases, primary data collection by NLR, and data provided by developers under nondisclosure agreements. This presentation builds on a previous analysis of the community solar project dataset, Sharing the Sun: Community Solar Deployment and Subscriptions (as of June 2024). Dr. Gabriel Chan and his team at the University of Minnesota contribute to this effort. NCSP+ is led and funded by U.S. Department of Energy's Integrated Energy Systems Office (IESO).

14 SOLAR ENERGY↗

Thermodynamic Analysis of Isothermal Redox Cycling of Ceria for Solar Fuel Production

A thermodynamic analysis of continuous fuel production by redox cycling of ceria in a single solar reactor under isothermal conditions is presented. Ceria is partially reduced in a sweep gas flow of purified nitrogen and reoxidized with either steam or carbon dioxide to produce hydrogen or carbon monoxide, respectively. The sweep gas and oxidizer flows are preheated by the product gases. The influence of selected process parameters, including operating temperature, pressure, and the effectiveness of heat recovery, on the solar-to-fuel conversion efficiency is determined. For a solar concentration ratio of 3000, typical of state-of-the-art solar dish concentrators, and operating temperature of 1773 K, 95.5% of the available gas-phase heat must be recovered to reach conversion efficiencies of 10% and 18% for hydrogen and carbon monoxide production, respectively, assuming the flow rate of inert sweep gas is equivalent to that in a counter-current flow arrangement of gas and ceria. The efficiency depends strongly on the gas-phase heat recovery effectiveness and the sweep gas flow rate. Introducing a temperature swing of 150 K between reduction and oxidation steps strongly reduces the sweep gas flow rate and increases the efficiency from 10% to 31.6% for hydrogen production.

Bader, R↗

Web tools concerning performance analysis and planning support for solar energy plants starting from remotely sensed optical images

We present innovative web tools, developed also in the frame of the FP7 ENDORSE (ENergy DOwnstReam SErvices) project, for the performance analysis and the support in planning of solar energy plants (PV, CSP, CPV). These services are based on the combination between the detailed physical model of each part of the plants and the near real-time satellite remote sensing of incident solar irradiance. Starting from the solar Global Horizontal Irradiance (GHI) data provided by the Monitoring Atmospheric Composition and Climate (GMES-MACC) Core Service and based on the elaboration of Meteosat Second Generation (MSG) satellite optical imagery, the Global Tilted Irradiance (GTI) or the Beam Normal Irradiance (BNI) incident on plant's solar PV panels (or solar receivers for CSP or CPV) is calculated. Combining these parameters with the model of the solar power plant, using also air temperature values, we can assess in near-real-time the daily evolution of the alternate current (AC) power produced by the plant. We are therefore able to compare this satellite-based AC power yield with the actually measured one and, consequently, to readily detect any possible malfunctions and to evaluate the performances of the plant (so-called “Controller” service). Besides, the same method can be applied to satellite-based averaged environmental data (solar irradiance and air temperature) in order to provide a Return on Investment analysis in support to the planning of new solar energy plants (so-called “Planner” service). This method has been successfully applied to three test solar plants (in North, Centre and South Italy respectively) and it has been validated by comparing satellite-based and in-situ measured hourly AC power data for several months in 2013 and 2014. The results show a good accuracy: the overall Normalized Bias (NB) is − 0.41%, the overall Normalized Mean Absolute Error (NMAE) is 4.90%, the Normalized Root Mean Square Error (NRMSE) is 7.66% and the overall Correlation Coefficient (CC) is 0.9538. The maximum value of the Normalized Absolute Error (NAE) is about 30% and occurs for time periods with highly variable meteorological conditions. - Highlights: • We developed an online service (Controller) dedicated to solar energy plants real-time monitoring • We developed an online service (Planner) that supports the planning of new solar energy plants • The services are based on the elaboration of satellite optical imagery in near real-time • The validation with respect to in-situ measured hourly AC power data for three test solar plants shows good accuracy • The maximum value of the Normalized Absolute Error is about 30% and occurs for highly variable meteorological conditions.

14 SOLAR ENERGY↗

Interpretation of solar irradiance monitor measurements through analysis of 3D MHD simulations

Measurements from the Spectral Irradiance Monitor (SIM) on board the Solar Radiation and Climate Experiment mission indicate that solar spectral irradiance at visible and IR wavelengths varies in counter phase with the solar activity cycle. The sign of these variations is not reproduced by most of the irradiance reconstruction techniques based on variations of surface magnetism employed so far, and it is not yet clear whether SIM calibration procedures need to be improved or if instead new physical mechanisms must be invoked to explain such variations. We employ three-dimensional magnetohydrodynamic simulations of the solar photosphere to investigate the dependence of solar radiance in SIM visible and IR spectral ranges on variations of the filling factor of surface magnetic fields. We find that the contribution of magnetic features to solar radiance is strongly dependent on the location on the disk of the features, which are negative close to disk center and positive toward the limb. If features are homogeneously distributed over a region around the equator (activity belt), then their contribution to irradiance is positive with respect to the contribution of HD snapshots, but decreases with the increase of their magnetic flux for average magnetic flux larger than 50 G in at least two of the visible and IR spectral bands monitored by SIM. Under the assumption that the 50 G snapshots are representative of quiet-Sun regions, we thus find that the Spectral Irradiance can be in counter-phase with the solar magnetic activity cycle.

79 ASTRONOMY AND ASTROPHYSICS↗

Wisdom Way Solar Village: Design, Construction, and Analysis of a Low Energy Community

This report describes work conducted at the Wisdom Way Solar Village (WWSV), a community of 10 high performance duplexes (20 homes) in Greenfield, MA, constructed by Rural Development, Inc. (RDI). Building America's CARB team monitored temperatures and comfort in several homes during the winter of 2009-2010, and tracked utility bill information from 13 occupied homes. Because of efficient lights,appliances, and conscientious home occupants, the energy generated by the solar electric systems exceeded the electric energy used in most homes.

14 SOLAR ENERGY↗

Wisdom Way Solar Village: Design, Construction, and Analysis of a Low Energy Community

This report describes work conducted at the Wisdom Way Solar Village (WWSV), a community of 10 high performance duplexes (20 homes) in Greenfield, MA, constructed by Rural Development, Inc. (RDI). Building America's CARB team monitored temperatures and comfort in several homes during the winter of 2009-2010, and tracked utility bill information from 13 occupied homes. Because of efficient lights, appliances, and conscientious home occupants, the energy generated by the solar electric systems exceeded the electric energy used in most homes.

14 SOLAR ENERGY↗

Determining the Elemental and Isotopic Composition of the Pre-solar Nebula from Genesis Data Analysis: The Case of Oxygen

Here, we compare element and isotopic fractionations measured in bulk solar wind samples collected by NASA's Genesis mission with those predicted from models incorporating both the ponderomotive force in the chromosphere and conservation of the first adiabatic invariant in the low corona. Generally good agreement is found, suggesting that these factors are consistent with the process of solar wind fractionation. Based on bulk wind measurements, we also consider in more detail the isotopic and elemental abundances of O. We also find mild support for an O abundance in the range 8.75–8.83, with a value as low as 8.69 disfavored. A stronger conclusion must await solar wind regime-specific measurements from the Genesis samples.

79 ASTRONOMY AND ASTROPHYSICS↗

Techno-Economic Analysis of a Small Scale Solar Power Tower at Varied Locations

Location selection is an important factor for the effectiveness and cost of a solar electricity generation system. Latitude and weather impact efficiency and availability, and local labor rates have a further influence on cost. To explore the impact of these effects, we performed techno-economic analysis of a small-scale solar power tower concept in six different locations in the United States, Australia, and India. The specific configuration we considered has a nominal power rating of 100 kWe and 5 hours of thermal energy storage. Further, we considered two deployment strategies: a single stand-alone 100 kWe tower, and a 20 MWe cluster of many towers. For each scenario, we used a probabilistic analysis method to evaluate levelized cost of electricity. We found that this configuration has potential for cost-competitive electricity generation and the ability to improve grid flexibility for integration of intermittent renewables. In addition, solar resource, latitude, and local labor rates all have an impact on the levelized cost of electricity of the system.

14 SOLAR ENERGY↗

Sharing the Sun: Community Solar Deployment and Subscriptions (as of June 2023) [Slides]

This presentation describes the community solar market as of the first half (H1) of 2023. The community solar market analysis presented here is based primarily on data collected through Sharing the Sun, an initiative of the National Community Solar Partnership (NCSP). Sharing the Sun data collection and analysis is conducted by the National Renewable Energy Laboratory (NREL) as part of its support for implementation of the NCSP.

14 SOLAR ENERGY↗

Techno-Economic Analysis of Greenfield Geothermal Hybrid Power Plants using a Solar or Natural Gas Steam Topping Cycle

The relatively low generation costs associated with wind, solar photovoltaic (PV), and natural-gas power plants make it challenging for geothermal power plants to produce and sell the power that has the reliability and sustainability characteristics that are greatly needed in U.S. power markets. This is especially true for geothermal resources with low-to-medium temperatures, which results in relatively low-thermal efficiency and generation costs that are higher than those for wind, solar PV, and natural gas. This analysis evaluates solar thermal- and natural-gas combustion waste heat recovery-based topping cycle hybridization of geothermal binary power plants. This approach provides several benefits that may allow geothermal power plants to generate power at more competitive costs. First, the addition of solar thermal energy or natural-gas combustion waste heat input to a geothermal power plant provides additional heat input that can be converted to electrical power. Second, the temperature level of the heat obtained from concentrating solar collectors or natural-gas combustion exhaust is higher than that of geothermal heat, which provides opportunities for improving the efficiency of the conversion of thermal energy to electrical power. Third, the ease with which solar thermal systems integrate with energy storage and the flexibility of natural gas means power generation can occur during peak demand periods. The hybrid cycles are compared to equivalently sized, co-located, independent geothermal, concentrating solar, and/or natural-gas power plants. The hybrid cycle tends to produce slightly more power than the standalone plants combined. However, the hybrid plant Levelized Cost of Energy (LCOE) is slightly higher than the LCOE of the combined standalone power plants for each of the case study locations investigated. Using the steam-topping cycle, organic Rankine cycle (ORC)-bottoming cycle hybrid plant design to combine a solar thermal resource and low- temperature geothermal resource (<120 degrees C) leads to a hybrid plant with a lower LCOE than a standalone geothermal-only system. Thus, hybrid plants may enable the economic development of geothermal resources in locations with low geothermal resource temperatures. However, in areas with higher geothermal resource temperatures (>120 degrees C), the geothermal-only plant has a lower LCOE than the hybrid cycle and thus could be developed without the need for solar heat addition. iv A geothermal-natural-gas reciprocating engine hybrid plant was evaluated for an Elk Hills, California case study location. The Elk Hills case study analysis indicates that when the natural-gas engine operates for more than 12 hours per day the hybrid plant can produce power at an LCOE lower than a standalone geothermal plant, and comparable to that of the standalone natural-gas reciprocating engine, while also reducing the carbon intensity of the power generated relative to the standalone natural-gas engine. This may represent a scenario in which the hybrid plant provides an opportunity for the deployment of a low-temperature geothermal resource that otherwise may have an LCOE too high to develop and operate as a standalone resource, while also reducing the carbon intensity of natural-gas generation sources. A "triple-hybrid" plant that combines natural gas, solar thermal, thermal energy storage, and geothermal was also investigated. A natural-gas combustion turbine (NGCT) is added to the geothermal-solar hybrid such that the hot exhaust gas from the gas turbine provides an alternative source of heat to the steam turbine of the hybrid cycle. Analysis results suggest that the triple-hybrid plant has a significantly higher energy generation and revenue than a standalone NGCT or the original geothermal-solar hybrid. The triple-hybrid design benefits most from using a smaller solar field so that the solar energy can be dispatched at the most valuable times available. The triple-hybrid plant also has a lower LCOE than the standalone NGCT. The triple-hybrid plant was evaluated making simple assumptions about the dispatch profile of the gas cycle, and more nuanced and realistic dispatching schedules should be analyzed in future work.

15 GEOTHERMAL ENERGY↗