Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Software Quality Assurance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Obtaining Valid Safety Data for Software Safety Measurement and Process Improvement

We report on a preliminary case study to examine software safety risk in the early design phase of the NASA Constellation spaceflight program. Our goal is to provide NASA quality assurance managers with information regarding the ongoing state of software safety across the program. We examined 154 hazard reports created during the preliminary design phase of three major flight hardware systems within the Constellation program. Our purpose was two-fold: 1) to quantify the relative importance of software with respect to system safety; and 2) to identify potential risks due to incorrect application of the safety process, deficiencies in the safety process, or the lack of a defined process. One early outcome of this work was to show that there are structural deficiencies in collecting valid safety data that make software safety different from hardware safety. In our conclusions we present some of these deficiencies.

Basili, Victor r.↗

Growing the NASA Safety and Mission Assurance (SMA) Workforce of Tomorrow

The NASA Safety Center (NSC) was established in2006 in response to Columbia Accident Investigation Board (CAIB) recommendations to strengthen NASA’s safety program. The NSC supports all NASA centers and facilities. The NSC fosters world-class Safety and Mission Assurance (SMA) support for NASA programs and projects through professional development activities and the advancement of the following SMA technical disciplines: - Aviation Safety - Operational Safety - Quality Engineering - Reliability and Maintainability - SMA Technical Leadership - Software Assurance - System Safety The NSC’s Technical Excellence Office (TEO) is charged with encouraging technical excellence in NASA’s SMA community primarily through professional development products and services. TEO’s first initiative was the SMA Technical Excellence Program (STEP). STEP is a career-oriented, professional development roadmap for safety professionals, which is designed for the employee to learn specific knowledge and skills to improve performance in their current role.

Safety and Mission Assurance↗

The Role and Quality of Software Safety in the NASA Constellation Program

In this study, we examine software safety risk in the early design phase of the NASA Constellation spaceflight program. Obtaining an accurate, program-wide picture of software safety risk is difficult across multiple, independently-developing systems. We leverage one source of safety information, hazard analysis, to provide NASA quality assurance managers with information regarding the ongoing state of software safety across the program. The goal of this research is two-fold: 1) to quantify the relative importance of software with respect to system safety; and 2) to quantify the level of risk presented by software in the hazard analysis. We examined 154 hazard reports created during the preliminary design phase of three major flight hardware systems within the Constellation program. To quantify the importance of software, we collected metrics based on the number of software-related causes and controls of hazardous conditions. To quantify the level of risk presented by software, we created a metric scheme to measure the specificity of these software causes. We found that from 49-70% of hazardous conditions in the three systems could be caused by software or software was involved in the prevention of the hazardous condition. We also found that 12-17% of the 2013 hazard causes involved software, and that 23-29% of all causes had a software control. Furthermore, 10-12% of all controls were software-based. There is potential for inaccuracy in these counts, however, as software causes are not consistently scoped, and the presence of software in a cause or control is not always clear. The application of our software specificity metrics also identified risks in the hazard reporting process. In particular, we found a number of traceability risks in the hazard reports may impede verification of software and system safety.

Layman, Lucas↗

AIRSAR Web-Based Data Processing

The AIRSAR automated, Web-based data processing and distribution system is an integrated, end-to-end synthetic aperture radar (SAR) processing system. Designed to function under limited resources and rigorous demands, AIRSAR eliminates operational errors and provides for paperless archiving. Also, it provides a yearly tune-up of the processor on flight missions, as well as quality assurance with new radar modes and anomalous data compensation. The software fully integrates a Web-based SAR data-user request subsystem, a data processing system to automatically generate co-registered multi-frequency images from both polarimetric and interferometric data collection modes in 80/40/20 MHz bandwidth, an automated verification quality assurance subsystem, and an automatic data distribution system for use in the remote-sensor community. Features include Survey Automation Processing in which the software can automatically generate a quick-look image from an entire 90-GB SAR raw data 32-MB/s tape overnight without operator intervention. Also, the software allows product ordering and distribution via a Web-based user request system. To make AIRSAR more user friendly, it has been designed to let users search by entering the desired mission flight line (Missions Searching), or to search for any mission flight line by entering the desired latitude and longitude (Map Searching). For precision image automation processing, the software generates the products according to each data processing request stored in the database via a Queue management system. Users are able to have automatic generation of coregistered multi-frequency images as the software generates polarimetric and/or interferometric SAR data processing in ground and/or slant projection according to user processing requests for one of the 12 radar modes.

Chu, Anhua↗

Promoting regulatory acceptance of combined ion and neutron irradiation testing of nuclear reactor materials: Modeling and software considerations

As the needs for the nuclear energy industry continue to evolve in the 21st century, timely adoption of new technological solutions acceptable to regulatory agencies is critical. Quantitative prediction of radiation damage in materials and its impact on mechanical properties is a key component of licensing and regulatory decisions regarding nuclear power plants. Accelerated testing methodologies such as combined ion and neutron irradiation data sets are crucial for the development and deployment of new materials and new manufacturing methods (e.g., additive manufacturing). However, regulatory acceptance of accelerated testing methodologies is necessary for their adoption. Further, the present work discusses the fundamental basis for comparing ion- and neutron-induced material microstructures, the theory behind interpreting radiation damage across length and time scales and radiation types, and the codes, standards, and quality assurance concerns surrounding different modeling methods and software. In particular, recommendations are given as to the path forward that will enable national laboratories, academia, and industry to develop the modeling and software basis for regulatory acceptance of the combined use of ion and neutron irradiation for material performance evaluation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The quality assurance role in the Deep Space Network

The quality assurance section provides skilled personnel who perform the following functions: quality hardware engineering, quality software engineering, inspection and testing, and an independent assessment to quality, engineering and project requirements. The quality assurance section provides specifications, workmanship standards, process specifications and quality assurance procedures in support of DSN equipment. In addition, the quality assurance section reviews DSN engineering documents to ensure that appropriate and adequate quality provisions are included.

Sirpilla, R. L.↗

Software assurance standard

This standard specifies the software assurance program for the provider of software. It also delineates the assurance activities for the provider and the assurance data that are to be furnished by the provider to the acquirer. In any software development effort, the provider is the entity or individual that actually designs, develops, and implements the software product, while the acquirer is the entity or individual who specifies the requirements and accepts the resulting products. This standard specifies at a high level an overall software assurance program for software developed for and by NASA. Assurance includes the disciplines of quality assurance, quality engineering, verification and validation, nonconformance reporting and corrective action, safety assurance, and security assurance. The application of these disciplines during a software development life cycle is called software assurance. Subsequent lower-level standards will specify the specific processes within these disciplines.

Source record↗

NASA Quality Assurance in an MBSE world

Over the past decade or so, the emergence of Model Based Systems Engineering (MBSE) has demonstrated its desirability and value in terms of 1) being a single source of truth, 2) unambiguous definitions and relationships, and 3) after representation, the ability to explore/extract any sets of data on demand. While much work has been done in showing the value to the system engineering discipline in these areas, how does that value translate to the Safety and Mission Assurance (S&MA) world? This paper provides a vision of a very desirable future of NASA S&MA after it is fully integrated into the MBSE framework. We explore the impact and consequences of the MBSE Value items discussed above and how they impact the disciplines of quality assurance, reliability and maintainability, system safety, and software assurance. We provide insight into how the MBSE modeling tools can be used to define S&MA processes (ideally as a result of Use Case [1] elaboration of processes represented in MagicDraw®), produce S&MA products (ViewEditor output of various items), and represent S&MA disciplines (S&MA inside of MagicDraw). We also provide insight into the degree to which some elements can be directly integrated into a SysML® model and when, as often happens, an interface to some external source must be provided. The desirability of this future is part of the reason for the NASA Office of Safety and Mission Assurance’s (OSMA) recent creation of a Model Based Mission Assurance (MBMA) Program [2] and the MBMA annual workshops. We briefly summarize the efforts to date to generate S&MA Use Cases for eventual deployment into pilot and project efforts. Even simple use of the SysML modeling tools can be used to capture quality assurance tasks and integrate them with the systems engineering and produce products that are easy to use by quality practitioners that are unfamiliar with these methods. We anticipate finding opportunities to pilot and implement various Quality Assurance (QA) Use Cases in FY20. The MBMA Program is focused on implementation; the NASA Office of the Chief Engineer's Community of Practice, as well as the SmallSat communities, are very interested in the integration of S&MA. Finally, as projects move forward utilizing whatever efficiency increases they can find in a cost-constrained environment, the S&MA community cannot be caught unawares and needs to continue preparing for the ever-growing implementation of MBSE across NASA and our government and commercial partners.

Evans, John W↗

Incorporating cost-benefit analyses into software assurance planning

The objective is to use cost-benefit analyses to identify, for a given project, optimal sets of software assurance activities. Towards this end we have incorporated cost-benefit calculations into a risk management framework.

investment software quality software process impro↗

TU-G-BRD-02: Automated Systematic Quality Assurance Program for Radiation Oncology Information System Upgrades

Purpose: To: (1) describe an independent, automated, systematic software-based protocol for verifying clinical data accuracy/integrity for mitigation of data corruption/loss risks following radiation oncology information system (ROIS) upgrades; and (2) report on application of this approach in an academic/community practice environment. Methods: We propose a robust approach to perform quality assurance on the ROIS after an upgrade, targeting four data sources: (1) ROIS relational database; (2) ROIS DICOM interface; (3) ROIS treatment machine data configuration; and (4) ROIS-generated clinical reports. We investigated the database schema for differences between pre-/post-upgrade states. Paired DICOM data streams for the same object (such as RT-Plan/Treatment Record) were compared between pre-/post-upgrade states for data corruption. We examined machine configuration and related commissioning data files for changes and corruption. ROIS-generated treatment appointment and treatment parameter reports were compared to ensure patient encounter and treatment plan accuracy. This protocol was supplemented by an end-to-end clinical workflow test to verify essential ROI functionality and integrity of components interfaced during patient care chain of activities. We describe the implementation of this protocol during a Varian ARIA system upgrade at our clinic. Results: We verified 1,638 data tables with 2.4 billion data records. For 222 under-treatment patients, 605 DICOM RT plans and 13,480 DICOM treatment records retrieved from the ROIS DICOM interface were compared, with no differences in fractions, doses delivered, or treatment parameters. We identified 82 new data tables and 78 amended/deleted tables consistent with the upgrade. Reports for 5,073 patient encounters over a 2-week horizon were compared and were identical to those before the upgrade. Content in 12,237 xml machine files was compared, with no differences identified. Conclusion: An independent QA/validation approach for ROIS upgrades was developed and implemented at our clinic. The success of this approach ensures a robust QA of ROIS upgrades without manual paper/electronic checks and associated intensive labor.

60 APPLIED LIFE SCIENCES↗

Exploring Sustainability in Scientific Software through Code Quality & Test Coverage Metrics

Context: Scientific open-source software (SciOSS) plays a foundational role in research and engineering, yet its long-term sustainability has often been overlooked and remains a significant concern. Objective: This study investigates the long-term sustainability of SciOSS through code and test quality metrics. Method: We analyze CASS Software Portfolio projects, classifying them by sustainability and comparing their code structure, test coverage, and links between code quality and testing across the dataset. Results: Sustainable projects show higher, more consistent test coverage and clearer code-test correlations, while unsustainable ones show weaker patterns. Overall, test coverage is low in scientific software, and high complexity and coupling reduce testability. Conclusion: In this study, we present a practical, data-driven approach for assessing sustainability in scientific software, offering a foundation for evaluating long-term software health and supporting future efforts in quality assurance and sustainability monitoring.

Md mushfiqur rahman, Sheikh [University of Tenness↗

NASA quality assurance in an MBSE world

We explore the impact and consequences of the MBSE Value items discussed above and how they impact the disciplines of quality assurance, reliability and maintainability, system safety, and software assurance. We provide insight into how the MBSE modeling tools can be used to define S&MA processes (ideally as a result of Use Case [1] elaboration of processes represented in MagicDraw®), produce S&MA products (ViewEditor output of various items), and represent S&MA disciplines (S&MA inside of MagicDraw). We also provide insight into the degree to which some elements can be directly integrated into a SysML® model and when, as often happens, an interface to some external source must be provided.

Evans, John W.↗

Verification and Validation of PARET/ANL (V.7.6)

This report documents the software testing which has been performed for the PARET/ANL version 7.6 software. The capabilities addressed in this testing were selected based on the use of the software for analysis work under the Research and Test Reactors Department quality assurance program. The verification and validation have been performed and documented to address the steady-state capabilities of the software, as described in Chapter 2, and the transient capabilities, as described in Chapter 3. Testing based on the comparison between PARET/ANL calculations and analytical solutions, hand calculations, or another code calculations of the test cases confirms that all the identified capabilities of the software were implemented correctly.

97 MATHEMATICS AND COMPUTING↗

Markov chains for testing redundant software

A preliminary design for a validation experiment has been developed that addresses several problems unique to assuring the extremely high quality of multiple-version programs in process-control software. The procedure uses Markov chains to model the error states of the multiple version programs. The programs are observed during simulated process-control testing, and estimates are obtained for the transition probabilities between the states of the Markov chain. The experimental Markov chain model is then expanded into a reliability model that takes into account the inertia of the system being controlled. The reliability of the multiple version software is computed from this reliability model at a given confidence level using confidence intervals obtained for the transition probabilities during the experiment. An example demonstrating the method is provided.

White, Allan L.↗

SAS4A/SASSYS-1 Verification and Validation Plan for the Versatile Test Reactor

Software verification and validation (V&V) hold an important role in the safety analysis for nuclear facilities. Codes and models utilized in calculations that demonstrate the safety basis as part of a license application or authorization must demonstrate an acceptable pedigree with regard to key critical characteristics that are comprised of the functional and performance requirements of the software. This document describes the methodology for verification and validation of the SAS4A/SASSYS-1 systems-level liquid-metal safety analysis software in support of DOE authorization of the Versatile Test Reactor (VTR). The overall goal of this V&V effort is to demonstrate the suitability of SAS4A/SASSYS-1 for evaluation of safety performance and characterization of safety margins in VTR. To that end, the V&V methodology will be used to demonstrate the adequacy of the component and physical models of SAS4A/SASSYS-1 for the corresponding VTR design elements. This methodology, which has been derived as a generalized approach to the U.S. NRC’s evaluation model development and assessment process (EMDAP) of Regulatory Guide 1.203, entails four high-level activities: software requirements identification, assessment base development, determination of acceptance, and gap closure. The methodology has been generalized to be suitable for both verification and validation of the software for the VTR project. Several high-level engineering analysis quality assurance measures as well as supporting V&V methodology documentation are also described in this document to help support demonstration of software acceptance. To support initial development of the SAS4A/SASSYS-1 V&V basis, existing verification test problems and systems benchmarks are also identified and briefly described in this document.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Grid generation for computational CFD of full aerodynamic configurations

It is now possible to compute flow about very complex three-dimensional aerodynamic configurations. Grid generation is an essential part of such computations and a basic capability has been demonstrated. The present problems are: (1) choosing among the competing approaches (structured, unstructured or rectangular); (2) automating and packaging software for grid generation; (3) assessing and assuring grid quality; (4) solid boundary-surface representation and grid generation on solid boundaries; (5) automated domain decomposition (structured grids); (6) grid adaption during the flow solution process. This paper discusses some of the capabilities in the computation of complex three-dimensional grids and addresses some of he current challenges.

Smith, Robert E.↗

Increasing productivity through Total Reuse Management (TRM)

Total Reuse Management (TRM) is a new concept currently being promoted by the NASA Langley Software Engineering and Ada Lab (SEAL). It uses concepts similar to those promoted in Total Quality Management (TQM). Both technical and management personnel are continually encouraged to think in terms of reuse. Reuse is not something that is aimed for after a product is completed, but rather it is built into the product from inception through development. Lowering software development costs, reducing risk, and increasing code reliability are the more prominent goals of TRM. Procedures and methods used to adopt and apply TRM are described. Reuse is frequently thought of as only being applicable to code. However, reuse can apply to all products and all phases of the software life cycle. These products include management and quality assurance plans, designs, and testing procedures. Specific examples of successfully reused products are given and future goals are discussed.

Schuler, M. P.↗

Initial experience of ArcCHECK and 3DVH software for RapidArc treatment plan verification

The purpose of this study was to perform delivery quality assurance with ArcCHECK and 3DVH system (Sun Nuclear, FL) and to evaluate the suitability of this system for volumetric-modulated arc therapy (VMAT) (RapidArc [RA]) verification. This software calculates the delivered dose distributions in patients by perturbing the calculated dose using errors detected in fluence or planar dose measurements. The device is tested to correlate the gamma passing rate (%GP) and the composite dose predicted by 3DVH software. A total of 28 patients with prostate cancer who were treated with RA were analyzed. RA treatments were delivered to a diode array phantom (ArcCHECK), which was used to create a planned dose perturbation (PDP) file. The 3DVH analysis used the dose differences derived from comparing the measured dose with the treatment planning system (TPS)-calculated doses to perturb the initial TPS-calculated dose. The 3DVH then overlays the resultant dose on the patient's structures using the resultant “PDP” beams. Measured dose distributions were compared with the calculated ones using the gamma index (GI) method by applying the global (Van Dyk) normalization and acceptance criteria, i.e., 3%/3 mm. Paired differences tests were used to estimate statistical significance of the differences between the composite dose calculated using 3DVH and %GP. Also, statistical correlation by means of logistic regression analysis has been analyzed. Dose-volume histogram (DVH) analysis for patient plans revealed small differences between treatment plan calculations and 3DVH results for organ at risk (OAR), whereas planning target volume (PTV) of the measured plan was systematically higher than that predicted by the TPS. The t-test results between the planned and the estimated DVH values showed that mean values were incomparable (p < 0.05). The quality assurance (QA) gamma analysis 3%/3 mm showed that in all cases there were only weak-to-moderate correlations (Pearson r: 0.12 to 0.74). Moreover, clinically relevant differences increased with increasing QA passing rate, indicating that some of the largest dose differences occurred in the cases of high QA passing rates, which may be called “false negatives.” The clinical importance of any disagreement between the measured and the calculated dose is often difficult to interpret; however, beam errors (either in delivery or in TPS calculation) can affect the effectiveness of the patient dose. Further research is needed to determinate the role of a PDP-type algorithm to accurately estimate patient dose effect.

61 RADIATION PROTECTION AND DOSIMETRY↗