NASA Tech Briefs, March 2006

Topics covered include: Medical Signal-Conditioning and Data-Interface System; Instruments for Reading Direct-Marked Data-Matrix Symbols; Processing EOS MLS Level-2 Data; Ground Processing of Data From the Mars Exploration Rovers; Estimating Total Electron Content Using 1,000+ GPS Receivers; NASA Solar Array Demonstrates Commercial Potential; Improved Control of Charging Voltage for Li-Ion Battery; Programmable Pulse-Position-Modulation Encoder; Wavelength-Agile External-Cavity Diode Laser for DWDM; Pattern-Recognition Processor Using Holographic Photopolymer; Submicrosecond Power-Switching Test Circuit; Three-Function Logic Gate Controlled by Analog Voltage; Integrated System for Autonomous Science; Montage Version 3.0; Utilizing AI in Temporal, Spatial, and Resource Scheduling; Satellite Image Mosaic Engine; Architecture for Control of the K9 Rover; HFGMC Enhancement of MAC/GMC; Automated Activation and Deactivation of a System Under Test; Cleaning Carbon Nanotubes by Use of Mild Oxygen Plasmas; Generating Aromatics From CO2 on Mars or Natural Gas on Earth; Attaching Thermocouples by Peening or Crimping; Heat Treatment of Friction-Stir-Welded 7050 Aluminum Plates; Generating Breathable Air Through Dissociation of N2O; High-Performance Scanning Acousto-Ultrasonic System; Correction for Thermal EMFs in Thermocouple Feedthroughs; Using Quasiparticle Poisoning To Detect Photons; Estimating Resolution Lengths of Hybrid Turbulence Models; Education and Training Module in Alertness Management; Cargo-Positioning System for Next-Generation Spacecraft; Micro-Imagers for Spaceborne Cell-Growth Experiments; Holographic Solar Photon Thrusters; Plasma-Based Detector of Outer-Space Dust Particles; and Generation of Data-Rate Profiles of Ka-Band Deep-Space Links.

Source record↗

Micro-Imagers for Spaceborne Cell-Growth Experiments

A document discusses selected aspects of a continuing effort to develop five micro-imagers for both still and video monitoring of cell cultures to be grown aboard the International Space Station. The approach taken in this effort is to modify and augment pre-existing electronic micro-cameras. Each such camera includes an image-detector integrated-circuit chip, signal-conditioning and image-compression circuitry, and connections for receiving power from, and exchanging data with, external electronic equipment. Four white and four multicolor light-emitting diodes are to be added to each camera for illuminating the specimens to be monitored. The lens used in the original version of each camera is to be replaced with a shorter-focal-length, more-compact singlet lens to make it possible to fit the camera into the limited space allocated to it. Initially, the lenses in the five cameras are to have different focal lengths: the focal lengths are to be 1, 1.5, 2, 2.5, and 3 cm. Once one of the focal lengths is determined to be the most nearly optimum, the remaining four cameras are to be fitted with lenses of that focal length.

Behar, Alberto↗

Test Results of Selected Commercial DC/DC Converters under Cryogenic Temperatures - A Digest

DC/DC converters are widely used in space power systems in the areas of power management and distribution, signal conditioning, and motor control. Design of DC/DC converters to survive cryogenic temperatures will improve the power system performance, simplify design, and reduce development and launch costs. In this work, the performance of nine COTS modular, low-tomedium power DC/DC converters was investigated under cryogenic temperatures. The converters were evaluated in terms of their output regulation, efficiency, and input and output currents. At a given temperature, these properties were obtained at various input voltages and at different load levels. A summary on the performance of the tested converters was given. More comprehensive testing and in-depth analysis of performance under long-term exposure to extreme temperatures are deemed necessary to establish the suitability of these and other devices for use in the harsh environment of space exploration missions.

Patterson, Richard↗

Smart Sensor Demonstration Payload

Sensors are a critical element to any monitoring, control, and evaluation processes such as those needed to support ground based testing for rocket engine test. Sensor applications involve tens to thousands of sensors; their reliable performance is critical to achieving overall system goals. Many figures of merit are used to describe and evaluate sensor characteristics; for example, sensitivity and linearity. In addition, sensor selection must satisfy many trade-offs among system engineering (SE) requirements to best integrate sensors into complex systems [1]. These SE trades include the familiar constraints of power, signal conditioning, cabling, reliability, and mass, and now include considerations such as spectrum allocation and interference for wireless sensors. Our group at NASA s John C. Stennis Space Center (SSC) works in the broad area of integrated systems health management (ISHM). Core ISHM technologies include smart and intelligent sensors, anomaly detection, root cause analysis, prognosis, and interfaces to operators and other system elements [2]. Sensor technologies are the base fabric that feed data and health information to higher layers. Cost-effective operation of the complement of test stands benefits from technologies and methodologies that contribute to reductions in labor costs, improvements in efficiency, reductions in turn-around times, improved reliability, and other measures. ISHM is an active area of development at SSC because it offers the potential to achieve many of those operational goals [3-5].

Schmalzel, John↗

Embedded Sensors for Measuring Surface Regression

The development and evaluation of new hybrid and solid rocket motors requires accurate characterization of the propellant surface regression as a function of key operational parameters. These characteristics establish the propellant flow rate and are prime design drivers affecting the propulsion system geometry, size, and overall performance. There is a similar need for the development of advanced ablative materials, and the use of conventional ablatives exposed to new operational environments. The Miniature Surface Regression Sensor (MSRS) was developed to serve these applications. It is designed to be cast or embedded in the material of interest and regresses along with it. During this process, the resistance of the sensor is related to its instantaneous length, allowing the real-time thickness of the host material to be established. The time derivative of this data reveals the instantaneous surface regression rate. The MSRS could also be adapted to perform similar measurements for a variety of other host materials when it is desired to monitor thicknesses and/or regression rate for purposes of safety, operational control, or research. For example, the sensor could be used to monitor the thicknesses of brake linings or racecar tires and indicate when they need to be replaced. At the time of this reporting, over 200 of these sensors have been installed into a variety of host materials. An MSRS can be made in either of two configurations, denoted ladder and continuous (see Figure 1). A ladder MSRS includes two highly electrically conductive legs, across which narrow strips of electrically resistive material are placed at small increments of length. These strips resemble the rungs of a ladder and are electrically equivalent to many tiny resistors connected in parallel. A substrate material provides structural support for the legs and rungs. The instantaneous sensor resistance is read by an external signal conditioner via wires attached to the conductive legs on the non-eroding end of the sensor. The sensor signal can be transmitted from inside a high-pressure chamber to the ambient environment, using commercially available feedthrough connectors. Miniaturized internal recorders or wireless data transmission could also potentially be employed to eliminate the need for producing penetrations in the chamber case. The rungs are designed so that as each successive rung is eroded away, the resistance changes by an amount that yields a readily measurable signal larger than the background noise. (In addition, signal-conditioning techniques are used in processing the resistance readings to mitigate the effect of noise.) Hence, each discrete change of resistance serves to indicate the arrival of the regressing host material front at the known depth of the affected resistor rung. The average rate of regression between two adjacent resistors can be calculated simply as the distance between the resistors divided by the time interval between their resistance jumps. Advanced data reduction techniques have also been developed to establish the instantaneous surface position and regression rate when the regressing front is between rungs.

Gramer, Daniel J.↗

NASA Tech Briefs, July 2004

Topics: Optoelectronic Sensor System for Guidance in Docking; Hybrid Piezoelectric/Fiber-Optic Sensor Sheets; Multisensor Arrays for Greater Reliability and Accuracy; Integrated-Optic Oxygen Sensors; Ka-Band Autonomous Formation Flying Sensor; CMOS VLSI Active-Pixel Sensor for Tracking; Lightweight, Self-Deploying Foam Antenna Structures; Electrically Small Microstrip Quarter-Wave Monopole Antennas; A 2-to-28-MHz Phase-Locked Loop; Portable Electromyograph; Open-Source Software for Modeling of Nanoelectronic Devices; Software for Generating Strip Maps from SAR Data; Calibration Software for use with Jurassicprok; Software for Probabilistic Risk Reduction; Software Processes SAR Motion-Measurement Data; Improved Method of Purifying Carbon Nanotubes; Patterned Growth of Carbon Nanotubes or Nanofibers; Lightweight, Rack-Mountable Composite Cold Plate/Shelves; SiC-Based Miniature High-Temperature Cantilever Anemometer; Inlet Housing for a Partial-Admission Turbine; Lightweight Thermoformed Structural Components and Optics; Growing High-Quality InAs Quantum Dots for Infrared Lasers; Selected Papers on Protoplanetary Disks; Module for Oxygenating Water without Generating Bubbles; Coastal Research Imaging Spectrometer; Rapid Switching and Modulation by use of Coupled VCSELs; Laser-Induced-Fluorescence Photogrammetry and Videogrammetry; Laboratory Apparatus Generates Dual-Species Cold Atomic Beam; Laser Ablation of Materials for Propulsion of Spacecraft; Small Active Radiation Monitor; Hybrid Image-Plane/Stereo Manipulation; Partitioning a Gridded Rectangle into Smaller Rectangles; Digital Radar-Signal Processors Implemented in FPGAs; Part 1 of a Computational Study of a Drop-Laden Mixing Layer; and Some Improvements in Signal-Conditioning Circuits.

Source record↗

Compact Instruments Measure Helium-Leak Rates

Compact, lightweight instruments have been developed for measuring small flows of helium and/or detecting helium leaks in solenoid valves when the valves are nominally closed. These instruments do not impede the flows when the valves are nominally open. They can be integrated into newly fabricated valves or retrofitted to previously fabricated valves. Each instrument includes an upstream and a downstream thermistor separated by a heater, plus associated analog and digital heater-control, signal- conditioning, and data-processing circuits. The thermistors and heater are off-the-shelf surface mount components mounted on a circuit board in the flow path. The operation of the instrument is based on a well-established thermal mass-flow-measurement technique: Convection by the flow that one seeks to measure gives rise to transfer of heat from the heater to the downstream thermistor. The temperature difference measured by the thermistors is directly related to the rate of flow. The calibration curve from temperature gradient to helium flow is closely approximated via fifth-order polynomial. A microprocessor that is part of the electronic circuitry implements the calibration curve to compute the flow rate from the thermistor readings.

Stout, Stephen↗

Pressure-Sensor Assembly Technique

Nielsen Engineering & Research (NEAR) recently developed an ultrathin data acquisition system for use in turbomachinery testing at NASA Glenn Research Center. This system integrates a microelectromechanical- systems- (MEMS-) based absolute pressure sensor [0 to 50 psia (0 to 345 kPa)], temperature sensor, signal-conditioning application-specific integrated circuit (ASIC), microprocessor, and digital memory into a package which is roughly 2.8 in. (7.1 cm) long by 0.75 in. (1.9 cm) wide. Each of these components is flip-chip attached to a thin, flexible circuit board and subsequently ground and polished to achieve a total system thickness of 0.006 in. (0.15 mm). Because this instrument is so thin, it can be quickly adhered to any surface of interest where data can be collected without disrupting the flow being investigated. One issue in the development of the ultrathin data acquisition system was how to attach the MEMS pressure sensor to the circuit board in a manner which allowed the sensor s diaphragm to communicate with the ambient fluid while providing enough support for the chip to survive the grinding and polishing operations. The technique, developed by NEAR and Jabil Technology Services Group (San Jose, CA), is described below. In the approach developed, the sensor is attached to the specially designed circuit board, see Figure 1, using a modified flip-chip technique. The circular diaphragm on the left side of the sensor is used to actively measure the ambient pressure, while the diaphragm on the right is used to compensate for changes in output due to temperature variations. The circuit board is fabricated with an access hole through it so that when the completed system is installed onto a wind tunnel model (chip side down), the active diaphragm is exposed to the environment. After the sensor is flip-chip attached to the circuit board, the die is underfilled to support the chip during the subsequent grinding and polishing operations. To prevent this underfill material from getting onto the sensor s diaphragms, the circuit board is fabricated with two 25- micrometer-tall polymer rings, sized so that the diaphragms fit inside the rings once the chip is attached.

Pruzan, Daniel A.↗

Blade Vibration Measurement System

The Phase I project successfully demonstrated that an advanced noncontacting stress measurement system (NSMS) could improve classification of blade vibration response in terms of mistuning and closely spaced modes. The Phase II work confirmed the microwave sensor design process, modified the sensor so it is compatible as an upgrade to existing NSMS, and improved and finalized the NSMS software. The result will be stand-alone radar/tip timing radar signal conditioning for current conventional NSMS users (as an upgrade) and new users. The hybrid system will use frequency data and relative mode vibration levels from the radar sensor to provide substantially superior capabilities over current blade-vibration measurement technology. This frequency data, coupled with a reduced number of tip timing probes, will result in a system capable of detecting complex blade vibrations that would confound traditional NSMS systems. The hardware and software package was validated on a compressor rig at Mechanical Solutions, Inc. (MSI). Finally, the hybrid radar/tip timing NSMS software package and associated sensor hardware will be installed for use in the NASA Glenn spin pit test facility.

Platt, Michael J.↗

Extreme-Environment Silicon-Carbide (SiC) Wireless Sensor Suite

Phase II objectives: Develop an integrated silicon-carbide wireless sensor suite capable of in situ measurements of critical characteristics of NTP engine; Compose silicon-carbide wireless sensor suite of: Extreme-environment sensors center, Dedicated high-temperature (450 deg C) silicon-carbide electronics that provide power and signal conditioning capabilities as well as radio frequency modulation and wireless data transmission capabilities center, An onboard energy harvesting system as a power source.

Yang, Jie↗

Development and Calibration of a Field-Deployable Microphone Phased Array for Propulsion and Airframe Noise Flyover Measurements

A new aeroacoustic measurement capability has been developed consisting of a large channelcount, field-deployable microphone phased array suitable for airframe noise flyover measurements for a range of aircraft types and scales. The array incorporates up to 185 hardened, weather-resistant sensors suitable for outdoor use. A custom 4-mA current loop receiver circuit with temperature compensation was developed to power the sensors over extended cable lengths with minimal degradation of the signal to noise ratio and frequency response. Extensive laboratory calibrations and environmental testing of the sensors were conducted to verify the design's performance specifications. A compact data system combining sensor power, signal conditioning, and digitization was assembled for use with the array. Complementing the data system is a robust analysis system capable of near real-time presentation of beamformed and deconvolved contour plots and integrated spectra obtained from array data acquired during flyover passes. Additional instrumentation systems needed to process the array data were also assembled. These include a commercial weather station and a video monitoring / recording system. A detailed mock-up of the instrumentation suite (phased array, weather station, and data processor) was performed in the NASA Langley Acoustic Development Laboratory to vet the system performance. The first deployment of the system occurred at Finnegan Airfield at Fort A.P. Hill where the array was utilized to measure the vehicle noise from a number of sUAS (small Unmanned Aerial System) aircraft. A unique in-situ calibration method for the array microphones using a hovering aerial sound source was attempted for the first time during the deployment.

Humphreys, William M., Jr.↗

Sub-scale Waterflow Cavitation and Dynamic Transfer Function Testing of an Oxidizer Turbo-Pump Combined Inducer and Impeller

In 2009 and 2010, Concepts NREC prepared for and performed a series of tests on a 52% scale of a version of the Pratt & Whitney Rocketdyne J-2X Oxidizer Turbopump under a Phase III SBIR with NASA MSFC. The test article was a combined inducer and impeller, tested as a unit. This paper presents an overview of the test rig and facility, instrumentation, signal conditioning, data acquisition systems, testing approach, measurement developments, and lessons learned. Results from these tests were presented in the form of two papers at the previous JANNAF joint propulsion conference, in December of 2011.

Karon, D. M.↗

Operational Experience with the Electromagnetic Position Sensor (EPS) for the NASA 6-inch MSBS

A Magnetic Suspension and Balance System (MSBS), originally developed in 1969, has been recommissioned at NASA Langley and is being used to explore dynamic test techniques for planetary entry capsules. A critical component of this system is the Electromagnetic Position Sensor (EPS) which provides non-contact position measurement for control of the actively suspended model. The sensor’s operation is similar to a Linear Variable Differential Transformer (LVDT). However the EPS has a much larger gap and smaller core than traditional LVDTs and therefore it requires specialized driving and processing circuitry. This paper describes the history of this sensor system, its mechanical and electrical design, and the efforts to improve signal conditioning circuitry.

T. D. Schott↗

Practical SiC JFET-R Analog Integrated Circuit Design for Extreme Environment Applications

Silicon carbide (SiC) junction field effect transistor and SiC resistor (SiC JFET-R) integrated circuits(ICs) have uniquely demonstrated prolonged operation above 450 °C that promises significant operational improvements to a variety of NASA missions. However, the SiC epiwafers used to fabricate these ICs suffer from epi-growth process immaturity that imparts large and systematic spreads in JFET threshold voltages as a function of the device distance from the center on the wafer. Furthermore, the unprecedently wide range of intended application operating temperatures (in many cases over 600 °C wide) imparts as much as 5-fold change in JFET bias currents. This Technical Memorandum documents methods by which both temperature and radius associated JFET electrical parameter variances can be adequately eliminated, or even exploited in JFET-R circuit designs. Full analog circuit examples, including operational amplifiers, and SPICE simulations across experimentally documented SiC JFET parameter extremes are given to illustrate the efficacy of these methods. The reader may use the examples in this memorandum as either an end point, to get a desired analog signal conditioning design into hardware implemented in SiC JFET-R ICs, or as a basis point from which to derive further improvement.

Michael J Krasowski↗

A Discussion of the Failure of a Quad Diode Module and Efforts to Assure the Flight Spares

In 2019 the International Space Station (ISS) experienced an on on-orbit failure that affected 1 of 28 Battery Charge Discharge Units (BCDUs). Telemetry pointed to a short circuit failure of a Power Rectifier Quad Diode Module. Astronauts removed the failed unit from service which was then returned to Earth for failure analysis. The failure analysis confirmed that the quad diode module had failed short circuit. The investigation identified silver dendrites had grown on the insulated, sloped edge of the mesa semiconductor die of the failed diode and also a 2nd diode in the same quad diode module. Voids between the diode’s protective encapsulating ring and the die provided space within which dendrites were able to form and cause catastrophic failure. The NASA Engineering & Safety Center (NESC) convened a EEE Parts Sub-Team to investigate root cause and to assist with risk assessment for all of the flight diode modules (4 distinct production lots) and the flight spares (from a 5th lot). Analysis of the original diode manufacturer’s read and record screening test data identified some lots which contained diodes with parametric instabilities that could signal conditions suited for silver dendrite formation. Computed Tomography (CT) X-ray screening inspection was performed on flight spare modules to identify diodes that do not exhibit voids between the edge of die and encapsulating ring as a mitigation against dendrite formation.

Jay Brusse↗

800 °C Demonstrated kHz SiC IC Electronics and Pressure Sensors as Technical Foundation for Realizing MHz DARPA HOTS Goals

The HOTS program will develop a technology for high-bandwidth, high-dynamic-range sensing at high temperature. Performance will be validated through the development and demonstration of a pressure sensor module (i.e., integrated transducer and signal-conditioning microelectronics) achieving the following performance goals: NASA Glenn has unique technology experience in extreme environment pressure sensors & IC electronics, including at 800 °C in air, providing significant risk reduction in meeting DARPA HOTS goals. Appropriate partnership and tech transfer should accelerate realization of DARPA HOTS hard technical challenges.

SiC pressure sensor electronics high temperature↗

Development of a Field-Deployable Microphone Phased Array for Airframe Noise Flyover Measurements

This technical memorandum describes in detail the construction and use of a large channel-count, field-deployable microphone phased array designed for airframe noise flyover measurements for a range of aircraft types and scales. The array incorporated 185 hardened, weather-resistant sensors suitable for outdoor use. A custom 4-mA current loop receiver circuit with temperature compensation was developed to power the sensors over extended cable lengths with minimal loss of signal-to-noise. Extensive calibrations and performance testing of the sensors were conducted to verify the design specifications. A compact data system combining sensor power, signal conditioning, and digitization was assembled for use with the array. Complementing the data system was a robust analysis system capable of near real-time presentation of beamformed and deconvolved contour plots and integrated spectra obtained from data acquired during flyover passes of the array. Additional instrumentation systems needed to process the array data were also developed, including a commercial 10-meter weather station comprised of a sonic anemometer, aspirated temperature/humidity probe and pressure sensor. Unique methods for assessing the health of the array in-situ were developed and demonstrated. A detailed mock-up of the instrumentation suite (phased array, weather station, and data processor) was performed in the NASA Langley Acoustic Development Laboratory in 2014 to vet the system performance. Issues with the sensors and electronics were identified during the mock-up and subsequently corrected. The array was then deployed for preliminary field testing at Fort A.P. Hill in Virginia in 2015 followed by the array being utilized in three separate full-scale airframe noise test campaigns at Edwards Air Force Base in California from 2016 to 2018 where the system was used to characterize the noise generated by both baseline and treated flaps and main landing gear on a commercial transport-sized vehicle.

Phased Array↗

xEMU Suit Integrated Audio Communications System: Ambient and EVA Pressure Testing System Performance

Testing across several airlock and EVA thermal and pressure scenarios has demonstrated that the Integrated Audio System of NASA’s Exploration Extravehicular Mobility Unit (xEMU) spacesuits transmits and receives intelligible audio communications without the use of a commcap or similar worn device. The xEMU audio system consists of internal loudspeakers and digital microphones (Integrated Communications System –ICS) combined with an adaptive Acoustic Echo Canceller (AEC), outbound voice operated transmission (VOX), and automatic gain control (AGC). Transducers are mounted in an “exploded commcap” configuration with helmet-attached speakers near the ears and three microphones positioned at the collar. The AGC removes inbound audio signals (e.g.,suit, Mission Control, Lander, C&W tones) from the outbound comms stream, reducing echo and feedback (squeal) in low-noise suit environments. The reduction of worn communication equipment increases crewmember comfort, range of movement, and situational awareness. However, test results also highlight the need for proper fan, duct, pump, and gas flow integration with suit acoustics and audio. Ductwork may serve as waveguides for various component and structure-borne noise. Sharply angled ducts can generate turbulent-flow noise. Gas flow from inlets above the crewmember’s head can generate noise when cascading over the faceplate and collar (or commcap) microphones. Sufficient acoustic noise levels (1) require increased gain to boost inbound audio, and (2) may distort signals resulting in AEC disruption or artifacts. Suit-noise levels decline with reduced pressure (density), but then elevated speech and audio effort/power become necessary. Whether the Integrated Audio System, commcap, or other device is used, suit acoustic noise can mask speech in outbound comms. This reduces intelligibility and requires other AECs/devices to suppress comms noise. Yet, adjusting a few components may yield significant improvement. We discuss xEMU audio functionality, demonstrate how acoustical treatment combined with inbound signal conditioning improved clarity during tests, and discuss future modifications.