Direct Liquid Cooling for Electronic Equipment

This report documents a demonstration of an electronic-equipment cooling system in the engineering prototype development stage that can be applied in data centers. The technology provides cooling by bringing a water-based cooling fluid into direct contact with high-heat-generating electronic components. This direct cooling system improves overall data center energy efficiency in three ways: 1) High-heat-generating electronic components are more efficiently cooled directly using water, capturing a large portion of the total electronic equipment heat generated. This captured heat reduces the load on the less-efficient air-based data center room cooling systems. The combination contributes to the overall savings. 2) The power consumption of the electronic equipment internal fans is significantly reduced when equipped with this cooling system. 3) The temperature of the cooling water supplied to the direct cooling system can be much higher than that commonly provided by facility chilled water loops, and therefore can be produced with lower cooling infrastructure energy consumption and possibly compressor-free cooling. Providing opportunities for heat reuse is an additional benefit of this technology. The cooling system can be controlled to produce high return water temperatures while providing adequate component cooling. The demonstration was conducted in a data center located at Lawrence Berkeley National Laboratory in Berkeley, California. Thirty-eight servers equipped with the liquid cooling system and instrumented for energy measurements were placed in a single rack. Two unmodified servers of the same configuration, located in an adjacent rack, were used to provide a baseline. The demonstration characterized the fraction of heat removed by the direct cooling technology, quantified the energy savings for a number of cooling infrastructure scenarios, and provided information that could be used to investigate heat reuse opportunities. Thermal measurement data were used with data center energy use modeling software to estimate overall site energy use. These estimates show that an overall data center energy savings of approximately 20 percent can be expected if a center is retrofitted as specified in the models used. Increasing the portion of heat captured by this technology is an area suggested for further development.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Simple XML Producer-Consumer Protocol

There are many different projects from government, academia, and industry that provide services for delivering events in distributed environments. The problem with these event services is that they are not general enough to support all uses and they speak different protocols so that they cannot interoperate. We require such interoperability when we, for example, wish to analyze the performance of an application in a distributed environment. Such an analysis might require performance information from the application, computer systems, networks, and scientific instruments. In this work we propose and evaluate a standard XML-based protocol for the transmission of events in distributed systems. One recent trend in government and academic research is the development and deployment of computational grids. Computational grids are large-scale distributed systems that typically consist of high-performance compute, storage, and networking resources. Examples of such computational grids are the DOE Science Grid, the NASA Information Power Grid (IPG), and the NSF Partnerships for Advanced Computing Infrastructure (PACIs). The major effort to deploy these grids is in the area of developing the software services to allow users to execute applications on these large and diverse sets of resources. These services include security, execution of remote applications, managing remote data, access to information about resources and services, and so on. There are several toolkits for providing these services such as Globus, Legion, and Condor. As part of these efforts to develop computational grids, the Global Grid Forum is working to standardize the protocols and APIs used by various grid services. This standardization will allow interoperability between the client and server software of the toolkits that are providing the grid services. The goal of the Performance Working Group of the Grid Forum is to standardize protocols and representations related to the storage and distribution of performance data. These standard protocols and representations must support tasks such as profiling parallel applications, monitoring the status of computers and networks, and monitoring the performance of services provided by a computational grid. This paper describes a proposed protocol and data representation for the exchange of events in a distributed system. The protocol exchanges messages formatted in XML and it can be layered atop any low-level communication protocol such as TCP or UDP Further, we describe Java and C++ implementations of this protocol and discuss their performance. The next section will provide some further background information. Section 3 describes the main communication patterns of our protocol. Section 4 describes how we represent events and related information using XML. Section 5 describes our protocol and Section 6 discusses the performance of two implementations of the protocol. Finally, an appendix provides the XML Schema definition of our protocol and event information.

Smith, Warren↗

Using Transparent Informed Prefetching (TIP) to reduce file read latency

As processor performance gains continue to outstrip Input/Output gains, I/O performance is becoming critical to overall system performance. File read latency is the most significant bottleneck for high performance I/O. Other aspects of I/O performance benefit from recent advances in disk bandwidth and throughput resulting from disk arrays, and in write performance derived from buffered write behind and the Log-structured File System. The access gap problem limiting improvements in read latency is exacerbated by distributed file systems operating over networks with diverse bandwidth. Focus is on extending the power of caching and prefetching to reduce file read latencies by exploiting hints from high-levels of a system. Such Transparent Informed Prefetching, TIP, and its benefits are described. It is argued that hints that disclose high level knowledge are a means for transferring optimization information across, without violating, module boundaries. How TIP can be used to convert the high throughput of new technologies such as disk arrays and log-structured file systems into low latency for applications is discussed. Our preliminary experiments show reductions in wall - clock execution time of 13 percent and 20 percent for a multiple module compilation tool (make) accessing data on a local disk and remote Coda file server, respectively, and a reduction of 30 percent for a text search (grep) remotely accessing many small files.

Patterson, R. H.↗

Review of Human Cognitive Performance in Spaceflight

Human space exploration is inherently hazardous, particularly for lon g duration (LD) missions (22 days or longer). Maintenance of cognitive functioning is essential, but flight environments pose numerous pote ntial risks to the brain and cognitive performance (eg, radiation, to xins, chronic stress, sleep deprivation, hypercarbia, fluid shifts, h ormone imbalances, and injury). There have been persistent anecdotal reports of cognitive deficits during missions, but an up?-to-date rev iew of the evidence for such changes has remained unavailable. Method s: We identified and reviewed English language publications found via electronic searches in PubMed, PsycInfo, Inspec, the NASA Technical Report Server, and the Defense Technical Information Center, plus rec ursive searches of publication bibliographies. Search terms included the word cognition, cognitive, or performance along with spaceflight, flight, mission, or closely related terms. Results: Inter?-study variability precluded meta?-analysis. Some 32 published studies involving cognitive assessment during spaceflight were identified, involving a total of 110 participants (mean: 3.4 participants per study). The lo ngest?-duration study spanned 438 days, with six additional studies i nvolving flight durations of 90 days, and 11 more studies involved fl ight durations exceeding 21 days. The available evidence failed to st rongly support or refute the existence of cognitive deficits in LD sp aceflight, in part due to inadequate power or control conditions. Evi dence of increased variability in cognitive performance during spacef light, both within and between individuals, was common. Discussion: T hese results represent a negative finding based on small numbers of s ubjects for any given cognitive function. The increased variability within and (particularly) between individuals highlights the potential danger of generalizing from case studies. A mismatch therefore remain s between anecdotal reports describing generalized cognitive slowing, attention and memory problems during missions and the experimental e vidence supporting such deficits. Since a major justification for man ned spaceflight rests with the cognitive flexibility of humans, addit ional studies and further analysis of existing operational data appea rs warranted.

Strangman, Gary↗

A microbased shared virtual world prototype

Virtual reality (VR) allows sensory immersion and interaction with a computer-generated environment. The user adopts a physical interface with the computer, through Input/Output devices such as a head-mounted display, data glove, mouse, keyboard, or monitor, to experience an alternate universe. What this means is that the computer generates an environment which, in its ultimate extension, becomes indistinguishable from the real world. 'Imagine a wraparound television with three-dimensional programs, including three-dimensional sound, and solid objects that you can pick up and manipulate, even feel with your fingers and hands.... 'Imagine that you are the creator as well as the consumer of your artificial experience, with the power to use a gesture or word to remold the world you see and hear and feel. That part is not fiction... three-dimensional computer graphics, input/output devices, computer models that constitute a VR system make it possible, today, to immerse yourself in an artificial world and to reach in and reshape it.' Our research's goal was to propose a feasibility experiment in the construction of a networked virtual reality system, making use of current personal computer (PC) technology. The prototype was built using Borland C compiler, running on an IBM 486 33 MHz and a 386 33 MHz. Each game currently is represented as an IPX client on a non-dedicated Novell server. We initially posed the two questions: (1) Is there a need for networked virtual reality? (2) In what ways can the technology be made available to the most people possible?

Pitts, Gerald↗

Evaluating software defined networking solutions to reduce the digital attack surface of nuclear security systems

Most nuclear security systems used today were not designed for today’s threat environment. Systems that were intended to be stand alone are now interconnected. Devices that have a single purpose are built on multi-purpose platforms and communication protocols that, while effective, have no ability to authenticate authorized versus unauthorized commands. These attributes provide an attacker significant ability to affect the system, pivot throughout the interconnected networks, and remain undetected if he/she is able to compromise a single node. Software defined networking (SDN) has been used for years by information technology (IT) cloud service providers to quickly provision or remove servers or other systems to meet changing demand. The same concept has recently been applied to operational technology (OT) systems to enable very fast failover on critical systems that have stringent and deterministic (<5ms) transmit/receive times. By carefully engineering the communication flows through a network using preplanned routes and specific pathways it is possible to achieve deterministic and extremely reliable message delivery even when components fail. This engineering approach to network design has added security benefits including securing the networking control plane, eliminating network scanning and mapping, inhibiting ARP spoofing and host masquerading, eliminating unauthorized network pivoting and enabling greater situational awareness on the network. SDN in OT environments is new but early testing in electrical power and other critical infrastructure has shown it to be a very powerful tool for building reliable networks and reducing the digital attack surface of the network. The authors tested a software defined network switch on a simple physical protection system with components commonly found in nuclear security systems and found improved mitigations to denial of service attacks, lateral movement and network reconnaissance. The paper details the tests and their results.

Cyber security, Nuclear security, software defined↗

Accessing Wind Tunnels From NASA's Information Power Grid

The NASA Ames wind tunnel customers are one of the first users of the Information Power Grid (IPG) storage system at the NASA Advanced Supercomputing Division. We wanted to be able to store their data on the IPG so that it could be accessed remotely in a secure but timely fashion. In addition, incorporation into the IPG allows future use of grid computational resources, e.g., for post-processing of data, or to do side-by-side CFD validation. In this paper, we describe the integration of grid data access mechanisms with the existing DARWIN web-based system that is used to access wind tunnel test data. We also show that the combined system has reasonable performance: wind tunnel data may be retrieved at 50Mbits/s over a 100 base T network connected to the IPG storage server.

Becker, Jeff↗

Remote Diagnosis of the International Space Station Utilizing Telemetry Data

Modern systems such as fly-by-wire aircraft, nuclear power plants, manufacturing facilities, battlefields, etc., are all examples of highly connected network enabled systems. Many of these systems are also mission critical and need to be monitored round the clock. Such systems typically consist of embedded sensors in networked subsystems that can transmit data to central (or remote) monitoring stations. Moreover, many legacy are safety systems were originally not designed for real-time onboard diagnosis, but a critical and would benefit from such a solution. Embedding additional software or hardware in such systems is often considered too intrusive and introduces flight safety and validation concerns. Such systems can be equipped to transmit the sensor data to a remote-processing center for continuous health monitoring. At Qualtech Systems, we are developing a Remote Diagnosis Server (RDS) that can support multiple simultaneous diagnostic sessions from a variety of remote subsystems.

Deb, Somnath↗

Comprehensive Metabolite Identification Strategy Using Multiple Two-Dimensional NMR Spectra of a Complex Mixture Implemented in the COLMARm Web Server

Identification of metabolites in complex mixtures represents a key step in metabolomics. A new strategy is introduced, which is implemented in a new public web server, COLMARm, that permits the co-analysis of up to three 2D NMR spectra, namely 13C-1H HSQC, 1H-1H TOCSY, and 13C-1H HSQC-TOCSY for the comprehensive, accurate, and efficient performance of this task. The highly versatile and interactive nature of COLMARm permits its application to a wide range of metabolomics samples independent of the magnetic field. Database query is performed using the HSQC spectrum and the top metabolite hits are then validated against the TOCSY-type experiment(s) by superimposing the expected cross-peaks on the mixture spectrum. In this way the user can directly accept or reject candidate metabolites by taking advantage of the complementary spectral information offered by these experiments and their different sensitivities. The power of COLMARm is demonstrated for a human serum sample uncovering the existence of 14 metabolites that hitherto were not identified by NMR.

Bingol, Kerem↗

Low cost, flexible, and distribution level universal grid analyser platform: designs and implementations

This study presents the designs and implementations of a distribution level open-universal grid analyser (Open-UGA) platform. The proposed Open-UGA platform consists of distribution-level phasor measurement units (PMUs), a standard signal generator, a router, and a server. Firstly, an overall introduction for the software, hardware, and server architectures of the Open-UGA platform is given. To give a detailed design, the software, hardware, server block diagrams, flowcharts, and printed circuit board photo of the Open-UGA platform are presented in detail. Then, four different types of distribution level PMU algorithms are introduced and implemented in the Open-UGA platform to verify the flexibility and reconfigurability. The flowcharts and functionalities of these four UGAs with different PMU algorithms are given as example implementations. Lastly, a performance comparison is conducted with both quantitative and illustrative results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Anomaly Detection and Approximate Similarity Searches of Transients in Real-time Data Streams

Abstract We present Lightcurve Anomaly Identification and Similarity Search ( LAISS ), an automated pipeline to detect anomalous astrophysical transients in real-time data streams. We deploy our anomaly detection model on the nightly Zwicky Transient Facility (ZTF) Alert Stream via the ANTARES broker, identifying a manageable ∼1–5 candidates per night for expert vetting and coordinating follow-up observations. Our method leverages statistical light-curve and contextual host galaxy features within a random forest classifier, tagging transients of rare classes ( spectroscopic anomalies), of uncommon host galaxy environments ( contextual anomalies), and of peculiar or interaction-powered phenomena ( behavioral anomalies). Moreover, we demonstrate the power of a low-latency (∼ms) approximate similarity search method to find transient analogs with similar light-curve evolution and host galaxy environments. We use analogs for data-driven discovery, characterization, (re)classification, and imputation in retrospective and real-time searches. To date, we have identified ∼50 previously known and previously missed rare transients from real-time and retrospective searches, including but not limited to superluminous supernovae (SLSNe), tidal disruption events, SNe IIn, SNe IIb, SNe I-CSM, SNe Ia-91bg-like, SNe Ib, SNe Ic, SNe Ic-BL, and M31 novae. Lastly, we report the discovery of 325 total transients, all observed between 2018 and 2021 and absent from public catalogs (∼1% of all ZTF Astronomical Transient reports to the Transient Name Server through 2021). These methods enable a systematic approach to finding the “needle in the haystack” in large-volume data streams. Because of its integration with the ANTARES broker, LAISS is built to detect exciting transients in Rubin data.

79 ASTRONOMY AND ASTROPHYSICS↗

'Green-in-Three' IT Solutions Protecting Workers and the Environment - 12526

The U.S. Department of Energy (DOE), Environmental Management (EM), DOE Richland Operations Office (RL), Mission Support Alliance (MSA), and Lockheed Martin Services, Inc. (LMSI), Information Technology partnered in an effort to reduce environmental impacts, energy use, and operating costs and improve worker safety through consolidation, centralization, and standardization of Information Technology (IT) assets on the Hanford Site. Green-in-Three is an IT Value strategy, which is moving Hanford from an inefficient, antiquated 20. Century IT architecture to a smart, green, flexible 21. Century IT architecture that delivers information anywhere at any time to Hanford Mission partners. The 'Green-in-three' efforts to date have had a significant impact on meeting and exceeding the overall IT Value Strategy to decrease IT maintenance and delivery costs and move Hanford into a smart, green, and flexible 21. Century IT architecture. Some of the results and impacts are as follows: - Thirteen data centers were reduced to two, freeing up approximately 279 m{sup 2} (3000 ft{sup 2})) of space; - Reduced data center energy use 50%, from 120,000 to 60,000 kW; - Excessed 9 metric tons (10 tons) of server equipment; - Removed and properly disposed of 2871 kg (6,300 lb) lead acid batteries; - Projects saved over $1 M in fiber and copper cable installation through 2011; - Developed or improved partnerships with local, state, and federal agencies, Tribes, and Site contractors; - Increased wireless coverage for improved access to remote areas. Moving forward to 2012, the impact of these accomplishments will be realized in the years to come. IT services will be delivered in days instead of months. Field personnel will have access to information at the point of performance, reducing travel time. Remote monitoring, telemetry, and/or video can be conducted using the wireless network; reducing travel time for field inspections. Emergency personnel have access to critical information at the incident site, saving valuable time. Full deployment of the VoIP technologies will reduce power use by 1,000,000 kWh/yr for telecommunications equipment, driving home the IT Value Strategy of Green-in-Three. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Power User Interface

Power User Interface 5.0 (PUI) is a system of middleware, written for expert users in the Earth-science community, PUI enables expedited ordering of data granules on the basis of specific granule-identifying information that the users already know or can assemble. PUI also enables expert users to perform quick searches for orderablegranule information for use in preparing orders. PUI 5.0 is available in two versions (note: PUI 6.0 has command-line mode only): a Web-based application program and a UNIX command-line- mode client program. Both versions include modules that perform data-granule-ordering functions in conjunction with external systems. The Web-based version works with Earth Observing System Clearing House (ECHO) metadata catalog and order-entry services and with an open-source order-service broker server component, called the Mercury Shopping Cart, that is provided separately by Oak Ridge National Laboratory through the Department of Energy. The command-line version works with the ECHO metadata and order-entry process service. Both versions of PUI ultimately use ECHO to process an order to be sent to a data provider. Ordered data are provided through means outside the PUI software system.

Pfister, Robin↗

Application configuration selection for energy-efficient execution on multicore systems

Balanced performance and energy consumption are incorporated in the design of modern computer systems. Several runtime factors, such as concurrency levels, thread mapping strategies, and dynamic voltage and frequency scaling (DVFS) should be considered in order to achieve optimal energy efficiency fora workload. Selecting appropriate run-time factors, however, is one of the most challenging tasks because the run-time factors are architecture-specific and workload-specific. And while most existing works concentrate on either static analysis of the workload or run-time prediction results, we present a hybrid two-step method that utilizes concurrency levels and DVFS settings to achieve the energy efficiency configuration for a worldoad. The experimental results based on a Xeon E5620 server with NPB and PARSEC benchmark suites show that the model is able to predict the energy efficient configuration accurately. On average, an additional 10% EDP (Energy Delay Product) saving is obtained by using run-time DVFS for the entire system. An off-line optimal solution is used to compare with the proposed scheme. Finally, the experimental results show that the average extra EDP saved by the optimal solution is within 5% on selective parallel benchmarks.

97 MATHEMATICS AND COMPUTING↗

Time-Sensitive Quantum Key Distribution (TSQKD)

This is the final report for the Time-Sensitive Quantum Key Distribution (TSQKD) project and summarizes the demonstration and longer-term field testing at an electric utility, EPB of Chattanooga, in Chattanooga, TN. The demonstration was held virtually (due to the COVID pandemic) and successfully executed the tests outlined in a prior report, “Task 10: Develop a QKD Time-Sensitive Networking Test Suite” submitted 9/30/2020. The portable test equipment explained in Task 10 and earlier task reports was tested at GE Research remotely connected with Qubitekk’s QKD equipment in San Diego, CA. Then the equipment was shipped to Qubitekk for physical integration with Qubitekk’s Quantum DataLoc™ Key Server 1570nm (http://qubitekk.com/products/qkd-for-industrial-control-systems-ics/). The portable test equipment was shipped from Qubitekk to EPB for demonstration and extended field testing. A summary of the demonstration and test results are described in this report. The demo and extended field test results are enabled by the NETCONF/YANG IEEE P1913 data management model developed as part of this project (Task 5). The NETCONF/YANG IEEE P1913 data management model demonstrated significant practical utility in providing a common means of monitoring and configuring the QKD system. All data in this report comes from the IEEE P1913 data management model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spacecraft Cabin Ventilation Fan Research at NASA

NASA has recently made the geometry and solid model for a spacecraft cabin ventilation fan prototype available to the public via electronic file downloads from the NASA Technical Report Server. This fan can be used for research and development by many organizations. The fan is 3.5 inches in diameter, 9 inches long, and weighed 3.6 lb. The NASA Quiet Space Fan was designed to make 3.64 inches of water pressure rise at 150.3 cfm of airflow at 12,000 rpm at standard air conditions of 70ºF and 14.7 psia. The performance of the metal version of the fan was measured to be 3.48 inches of water at 150.6 cfm at design speed. A low-noise blade-vane count was chosen to try to reduce tone noise generated by this fan by cutting off the first three blade passing frequency tones. In-duct microphone array measurements indicated that the most evident tones occur for frequencies of 1800 Hz (1 BPF) and 7200 Hz (4 BPF). Using reverberant room standard testing methods, the A-weighted sound power level for the fan operating at design point conditions was measured to be 71 dBA. This report describes the current set of publicly available information for this fan. The fan was designed, optimized, and tested with tools and techniques that NASA has traditionally used for turbofan engine research. This is one way that technology developed for aerospace applications can be used more broadly, since quiet and efficient fans are needed for many ventilation systems on spacecraft, aircraft, watercraft, land vehicles, and buildings.

fan, noise, ventilation↗

An Overview of the Database Framework for GEM Detector under CMS Experiment at CERN

In this paper, we give an overview of the database framework which we have developed for the Gas Electron Multiplier (GEM) Detector at CERN. The GEM constitutes a powerful addition to the family of fast radiation detectors; originally developed for particle physics experiments, and has spawned a large number of developments and applications. The GEM database framework comprises four components. The first component is the database itself. There are three instances of the database which have been deployed. One is for the development purpose which contains test data, other one is for the integration purposes while the last one is for the production purpose which contains real data. The database further comprises various schemas and each schema consists of different tables in it. We use separate schemas for various types of tables. The second component of the database framework is called DB Loader. The DB Loader is used to load data into database. The data is prepared in the predefined format which is in the XML form. Then the xml file is copied into a spool area of the server in which DB loader is running. Once the file is copied, the DB Loader loads the file into the database. The loader returns appropriate status codes after performing database insertion/update operation. The status of the database operations is checked against the status code which is returned by the loader. The third component of the database framework comprises graphical user interface (GUI). This is a web-based interface which can be accessed from the internet. This interface is basically used for the detector construction and to perform various quality control tests on the detector and its components. The last component of the database framework is called online monitoring system (OMS). The OMS is data visualization framework for the various detectors of the CMS experiment at CERN. It is also used to display data for the GEM. It enables users to view and retrieve database contents without having to learn database specifics.

Imran, Muhammad↗

Spacecraft Cabin Ventilation Fan Research at NASA

NASA has recently made the geometry and solid model for a spacecraft cabin ventilation fan prototype available to the public via electronic file downloads from the NASA Technical Reports Server. This fan can be used for research and development by many organizations. The NASA Quiet Space Fan is 8.89 cm (3.50 in) in diameter, 22.9 cm (9.00 in) long, and the metal fan weighs 1.63 kg (3.6 lbm). The fan was designed to generate a system total pressure rise of 906 Pa (3.64 inches of water) at 0.709 m3/s (150.3 cfm) of airflow at 12,000 rpm (at 21.1ºC (70ºF) and 14.7 psia). Performance measured using standardized techniques showed good agreement with design and predicted values. A low-noise blade-vane count was chosen to reduce tonal noise generated by rotor-stator interaction for the first three blade passing frequency harmonics. In-duct microphone array measurements indicated that the most evident tones occur at frequencies of 1,800 Hz (1 BPF) and 7,200 Hz (4 BPF). Using reverberant room standard testing methods, the A-weighted sound power level for the fan operating at design point conditions was measured to be 71 dBA. This report describes the current set of publicly available information for this fan. The fan was designed, optimized, and tested with tools and techniques that NASA has traditionally used for turbofan engine research. This demonstrates that technology developed for aerospace applications can be used more broadly, since quiet and efficient fans are needed for many ventilation systems in spacecraft, aircraft, watercraft, land vehicles, and buildings.

fan↗