Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Model-based compositional predictions for a differential scanning calorimetry/thermogravimetric analysis-mass spectrometry system used for heat of vaporization measurements

A Differential Scanning Calorimetry/Thermogravimetric Analysis (DSC/TGA) procedure for determination of Heat of Vaporization (HOV) of fuel and surrogate fuel mixtures has been previously utilized for evaluation of oxygenate impacts on spark ignition fuels. This analysis has been further leveraged with mass spectrometry (MS) to elucidate vapor phase compositional changes during evaporation. In this study we focus on a simple system of three compounds (ethanol, n-hexane, and n-octane) to provide a model-based understanding of the evaporation process under these experimental conditions. An Aspen Plus model was set up to provide liquid and vapor phase concentration predictions during mixture evaporation using the initial mixture composition, and measured temperature and mass loss profiles from DSC/TGA experiments. Agreements between the trends of the MS ion count profiles and model composition predictions provide a degree of validation of this modeling approach that can allow the interpretation and extrapolation of DSC/TGA measurements for more complex fuel mixtures.

33 ADVANCED PROPULSION SYSTEMS↗

A study on the creep behavior of alloy 709 using in-situ scanning electron microscopy

In this research, an experimental evaluation of creep properties of Alloy 709 in the temperature range of 750–850 °C was undertaken. Alloy 709 is a novel austenitic stainless steel with 20% Cr and 25% Ni by wt% that was developed for application in structural components of nuclear power plants. Creep rupture tests were conducted in an in-situ heating-loading and Scanning Electron Microscope (SEM) unit equipped with Electron Backscatter Diffraction (EBSD) detector and Energy Dispersive Spectroscopy (EDS). “Real-time” creep damage mechanisms of Alloy 709 at various stresses and temperatures using a flat, un-notched sample with continuously reducing cross-section is studied so that the failure and maximum creep damage occurred at the center of the sample where the in-situ SEM imaging could be focused. Accelerated creep tests at temperatures and stresses above service conditions were performed by employing multiple blocks of constant loads where the loads were increased once the sample attained constant creep rate, indicating a secondary creep regime. This technique ensures multiple data points can be obtained from the same test, saves the time required for an otherwise long-term creep test and usage of SEM. Further, Coincident Site Lattice (CSL) boundary maps were collected as control maps before testing, and the grain boundaries were observed during the creep test to understand the effect of grain boundary character on the creep damage mechanism. Void growth, grain boundary separation, and sliding were found to be the main creep mechanisms whose rate is dependent on stress and temperature. Failure mechanisms studied on the fracture surface using SEM fractography were correlated to the sample surface observations to create complementary information to better understand the underline creep mechanism of Alloy 709.

36 MATERIALS SCIENCE↗

Biofouling of filtration membranes in wastewater reuse: In situ visualization with confocal laser scanning microscopy

The filtration membranes utilized in advanced treatment of municipal wastewater are prone to biological fouling. Permeability loss and water recovery limitations due to fouling necessitate additional pretreatment and membrane cleaning, which raise the cost of water reuse. Better fouling mitigation calls for a deeper understanding of biofilm behavior on water reuse membranes. This study uses confocal microscopy to monitor biofouling under realistic conditions. To simulate water reuse, a miniature flow cell with microfiltration and ultrafiltration membranes was operated under typical filtration conditions using secondary effluent from California's East Bay Municipal Utility District. The growing biofilms were stained for extracellular polymeric substances and live and dead cells, and they were monitored in situ under filtration conditions with a confocal laser scanning microscope to produce 2-D and 3-D images. In situ image series revealed biofilm growth and removal processes including internal and external fouling, extracellular polymeric substance production, wrinkling, delamination, and film re-deposition. Additionally, changes in biofilm morphology between in situ and ex situ images highlighted limitations of ex situ imaging. Here, these results provide insight into the physical and biological mechanisms of biofouling in hopes of informing the development of improved techniques for biofouling mitigation.

ultrafiltration↗

Explainability and human intervention in autonomous scanning probe microscopy

The broad adoption of machine learning (ML)-based autonomous experiments (AEs) in material characterization and synthesis requires strategies development for understanding and intervention in the experimental workflow. Here, we introduce and realize a post-experimental analysis strategy for deep kernel learning-based autonomous scanning probe microscopy. This approach yields real-time and post-experimental indicators for the progression of an active learning process interacting with an experimental system. We further illustrate how this approach can be applied to human-in-the-loop AEs, where human operators make high-level decisions at high latencies setting the policies for AEs, and the ML algorithm performs low-level, fast decisions. The proposed approach is universal and can be extended to other techniques and applications such as combinatorial library analysis.

47 OTHER INSTRUMENTATION↗

Secondary porosity prediction in complex carbonate reefs using 3D CT scan image analysis and machine learning

Development and preservation of carbonate porosity and permeability are critical to characterizing reservoirs. However, secondary porosity, such as vugs and fractures, are difficult to identify and require collection of expensive wireline tools or core sampling. Wireline logs and cores have traditionally been used to identify the presence of secondary porosity but fail to quantify the contribution to total reservoir porosity. Additionally, advanced wireline logs and core are not readily available for most wells. Dual energy CT scans were collected on whole core from the A-1 Carbonate and Brown Niagaran formations drawn from six wells in northern Michigan. 3D analysis techniques were applied to identify and isolate secondary porosity features. A series of machine learning and data analytics techniques were applied to the dataset to predict secondary porosity features on basic wireline logs. The predictive model successfully predicted secondary porosity with high confidence.

02 PETROLEUM↗

Mapping the phases of quantum chromodynamics with beam energy scan

We review the present status of the search for a phase transition and critical point as well as anomalous transport phenomena in Quantum Chromodynamics (QCD), with an emphasis on the Beam Energy Scan program at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory. We present the conceptual framework and discuss the observables deemed most sensitive to a phase transition, QCD critical point, and anomalous transport, focusing on fluctuation and correlation measurements. Selected experimental results for these observables together with those characterizing the global properties of the systems created in heavy ion collisions are presented. We then discuss what can be already learned from the currently available data about the QCD critical point and anomalous transport as well as what additional measurements and theoretical developments are needed in order to discover these phenomena.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging hole-density inhomogeneity in arsenic-doped CdTe thin films by scanning capacitance microscopy

We report nanometer-scale hole-density imaging in As-doped CdTe films by scanning capacitance microscopy (SCM). The hole-density profiling is validated by contrasting a CdTe cross-section sample made by molecular-beam epitaxy with systematically increased As doping in a staircase pattern over the range of 10 15 -10 18 /cm 3 within a single film. In polycrystalline films, the carrier distribution is significantly nonuniform, with inhomogeneity ranging from several hundred nm to several um and hole density varying by one order of magnitude (low 10^16 to low 10 17 /cm 3 ). This nonuniformity is distributed randomly, independent of the grain structure and grain boundaries (GBs). Kelvin probe force microscopy (KPFM) maps the surface potential and is correlated to cathodoluminescence (CL) and SCM by imaging over identical areas. Higher potential and lower CL intensity are found on GBs but not by SCM contrast; this indicates positive GB charging and recombination, but not GB-specific hole-density changes. The overall KPFM potential image is in rough agreement with the SCM carrier distribution and indicates band-edge potential fluctuations. Nonuniform carrier concentration, potential fluctuations, and defect recombination can all cause voltage and performance loss in As-doped CdTe solar technology.

14 SOLAR ENERGY↗

Denoising atomic resolution 4D scanning transmission electron microscopy data with tensor singular value decomposition

Tensor singular value decomposition (SVD) is a method to find a low-dimensional representation of data with meaningful structure in three or more dimensions. Here, tensor SVD has been applied to denoise atomic-resolution 4D scanning transmission electron microscopy (4D STEM) data. On data simulated from a SrTiO 3 [100] perfect crystal and a Si [110] edge dislocation, tensor SVD achieved an average peak signal-to-noise ratio (PSNR) of ~40 dB, which matches or exceeds the performance of other denoising methods, with processing times at least 100 times shorter. On experimental data from SrTiO 3 [100] and LiZnSb [11 2 ¯ 0]/GaSb [110] samples, tensor SVD denoises multiple GB 4D STEM data sets in ten minutes on a typical personal computer. Denoising with tensor SVD improves both convergent beam electron diffraction patterns and virtual-aperture annular dark field images.

36 MATERIALS SCIENCE↗

Identification and correction of temporal and spatial distortions in scanning transmission electron microscopy

Scanning transmission electron microscopy (STEM) has become the technique of choice for quantitative characterization of atomic structure of materials, where the minute displacements of atomic columns from high-symmetry positions can be used to map strain, polarization, octahedra tilts, and other physical and chemical order parameter fields. The latter can be used as inputs into mesoscopic and atomistic models, providing insight into the correlative relationships and generative physics of materials on the atomic level. However, these quantitative applications of STEM necessitate understanding the microscope induced image distortions and developing the pathways to compensate them both as part of a rapid calibration procedure for in situ imaging, and the post-experimental data analysis stage. Here, we explore the spatiotemporal structure of the microscopic distortions in STEM using multivariate analysis of the atomic trajectories in the image stacks. Based on the behavior of principal component analysis (PCA), we develop the Gaussian process (GP)-based regression method for quantification of the distortion function. The limitations of such an approach and possible strategies for implementation as a part of in-line data acquisition in STEM are discussed. Here, the analysis workflow is summarized in a Jupyter notebook that can be used to retrace the analysis and analyze the reader's data.

36 MATERIALS SCIENCE↗

Relation between sampling, sensitivity and precision in strain mapping using the Geometric Phase Analysis method in Scanning Transmission Electron Microscopy

The sensitivity and the precision of the Geometric Phase Analysis (GPA) method for strain characterization is a topic widely discussed in the literature and is usually difficult to quantify. Indeed, the GPA precision is intricately linked to the resolution of the strain maps defined when masking the periodic reflections in Fourier space. In this study an additional parameter, sampling, is proposed to be analyzed regarding the precision of GPA by developing the concept of a phase noise in the GPA equations. Both experimentally and theoretically, the following article demonstrates how the precision, and the sensitivity of the GPA method is improved when using a larger pixel spacing to record an electron micrograph in Scanning Transmission Electron Microscopy (STEM). In conclusion, the counterintuitive concept of increasing the field of view to improve the GPA precision results in an extension of the application of strain characterization methods in STEM towards low deformation levels.

47 OTHER INSTRUMENTATION↗

A Fast Algorithm for Scanning Transmission Electron Microscopy Imaging and 4D-STEM Diffraction Simulations

Scanning transmission electron microscopy (STEM) is an extremely versatile method for studying materials on the atomic scale. Many STEM experiments are supported or validated with electron scattering simulations. However, using the conventional multislice algorithm to perform these simulations can require extremely large calculation times, particularly for experiments with millions of probe positions as each probe position must be simulated independently. Recently, the plane-wave reciprocal-space interpolated scattering matrix (PRISM) algorithm was developed to reduce calculation times for large STEM simulations. Here, we introduce a new method for STEM simulation: partitioning of the STEM probe into “beamlets,” given by a natural neighbor interpolation of the parent beams. This idea is compatible with PRISM simulations and can lead to even larger improvements in simulation time, as well requiring significantly less computer random access memory (RAM). We have performed various simulations to demonstrate the advantages and disadvantages of partitioned PRISM STEM simulations. We find that this new algorithm is particularly useful for 4D-STEM simulations of large fields of view. We also provide a reference implementation of the multislice, PRISM, and partitioned PRISM algorithms.

97 MATHEMATICS AND COMPUTING↗

An Automated Scanning Transmission Electron Microscope Guided by Sparse Data Analytics

Abstract Artificial intelligence (AI) promises to reshape scientific inquiry and enable breakthrough discoveries in areas such as energy storage, quantum computing, and biomedicine. Scanning transmission electron microscopy (STEM), a cornerstone of the study of chemical and materials systems, stands to benefit greatly from AI-driven automation. However, present barriers to low-level instrument control, as well as generalizable and interpretable feature detection, make truly automated microscopy impractical. Here, we discuss the design of a closed-loop instrument control platform guided by emerging sparse data analytics. We hypothesize that a centralized controller, informed by machine learning combining limited a priori knowledge and task-based discrimination, could drive on-the-fly experimental decision-making. This platform may unlock practical, automated analysis of a variety of material features, enabling new high-throughput and statistical studies.

47 OTHER INSTRUMENTATION↗

Isotope-Resolved Electron Energy Loss Spectroscopy in a Monochromated Scanning Transmission Electron Microscope

The development and implementation of high-stability monochromators in state-of-the-art aberration-corrected scanning transmission electron microscopes has enabled materials characterization with an energy resolution as good as 3 meV. This allows the vibrational modes, which would otherwise be obscured by the energy spread of the electron beam, to be probed with very high precision in molecular materials. Since the vibrational energies depend on the weight of the atomic nuclei, vibrational spectroscopy can distinguish isotopes whose only difference lies in their neutron content. This opens up isotopic analysis and mapping in transmission electron microscopy as two important new research areas. In this paper, we review the monochromated electron energy loss spectroscopy (EELS) instrumentation, discuss optimal methods for probing beam-sensitive materials without destroying them, and review key nanoscale isotope-resolved results.

47 OTHER INSTRUMENTATION↗

Nanoscale Magnetic Domains in Polycrystalline Mn 3 Sn Films Imaged by a Scanning Single-Spin Magnetometer

Noncollinear antiferromagnets with novel magnetic orders, vanishingly small net magnetization, and exotic spin related properties hold enormous promise for developing next-generation, transformative spintronic applications. A major ongoing research focus of this community is to explore, control, and harness unconventional magnetic phases of this emergent material system to deliver state-of-the-art functionalities for modern microelectronics. Here we report direct imaging of magnetic domains of polycrystalline Mn 3 Sn films, a prototypical noncollinear antiferromagnet, using nitrogen-vacancy-based single-spin scanning microscopy. Nanoscale evolution of local stray field patterns of Mn 3 Sn samples are systematically investigated in response to external driving forces, revealing the characteristic “heterogeneous” magnetic switching behaviors in polycrystalline textured Mn 3 Sn films. Furthermore, our results contribute to a comprehensive understanding of inhomogeneous magnetic orders of noncollinear antiferromagnets, highlighting the potential of nitrogen-vacancy centers to study microscopic spin properties of a broad range of emergent condensed matter systems.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Deriving Material Properties from Feedback Error Signals in Scanning Tunneling Microscopy

Imperfections in measurements, e.g., deviations and broadening, are not devoid of information; rather, they can reveal valuable physical properties and processes. Scanning tunneling microscopy leverages a negative feedback loop to regulate the tunneling current. Practically, current fluctuates around its set point, and such deviations are considered insignificant and ignored. Here, in this study, we investigate the information embedded in these deviations. In the constant-current mode with an active feedback loop, we observe an unexpected persistent DC current offset from its set point when the tunneling junction is periodically perturbed. We demonstrate both experimentally and theoretically that such error signals encode local tunneling barrier heights and the square of local differential conductance as a consequence of the interplay between rectification and active feedback compensation. We provide evidence on the generalizability of this phenomenology to other negative feedback systems. This new approach has the potential to broadly impact physical sciences by allowing rapid measurements without lock-in amplifiers.

36 MATERIALS SCIENCE↗

Recreating Fuel Cell Catalyst Degradation in Aqueous Environments for Identical-Location Scanning Transmission Electron Microscopy Studies

The recent surge in interest of proton exchange membrane fuel cells (PEMFCs) for heavy-duty vehicles increases the demand on the durability of oxygen reduction reaction electrocatalysts used in the fuel cell cathode. This prioritizes efforts aimed at understanding and subsequently controlling catalyst degradation. Identical-location scanning transmission electron microscopy (IL-STEM) is a powerful method that enables precise characterization of degradation processes in individual catalyst nanoparticles across various stages of cycling. Recreating the degradation processes that occur in PEMFC membrane electrode assemblies (MEAs) within the aqueous cell used for IL-STEM experiments is vital for generating an accurate understanding of these processes. In this work, we investigate the type and degree of catalyst degradation achieved by cycling in an aqueous cell compared to a PEMFC MEA. While significant degradation is observed in IL-STEM experiments performed on a traditional Pt catalyst using the standard accelerated stress test potential window (0.6-0.95 VRHE), degradation of a PtCo catalyst designed for heavy-duty vehicle use is very limited compared to that observed in MEAs. We therefore explore various experimental parameters such as temperature, acid type, acid concentration, ionomer content, and potential window to identify conditions that reproduce the degradation observed in MEAs. We find that by extending the cycling potential window to 0.4-1.0 V RHE in an electrolyte containing Pt ions, the degraded particle size distribution and alloy composition better match that observed in MEAs. In particular, these conditions increase the relative contribution of Ostwald ripening, which appears to play a more significant role in the degradation of larger alloy particles supported on high-surface-area carbons than coalescence. Results from this work highlight the potential for discrepancies between ex situ aqueous experiments and MEA tests. While different catalysts may require a unique modification to the AST protocol, strategies provided in this work enable future in situ and identical-location experiments that will play an important role in the development of robust catalysts for heavy-duty vehicle applications.

30 DIRECT ENERGY CONVERSION↗

Nanoscale Surface Structure of Nanometer-Thick Ferroelectric BaTiO 3 Films Revealed by Synchrotron X-ray Scanning Tunneling Microscopy: Implications for Catalytic Adsorption Reactions

Ferroelectric nanomaterials are of interest in catalysis, non-volatile memory, and neuromorphic computing among other applications because of their switchable structure that can alter electronic and interface properties of a single material. The investigation of the role of polarization on the surface structure and chemistry of ferroelectric nanomaterials is a longstanding challenge, as it ideally requires a combination of both nanoscale imaging and chemical spectroscopy. In this work we study a model ferroelectric BaTiO 3 thin film by synchrotron X-ray scanning tunneling microscopy (SX-STM), a unique method which integrates nanoscale surface imaging and chemically sensitive spectroscopy. We find that polarization switching from downward to upward in (001)single crystalline BaTiO 3 thin films increases the intensity of X-ray absorption across Ba M, Ti L and O K edges. Chemical mapping of nanometer sized domains further demonstrates the modulation of surface structures upon polarization switching, as well as confirming the trends observed in single point experiments across the surface. Here, we complement these measurements with ab-initio computational absorption spectroscopy to elucidate the effect of polarization switching on the core-hole excitations using the Bethe-Salpeter equation approach. Our experimental and theoretical results thus confirm a stronger binding strength for the upward polarized surface with molecular O 2 as a model reactant, offering mechanistic evidence that supports previous reports. This work advances the understanding of the surface chemistry and electronic structure of ferroelectrics, which can ultimately aid strategies to design interfaces with tailored properties.

77 NANOSCIENCE AND NANOTECHNOLOGY↗